Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gravity offloading methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Active Response Gravity Offload and Method

A variable gravity field simulator can be utilized to provide three dimensional simulations for simulated gravity fields selectively ranging from Moon, Mars, and micro-gravity environments and/or other selectable gravity fields. The gravity field simulator utilizes a horizontally moveable carriage with a cable extending from a hoist. The cable can be attached to a load which experiences the effects of the simulated gravity environment. The load can be a human being or robot that makes movements that induce swinging of the cable whereby a horizontal control system reduces swinging energy. A vertical control system uses a non-linear feedback filter to remove noise from a load sensor that is in the same frequency range as signals from the load sensor.

Dungan, Larry K.↗

NASA Tech Briefs, September 2011

Topics covered include: Fused Reality for Enhanced Flight Test Capabilities; Thermography to Inspect Insulation of Large Cryogenic Tanks; Crush Test Abuse Stand; Test Generator for MATLAB Simulations; Dynamic Monitoring of Cleanroom Fallout Using an Air Particle Counter; Enhancement to Non-Contacting Stress Measurement of Blade Vibration Frequency; Positively Verifying Mating of Previously Unverifiable Flight Connectors; Radiation-Tolerant Intelligent Memory Stack - RTIMS; Ultra-Low-Dropout Linear Regulator; Excitation of a Parallel Plate Waveguide by an Array of Rectangular Waveguides; FPGA for Power Control of MSL Avionics; UAVSAR Active Electronically Scanned Array; Lockout/Tagout (LOTO) Simulator; Silicon Carbide Mounts for Fabry-Perot Interferometers; Measuring the In-Process Figure, Final Prescription, and System Alignment of Large; Optics and Segmented Mirrors Using Lidar Metrology; Fiber-Reinforced Reactive Nano-Epoxy Composites; Polymerization Initiated at the Sidewalls of Carbon Nanotubes; Metal-Matrix/Hollow-Ceramic-Sphere Composites; Piezoelectrically Enhanced Photocathodes; Iridium-Doped Ruthenium Oxide Catalyst for Oxygen Evolution; Improved Mo-Re VPS Alloys for High-Temperature Uses; Data Service Provider Cost Estimation Tool; Hybrid Power Management-Based Vehicle Architecture; Force Limit System; Levitated Duct Fan (LDF) Aircraft Auxiliary Generator; Compact, Two-Sided Structural Cold Plate Configuration; AN Fitting Reconditioning Tool; Active Response Gravity Offload System; Method and Apparatus for Forming Nanodroplets; Rapid Detection of the Varicella Zoster Virus in Saliva; Improved Devices for Collecting Sweat for Chemical Analysis; Phase-Controlled Magnetic Mirror for Wavefront Correction; and Frame-Transfer Gating Raman Spectroscopy for Time-Resolved Multiscalar Combustion Diagnostics.

Source record↗

Segmented Hexagonal Antenna Reflector Concentrically Stacked Using Shape Memory Composite Tubular Hinges

A new architecture for solid surface reflector antennas scalable to sizes greater than 10 m is presented. The design uses compact, light, and simple advanced deployable structures to create sub-reflectors that can be assembled in space into larger units using a robotic arm. The seven-panel hexagonal sub-reflector is divided into hexagonal panels that stack concentrically and vertically. The central panel is connected to each side panel on the back side by a pair of tubular shape memory composite hinges that enable the required deployment kinematics with controlled dynamics. A secondary mechanism closes the interpanel gap. The focus of the paper is on the development of the sub-reflector elements, namely the tubular hinges that use embedded heaters and sensors for triggering and control, the actuation mechanisms, and the lightweight sandwich construction reflector panels. A parametric study using finite element analyses was conducted to assess how design features of the hinge affect its stowage and deployment dynamics. The preliminary component fabrication and testing results for the two-panel assembly breadboard model are outlined. Finally, the results of the test campaign with the brassboard reflector model are presented. A comparison of deployed reflector surface deviation between the measured surface after the stowage and deployment process and the pre-test scans and the nominal surface revealed root mean square errors of less than 1 mm, as required by X-band radiofrequency transmission.

gravity offloading methods↗

Modeling and Simulation of the Angel Upper Limb Offload Device: Branching Into New Methods

BACKGROUND: The Active Response Gravity Offload System (ARGOS) provides an analog environment for extravehicular activity (EVA) testing and training. Discomfort has been observed during longer suited test sessions. While the subject’s core is offloaded during surface EVA evaluations, his/her arms experience full Earth gravity and can become overly fatigued, especially during suited tests which involve reaching and prolonged arm extensions. A device (ARGOS Negation of Gravitational Effects on the Limbs: ANGEL) to offload the weight of the arms and suit sleeves is being developed by JSC’s Flight Systems Branch of the Software, Robotics, and Simulation Division. Previously we have shared preliminary modeling of that device and kinematics based on motion capture data. Here we present an alternative approach to determine device kinematics by calculating ANGEL component angles with an OpenSim plugin. We compare calculated angles to inverse kinematics (IK) derived ones with the goal of validating the model. This new method can be further informative for device design and analytically testing different configurations to achieve desired reduced gravity conditions (e.g., lunar gravity (Lg) or Martian gravity (Mg)). We have compared calculated angles with IK-derived angles in tests with a shirt-sleeve subject positioned in a test stand with a Mark-III Hard Upper Torso (HUT) and Portable Life Support System (PLSS) mockup and arm weights to emulate the weight of the suit sleeve as well as a suited subject in ARGOS with a Mark-III suit. A variety of upper body tasks were completed in the former and full-body tasks in the latter. METHODS AND RESULTS: To model the offload device, we augment the OpenSim human model topology with the offload mechanism components and joints, using CAD models to represent the mechanism graphically. The joint angles of the device are calculated in the OpenSim plugin by modeling how the components configure themselves under the offloading spring tension given a particular IK-derived arm position. There are four ANGEL components with a total of 5 degrees of freedom (DOFs), each component has a single DOF except for the cuff which is modeled as 2 DOFs. The sickle/yaw bracket and cuff rotation angles are determined statically based on the assumptions that the sickle will track the attachment point of the cuff and that the cuff will rotate such that the attachment point is at its highest point. The cuff tilt, linker and V-bracket angles are then determined by optimizing their positions to approach a mechanical equilibrium. The calculated linker angle is compared to three different methods of determining the linker line-of-force kinematically (from V-bracket to center-cuff, cuff highest point or marker-derived position). Given the joint angles of the device, the spring force and resulting force on the arm is computed by the plugin and applied as an external load in inverse dynamics (ID) to enable study of overall shoulder joint torques as well as offload achieved. We verify the calculated joint angles by using the inverse kinematic data. The average difference in angles is the smallest for the V-bracket and linker, around 1 to 5 degrees for most trials. The resulting offload and shoulder torque are comparable between calculated and IK-derived angles. In summary, we have developed a method to calculate the joint angles of an exoskeleton-like upper limb offloading device currently in development. We have also developed a custom plugin which will be a valuable tool to optimize device configurations for a desired gravitational environment, probe the offload achieved for motions recorded outside of our test suite, and inform future design improvements.

L B Nilsson↗

Modeling and Simulation of The Angel Upper Limb Offload Device: Branching into New Methods

BACKGROUND: The Active Response Gravity Offload System (ARGOS) provides an analog environment for extravehicular activity (EVA) testing and training. Discomfort has been observed during longer suited test sessions. While the subject’s core is offloaded during surface EVA evaluations, his/her arms experience full Earth gravity and can become overly fatigued, especially during suited tests which involve reaching and prolonged arm extensions. A device (ARGOS Negation of Gravitational Effects on the Limbs: ANGEL) to offload the weight of the arms and suit sleeves is being developed by JSC’s Flight Systems Branch of the Software, Robotics, and Simulation Division. Previously we have shared preliminary modeling of that device and kinematics based on motion capture data. Here we present an alternative approach to determine device kinematics by calculating ANGEL component angles with an OpenSim plugin. We compare calculated angles to inverse kinematics (IK) derived ones with the goal of validating the model. This new method can be further informative for device design and analytically testing different configurations to achieve desired reduced gravity conditions (e.g., lunar gravity (Lg) or Martian gravity (Mg)). We have compared calculated angles with IK-derived angles in tests with a shirt-sleeve subject positioned in a test stand with a Mark-III Hard Upper Torso (HUT) and Portable Life Support System (PLSS) mockup and arm weights to emulate the weight of the suit sleeve as well as a suited subject in ARGOS with a Mark-III suit. A variety of upper body tasks were completed in the former and full-body tasks in the latter. METHODS AND RESULTS: To model the offload device, we augment the OpenSim human model topology with the offload mechanism components and joints, using CAD models to represent the mechanism graphically. The joint angles of the device are calculated in the OpenSim plugin by modeling how the components configure themselves under the offloading spring tension given a particular IK-derived arm position. There are four ANGEL components with a total of 5 degrees of freedom (DOFs), each component has a single DOF except for the cuff which is modeled as 2 DOFs. The sickle/yaw bracket and cuff rotation angles are determined statically based on the assumptions that the sickle will track the attachment point of the cuff and that the cuff will rotate such that the attachment point is at its highest point. The cuff tilt, linker and V-bracket angles are then determined by optimizing their positions to approach a mechanical equilibrium. The calculated linker angle is compared to three different methods of determining the linker line-of-force kinematically (from V-bracket to center-cuff, cuff highest point or marker-derived position). Given the joint angles of the device, the spring force and resulting force on the arm is computed by the plugin and applied as an external load in inverse dynamics (ID) to enable study of overall shoulder joint torques as well as offload achieved. We verify the calculated joint angles by using the inverse kinematic data. The average difference in angles is the smallest for the V-bracket and linker, around 1 to 5 degrees for most trials. The resulting offload and shoulder torque are comparable between calculated and IK-derived angles. In summary, we have developed a method to calculate the joint angles of an exoskeleton-like upper limb offloading device currently in development. We have also developed a custom plugin which will be a valuable tool to optimize device configurations for a desired gravitational environment, probe the offload achieved for motions recorded outside of our test suite, and inform future design improvements.

L B Nilsson↗

Experimental Setup for Mechanically Testing Subscale Triangular, Rollable, and Collapsible Deployable Composite Booms

High-strain composite deployable space structures are used for space infrastructure and science applications such as solar array supports, antennae, camera masts, and lightweight structures supporting solar sailing propulsion elements. Triangular, Rollable, and Collapsible (TRAC) deployable composite booms are one example of a high-strain composite deployable structure and were studied using novel experimental test and characterization methods developed under the Gravity Offloading and Analysis of Long Imperfection-sensitive Elements (GOALIE) project. In the present work, a subscale 7-m-long TRAC boom was suspended vertically to orient gravity along the length of the boom. By orienting vertically, highly nonlinear and unstable behavior often encountered during horizontally oriented gravity offload testing of similar structures was reduced. Pretest analytical predictions of TRAC booms indicated three unique failure modes, loads, and locations for three unique loading cases of in-plane bending, out-of-plane bending, and axial compression. To investigate the predicted behavior, an experimental test was set up to impart mechanical loads to a subscale TRAC boom. The experimental setup, loading cases, and instrumentation used to characterize the mechanical response of a subscale TRAC boom are described in this paper.

Experimental testing↗

Experimental Setup for Mechanically Testing Subscale Triangular, Rollable, and Collapsible Deployable Composite Booms

High-strain composite deployable space structures are used for space infrastructure and science applications such as solar array supports, antennae, camera masts, and lightweight structures supporting solar sailing propulsion ele-ments. Triangular, Rollable, and Collapsible (TRAC) deployable composite booms are one example of a high-strain composite deployable structure and were studied using novel experimental test and characterization methods developed under the Gravity Offloading and Analysis of Long Imperfection-sensitive Ele-ments (GOALIE) project. In the present work, a subscale 7-m-long TRAC boom was suspended vertically to orient gravity along the length of the boom. By ori-enting vertically, highly nonlinear and unstable behavior often encountered dur-ing horizontally oriented gravity offload testing of similar structures was reduced. Pretest analytical predictions of TRAC booms indicated three unique failure modes, loads, and locations for three unique loading cases of in-plane bending, out-of-plane bending, and axial compression. To investigate the predicted behav-ior, an experimental test was set up to impart mechanical loads to a subscale TRAC boom. The experimental setup, loading cases, and instrumentation used to characterize the mechanical response of a subscale TRAC boom are described in this paper.

High-strain composites↗

Human Performance in Simulated Reduced Gravity Environments

NASA is currently designing a new space suit capable of working in deep space and on Mars. Designing a suit is very difficult and often requires trade‐offs between performance, cost, mass, and system complexity. Our current understanding of human performance in reduced gravity in a planetary environment (the moon or Mars) is limited to lunar observations, studies from the Apollo program, and recent suit tests conducted at JSC using reduced gravity simulators. This study will look at our most recent reduced gravity simulations performed on the new Active Response Gravity Offload System (ARGOS) compared to the C‐9 reduced gravity plane. Methods: Subjects ambulated in reduced gravity analogs to obtain a baseline for human performance. Subjects were tested in lunar gravity (1.6 m/sq s) and Earth gravity (9.8 m/sq s) in shirt‐sleeves. Subjects ambulated over ground at prescribed speeds on the ARGOS, but ambulated at a self‐selected speed on the C‐9 due to time limitations. Subjects on the ARGOS were given over 3 minutes to acclimate to the different conditions before data was collected. Nine healthy subjects were tested in the ARGOS (6 males, 3 females, 79.5 +/- 15.7 kg), while six subjects were tested on the C‐9 (6 males, 78.8 +/- 11.2 kg). Data was collected with an optical motion capture system (Vicon, Oxford, UK) and was analyzed using customized analysis scripts in BodyBuilder (Vicon, Oxford, UK) and MATLAB (MathWorks, Natick, MA, USA). Results: In all offloaded conditions, variation between subjects increased compared to 1‐g. Kinematics in the ARGOS at lunar gravity resembled earth gravity ambulation more closely than the C‐9 ambulation. Toe‐off occurred 10% earlier in both reduced gravity environments compared to earth gravity, shortening the stance phase. Likewise, ankle, knee, and hip angles remained consistently flexed and had reduced peaks compared to earth gravity. Ground reaction forces in lunar gravity (normalized to Earth body weight) were 0.4 +/- 0.2 on the ARGOS, but only 0.2 +/- 0.1 on the C‐9. Discussion: Gait analysis showed differences in joint kinematics and temporal‐spatial parameters between the reduced gravity simulators and with respect to earth gravity. Although most of the subjects chose a somewhat unique ambulation style as a result of learning to ambulate in a new environment, all but two were consistent with keeping an Earth‐like gait. Learning how reduced gravity affects ambulation will help NASA to determine optimal suit designs, influence mission planning, help train crew, and may shed light on the underlying methods the body uses to optimize gait for energetic efficiency. Conclusion: Kinematic and kinetic analysis demonstrated noteworthy differences between an offloaded environment and 1‐g, as would be expected. The analysis showed a trend to change the ambulation style in an offloaded environment to a rolling‐loping walk (resembling crosscountry skiing) with increased swing time. This ambulation modification, particularly in the ARGOS, indicated that the relative kinetic energy of the subject was increased, on average, per the static body weight compared to the 1‐g condition. How much of this was influenced by the active offloading of the ARGOS system is unknown.

Cowley, Matthew↗

A Preliminary Assessment of Cognition and Fatigue During Simulated Lunar Surface Extravehicular Activities

Introduction: Artemis astronauts will be required to complete more rigorous Extravehicular Activity (EVA) schedules than during ever before. While new spacesuits are designed to sustain high physical workloads during exploration EVAs (xEVA), crewmembers must also sustain cognitive performance throughout xEVA timelines. It is therefore necessary to characterize the effects of surface xEVA tasks and timelines on cognition and fatigue. Methods: This study utilized NASA Johnson Space Center’s Active Response Gravity Offload System (ARGOS) to simulate lunar gravity and assess xEVA tasks and cognitive performance. Two subjects completed two ~5-hour EVAs in a pressurized Mark III spacesuit, completing simulated lander operations, cable routing, crew rescue, geology, payload relocation, and traverses. Subjects completed two cognitive assessments (Digit-Symbol Substitution Task (DSST) and Psychomotor Vigilance Task (PVT)) before the first and after the second simulated EVA to assess effects of xEVA tasks on processing speed and vigilant attention. Additionally, sleep (e.g., quality, duration, and efficiency) was monitored (Oura Ring) for ≥7 days prior to the simulated EVAs, as well as between each EVA, to account for possible effects of sleep decrements on cognitive metrics. Results: Cognitive performance changed minimally from pre to post EVA for both DSST (response time (RT): S1 Δ129.1ms, S2 Δ40.7ms; Accuracy: S1 preEVA = 1.0, S1 postEVA = 0.98, S2 preEVA = 1.0, S2 postEVA = 1.0) and PVT (S1 PVT RT Δ17.7 ms, S2 PVT RT Δ-2.7 ms). Subjects’ sleep duration immediately prior to EVA showed minimal deviation from baseline (Δhrs; S1 preEVA1= + 0.67, S1 preEVA2 = -.03, S2 preEVA1 = - 1.1, S2 preEVA2 = -1.39) and efficiency (Δ%; S1 preEVA1 = 0.09, S1 preEVA2 = 9.54, S2 preEVA1 = 0, S2 preEVA2= 12). Notably, sleep waketime shifted earlier for one subject by ~1 hr which may have impacted performance. Conclusion: Understanding the impacts of xEVA workloads on cognitive performance will be instrumental to future exploration mission planning and success. Future work will expand the subject pool and test new spacesuit designs to better characterize cognitive performance and impacts of sleep during simulated xEVA and inform modeling and prediction capabilities for future Artemis xEVA planning.

Taylor E. Schlotman↗

A New Method for Interfacing Unsuited Subjects to Overhead Suspension Partial Gravity Simulators

The purpose of performing unsuited testing as part of a reduced gravity extravehicular (EVA) suited human performance research program is to define baseline performance. These results are then coupled with suited test results to evaluate how the suit system affects human performance at reduced gravity. The primary drawback to this approach is that previous studies used notably different systems to interface suited and unsuited subjects to overhead-suspension, partial-gravity simulators. A spreader bar (SB) assembly previously used for unsuited tests allowed limited pitch and roll of the subject, whereas the gimbal for suited tests allowed more pitch and roll, although the mass distribution led to large moments of inertia in the yaw axis. It is hypothesized that use of the same methods for offload of both unsuited and suited subjects is needed to make meaningful comparisons. A new gimbal (GIM) was designed with the idea that it could function with both suited and unsuited subjects. GIM was designed to minimize mass and moments of inertia and to be adjustable to co-locate the 3 axes of rotation with the subject s center of gravity. OBJECTIVE: To evaluate human performance differences between SB and GIM. METHODS: Ten unsuited subjects were offloaded to 1/6-g using both interfaces. Subjects completed tasks including overground and treadmill ambulation, picking up objects, shoveling, postural stability, range of motion testing, and recovery from the kneeling and prone positions. Metabolic, biomechanical, and/or subjective data were collected based on task. RESULTS: Initial analyses suggest that subjects completed all tasks with lower levels of compensation and a more terrestrial approach to movement when suspended via GIM. With SB, subjects were not able to fall or get into a prone position and had increased difficulty both retrieving objects off the floor and with overground ambulation, especially at gait initiation, because they were unable to bend their torso. GIM shows promise as a new method.

Norcross, Jason↗

Lessons Learned from Performance Testing of Humans in Spacesuits in Simulated Reduced Gravity

Introduction: The overarching objective of the Integrated Suit Test (IST) series is to evaluate suited human performance using reduced-gravity analogs and learn what aspects of an EVA suit system affect human performance. For this objective to be successfully achieved, the testing methodology should be valid and reproducible, and the partial-gravity simulations must be as accurate and realistic as possible. Objectives: To highlight some of the key lessons learned about partial-gravity analogs and testing methodology, and to suggest considerations for optimizing the effectiveness and quality of results of future tests. Methods: Performance testing of suited and unsuited subjects was undertaken in different reduced-gravity analogs including the Space Vehicle Mockup Facility s Partial Gravity Simulator (POGO), parabolic flight on the C-9 aircraft, underwater environments including NASA s Extreme Environment Mission Operations (NEEMO) and the Neutral Buoyancy Lab (NBL), and in field analogs including Desert Research and Technology Studies (RATS), the Haughton Mars Project (HMP), and the JSC Rock Pile. Subjects performed level walking, incline/decline walking, running, shoveling, picking up and transferring rocks, kneeling/standing, and task boards. Lessons Learned Analogs: No single analog will properly simulate all aspects of the true partial-gravity environment. The POGO is an ideal environment from the standpoint that there are no time limits or significant volumetric constraints, but it does have several limitations. It allows only 2 translational degrees of freedom (DOF) and applies true partial-gravity offload only through the subject s center of gravity (CG). Also, when a subject is doing non-stationary tasks, significant overhead inertia from the lift column seems to have a negative impact on performance. Parabolic flight allows full translational and rotational DOF and applies offload to all parts of the body, but the simulation lasts less than 30 seconds. When this is coupled with the volumetric constraints of the plane, both task selection and data collection options are significantly limited. The underwater environments also allow all 6 DOF and allow off-loading to be applied throughout the body, but the data collection capabilities are limited to little more than subjective ratings. In addition, water drag negatively affects performance of tasks requiring dynamic motion. Field analogs provide the ability to simulate lunar terrain and more realistic mission-like objectives, but all of them operate at 1-g, so suited human performance testing generally must utilize a reduced-mass or "mockup" suit, depending on study objectives. In general, the ground-based overhead-suspension partial-gravity analogs like POGO allow the most diverse data collection methods possible while still simulating partial gravity. However, as currently designed, the POGO has significant limitations. Design of the Active Response Gravity Offload System (ARGOS) has begun and is focusing on adding full x,y,z translational DOF, improved offload accuracy, increased lift capacity, and active control of the x and y axes to minimize offload system inertia. Additionally, a new gimbal is being designed to reduce mass and inertia and to be able to work with different suits, as the current gimbal only supports suited testing with the Mark III Technology Demonstrator Suit (MKIII).

Norcross, Jason R.↗

Modeling and Simulation Efforts to Support Improved Comfort in ARGOS

BACKGROUND: The Active Response Gravity Offload System (ARGOS) provides an analog environment for extravehicular activity (EVA) testing and training. Discomfort has been observed during longer suited test sessions. While the subject’s core is offloaded during surface EVA evaluations, his/her arms experience full Earth gravity and can become overly fatigued, especially during suited tests which involve reaching and prolonged arm extensions. A device (ARGOS Negation of Gravitational Effects on the Limbs: ANGEL) to offload the weight of the arms and suit sleeves is being developed by JSC’s Flight Systems Branch, and here we present preliminary modeling of that device using the open-source biomechanical tool OpenSim [1,2] with an in-house developed plugin. We analyze a series of motions performed by a single shirt-sleeved subject with goals of characterizing the device, validating the model, and predicting whether reduced gravity conditions (i.e., lunar gravity (Lg) or Martian gravity (Mg)) can be accurately simulated with the device, as well as providing comfort to the ARGOS user. METHODS AND RESULTS: To model the offload device, we augment the OpenSim human model topology with the offload mechanism components and joints, using CAD models to represent the mechanism graphically. The joint angles of the device are either obtained from (1) inverse kinematics (IK) using motion capture markers on the various components of the device or (2) calculated in the OpenSim plugin by modeling how the components configure themselves under the offloading spring tension given a particular IK-derived arm position. Given the joint angles of the device, the resulting force on the arm is computed by the plugin and applied as an external load in inverse dynamics (ID) in order to enable study of overall shoulder joint torques as well as offload achieved. We verify the calculated joint angles by using the inverse kinematic data and the forces from manual measurements of the spring both independently and integrated within the device. We found that calculated joint angles generally represent the angles measured and computed with IK, supporting a possible analysis workflow inputting human motion data and observing system behavior under varied design parameters. In two different device configurations in which the maximum applied force was 131 N, our current model accurately captured force with a difference of 2-3 N from measured loads. Though our initial test was performed with a shirt-sleeve subject, arm weights were added to emulate the weight of the suit sleeve and the subject was positioned in a test stand with a Mark-III Hard Upper Torso (HUT) and Portable Life Support System (PLSS) mockup. Arm range of motion tasks were performed outside of the HUT, inside the HUT, and inside the HUT while using the device. A variety of other upper body tasks were completed as well. In summary, we have developed a model to investigate and verify an upper limb offload device currently in development. We believe this model will be a valuable tool not only for device characterization but also to predict proper configurations to simulate Lg or Mg conditions, investigate range of motion concerns, predict limitations such as internal collisions and contacts, and inform future design improvements.

L B Nilsson↗

A New Method for Interfacing Unsuited Subjects to Overhead Suspension Partial Gravity Simulators

The purpose of performing unsuited testing as part of a reduced gravity extravehicular (EVA) suited human performance research program is to define baseline performance. These results are then coupled with suited test results to evaluate how the suit system affects human performance at reduced gravity. The primary drawback to this approach is that previous studies used notably different systems to interface suited and unsuited subjects to overhead-suspension, partial-gravity simulators. A spreader bar (SB) assembly previously used for unsuited tests allowed limited pitch and roll of the subject, whereas the gimbal for suited tests allowed more pitch and roll, although the mass distribution led to large moments of inertia in the yaw axis. It is hypothesized that use of the same methods for offload of both unsuited and suited subjects is needed to make meaningful comparisons. A new gimbal (GIM) was designed with the idea that it could function with both suited and unsuited subjects. GIM was designed to minimize mass and moments of inertia and to be adjustable to co-locate the 3 axes of rotation with the subject s center of gravity. OBJECTIVE: To evaluate human performance differences between SB and GIM. METHODS: Ten unsuited subjects were off-loaded to 1/6-g using both interfaces. Subjects completed tasks including overground and treadmill ambulation, picking up objects, shoveling, postural stability, range of motion testing, and recovery from the kneeling and prone positions. Metabolic, biomechanical, and/or subjective data were collected based on task. RESULTS: Initial analyses suggest that subjects completed all tasks with lower levels of compensation and a more terrestrial approach to movement when suspended via GIM. With SB, subjects were not able to fall or get into a prone position and had increased difficulty both retrieving objects off the floor and with overground ambulation, especially at gait initiation, because they were unable to bend their torso. GIM shows promise as a new method.

Norcross, Jason R.↗

Development of an Inertial Sensor-based Methodology for Spacesuited Geology Task Assessments during Simulated Lunar Extravehicular Activities

Lunar surface exploration during Artemis missions will require the specific skill set of geology sampling. Apollo astronauts had extensive training and used specialized tools to collect lunar rocks, core samples, pebbles, sand, and dust. The inflexibility of the pressurized Apollo spacesuits forced sampling to be taken at a standstill posture. However, new exploration spacesuits are expected to incorporate advanced materials and joint bearings, allowing for greater mobility and a wider range of functional postures. Thus, science and exploration during Artemis missions will likely involve a variety of standing, squatting, and kneeling postures. In preparation for future lunar exploration missions, NASA provides geologic training to astronauts and other mission personnel. This professional training with a spacesuit in simulated lunar environments will enhance performance and reduce risk of injury to astronauts on the lunar surface. However, anecdotally, untrained or newly trained people wearing prototype planetary spacesuits have been observed to performing motions differently than a trained geologist would when conducting the same geology sampling tasks. Therefore, a tool for evaluating geology postures at extravehicular activity (EVA) training facilities becomes required. In this paper, we introduce a novel inertial measurement unit (IMU)-based method of geology task assessments in spacesuited conditions during simulated lunar EVAs. As a case study, two subjects (one geologist and one non-geologist) participated and donned the Mark III prototype planetary spacesuit during offloading with the spreader bar gimbal in NASA’s Active Response Gravity Offload System (ARGOS). For automated geology task assessments, the spacesuit was instrumented with three wireless IMUs (APDM Opal, OR, USA): one on the chest and one each on the left and right ankle bearings. Then subjects performed geology tasks using various tools (rake, trench, hammer chisel, scoop, and drive tube) for 45 minutes each. The chest IMU measured the torso tilt angle in the sagittal plane. We used an ensemble learning method with the ankle IMUs to discriminate between standing and kneeling activities. IMU data were processed using custom MATLAB (Mathworks, MA, USA) software. In our case study, the developed method was able to discriminate differences in standing and kneeling activity levels between subjects who were all highly experienced with spacesuited testing. Our preliminary data showed one subject maintained the constant and lower range of the upper body tilt angle while both standing and kneeling, while the other subject showed more variation of the upper body tilt angle and preferred bending the upper body rather than changing from standing to kneeling posture and vice versa. While geology experience may be a factor, these results need further investigation as suit sizing and ARGOS offloading configurations have been proven to have a significant influence on suited ARGOS tasks. Also, more subjects will be needed to complete these tasks for validation. IMU-based geology task assessments can provide useful information for geology training programs. Additionally, our IMU-based posture analysis can provide new insights into how to evaluate spacesuited geology task characteristics of astronauts during simulated lunar EVAs.

Kyoung Jae Kim↗

The Instrumented Walking and Turning Test to Evaluate Suited Gait Dynamics and Performance in Extravehicular Activity Training Environments

Background and aims: Walking will be required for many exploration tasks on the Moon during the Artemis program. Walking in a straight line on the confined floorspace of a testing area, and repetitive treadmill walking that requires no change in direction may not adequately reflect the balance and coordination required during ambulation. Also, performance of turning maneuvers may be affected differently in different extravehicular activity (EVA) training facilities that simulate partial gravity. For example, the Neutral Buoyancy Lab (NBL) simulates lunar gravity by adding weight to underwater subjects to alter buoyancy and achieve the equivalent ground reaction force of 1/6 of Earth’s gravity (1/6G), whereas the Active Response Gravity Offload System (ARGOS) uses a computer controlled overhead suspension system programmed to continuously offload a percentage of a subject’s weight to simulate 1/6G. The degree to which dynamic movements such as turning are comparable across these EVA training facilities has not yet been evaluated. The instrumented gait test helps NASA scientists and engineers evaluate gait dynamics and performance in suited conditions, and this test demonstrates the unique characteristics and limitations of EVA training facilities. We developed an instrumented walking and turning test using inertial measurement units (IMUs) and conducted the test at NASA’s EVA training facilities. Results were used to compare suited walking and turning characteristics in the ARGOS and the NBL. Methods: Subjects donned the Mark III space suit during offloading with the ARGOS spreader bar gimbal and donned the Z2.5 space suit while underwater in the NBL with weights and floatation added to achieve realistic suit center of gravity. The test team securely attached three Opal (APDM, OR, USA) wireless IMUs on the space suit for each test run: one on the middle of the hard upper torso, and one on the left and on the right ankle bearings. During the NBL tests, the IMUs were encased in a waterproof housing (GoPro) with foam added to create a tighter fit. At both testing facilities, 6.3 m x 1.0 m (LxW) walking lines were marked, and a cone for turning or walking around was located at the end of the walking path with another line on the other side of the cone to indicate the stopping point after walking around the cone. Under simulated 1/6G, subjects began by standing at the marked line with their arms folded across the chest, they then walked at a preferred speed along the straight walking path until they reached the end, turned 180 degrees around the cone, and finally stopped at the marked stopping point. All IMU data recorded during testing were automatically saved to the internal memory. Then, raw IMU signals were processed using custom MATLAB (Mathworks, MA, USA) code to compare gait parameters during both the walking and the turning components of the task. These parameters included time (s), speed (m/s for walking and rad/s for turning), step number (n) and walk:turn time ratio (% time spent straight walking versus turning). Results: Less time, faster gait, fewer steps, and higher walk:turn ratio during both walking and turning components were exhibited during tests performed at the ARGOS versus those performed at the NBL. During the NBL tests, the slower walking speed continued at the same rate throughout a U-shape turn. During the ARGOS tests, the subjects performed shorter and tighter turns at 4 times the speed of the NBL turns because they walked 30% faster and the vertical offloading system gave them more support. Conclusion: Our data show that the differences in walking and turning parameters during the NBL tests may be due to the high viscosity in the water environment where the motion of the lower limbs was slow and did not reach full flexion and extension. These tests improve the current knowledge of testing environments in preparation for EVAs on the lunar surface.

Kyoung Jae Kim↗

Evaluation of Aerobic Capacity in Relation to Simulated Lunar Surface Extravehicular Activities

INTRODUCTION Astronauts will need to be physically prepared to successfully execute strenuous Extravehicular Activities (EVA)on the Lunar surface. Compared to Apollo missions, Artemis missions will include EVAs of increased physical demand, frequency, and duration, thus requiring adequate fitness to successfully and safely complete mission objectives and potential contingency scenarios. Currently, aerobic fitness standards for partial gravity (g)surface EVAs are not well supported by high-fidelity EVA analog data. This investigation aims to characterize metabolic demands from Lunar analog EVA simulations in relation to the current NASA standards for celestial partial-g aerobic fitness(aerobic capacity (VO2pk) ≥36.5ml/kg/min). METHODS To evaluate current Lunar EVA aerobic fitness requirements, a pilot study was performed to characterize metabolic ratesduring6 hour simulated EVAs. The EVAs were performed in pressurized MKIII (n=2male) and xEMU (n=3 female) spacesuits offloaded to 1/6 g in the NASA Active Response Gravity Offload System. VO2pk was assessed via graded exercise testing on acycle ergometer and physical workload was quantified as percent ofVO2pk. RESULTS Four out of five subjects did not meet the current NASA celestial surface EVA aerobic standard (3 xEMU, 1MKIII;35.1±0.9 ml/kg/min). During simulated EVAs, subjects (xEMU: 35±1ml/kg/min; MKIII: 44±10ml/kg/min) worked at an average 36%VO2pk(xEMU) and 31% VO2pk(MKIII). For xEMU subjects, the tasks with the greatest average metabolic rates were 2km treadmill traverse(0% grade: 47.2%VO2pk[max 69.1%]), object relocation (45.2%VO2pk[max 60.5%]), and 1.5km traverse (0% grade: 45%VO2pk[max 59.7%]). For MKIII subjects, the tasks with the greatest average metabolic rates were 0.5km treadmill traverse (30% grade: 35.4% VO2pk[max 45.5%]), object relocation(31% VO2pk[max 40.8%]), and treadmill traverse (0% grade: 29.9%VO2pk[max 45.9%]). CONCLUSIONS While average metabolic rates for simulated Lunar EVA fall within sustainable work ranges of30–40% VO2pkand life support system limitations, task-specific metabolic rates exceed this range and may indicate that greater fitness is necessary for more strenuous tasks expected to be performed on the Lunar surface. As few subjects met the standard, more data is needed to adequately evaluate the NASA 3001 standard.

N C Strock↗

NASA Space Environment Analog for Training, Engineering, Science, and Technology (SEATEST) 6 Detailed Final Report

After more than 50 years since the last crewed lunar landing, plans for more missions to the moon are in development. For these missions, efficient and sustainable logistics will be critical. Additionally, innovative methods of cargo transfer to and from a lunar outpost should be considered for successfully establishing a permanent presence on the moon. SEATEST (Space Environment Analog for Training, Engineering, Science, and Technology) is an immersive mission-analogous operational atmosphere where buoyancy effects and supplemental weights can simulate partial gravity conditions similar to those astronauts will experience on the moon. SEATEST 6 took place at the University of Southern California (USC) Wrigley Marine Science Center on Santa Catalina Island from July 18-30, 2023. The analog was used to collect preliminary logistics data on two different offloading conceptual methods (a davit and a zipline) during a simulated lunar mission. Pre-test analysis indicated for a crew of two on a 14-day mission, approximately three Medium Pressurized Logistics Containers (MPLC) sized logistics containers (or a total of 37.5 single Cargo Transfer Bag Equivalents (CTBE)) would be needed to support a mission. A Computer-Aided Design (CAD) analysis was employed on the SEATEST airlock mockup to determine how many logistic containers would fit with two suited crewmembers, don/doff stands, and hatch operations. It was determined that for SEATEST, a total of 15 1.0 Small Pressurized Logistics Containers (SPLCs) and 8 2.0 SPLCs would adequately fit into the approximate 9.5 cubic meter airlock volume. This does not fully represent a complete 14-day logistic supply; however, it does provide a preliminary estimate to initiate design conversations between logistics teams and crew at this early stage of development. Data were collected in eight logistics transfer scenarios over two days with four scenarios per day. Five test subject crew participated in scenarios as pairs. Scenarios included two sizes of logistics containers – 1.0 SPLC (equivalent to a single Cargo Transfer Bag (CTB) and 2.0 SPLC (equivalent to two CTBs). Planed evaluations included the use of a logistics port compared to transfer through an Airlock hatch, offloading methods based on either a davit or a zipline system, choreography of cargo in the airlock to permit ingress and suit doffing, and dust removal protocols for an understanding of the overall impact to transfer ops. Data collected included objective data (task times for conducting overall tasks and subtasks, full audio/video of test activities, and inadvertent “dings” on hardware) and subjective data (crew consensus of: task acceptability and capability assessment ratings related to best practices, considerations, and constraints for EVA-driven logistics transfer ConOps, sim quality of the test environment, and more general debrief comments). The two logistic offloading transfer concepts (davit, zipline) presented both advantages and limitations. The davit’s flexibility in allowing the crew to pick up the containers without physical interaction was well regarded by the crew. Some limitations of select davit hardware components were noted, but the overall concept was acceptable. The zipline system proved to be the most efficient way of moving logistics from the lander to the airlock and eliminated the need for dust operations. However, extended and repetitive lifting of containers to the line could be fatiguing. In conclusion, logistics transfer could hypothetically be achieved without an offloading method; however, the time requirement for such operations would be prohibitive. Results of crew subjective feedback proposed a combined or hybrid davit/zipline method to increase efficiency.

Logistics↗

Evaluation of Aerobic Standards for Lunar Surface Extravehicular Activities

Introduction: As NASA prepares to return to the Moon, astronauts will need to be physically primed to successfully execute Extravehicular Activities (EVA) on the Lunar surface. Compared to past Apollo missions, Artemis missions will include EVAs of increased physical demand, frequency, intensity, and duration, thus requiring adequate fitness to successfully and safely complete mission objectives. The physical demand associated with partial gravity (g) EVAs on the Moon is expected to be greater compared to microgravity EVAs based on initial workload estimation. Currently, aerobic fitness standards for partial g EVAs are not well supported by high-fidelity data and require further research for establishing standards to protect crew health and performance during Lunar surface missions. Therefore, the aim of this investigation is to characterize metabolic data from Lunar analog simulations and in-flight crew population aerobic capacity data to validate the current NASA 3001 standard for celestial partial g aerobic fitness (aerobic capacity (VO_2pk) ≥36.5ml/kg/min). Methods: In order to evaluate aerobic fitness requirements for Lunar EVAs, the following were performed: 1) preliminary analysis of long-duration (6 hr) EVA analog simulations in the Neutral Buoyancy Laboratory (NBL) and the Active Response Gravity Offload System (ARGOS) to evaluate expected metabolic rates for 1/6 g EVAs (NBL: n=1 female; ARGOS: n=1 male) and 2) assessment of the current NASA 3001 celestial surface EVA aerobic standard (aerobic capacity (VO_2pk) ≥36.5ml/kg/min) with data from an ISS astronaut population (n=30 male + 13 female) captured before and during space flight (flight day 15). Preliminary Results: Average fractional aerobic capacity during simulated EVAs were 33%±7% VO_2pk and 23.3±7% VO_2pk in the NBL and ARGOS, respectively. This was within a previously predicted 30–40% sustainable work rate. Average metabolic rates for some tasks performed in the NBL, such as traverse (40.4% VO_2pk) and ingress (47.1% VO_2pk) were higher than the predicted sustainable work range. In ARGOS, the tasks with the greatest metabolic rates were object relocation (34.2% VO_2pk) and incapacitated crew rescue (27.0% VO_2pk). Characterization of ISS crewmember aerobic capacity determined that the average preflight VO_2pk was 42.1±5.4 ml/kg/min for females and 37.5±5.4 ml/kg/min for males. At preflight, 21.5% of crewmembers were below the 36.5 ml/kg/min in-mission aerobic standard for celestial surface EVA as outlined in NASA-STD-3001. In-flight, both female and male crewmembers experienced reductions in VO_2pk (11.7% and 10.9%, respectively), such that, during the mission, 62% of crewmembers were below the standard aerobic capacity level for celestial surface EVAs. Conclusions: Our preliminary data suggest that while average metabolic rates for simulated Lunar EVA fall within the 30–40% sustainable work range, task specific metabolic rates exceed this range and may indicate that greater fitness is necessary for more strenuous tasks expected to be performed on the Lunar surface. Additionally, deconditioning due to space flight results in most crewmembers falling below the current celestial partial g EVA standard, which may increase risk to crew health and performance and completing mission objectives for surface missions. Further research is necessary in Artemis-specific analog environments to validate the current NASA-3001 aerobic standard for celestial EVAs. Additionally, work is ongoing to validate the current NASA-3001 strength standard for celestial EVAs.

N.C. Strock↗