Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gravimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Determining the tilt of the Raman laser beam using an optical method for atom gravimeters

The tilt of a Raman laser beam is a major systematic error in precision gravity measurement using atom interferometry. The conventional approach to evaluating this tilt error involves modulating the direction of the Raman laser beam and conducting time-consuming gravity measurements to identify the error minimum. In this work, we demonstrate a method to expediently determine the tilt of the Raman laser beam by transforming the tilt angle measurement into characterization of parallelism, which integrates the optical method of aligning the laser direction, commonly used in freely falling corner-cube gravimeters, into an atom gravimeter. A position-sensing detector (PSD) is utilized to quantitatively characterize the parallelism between the test beam and the reference beam, thus measuring the tilt precisely and rapidly. After carefully positioning the PSD and calibrating the relationship between the distance measured by the PSD and the tilt angle measured by the tiltmeter, we achieved a statistical uncertainty of less than 30 µrad in the tilt measurement. Furthermore, we compared the results obtained through this optical method with those from the conventional tilt modulation method for gravity measurement. The comparison validates that our optical method can achieve tilt determination with an accuracy level of better than 200 µrad, corresponding to a systematic error of 20 µGal in g measurement. This work has practical implications for real-world applications of atom gravimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A three-dimension active vibration isolator for precision atom gravimeters

An ultra-low frequency active vibration isolator, simultaneously suppressing three-dimensional vibration noise, is demonstrated experimentally. The equivalent natural period of the isolator is 100 s and 12 s for the vertical and horizontal direction, respectively. The vibration noise in the vertical direction is about 50 times reduced during 0.2 and 2 Hz, and 5 times reduced in the other two orthogonal directions in the same frequency range. This isolator is designed for atom gravimeters, especially suitable for the gravimeter whose sensitivity is limited by vibration couplings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a frequency-dependent phase shift in chirped Raman lasers for atom gravimeters

Light-pulse atom gravimetry has emerged as a powerful technique for precisely measuring absolute gravitational acceleration. Raman lasers are commonly used in this technique to coherently manipulate the atomic wave packet, of which the effective frequency is chirped continuously to compensate for the Doppler shift. In this study we investigate an additional phase shift in the Raman lasers that arises due to the frequency chirp. Here, we directly measure this phase shift by recording the beat signal of the Raman lasers with a high-speed oscilloscope, providing an independent evaluation of the resultant error in atom gravimeters caused by this phase shift. Concurrently, we detect the influence of the additional phase shift on gravity measurements using our atom gravimeter, and the results are in good agreement with the independent evaluation. Notably, there may still be a residual error at the microgal level when performing differential measurements by reversing the direction of the effective wave vector of the Raman lasers. We propose that this residual error can in principle be eliminated by selecting the same chirp frequency range for both directions in the differential measurement.

Xu, Yaoyao [Huazhong Univ. of Science and Technolo↗

Double diffraction in an atomic gravimeter

We demonstrate the realization of a scheme for cold-atom gravimetry based on the recently demonstrated use of double-diffraction beam splitters [T. Leveque, A. Gauguet, F. Michaud, F. Pereira Dos Santos, and A. Landragin, Phys. Rev. Lett. 103, 080405 (2009)], where the use of two retro-reflected Raman beams allows symmetric diffraction in +-(Planck constant/2pi)k{sub eff} momenta. Although in principle restricted to the case of zero Doppler shift, for which the two pairs of Raman beams are simultaneously resonant, such diffraction pulses can remain efficient on atoms with nonzero velocity, such as in a gravimeter, when the frequency of one of the two Raman laser sources is modulated. Such pulses are used to realize an interferometer insensitive to laser phase noise and some of the dominant systematics. This approach reduces the technical requirements and would allow the realization of a simple atomic gravimeter. A sensitivity of 1.2x10{sup -7}g per shot is demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gravimeter Search for Compact Dark Matter Objects Moving in the Earth

Dark matter could be composed of compact dark objects (CDOs). These objects may interact very weakly with normal matter and could move freely inside the Earth. A CDO moving in the inner core of the Earth will have an orbital period near 55 min and produce a time-dependent signal in a gravimeter. Data from superconducting gravimeters rule out such objects moving inside the Earth unless their mass m D and or orbital radius a are very small so that m D a < 1.2 × 10 - 13 M ⊕ R ⊕ . Here, M ⊕ and R ⊕ are the mass and radius of the Earth, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gravity surveys using a mobile atom interferometer

Mobile gravimetry is important in metrology, navigation, geodesy, and geophysics. Atomic gravimeters could be among the most accurate mobile gravimeters but are currently constrained by being complex and fragile. Here, we demonstrate a mobile atomic gravimeter, measuring tidal gravity variations in the laboratory and surveying gravity in the field. The tidal gravity measurements achieve a sensitivity of 37 μGal/ Hz (1 μGal = 10 nm/s 2 ) and a long-term stability of better than 2 μGal, revealing ocean tidal loading effects and recording several distant earthquakes. We survey gravity in the Berkeley Hills with an uncertainty of around 0.04 mGal and determine the density of the subsurface rocks from the vertical gravity gradient. With simplicity and sensitivity, our instrument paves the way for bringing atomic gravimeters to field applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gravity Survey of the Carson Sink - Data and Maps

A detailed gravity survey was carried out for the entire Carson Sink in western Nevada (Figure 1) through a subcontract to Zonge Engineering, Inc. The Carson Sink is a large composite basin containing three known, blind high-temperature geothermal systems (Fallon Airbase, Stillwater, and Soda Lake). This area was chosen for a detailed gravity survey in order to characterize the gravity signature of the known geothermal systems and to identify other potential blind systems based on the structural setting indicated by the gravity data. Data were acquired at approximately 400, 800, and 1600 meter intervals for a total of 1,243 stations. The project location and station location points are presented in Figure 14. The station distribution for this survey was designed to complete regional gravity coverage in the Carson Sink area without duplication of available public and private gravity coverage. Gravity data were acquired using a Scintrex CG-5 gravimeter and a LaCoste and Romberg (L&R) Model-G gravimeter. The CG-5 gravity meter has a reading resolution of 0.001 milligals and a typical repeatability of less than 0.005 milligals. The L&R gravity meter has a reading resolution of 0.01 milligals and a typical repeatability of 0.02 milligals. The basic processing of gravimeter readings to calculate through to the Complete Bouguer Anomaly was made using the Gravity and Terrain Correction software version 7.1 for Oasis Montaj by Geosoft LTD. The gravity survey of the Carson Sink yielded a project location and station location map, a Complete Bouguer Anomaly @ 2.67 gm/cc reduction density, a Gravity Complete Bouguer Anomaly at 2.50 g/cc Contour Map, a Gravity Horizontal Gradient Magnitude Shaded Color Contour Map, a Gravity 1st Vertical Derivative Color Contour Map, and an Interpreted Depth to Mesozoic Basement incorporating drill-hole intercept values. A preliminary interpretation of these results suggests that the Carson Sink is a complex composite basin with several major depocenters. Major depocenters are present in the south-central, east-central, and northeastern parts of the basin. The distribution of gravity anomalies suggests a complex pattern of faulting in the subsurface of the basin, with many fault terminations, step-overs, and accommodation zones. The pattern of faulting implies that other, previously undiscovered blind geothermal systems are likely in the Carson Sink. The gravity survey was completed near the end of this project. Thus, more thorough analysis of the data and potential locations of blind geothermal systems is planned for future work.

15 GEOTHERMAL ENERGY↗

Proposal for a geophysical search for dilatonic waves

We propose a new method of searching for the composition-dependent dilatonic waves, predicted by unified theories of strings. In this method, Earth's surface-gravity changes due to translational motions of its inner core, excited by dilatonic waves, are searched for by using superconducting gravimeters. This method has its best sensitivity at the frequency of {approx}7x10{sup -5} Hz, which is lower than the sensitive frequencies of previous proposals using gravitational wave detectors: {approx}10 to 1000 Hz. Using available results of surface-gravity measurements with superconducting gravimeters and assuming a simple Earth model, we present preliminary upper limits on the energy density of a stochastic background of massless dilatons at the low frequency. Though the results are currently limited by the uncertainty in the Earth model, this method has a potential of detecting dilatonic waves in a new window.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A compact cold-atom interferometer with a high data-rate grating magneto-optical trap and a photonic-integrated-circuit-compatible laser system

Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here, we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 μK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0–4.5 ms interrogation time, resulting in Δ g / g = 2.0 × 10 −6 . This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quantum sensing for emerging energy technologies

The ability to exploit quantum phenomena has enabled sensing technologies with detection limits below the classical limit. Sensors with applications in energy discovery, production, transportation, and consumption can be enhanced through quantum or hybrid quantum-classical sensors. Here, in this Review, we provide an overview of commercial and emerging quantum sensor platforms and their opportunity areas specific to advanced energy technologies. Key examples include: power grid-enhancing-technologies, where quantum magnetometers can detect powerline and transformer faults; electric vehicle-to-grid applications, where chip-scale atomic clocks can enable grid synchronization; and carbon capture and storage, where quantum gravimeters and single-photo LiDAR can detect microscopic leaks. Quantum sensor deployment requires further research into miniaturization and ruggedization for field deployment, cost-reduction, and workforce development. The maturation of clean energy technologies and quantum sensors provide opportunities for synergy, with the integration of quantum sensors into advanced energy technologies maximizing their security, reliability, and efficiency.

critical metals↗

The application of Raman laser in gravity measurement and metrology

Atom Interferometry is proved to be a potential method for measuring the acceleration of atoms due to Gravity, we are now building a feasible system of cold atom gravimeter, it is based on the atom interferometry technology by coherently manipulating the cold atoms in a fountain (with a height of 1m) with specific Raman lasers, the cold atom wave packet is splitted, combined, and then re-splitted in the process. Then the atomic wave packet will acquire different phase because of the different evolution path. The precise acceleration can be deduced through the precision measurement of atomic interference fringes phase, and this will be a high precision standard of acceleration. At present, the preparation of Raman laser and the precise control of the laser Frequency have been finished, and they have been proved to meet the requirements of the experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: Directly measuring the direct digital synthesizer frequency chirp-rate for an atom interferometer

During gravity measurements with Raman type atom interferometry, the frequency of the laser used to drive Raman transition is scanned by chirping the frequency of a direct digital synthesizer (DDS), and the local gravity is determined by precisely measuring the chip rate α of DDS. We present an effective method that can directly evaluate the frequency chirp rate stability of our DDS. By mixing a pair of synchronous linear sweeping signals, the chirp rate fluctuation is precisely measured with a frequency counter. The measurement result shows that the relative α instability can reach 5.7 × 10{sup −11} in 1 s, which is neglectable in a 10{sup −9} g level atom interferometry gravimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Growing barium hexaferrite (BaFe{sub 12}O{sub 19}) thin films using chemical solution deposition

Barium hexaferrite (BaFe{sub 12}O{sub 19}, or simply known as BaM) thin films has been recognized as a potential candidate for microwave-based devices, magnetic recording media and data storage. To grow BaM thin films, chemical solution deposition is conducted using the aqueous solution of metal nitrates, which involves spin coatings on Si substrates. Furthermore, Thermal Gravimeter Analysis (TGA), X-Ray Diffractometer (XRD), Scanning Electron Microscopy (SEM) and Vibrating Sample Magnetometer (VSM) are applied to evaluate the decomposition behavior, structure, morphology, and magnetic properties of BaM thin films. Additionally, the effects of number of layers variation are also investigated. Finally, magnetic properties analysis indicates the isotropic nature of the films.

36 MATERIALS SCIENCE↗

Key technologies and applications of laser cooling and trapping {sup 87}Rb atomic system

Atom Interferometry is proved to be a potential method for measuring the acceleration of atoms due to Gravity, we are now building a feasible system of cold atom gravimeter. In this paper development and the important applications of laser cooling and trapping atoms are introduced, some key techniques which are used to obtain {sup 87}Rb cold atoms in our experiments are also discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cold-atom gravimetry with a Bose-Einstein condensate

We present a cold-atom gravimeter operating with a sample of Bose-condensed {sup 87}Rb atoms. Using a Mach-Zehnder configuration with the two arms separated by a two-photon Bragg transition, we observe interference fringes with a visibility of (83{+-}6)% at T=3 ms. We exploit large momentum transfer (LMT) beam splitting to increase the enclosed space-time area of the interferometer using higher-order Bragg transitions and Bloch oscillations. We also compare fringes from condensed and thermal sources and observe a reduced visibility of (58{+-}4)% for the thermal source. We suspect the loss in visibility is caused partly by wave-front aberrations, to which the thermal source is more susceptible due to its larger transverse momentum spread. Finally, we discuss briefly the potential advantages of using a coherent atomic source for LMT, and we present a simple mean-field model to demonstrate that with currently available experimental parameters, interaction-induced dephasing will not limit the sensitivity of inertial measurements using freely falling, coherent atomic sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atom interferometry tests of local Lorentz invariance in gravity and electrodynamics

We present atom-interferometer tests of the local Lorentz invariance of post-Newtonian gravity. An experiment probing for anomalous vertical gravity on Earth, which has already been performed, uses the highest-resolution atomic gravimeter so far. The influence of Lorentz violation in electrodynamics is also taken into account, resulting in combined bounds on Lorentz violation in gravity and electrodynamics. Expressed within the standard model extension or Nordtvedt's anisotropic universe model, we limit 12 linear combinations of seven coefficients for Lorentz violation at the part per billion level, from which we derive limits on six coefficients (and seven when taking into account additional data from lunar laser ranging). We also discuss the use of horizontal interferometers, including atom-chip or guided-atom devices, which potentially allow the use of longer coherence times in order to achieve higher sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cold atoms in space: community workshop summary and proposed road-map

We summarise the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, and atom interferometers. Prospective applications include metrology, geodesy and measurement of terrestrial mass change due to, e.g., climate change, and fundamental science experiments such as tests of the equivalence principle, searches for dark matter, measurements of gravitational waves and tests of quantum mechanics. We review the current status of cold atom technologies and outline the requirements for their space qualification, including the development paths and the corresponding technical milestones, and identifying possible pathfinder missions to pave the way for missions to exploit the full potential of cold atoms in space. Finally, we present a first draft of a possible road-map for achieving these goals, that we propose for discussion by the interested cold atom, Earth Observation, fundamental physics and other prospective scientific user communities, together with the European Space Agency (ESA) and national space and research funding agencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗