Neutron Grating Interferometry at the High Flux Isotope Reactor

Neutron imaging is a non-destructive probe that can spatially resolve bulk materials’ internal features/structures. Neutron imaging spatial resolution is driven by detector technology, i.e., pixel size, and is currently on the order of 10–20 µm. This limitation can be alleviated by the use of neutron grating interferometry – an advanced neutron imaging technique – that enables simultaneous access to three contrast mechanisms: attenuation, differential phase, and small-angle neutron scattering. Recently, a Talbot-Lau neutron grating interferometry has been implemented at the Multimodal Advanced Radiography Station at the High Flux Isotope Reactor. In this work, the design, setup and performance of the grating apparatus are presented.

Zhang, Yuxuan [ORNL] (ORCID:0000000200831408)↗

In Situ Visualization of Li-Whisker with Grating-Interferometry-Based Tricontrast X-ray Microtomography

The lithium-ion battery has demonstrated tremendous economic and social impacts. Upon battery operation under different conditions, lithium changes its chemical state and physical formation, leading to undesired side reactions, e.g., lithium dendrite growth that degrades the cell performance and causes safety concerns. In situ detection and visualization of lithium metal in functional batteries could offer insights with both scientific and industrial significance but remain a frontier challenge. In this work, we demonstrate in situ three-dimensional imaging of lithium whisker using a grating-interferometry-based tricontrast X-ray microtomography method. Our approach explicitly reveals the micromorphology of the electrochemically developed porous lithium whisker with micrometer-level spatial resolution while offering sensitivity to the nanoporosity that is smaller than the nominal resolution limit. Our result reveals valuable structural information on the lithium whisker that is otherwise inaccessible. This method is also readily applicable to a broad range of battery research, including all-solid-state batteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron Imaging Using Grating Interferometry: Exploiting phase contrast and dark-field imaging for <1μm feature detection in bulk materials (Summary Report)

Radiography is an important non-destructive characterization tool for many LANL missions. Contrast in conventional radiography results from attenuation of the incoming x-ray or neutron beam by the object. Neutrons have a great benefit in detecting light elements (e.g. hydrogen) in the presence of heavier elements and penetrate deeper than X-rays into many materials, but neutron radiography resolution is typically limited to ~50 μm. Cracks, voids, pores and a variety of other features smaller than this resolution are therefore undetectable in attenuation based neutron imaging. However, novel neutron imaging modalities leveraging off of interferometric methods, so-called neutron grating interferometry (NGI), are able to spatially map sub-micron features and interfacial features while also exploiting the neutron’s sensitivity to light elements and isotope specific contrast to enable material characterization otherwise impossible.

36 MATERIALS SCIENCE↗

Intact, Commercial Lithium-Polymer Batteries: Spatially Resolved Grating-Based Interferometry Imaging, Bragg Edge Imaging, and Neutron Diffraction

We survey several neutron imaging and diffraction methods for non-destructive testing and evaluation of intact, commercial lithium-ion batteries. Specifically, far-field interferometry was explored as an option to probe a wide range of autocorrelation lengths within the batteries via neutron imaging. The dark-field interferometry images change remarkably from fresh to worn batteries, and from charged to discharged batteries. When attempting to search for visual evidence of battery degradation, neutron Talbot-Lau grating interferometry exposed battery layering and particle scattering through dark-field imaging. Bragg edge imaging also reveals battery wear and state of charge. Neutron diffraction observed chemical changes between fresh and worn, charged and discharged batteries. However, the utility of these methods, for commercial batteries, is dependent upon battery size and shape, with 19 to 43 mAh prismatic batteries proving most convenient for these experimental methods. This study reports some of the first spatially resolved, small angle scattering (dark-field) images showing battery degradation.

36 MATERIALS SCIENCE↗

Theoretical and experimental analysis of the modulated phase grating X-ray interferometer

X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.

47 OTHER INSTRUMENTATION↗

Measurements of source emittance and beam coherence properties of the upgraded Advanced Photon Source

The Advanced Photon Source (APS) has been upgraded with a multi-bend achromat lattice, achieving significantly reduced electron beam emittance and enhanced X-ray coherence. Precise characterization of these properties is essential for optimizing beamline performance and enabling new experiments that take full advantage of the upgraded source. We report on measurements of source size and transverse coherence properties using grating interferometry at two beamlines: the APS 3-ID-B undulator beamline and the 1-BM-B bending magnet beamline. The results confirm the world-record horizontal emittance of the upgraded APS below 30 pm rad and validate the theoretical design parameters. We further investigate the impact of optical aberrations and mechanical vibrations at the 12-ID-C beamline on coherence preservation. These measurements establish a benchmark for future beamline enhancements and demonstrate the effectiveness of grating interferometry for high-precision beam characterization. Our findings provide critical insights into synchrotron beam dynamics, coherence degradation mechanisms, and strategies for optimizing beamline X-ray optics at next-generation light sources.

Advanced Photon Source↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reflective binary amplitude grating for soft x-ray shearing and Hartmann wavefront sensing

Here, we demonstrate a reflective wavefront sensor grating suitable for the characterization of high-quality x-ray beamlines and optical systems with high power densities. Operating at glancing incidence angles, the optical element is deeply etched with a two-level pattern of shearing interferometry gratings and Hartmann wavefront sensor grids. Transverse features block unwanted light, enabling binary amplitude in reflection with high pattern contrast. We present surface characterization and soft x-ray reflectometry of a prototype grating array to demonstrate function prior to wavefront measurement applications. A simulation of device performance is shown.

47 OTHER INSTRUMENTATION↗

A large field-of-view high-resolution hard x-ray microscope using polymer optics

Here, we present an effective approach using a matched pair of polymer-based condenser-objective lenses to build a compact full-field X-ray microscope with a high spatial resolution. A unique condenser comprising arrays of high-aspect-ratio prisms with equilateral cross-section is used for uniformly illuminating samples over a large field of view (FoV) from all angles, which match the acceptance of an objective made of interdigitated orthogonal rows of one-dimensional lenses. State-of-the-art Talbot grating interferometry used to characterize these lenses for the first time revealed excellent focusing properties and minimal wave-front distortions. Using a specific lens-pair designed for 20 keV X-rays, short-exposure times, and image registration with a cross-correlation technique, we circumvent vibrational instabilities to obtain distortion-free images with a uniform resolution of 240 nm (smallest resolvable line pair) over a large FoV, 80 × 80 µm 2 in extent. The results were contrasted with those collected under illumination using commercial two-dimensional parabolic lenses with a smaller FoV. This approach implemented on a diffractometer would enable diffraction-contrast or dark-field microscopy for fast observations of ‘mesoscopic’ phenomena in real space complementing reciprocal-space studies using diffraction on the same instrument.

47 OTHER INSTRUMENTATION↗

The Complex, Unique, and Powerful Imaging Instrument for Dynamics (CUPI 2 D) at the Spallation Neutron Source (invited)

The Oak Ridge National Laboratory is planning to build the Second Target Station (STS) at the Spallation Neutron Source (SNS). STS will host a suite of novel instruments that complement the First Target Station’s beamline capabilities by offering an increased flux for cold neutrons and a broader wavelength bandwidth. A novel neutron imaging beamline, named the Complex, Unique, and Powerful Imaging Instrument for Dynamics (CUPI 2 D), is among the first eight instruments that will be commissioned at STS as part of the construction project. CUPI 2 D is designed for a broad range of neutron imaging scientific applications, such as energy storage and conversion (batteries and fuel cells), materials science and engineering (additive manufacturing, superalloys, and archaeometry), nuclear materials (novel cladding materials, nuclear fuel, and moderators), cementitious materials, biology/medical/dental applications (regenerative medicine and cancer), and life sciences (plant–soil interactions and nutrient dynamics). The innovation of this instrument lies in the utilization of a high flux of wavelength-separated cold neutrons to perform real time in situ neutron grating interferometry and Bragg edge imaging—with a wavelength resolution of δλ/λ ≈ 0.3%—simultaneously when required, across a broad range of length and time scales. This manuscript briefly describes the science enabled at CUPI 2 D based on its unique capabilities. The preliminary beamline performance, a design concept, and future development requirements are also presented.

47 OTHER INSTRUMENTATION↗

Phase and contrast moiré signatures in two-dimensional cone beam interferometry

Neutron interferometry has played a distinctive role in fundamental science and characterization of materials. Moiré neutron interferometers are candidate next-generation instruments: they offer microscopy-like magnification of the signal, enabling direct camera recording of interference patterns across the full neutron wavelength spectrum. Here we demonstrate the extension of phase-grating moiré interferometry to two-dimensional geometries. Our fork-dislocation phase gratings reveal phase singularities in the moiré pattern, and we explore orthogonal moiré patterns with two-dimensional phase gratings. Our measurements of phase topologies and gravitationally induced phase shifts are in good agreement with theory. These techniques can be implemented in existing neutron instruments to advance interferometric analyses of emerging materials and precision measurements of fundamental constants. Published by the American Physical Society 2024

Sarenac, D. (ORCID:0000000185753367)↗

High-resolution multicontrast tomography with an X-ray microarray anode–structured target source

Multicontrast X-ray imaging with high resolution and sensitivity using Talbot–Lau interferometry (TLI) offers unique imaging capabilities that are important to a wide range of applications, including the study of morphological features with different physical properties in biological specimens. The conventional X-ray TLI approach relies on an absorption grating to create an array of micrometer-sized X-ray sources, posing numerous limitations, including technical challenges associated with grating fabrication for high-energy operations. We overcome these limitations by developing a TLI system with a microarray anode–structured target (MAAST) source. The MAAST features an array of precisely controlled microstructured metal inserts embedded in a diamond substrate. Using this TLI system, tomography of a Drum fish tooth with high resolution and tri-contrast (absorption, phase, and scattering) reveals useful complementary structural information that is inaccessible otherwise. The results highlight the exceptional capability of high-resolution multicontrast X-ray tomography empowered by the MAAST-based TLI method in biomedical applications.

47 OTHER INSTRUMENTATION↗

Ronchi shearing interferometry for wavefronts with circular symmetry

Ronchi testing of a focused electromagnetic wave has in the last few years been used extensively at X-ray free-electron laser (FEL) facilities to qualitatively evaluate the wavefront of the beam. It is a quick and straightforward test, is easy to interpret on the fly, and can be used to align phase plates that correct the focus of aberrated beams. In general, a single Ronchigram is not sufficient to gain complete quantitative knowledge of the wavefront. However the compound refractive lenses that are commonly used at X-ray FELs exhibit a strong circular symmetry in their aberration, and this can be exploited. Furthermore, a simple algorithm that uses a single recorded Ronchigram to recover the full wavefront of a nano-focused beam, assuming circular symmetry, is presented, and applied to experimental measurements at the Matter in Extreme Conditions instrument at the Linac Coherent Light Source.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prototype design and experimental tests of a zoom mirror system for the APS upgrade

Mirror-based zoom optics systems can offer variable focal spot sizes over a wide range, which is essential for coherent nanoprobe beamlines, such as the proposed Atomic beamline in the Advanced Photon Source (APS) upgrade project. The success of the zoom mirror system in the nano-focusing regime requires the development of high-precision deformable mirrors, in-situ surface profilers and wavefront sensors, and advanced feedback control system. A prototype 1-D zoom mirror system consists of two vertical focusing mirrors was designed, assembled, and tested at the APS 1-BM beamline. The system consists of a bender-based mirror with a capacitive-sensorarray-based real-time mirror profiler, a bimorph adaptive mirror, and a grating interferometer for the wavefront monitoring. In this work, we present the design and test results of the prototype system demonstrating its zoom focusing capability.

adaptive optics↗

Binary Amplitude Reflection Gratings for X-ray Shearing and Hartmann Wavefront Sensors

New, high-coherent-flux X-ray beamlines at synchrotron and free-electron laser light sources rely on wavefront sensors to achieve and maintain optimal alignment under dynamic operating conditions. This includes feedback to adaptive X-ray optics. We describe the design and modeling of a new class of binary-amplitude reflective gratings for shearing interferometry and Hartmann wavefront sensing. Compact arrays of deeply etched gratings illuminated at glancing incidence can withstand higher power densities than transmission membranes and can be designed to operate across a broad range of photon energies with a fixed grating-to-detector distance. Coherent wave-propagation is used to study the energy bandwidth of individual elements in an array and to set the design parameters. We observe that shearing operates well over a ±10% bandwidth, while Hartmann can be extended to ±30% or more, in our configuration. We apply this methodology to the design of a wavefront sensor for a soft X-ray beamline operating from 230 eV to 1400 eV and model shearing and Hartmann tests in the presence of varying wavefront aberration types and magnitudes.

47 OTHER INSTRUMENTATION↗

Grating-Based Imaging-Scattering with Portable Neutron Generator

Company: Adelphi Technology, Inc. Title: Grating-Based Imaging-Scattering with Portable Neutron Generator PI: Dr. Jay Theodore Cremer, Jr. Topic: 26a Statement of the problem or situation that is being addressed. Successful plant growth depends upon an efficient and robust root system. The plant root is part of a larger system of water and microbial flows in the soil system. While much effort has been exerted to develop an imaging system for water, microbes, and roots, the problem is challenging, and no widely accepted imaging method currently exists. The optical solutions use a highly modified soil system. X-ray imaging methods are insensitive to the soft tissues in the presence of sand. Thermal neutron imaging has been often tested, but found inadequate, due to limited access and low image resolution. This project will develop a new strategy for neutron imaging of plant/soil systems. The project will allow long duration experiments in greenhouse environments and increase the image information content to the micron scale. General statement of how this problem is being addressed. Portable, rugged thermal and fast neutron sources are being developed where portable means a two-soldier team can carry the source and power unit to survey rough terrain for explosives. In the past decade, microfabrication of X-ray and thermal/cold neutron optics has opened a new imaging strategy. The standard transmission image is now supplemented with simultaneous acquisition of a phase contrast image and an image revealing scattering features. In materials science, the interferometric neutron scattering image has been used to detect early crack formation in stressed additive manufacturing test samples. The detection requires sensitivity to scattering features at the 1-micron scale. By addition of our proposed grating-optic to Adelphi Technology’s radiographic/tomographic imaging system, which is based on portable thermal neutron source, the resulting thermal neutron scatter image of the plant/soil system, will reveal details at 1-micron. Commercial Applications and Other Benefits Neutron interferometry imaging has greater penetration through large metal components compared to industrial X-ray imaging. The low-cost, large area optics developed for greenhouse applications, combined with the robust, portable neutron generator, can then be marketed as a system for inspection of additive manufactured components. In the aerospace industry, all freshly printed components are validated with X-ray CT. Scheduled maintenance again requires X-ray CT as the ability to predict aerospace component lifetime does not yet exist. Large aerospace components are only partially observed with X-ray imaging. Key Words Neutron radiography/tomography, grating interferometry, thermal neutron generator imaging, plant root and soil imaging, rhizosphere imaging, deployable neutron imaging systems Summary for Members of Congress A rugged, portable source of thermal neutrons is adapted for neutron interferometry imaging with the addition of low-cost, 3D printed optics. The first application of our proposed deployable, compact thermal neutron generator imaging system, using a grating optic, is plant root/soil science in greenhouse settings and agricultural laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cone beam neutron interferometry: From modeling to applications

Phase-grating moiré interferometers (PGMIs) have emerged as promising candidates for the next generation of neutron interferometry, enabling the use of a polychromatic beam and manifesting interference patterns that can be directly imaged by existing neutron cameras. However, the modeling of the various PGMI configurations is limited to cumbersome numerical calculations and backward propagation models which often do not enable one to explore the setup parameters. Here we generalize the Fresnel scaling theorem to introduce a k -space model for PGMI setups illuminated by a cone beam, thus enabling an intuitive forward propagation model for a wide range of parameters and experimental setups. The interference manifested by a PGMI is shown to be a special case of the Talbot effect, and the optimal fringe visibility is shown to occur at the moiré location of the Talbot distances. We derive analytical expressions for the contrast and the propagating intensity profiles in various conditions and provide the first analysis of the PGMI dark-field imaging signal when considering sample characterization. The model's predictions are compared to experimental measurements and good agreement is found between them. Last, we propose and experimentally verify a method to recover contrast at typically inaccessible PGMI autocorrelation lengths. The presented work provides a toolbox for analyzing and understanding existing PGMI setups and their future applications, for example extensions to two-dimensional PGMIs and characterization of samples with nontrivial structures. Published by the American Physical Society 2024

Sarenac, D. (ORCID:0000000185753367)↗

Proof-of-concept Talbot–Lau x-ray interferometry with a high-intensity, high-repetition-rate, laser-driven K-alpha source

Talbot–Lau x-ray interferometry is a grating-based phase-contrast technique, which enables measurement of refractive index changes in matter with micrometric spatial resolution. The technique has been established using a variety of hard x-ray sources, including synchrotron, free-electron lasers, and x-ray tubes, and could be used in the optical range for low-density plasmas. The tremendous development of table-top high-power lasers makes the use of high-intensity, laser-driven K-alpha sources appealing for Talbot–Lau interferometer applications in both high-energy-density plasma experiments and biological imaging. To this end, we present the first, to the best of our knowledge, feasibility study of Talbot–Lau phase-contrast imaging using a high-repetition-rate laser of moderate energy (100 mJ at a repetition rate of 10 Hz) to irradiate a copper backlighter foil. The results from up to 900 laser pulses were integrated to form interferometric images. A constant fringe contrast of 20% is demonstrated over 100 accumulations, while the signal-to-noise ratio continued to increase with the number of shots. Phase retrieval is demonstrated without prior ex-situ phase stepping. Instead, correlation matrices are used to compensate for the displacement between reference acquisition and the probing of a PMMA target rod. The steps for improved measurements with more energetic laser systems are discussed. The final results are in good agreement with the theoretically predicted outcomes, demonstrating the applicability of this diagnostic to a range of laser facilities for use across several disciplines.

Bouffetier, V. (ORCID:0000000160791260)↗