Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas detector electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure

High-resolution submillimeter/terahertz spectroscopy is important for studying atmospheric and interstellar molecular gaseous species. It typically uses heterodyne receivers where an unknown (weak) signal is mixed with a strong signal from the local oscillator (LO) operating at a slightly different frequency. The non-linear mixer devices for this frequency range are unique and are not off-the-shelf commercial products. Three types of THz mixers are commonly used: Schottky diode, superconducting hot-electron bolometer (HEB), and superconductor-insulation-superconductor (SIS) junction. A HEB mixer based on the two-dimensional electron gas (2DEG) formed at the interface of two slightly dissimilar semiconductors was developed. This mixer can operate at temperatures between 100 and 300 K, and thus can be used with just passive radiative cooling available even on small spacecraft.

Karasik, Boris S.↗

Electronic Nose

Grace Industries, Inc.'s Electronic Nose is a vapor and gas detector, deriving from NASA's electronic circuitry, capable for sensing the presence of accelerants several days after a fire. The device is powered by rechargeable battery and no special training needed to operate. If an accelerant is present, device will emit a beeping sound and trigger a flashing light; the faster the beep rate, the more volatile the accelerant. Its sensitivity can also detect minute traces of accelerants. Unit saves investigators of fire causes time and expense by providing speedy detection of physical evidence for use in court. Device is also useful for detecting hazardous fumes, locating and detecting gas leaks in refineries and on oil drilling rigs.

Source record↗

N2O analysis in the atmosphere via electron capture-gas chromatography

The potential of commercially available pulse-modulated electron capture detector (ECD)-equipped gas chromatographs for direct measurement of ambient levels of N2O is assessed. Since the sensitivity of ECD to N2O is directly proportional to the detector operating temperature and detector standing current, it is necessary to use a 'hot' ECD (250-350 C). The method is shown to be very precise with a standard error not exceeding 1% for automated analysis of ambient air samples. The technology is available to permit highly accurate routine direct analysis of N2O in the troposphere and stratosphere. Both captured air samples or direct real-time measurement from research vessels or airborne platforms are possible.

Rasmussen, R. A.↗

Soft X-ray astronomy proportional counter electronics

The X-ray multiwire proportional counter is designed to measure cosmic X-ray fluxes at sounding rocket altitudes in the energy range of 0.1 to 10 keV. Four instruments will be launched in a Black Brant 4 rocket employing different combinations of detector windows and gas. The detector is constructed with two layers of twelve cells. A columnator is mounted on the face of one layer whose cells are wired together alternately to form two main detector sections. The electronics and gas regulation systems are mounted on the face of the second layer whose cells are wired together to form one anticoincidence detector section. Normally X-rays will have short ionization paths in only one of the main detector cells at a time and won't enter the anticoincidence detector cells. To distinguish between X-rays and charged particles, the instrument includes a coincidence discriminator, an anticoincidence discriminator, and a pulse rise time discriminator.

Gardner, W. R.↗

Monte-Carlo Estimation of the Inflight Performance of the GEMS Satellite X-Ray Polarimeter

We report a Monte-Carlo estimation of the in-orbit performance of a cosmic X-ray polarimeter designed to be installed on the focal plane of a small satellite. The simulation uses GEANT for the transport of photons and energetic particles and results from Magboltz for the transport of secondary electrons in the detector gas. We validated the simulation by comparing spectra and modulation curves with actual data taken with radioactive sources and an X-ray generator. We also estimated the in-orbit background induced by cosmic radiation in low Earth orbit.

Monte-Carlo simulation↗

Penning Ionization Electron Spectroscopy in Glow Discharge: A New Dimension for Gas Chromatography Detectors

Admixtures to helium of 100 ppm and 5 ppm of nitrogen, and 100 ppm and 10 ppm of carbon monoxide were identified and measured in the helium discharge afterglow using an electrical probe placed into the plasma. For nitrogen and carbon monoxide gases, the measured electron energy spectra display distinct characteristic peaks (fingerprints). Location of the peaks on the energy scale is determined by the ionization energies of the analyte molecules. Nitrogen and carbon monoxide fingerprints were also observed in a binary mixture of these gases in helium, and the relative concentration analytes has been predicted. The technically simple and durable method is considered a good candidate for a number of analytical applications, and in particular, in GC and for analytical flight instrumentation.

Sheverev, V. A.↗

Osmotic stress, endogenous abscisic acid and the control of leaf morphology in Hippuris vulgaris L

Previous reports indicate that heterophyllous aquatic plants can be induced to form aerial-type leaves on submerged shoots when they are grown in exogenous abscisic acid (ABA). This study reports on the relationship between osmotic stress (e.g. the situation encountered by a shoot tip when it grows above the water surface), endogenous ABA (as measured by gas chromatography-electron capture detector) and leaf morphology in the heterophyllous aquatic plant, Hippuris vulgaris. Free ABA could not be detected in submerged shoots of H. vulgaris but in aerial shoots ABA occurred at ca. 40 ng (g fr wt)-1. When submerged shoots were osmotically stressed ABA appeared at levels of 26 to 40 ng (g fr wt)-1. These and other data support two main conclusions: (1) Osmotically stressing a submerged shoot causes the appearance of detectable levels of ABA. (2) The rise of ABA in osmotically stressed submerged shoots in turn induces a change in leaf morphology from the submerged to the aerial form. This corroborates the hypothesis that, in the natural environment, ABA levels rise in response to the osmotic stress encountered when a submerged shoot grows up through the water/air interface and that the increased ABA leads to the production of aerial-type leaves.

NASA Program Space Biology↗

A measurement of the absolute flux of cosmic-ray electrons

A balloon-borne superconducting magnet spectrometer was used to measure the absolute flux of cosmic-ray electrons. The instrument consisted of a gas Cerenkov detector, a momentum spectrometer, and a lead-scintillator shower counter. In order to determine electron flux in the interstellar medium, observed fluxes for energy loss in the atmosphere and the payload were corrected, taking into account solar modulation effects and bremsstrahlung energy losses. Fluxes were measured at an average atmospheric depth of 5.8 g/sq cm, and the solar modulation was 300 MeV. A cosmic-ray electron flux of 367 E to the exp(3.15 + or -0.2) per sq m/sr s GeV was obtained in the energy range 4.5-63.5 GeV. The uncertainty of the absolute (electron-positron) flux was 10 percent. A summary of the electron data is given in a table.

Golden, R. L.↗

NASA Tech Briefs, July 2012

Topics covered include: Instrument Suite for Vertical Characterization of the Ionosphere-Thermosphere System; Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure; Pattern Recognition Algorithm for High-Sensitivity Odorant Detection in Unknown Environments; Determining Performance Acceptability of Electrochemical Oxygen Sensors; Versatile Controller for Infrared Lamp and Heater Arrays; High-Speed Scanning Interferometer Using CMOS Image Sensor and FPGA Based on Multifrequency Phase-Tracking Detection; Ultra-Low-Power MEMS Selective Gas Sensors; Compact Receiver Front Ends for Submillimeter-Wave Applications; Dynamically Reconfigurable Systolic Array Accelerator; Blocking Losses With a Photon Counter; Motion-Capture-Enabled Software for Gestural Control of 3D Mod; Orbit Software Suite; CoNNeCT Baseband Processor Module Boot Code SoftWare (BCSW); Trajectory Software With Upper Atmosphere Model; ALSSAT Version 6.0; Employing a Grinding Technology to Assess the Microbial Density for Encapsulated Organisms; Demonstration of Minimally Machined Honeycomb Silicon Carbide Mirrors; Polyimide Aerogel Thin Films; Nanoengineered Thermal Materials Based on Carbon Nanotube Array Composites; Composite Laminate With Coefficient of Thermal Expansion Matching D263 Glass; Robust Tensioned Kevlar Suspension Design; Focal Plane Alignment Utilizing Optical CMM; Purifying, Separating, and Concentrating Cells From a Sample Low in Biomass; Virtual Ultrasound Guidance for Inexperienced Operators; Beat-to-Beat Blood Pressure Monitor; Non-Contact Conductivity Measurement for Automated Sample Processing Systems; An MSK Radar Waveform; Telescope Alignment From Sparsely Sampled Wavefront Measurements Over Pupil Subapertures; Method to Remove Particulate Matter from Dusty Gases at Low Pressures; Terahertz Quantum Cascade Laser With Efficient Coupling and Beam Profile; Measurement Via Optical Near-Nulling and Subaperture Stitching; 885-nm Pumped Ceramic Nd:YAG Master Oscillator Power Amplifier Laser System; Airborne Hyperspectral Imaging System; Heat Shield Employing Cured Thermal Protection Material Blocks Bonded in a Large-Cell Honeycomb Matrix; and Asymmetric Supercapacitor for Long-Duration Power Storage.

Source record↗

Novel infrared detector based on a tunneling displacement transducer

The paper describes the design, fabrication, and characteristics of a novel infrared detector based on the principle of Golay's (1947) pneumatic infrared detector, which uses the expansion of a gas to detect infrared radiation. The present detector is constructed entirely from micromachined silicon and uses an electron tunneling displacement transducer for the detection of gas expansion. The sensitivity of the new detector is competitive with the best commercial pyroelectric sensors and can be readily improved by an order of magnitude through the use of an optimized transducer.

Kenny, T. W.↗

Performance of the Three-Dimensional Track Imager (3-DTI) for Gamma-Ray Telescopes

We have been developing a gas time projection chamber for the imaging of gamma-rays between 0.3 - 50 MeV, the Three-Dimensional Track Imager (3DTI). The detector is being designed for use on satellite experiments for the imaging of astrophysical gamma-ray sources. Electrons produced by pair production or Compton scattering ionize the gas and these ionization electrons are detected by the cross-strip micro-well detector at the bottom of the chamber. Discrete component of front end electronics and time digitization electronics have been developed. We will present results of prototype microwell detector and laboratory set-up in various gas mixtures.

Son, Seunghee↗

A Concept for a High-Energy Gamma-ray Polarimeter

We present a concept for an imaging gamma-ray polarimeter operating from approx. 50 MeV to approx. 1 GeV. Such an instrument would be valuable for the study of high-energy pulsars, active galactic nuclei, supernova remnants, and gamma-ray bursts. The concept makes use of pixelized gas micro-well detectors, under development at Goddard Space Flight Center, to record the electron-positron tracks from pair-production events in a large gas volume. Pixelized micro-well detectors have the potential to form large-volume 3-D track imagers with approx. 100 micron (rms) position resolution at moderate cost. The combination of high spatial resolution and a continuous low-density gas medium permits many thousands of measurements per radiation length, allowing the particle tracks to be imaged accurately before multiple scattering masks their original directions. The polarization of the incoming radiation may then be determined from the azimuthal distribution of the electron-positron pairs. We have performed Geant4 simulations of these processes to estimate the polarization sensitivity as a function of instrument parameters and event selection criteria.

Bloser, P. F.↗

The Gas Chromatograph Mass Spectrometer for the Huygens Probe

Titan is unique in the solar system, the only moon that has a dense atmosphere. The major constituents of the atmosphere, nitrogen and methane, are continuously broken apart by a combination of solar UV, impinging electrons from Saturn s magnetosphere, and a steady flux of cosmic rays. The resulting molecular fragments recombine and form a variety of new species, many of which were detected for the first time by Voyager1 . The ubiquitous, surface- hiding aerosol blanket manifests the existence of still more complex compounds. In addition to hydrocarbons and nitriles, the atmosphere is known to contain CO, CO2 and externally delivered H2O. The Gas Chromatograph Mass Spectrometer (GCMS) on the Huygens Probe will measure the chemical composition of the atmosphere of Titan from 170 Km altitude (approximately 1hPa) to the surface (approximately 1500hPa) and determine the isotope ratios of the major constituents. The GCMS will also analyze gas samples from the Aerosol Collector Pyrolyser (ACP) and may be able to obtain compositional information of several surface materials. The GCMS consists of a quadrupole mass spectrometer (QP) with a secondary electron multiplier ion detector, a three-column gas chromatograph (GC) and an elaborate gas sampling system. The gas sampling system will provide atmospheric samples to the QP for nearly continuous analysis during the Probe descent and batch samples at several altitudes for GC analysis. It also contains a chemical scrubber for noble gas analysis and an enrichment cell for trace constituent enhancement. In addition to the sampling of the atmosphere periodic gas samples, derived from the pyrolysis of aerosols, will be transferred from the ACP to the GCMS for direct QP and full GCMS analysis. The QP can analyze molecular masses from 2 to 141Dalton. The nominal detection threshold is at a mixing ratio of 10E-8. Data rate is 885 bits/sec. The mass of the instrument is 17.3 kg and the energy required for operation during the descent is 110 Watt-hours.

Niemann, H. B.↗

The Gas Chromatograph Mass Spectrometer for the Huygens Probe

Titan is unique in the solar system, the only moon that has a dense atmosphere. The major constituents of the atmosphere, nitrogen and methane, are continuously broken apart by a combination of solar UV, impinging electrons from Saturn's magnetosphere, and a steady flow of cosmic rays. The resulting molecular fragments recombine and form a variety of new species, many of which were detected for the first time by Voyager 1. The ubiquitous, surface-hiding aerosol blanket manifests the existence of still more complex compounds. In addition to hydrocarbons and nitriles, the atmosphere is known to contain CO, CO2 and externally delivered H2O. The Gas Chromatograph Mass Spectrometer (GCMS) on the Huygens Probe will measure the chemical composition of the atmosphere of Titan from 170 km altitude (approximately lhPa) to the surface (approximately 1500hPa) and determine the isotope ratios of the major constituents. The GCMS will also analyze gas samples from the Aerosol Collector Pyrolyser (ACP) and may be able to obtain compositional information of several surface materials. The GCMS consists of a quadrupole mass spectrometer (QP) with a secondary electron multiplier ion detector, a three-column gas chromatograph (GC) and an elaborate gas sampling system. The gas sampling system will provide atmospheric samples to the QP for nearly continuous analysis during the Probe descent and batch samples at several altitudes for GC analysis. It also contains a chemical scrubber for noble gas analysis and an enrichment cell for trace constituent enhancement. In addition to the sampling of the atmosphere periodic gas samples, derived from the pyrolysis of aerosols, will be transferred from the ACP to the GCMS for direct QP and full GCMS analysis. The QP can analyze molecular masses from 2 to 14lDalton. The nominal detection threshold is at a mixing ratio of 10E-8. Data rate is 885 bits/sec. The mass of the instrument is 17.3 kg and the energy required for operation during the descent is 110 Watt-hours.

Niemann, H. B.↗

Gas-chromatographic measurements of atmospheric CF2Cl2, CFCl3 and N2O in Antarctica

Stratospheric ozone is produced photochemically and destroyed by reactions with such minor constituents as O, NOx, HOx, and ClOx. Chlorofluoromethanes (CF2Cl2 and CFCl3) and dinitrogen oxide (NwO) are considered as major sources of the stratospheric ClOx and NOx, respectively. It is well known that CF2Cl2 and CFCl3 are released only by man's activities, and are being accumulated in the troposphere. In order to assess the influence of these compounds on the natural ozone balance these gases have been measured over Japan since 1978. Measurements of Antarctic air samples are also indispensable to understanding the global distributions of these gases, because most CF2Cl2 and CFCl3 have been released in the Northern Hemisphere. Antarctic air samples were obtained by the 23rd, 24th and 25th Japanese Antarctic Research Expeditions, and analyzed by a gas-chromatographic method using an electron capture detector. Three experimental results were obtained: (1) latitudinal distribution of these gases from Tokyo to Syowa Station (69.0 deg S, 39.6 deg E), (2) time trends at Syowa Station, and (3) vertical distributions over Syowa Station. Results are reported.

Hirota, H.↗

Applications of Gas Imaging Micro-Well Detectors to an Advanced Compton Telescope

We present a concept for an Advanced Compton Telescope (ACT) based on the use of pixelized gas micro-well detectors to form a three-dimensional electron track imager. A micro-well detector consists of an array of individual micro-patterned proportional counters opposite a planar drift electrode. When combined with thin film transistor array readouts, large gas volumes may be imaged with very good spatial and energy resolution at reasonable cost. The third dimension is determined by timing the drift of the ionization electrons. The primary advantage of this approach is the excellent tracking of the Compton recoil electron that is possible in a gas volume. Such good electron tracking allows us to reduce the point spread function of a single incident photon dramatically, greatly improving the imaging capability and sensitivity. The polarization sensitivity, which relies on events with large Compton scattering angles, is particularly enhanced. We describe a possible ACT implementation of this technique, in which the gas tracking volume is surrounded by a CsI calorimeter, and present our plans to build and test a small prototype over the next three years.

Bloser, P. F.↗