Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Versatile soil gas concentration and isotope monitoring: optimization and integration of novel soil gas probes with online trace gas detection

Abstract. Gas concentrations and isotopic signatures can unveil microbial metabolisms and their responses to environmental changes in soil. Currently, few methods measure in situ soil trace gases such as the products of nitrogen and carbon cycling or volatile organic compounds (VOCs) that constrain microbial biochemical processes like nitrification, methanogenesis, respiration, and microbial communication. Versatile trace gas sampling systems that integrate soil probes with sensitive trace gas analyzers could fill this gap with in situ soil gas measurements that resolve spatial (centimeters) and temporal (minutes) patterns. We developed a system that integrates new porous and hydrophobic sintered polytetrafluoroethylene (sPTFE) diffusive soil gas probes that non-disruptively collect soil gas samples with a transfer system to direct gas from multiple probes to one or more central gas analyzer(s) such as laser and mass spectrometers. Here, we demonstrate the feasibility and versatility of this automated multiprobe system for soil gas measurements of isotopic ratios of nitrous oxide (δ18O, δ15N, and the 15N site preference of N2O), methane, carbon dioxide (δ13C), and VOCs. First, we used an inert silica matrix to challenge probe measurements under controlled gas conditions. By changing and controlling system flow parameters, including the probe flow rate, we optimized recovery of representative soil gas samples while reducing sampling artifacts on subsurface concentrations. Second, we used this system to provide a real-time window into the impact of environmental manipulation of irrigation and soil redox conditions on in situ N2O and VOC concentrations. Moreover, to reveal the dynamics in the stable isotope ratios of N2O (i.e., 14N14N16O, 14N15N16O, 15N14N16O, and 14N14N18O), we developed a new high-precision laser spectrometer with a reduced sample volume demand. Our integrated system – a tunable infrared laser direct absorption spectrometry (TILDAS) in parallel with Vocus proton transfer reaction mass spectrometry (PTR-MS), in line with sPTFE soil gas probes – successfully quantified isotopic signatures for N2O, CO2, and VOCs in real time as responses to changes in the dry–wetting cycle and redox conditions. Broadening the collection of trace gases that can be monitored in the subsurface is critical for monitoring biogeochemical cycles, ecosystem health, and management practices at scales relevant to the soil system.

54 ENVIRONMENTAL SCIENCES↗

One-shot gas detection with transformer paired neural networks in Mako collected longwave infrared hyperspectral imagery

To date, careful data treatment workflows and statistical detectors are used to perform hyperspectral image (HSI) detection of any gas contained in a spectral library, which is often expanded with physics models to incorporate different spectral characteristics. In general, surrounding evidence or known gas-release parameters are used to provide confidence in or confirm detection capability, respectively. This makes quantifying detection performance difficult as it is nearly impossible to develop an absolute ground truth for gas target pixel presence in collected HSI. Consequently, developing and comparing new detection methods, especially machine learning (ML)-based methods, is susceptible to subjectivity in derived detection map quality. Here, in this work, we demonstrate the first use of transformer-based paired neural networks (PNNs) for one-shot gas target detection for multiple gases while providing quantitative classification and detection metrics for their use on labeled data. Terabytes of training data are generated from a database of long-wave infrared HSI obtained from historical Mako sensor campaigns over Los Angeles. By incorporating labels, singular signature representations, and a model development pipeline, we can tune and select PNNs to detect multiple gas targets that are not seen in training on a quantitative basis. We additionally assess our test set detections using interpretability techniques widely employed with ML-based predictors, but less common with detection methods relying on learned latent spaces.

Hyperspectral imaging↗

Trace-Level, Multi-Gas Detection for Food Quality Assessment Based on Decorated Silicon Transistor Arrays

Multiplexed gas detection at room temperature is critical for practical applications, such as for tracking the complex chemical environments associated with food decomposition and spoilage. Here, an integrated array of multiple silicon-based, chemical-sensitive field effect transistors (CSFETs) is presented to realize selective, sensitive, and simultaneous measurement of gases typically associated with food spoilage. CSFETs decorated with sensing materials based on ruthenium, silver, and silicon oxide are used to obtain stable room-temperature responses to ammonia (NH 3 ), hydrogen sulfide (H 2 S), and humidity, respectively. For example, one multi-CSFET sensor signal changes from its baseline by 13.34 in response to 1 ppm of NH 3 , 724.45 under 1 ppm H 2 S, and 23.46 under 80% relative humidity, with sensitive detection down to 10 ppb of NH 3 and H 2 S. To demonstrate this sensor for practical applications, the CSFET sensor array is combined with a custom-printed circuit board into a compact, fully integrated, and portable system to conduct real-time monitoring of gases generated by decomposing food. By using existing silicon-based manufacturing methodologies, this room-temperature gas sensing array can be fabricated reproducibly and at low cost, making it an attractive platform for ambient gas measurement needed in food safety applications.

36 MATERIALS SCIENCE↗

A Library of Proton-Transfer Reactions of H{sub 3}O{sup +} Ions Used for Trace Gas Detection

We have collected data on the proton-transfer reactions with H{sub 3}O{sup +} ions for trace gas detection into an online and publicly available library. The library allows users of proton-transfer-reaction mass spectrometry (PTR-MS) and selected-ion flow-tube mass spectrometry (SIFT-MS) to look up at which m/z a trace gas of interest is detected. Vice versa, the library also allows looking up what trace gas may have been responsible for a product ion detected in PTR-MS and SIFT-MS. Finally, the library may serve as a dataset for further research on calculating instrument sensitivity and product-ion fragmentation, improving identification and quantification of newly detectable compounds as advances in instrumentation continue. To demonstrate the utility of the library, we present a brief analysis of product-ion fragmentation. We show that oxygenated organic compounds exhibit trends in neutral loss according to their functionality, and that on average neutral losses decrease the carbon number and increase the extent of unsaturation of product ions. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Detecting gas leaks using unmanned aerial vehicles

Methods, systems and computer program products for detecting gas leaks using a drone are provided. Aspects include capturing a first set of data regarding a presence of a gas in the geographic area while flying along the initial flight path. Aspects also include creating secondary flight paths through regions in the geographic area in which the presence of the gas exceeds a threshold amount and capturing a second set of data regarding a concentration of the gas in the one or more regions while flying along the secondary flight paths. Aspects further include capturing wind data while flying along the initial and second flight paths and creating a three-dimensional gas plume model for gas leaks identified in the geographic area based on the first set of data, the second set of data and the wind data, wherein the three-dimensional gas plume model identifies a source of the gas leaks.

47 OTHER INSTRUMENTATION↗

Influence of Langasite Crystal Orientation on Hydrogen Gas Detection up to 400°C

Hydrogen gas sensors are of great importance due to the explosive nature and volatility of H 2 at concentrations above 4%. Also important is the capability of operation at high temperatures in harsh industrial environments, aerospace, automotive, and power generation applications. Surface Acoustic Wave (SAW) technology offers many desirable properties for sensor fabrication, such as the capability of wireless and battery free operation, mass-production, small size and weight. Piezoelectric substrates or thin films, such as langasite and aluminum nitrate, exist that allow SAW devices to operate at high temperatures. Langasite SAW-based devices have been previously demonstrated as temperature, strain and gas sensors. For high temperature SAW-based gas sensors, sensitive films capable to react selectively with the target species are normally used. This work presents the detection of hydrogen gas at high-temperature (up to 470 C) using SAW resonators on the commercially available LGS plane described by Euler angles {0°, 138.5°,Ψ}. The Pt-Al 2 O 3 composite thin film is used as both the electrode and sensitive layer. Devices fabricated along different crystal orientations on the same wafer revealed different sensitivities to H 2 , which were also measured as a function of temperature up to 470 C. These different sensitivities to H 2 open the possibility of using different orientations of this commercially available LGS crystal cut to fabricate sensors capable of operating as a network, and detecting different measurands at high-temperature, including hydrogen gas.

36 MATERIALS SCIENCE↗

Trace gas detection with 2-photon, 2-color, cavity ring-down spectroscopy

In one aspect, a method of detecting a trace gas is disclosed. The method includes containing the trace gas in an optical cavity. The method further includes injecting a first laser light from a first laser into the optical cavity causing the trace gas to transition from an energy state lower that a first excited energy state to the first excited energy state, and injecting a second laser light from a second laser into the optical cavity causing the trace gas to transition from the first excited energy state to a second excited energy state. The method includes measuring, by a detector, a first cavity ringdown intensity as a function of time after turning off the second laser with the first laser on, and a second cavity ringdown intensity as a function of time after turning off the second laser with the first laser off.

McCartt, Daniel↗

Acoustic sensing and autoencoder approach for abnormal gas detection in a spent nuclear fuel canister mock-up

Currently, spent nuclear fuel (SNF) from commercial nuclear power plants is stored in stainless-steel canisters for interim dry storage. To provide an inert environment, these canisters are backfilled with helium after vacuum drying. However, the helium environment may be contaminated during extended storage because of the material degradation. For example, the heavier fission gas xenon may be released from the fuel rods into the canister cavity should the fuel cladding be breached. Other gases such as air and water vapor may also be present as a result of leakage caused by chloride-induced stress corrosion cracking on the canister walls or by insufficient vacuum drying. Therefore, monitoring the gas composition can provide critical information about the health of SNF canisters. In this study, noninvasive testing was conducted on a 2/3-scaled SNF canister mock-up using acoustic sensing. Ultrasonic transducers were placed on the exterior surface of the canister to probe the gas composition. A dataset was collected by sealing the canister mock-up and introducing up to 1.53% argon or 1.29% air into the helium background gas. Three methods were used to detect changes in the gas composition: the time-of-flight (TOF) method, the differential method, and the autoencoder method. Results showed that the TOF method had sufficient resolution to detect abnormal gas concentrations of less than 1.0%. The differential method demonstrated a periodic in-phase and out-of-phase behavior between the benchmark (i.e., pure helium) and abnormal (i.e., with argon or air) state signals. The variational autoencoder (VAE) and the Wasserstein autoencoder (WAE) were trained on the benchmark data and were applied directly to the abnormal state data. It was found that both the unsupervised VAE and the WAE were able to distinguish the benchmark and abnormal states of the canister mock-up based on the reconstruction error.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

All-aerosol-jet-printed highly sensitive and selective polyaniline-based ammonia sensors: a route toward low-cost, low-power gas detection

In this work, we report the design and scalable fabrication of a low-cost and low-power polyaniline-based (PANI) ammonia (NH3) gas sensor on polyimide (PI) substrates using additive manufacturing techniques. The silver interdigitated electrode (IDE) arrays and conducting polymer films are printed onto PI using a direct-write technology of aerosol-jet printing. Morphological characteristics are examined by scanning electron microscopy and energy-dispersive X-ray analysis which reveal homogeneously printed PANI film on the IDE platform. The gas sensing performance is evaluated in the analytical early leak detection range of 5–1000 ppm NH3 in air as a function of both thermal (23 °C, 50 °C, 80 °C) and relative humidity (RH = 0%, 30%, 50%) exposures. The sensor exhibits sensitivity down to 5 ppm NH3 with a sub-ppm detection limit and good repeatability. We observe rapid NH3 detection at 0% RH with very extended times for equilibration and recovery. However, at both 30 and 50% RH, the room temperature response and recovery times are reduced to only about 1 min and 5 min, respectively. Experiments also reveal good sensitivity toward the analyte even at higher operating temperatures. Present results merit the practical application of aerosol-jet-printed, low-power sensors for industrial applications where low-level hazardous gas detection is essential.

36 MATERIALS SCIENCE↗

Impurity gas detection for SNF canisters using probabilistic deep learning and acoustic sensing *

Abstract Monitoring impurity gases in spent nuclear fuel (SNF) canisters is a novel structural health monitoring approach for SNF in dry storage. The SNF canisters are sealed containers that do not facilitate visual access to the inside. Acoustic sensing can be deployed by taking advantage of the pathways unobstructed by internal hardware. Although the ultrasonic time-of-flight measurement can provide valuable information, it is limited in its ability to discern the concentration of only one impurity gas. As such, deep learning algorithms, particularly convolutional neural networks (CNNs), offer a promising solution. In this study, CNN-based probabilistic deep learning models were implemented to detect and quantify multiple impurity gases in helium. An experimental platform was established to simulate canister conditions, and ultrasonic test data were collected. The presence of argon and air in helium at concentrations ranging from 0% to 1.2% at increments of 0.05% was considered. The multi-layer perceptron, decision tree, and logistic regression classifiers achieved high accuracies when distinguishing pure helium from helium with impurities. CNN with dropout layers and CNN using maximum likelihood estimation showed a similar performance, indicating their ability to capture uncertainties. The ensemble CNN model exhibited improved predictions and the ability to balance individual gas concentration by integrating 1D- and 2D-CNN models. These findings contribute probabilistic deep learning solutions for impurity gas detection and analysis within SNF canisters, thus ensuring safe storage and management of SNFs.

47 OTHER INSTRUMENTATION↗

Slow-Light Mid-IR Silicon Photonic Chips for NO 2 and CH 4 Gas Detection

A compact, chip-scale mid-infrared gas sensor is demonstrated, leveraging a two-dimensional photonic crystal waveguide (PCW) fabricated on a silicon-on-insulator (SOI) platform. The PCW comprises a hexagonal lattice with lattice constant a = 860 nm and hole radius r = 0.22a, incorporating a central line defect of reduced-radius holes (r s = 0.7r) to induce slow-light propagation near the photonic band edge with a group index of approximately 73, thereby enhancing light-matter interaction. The sensor operates at fundamental absorption wavelengths of 3.42 μm for nitrogen dioxide (NO 2 ) and 3.40 μm for methane (CH 4 ), utilizing the strongest molecular vibrational transitions for maximum sensitivity. Experimental validation was conducted using dynamically diluted gas mixtures generated by mass flow controllers, with signal acquisition performed by a liquid nitrogen-cooled InSb detector. For NO 2 , the sensor exhibited excellent linear response over 5–25 ppm (part per million) with coefficient of determination R 2 = 0.9934, achieving a detection limit of 210 ppb (part per billion)─representing the first reported silicon photonic-based NO 2 detection. For CH 4 , exposure to 25 ppm resulted in a 6.4% decrease in transmitted intensity, demonstrating multigas sensing capability. The CMOS-compatible fabrication process and compact 3 mm device footprint establish this SOI-PCW platform as a scalable, low-power solution for integrated mid-infrared gas sensing, with significant potential for environmental monitoring and industrial safety applications.

Crystals↗

In-situ localized growth of porous metal oxide films on microheater platform for low temperature gas detection

A solid-state, low power microheater sensor platform that is configurable with selected metal oxide films for particular gas sensing applications is described. The sensor platform is configured by selecting a chemiresistive or catalytic material that is suitable for detecting a desired gas and then forming a porous nanostructured film on the designated surfaces of the microheater platform. Also described are methods for creating a highly porous, nanostructured metal oxide film in a controlled location from a liquid precursor using a localized heat source. By fast annealing deposited liquid precursors with the microheater, a highly porous, nanocrystalline metal oxide film can be generated in-situ and locally on the sensor platform.

Maboudian, Roya↗

BOS Gas Detection Pipeline (Integrated System for Optical Hydrogen Detection Using Background Oriented Schlieren and Machine Learning) [SWR-26-007]

This software is the world's first integrated background oriented schlieren and machine learning-based leak detection system. The system provides real time visualization of gas leaks and machine learning interpenetration of leak severity. The software is supplemented by SWR-25-177, "gpu_piv (Graphics Processing Unit Accelerated Background Oriented Schlieren Algorithm", also developed by the National Laboratory of the Rockies. SEE DOECODE ID 182832.

Palin, Ian [National Laboratory of the Rockies (NL↗

Integrating Metal-Hydride and Gas-Detector for Tritium Gas Detection

Detection of trace amounts of environmental tritium is a challenging problem, driving the need for field-deployable systems that offer high sensitivity, selectivity, and minimal false positives. We present a technique for high-sensitivity, high-selectivity tritium measurement, which integrates metal-hydride and gas-detector concepts into a compact field-deployable tritium sensor. A hydrogen-storage metal embedded in a gas proportional counter selectively absorbs protium (1H)/tritium (3H), which are subsequently released into the counter volume with a reduced radiation background. Ionizations induced by 3H beta particles are then measured in proportional counting mode, achieving high detection efficiency. Preliminary studies conducted with palladium (Pd) thin films coated on stainless-steel substrates demonstrated 3H absorption and metal-tritide formation, followed by 3H desorption upon heating the metal-tritide. These processes were confirmed using activity concentrations measured by a commercial tritium monitor and pulse height spectra acquired from a custom-built detector.

Gas-proportional counter↗

Synergistic Integration of Chemo-Resistive and SERS Sensing for Label-Free Multiplex Gas Detection

Practical sensing applications such as real-time safety alerts and clinical diagnoses require sensor devices to differentiate between various target molecules with high sensitivity and selectivity, yet conventional devices such as oxide-based chemo-resistive sensors and metal-based surface-enhanced Raman spectroscopy (SERS) sensors usually do not satisfy such requirements. In this report a label-free, chemo-resistive/SERS multimodal sensor based on a systematically assembled 3D cross-point multifunctional nanoarchitecture (3D-CMA), which has unusually strong enhancements in both “chemo-resistive” and “SERS” sensing characteristics is introduced. 3D-CMA combines several sensing mechanisms and sensing elements via 3D integration of semiconducting SnO 2 nanowire frameworks and dual-functioning Au metallic nanoparticles. It is shown that the multimodal sensor can successfully estimate mixed-gas compositions selectively and quantitatively at the sub-100 ppm level, even for mixtures of gaseous aromatic compounds (nitrobenzene and toluene) with very similar molecular structures. This is enabled by combined chemo-resistive and SERS multimodal sensing providing complementary information.

36 MATERIALS SCIENCE↗