Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas chromatography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comprehensive two-dimensional gas chromatography under low-pressure conditions

The analysis of thermally labile and high-boiling point compounds by gas chromatography (GC) can be a challenge. One technique to overcome these challenges is low-pressure GC, which uses the vacuum produced from the mass spectrometer and wide-bore columns to elute compounds at significantly lower temperatures. While GC-MS is a powerful technique, comprehensive two-dimensional gas chromatography (GC × GC), allows for resolution of compounds that would typically coelute using GC. Here, in this study, a pesticide standard mixture (8270 MegaMix Standard) was analyzed using a conventional GC × GC-TOFMS configuration (0.25 mm inner diameter (i.d.) to a 0.18 mm i.d. column) and low-pressure GC × GC-TOFMS configuration (0.53 mm i.d. to a 0.53 mm i.d. column). Elution temperatures, sensitivity, and peak capacity were investigated for both configurations. Compounds eluted an average of 30 °C less on the low-pressure GC × GC-TOFMS configuration compared to the conventional GC × GC-TOFMS configuration. Moreover, the compounds were separated in ~13 min on the low-pressure GC × GC-TOFMS as opposed to 33 min for conventional GC × GC-TOFMS. However, due to the wide-bore columns and faster runtimes the low-pressure GC × GC-TOFMS had a lower, β corrected 2D peak capacity, n c,β,2D , of 1260 while the conventional GC × GC-TOFMS was 3588. Interestingly, both configurations yielded a similar peak capacity production of 93 peaks/min and 107 peaks/min for low-pressure and conventional GC × GC-TOFMS, respectively. A “real world” sample of diesel fuel was tested on the low-pressure and conventional GC × GC-TOFMS configurations and similar results were obtained compared to the pesticide standard mix except the peak capacity production of the low-pressure GC × GC-TOFMS configuration was higher than that of the conventional GC × GC-TOFMS method.

47 OTHER INSTRUMENTATION↗

Measuring Solvation Interactions of Deep Eutectic Solvents Formed by Metal Chlorides and an Imidazolium Salt by Inverse Gas Chromatography

Deep eutectic solvents (DESs) represent a class of solvents that offer a number of advantages including minimal toxicity, affordability, low vapor pressure, and simple, environmentally friendly preparation methods. They have found utility in areas, such as gas absorption, metal plating, and extractions. However, the relationship between their solvation properties and chemical composition remains poorly understood. In this study, a broad range of Type I DESs composed of metal chlorides and an imidazolium salt were prepared, employed as gas chromatographic stationary phases, and characterized using the Abraham solvation parameter model by inverse gas chromatography. The Abraham solvation parameter model allows for the study of DES solvation properties and the effects of varying structural components on system constants using a linear-free energy relationship. The DESs were investigated by systematically varying their composition, including the type of metal chloride and the molar ratio between the metal chloride and the imidazolium salt. The results show that hydrogen bond acidity, hydrogen bond basicity, and dipolarity/polarizability interactions are strongly influenced by the type of metal chloride within the DES and the ratio of metal chloride to imidazolium salt in the eutectic mixture. Furthermore, a column pretreatment procedure is presented that enables the effective coating of highly polar DESs onto open tubular capillary gas chromatography columns.

deep eutectic solvent↗

Development of a Gas Chromatography with High-Resolution Time-of-Flight Mass Spectrometry Methodology for BDNPA/F

Analysis of thermally labile compounds such as bis(2,2-dinitropropyl) acetal/formal (BDNPA/F), an energetic plasticizer, is usually performed via liquid chromatography (LC) as opposed to gas chromatography (GC) due to thermal decomposition in the inlet or the analytical column. While LC is a powerful technique, the analysis of volatile and semivolatile compounds is best suited to GC. Herein, a method was developed for a gas chromatograph coupled to high-resolution mass spectrometer (GC-HRMS), utilizing a programmable temperature vaporizer (PTV) inlet. A subset of the native compounds and several produced by the thermal decomposition of BDNPA/F in the inlet were evaluated by using multiple PTV inlet parameters to determine the optimal ramp rate and final temperature of the inlet (60 °C/min from 60 to 325 °C). The optimized GC-HRMS method nearly reduced all thermal decomposition, allowing for an excellent separation to be obtained. Furthermore, multiple ionization methods, including electron impact (EI), negative chemical ionization (NCI), and positive chemical ionization (PCI), were used to explore the many chemical differences between the BDNPA/F samples. A preliminary investigation of the benefits of using GC-HRMS to evaluate the chemical differences between unaged and aged BDNPA/F samples for unique insight was evaluated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen Analysis by Gas Chromatography–Mass Spectrometry

The detection of hydrogen in complex gas mixtures is essential for many applications. Conventional approaches such as gas chromatography (GC) with thermal conductivity detection (TCD) and residual gas analyzers (RGAs) face significant limitations: TCD exhibits poor response when helium is used as a carrier gas, whereas RGAs lack chromatographic separation, preventing reliable quantification of hydrogen because of interference from other species. Traditional GC methods rely on dual-column configurations with packed or molecular-sieve porous layer open tubular (PLOT) columns to separate hydrogen from O2, N2, CO, CO2, CH4, and other hydrocarbons, increasing system complexity and limiting compatibility with mass spectrometry (MS) detection. In this work, we developed and validated a robust GC–MS method capable of directly detecting and quantifying hydrogen using electron ionization (EI) without dopants, reagent gases, or ion–molecule reaction schemes. By integrating a modified EI source and a cryogenically cooled single capillary column configuration, we achieved baseline separation of hydrogen from all major permanent gases and hydrocarbons in a refinery gas mixture using helium as the carrier gas. The method demonstrated excellent linearity, high sensitivity, and exceptional reproducibility. Adjustable sample-loop volumes and split ratios enabled optimization of peak shape and signal-to-noise performance for trace-level and percent-level hydrogen concentrations. Beyond hydrogen quantitation, the method provides simultaneous compositional profiling of other gases in a mixture in a single run, making it valuable for a wide range of tasks.

Lobodin, Vlad [ORNL]↗

Physicochemical Gas–Solid Sorption Properties of Geologic Materials Using Inverse Gas Chromatography

The goal of this study was to determine the physicochemical properties of a variety of geologic materials using inverse gas chromatography (IGC) by varying probe gas selection, temperature, carrier gas flow rate, and humidity. This is accomplished by measuring the level of interaction between the materials of interest and known probe gases. Identifying a material’s physicochemical characteristics can help provide a better understanding of the transport of gaseous compounds in different geologic materials or between different geological layers under various conditions. Our research in this study focused on measuring the enthalpy (heat) of adsorption, Henry’s constant, and diffusion coefficients of a suite of geologic materials, including two soil types (sandy clay-loam and loam), quartz sand, salt, and bentonite clay, with various particle sizes. The reproducibility of IGC measurements for geologic materials, which are inherently heterogeneous, was also assessed in comparison to the reproducibility for more homogeneous synthetic materials. This involved determining the variability of physicochemical measurements obtained from different IGC approaches, instruments, and researchers. For the investigated IGC-determined parameters, the need for standardization became apparent, including the need for application-relevant reference materials. The inherent physical and chemical heterogeneities of soil and many geologic materials can make the prediction of sorption properties difficult. Characterizing the properties of individual organic and inorganic components can help elucidate the primary factors influencing sorption interactions in more complex mixtures. This research examined the capabilities and potential challenges of characterizing the gas sorption properties of geologic materials using IGC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crosslinked polymeric ionic liquid stationary phases incorporating a combination of silver(I) and copper(II) ions for olefin separations by gas chromatography

The development of efficient and selective olefin separation technologies is a critical challenge within the chemical industry given the high energy demands of conventional cryogenic distillation methods. To address this, the study explores the effectiveness of polymeric ionic liquid (PIL) stationary phases in gas chromatography (GC) that incorporate both silver(I) ([Ag + ]) and copper(II) ([Cu 2+ ]) ions for enhanced olefin separation via π-complexation interactions. Further, the effects of both non-crosslinked and crosslinked PIL stationary phases containing varying ratios of [Ag⁺] and [Cu²⁺] ions were systematically investigated to evaluate their impact on the separation of olefins from paraffins and structurally similar olefins. Retention measurements using a broad range of olefinic probes revealed that [Ag⁺] ions provided stronger and more consistent π-complexation in PIL-based stationary phases, while [Cu²⁺] ions preferentially enhance olefin retention in crosslinked systems. Furthermore, thermal stability studies showed that [Ag + ]-containing PIL stationary phases maintain stable olefin separation efficiency over prolonged exposure under elevated temperatures, while crosslinked PIL stationary phases containing [Cu 2+ ] ions exhibited stronger retention due to increased surface adsorption. These findings provide insight into the tunability of metal–olefin interactions using PIL-based stationary phases and suggest design strategies for achieving thermally stable and highly selective chromatographic separations of unsaturated hydrocarbons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding Biomass and Polymer Feedstock Variability Through Analytical Pyrolysis and Two Dimensional Gas Chromatography and Mass Spectrometry

Moving toward a circular carbon economy requires enabling reuse of carbon-based macromolecules like those in biomass and polymers. Meeting this goal requires increased upcycling of waste products into higher value products. For biomass waste such as corn stover, pine needles, or bark, one approach is using pyrolysis to convert these feedstocks into bio-oil that can be used for liquid fuel or transformed into other hydrocarbon based products, like bio-polymers. Waste plastics can be upcycled or recycled into new products, or alternatively converted into bio-oil by pyrolysis. Macromolecules from biomass and polymers are challenging to convert into liquid fuel or chemical feedstocks, due to large and sometimes heterogeneous networks of polymeric bonds. We work with the Idaho National Laboratory’s Biomass Feedstock National User Facility and Department of Energy’s Feedstock Conversion Interface Consortium to develop a molecular understanding of biomass variability that occurs naturally and as a result of storage or preprocessing techniques applied to feedstocks, to understand chemical reactions occurring during pyrolysis and other biomass or polymer conversion techniques. Using two dimensional gas chromatography mass spectrometry coupled to analytical pyrolysis provides insight into the molecular changes that occur during the pyrolysis event, and these insights can extend to bench or pilot scale pyrolysis conversions. Understanding pyrolysis of biomass and polymers at a molecular level contributes to development of new tools to predict and manipulate the optimum conditions and identify the best storage, preprocessing, and conversion techniques to maximize output of specific high-value chemical species in the conversion to fuels, or to characterize feedstocks for blending before pyrolysis. Identification and understanding of the molecular level changes resulting from novel preprocessing techniques that can be used to control and manipulate the chemical output of bench or pilot scale pyrolysis is another focus of investigation, including the use of gamma irradiation, acid, or enzyme pre-treatments. We also focus on the impacts of storage conditions and techniques, which can affect moisture levels, degradation, and impacts from naturally occurring microbes in the environment.

09 BIOMASS FUELS↗

Deep eutectic solvents as green and sustainable diluents in headspace gas chromatography for the determination of trace level genotoxic impurities in pharmaceuticals

Genotoxic impurities (GTIs) are potential carcinogens that need to be controlled down to ppm or lower concentration levels in pharmaceuticals under strict regulations. The static headspace gas chromatography (HS-GC) coupled with electron capture detection (ECD) is an effective approach to monitor halogenated and nitroaromatic genotoxins. Deep eutectic solvents (DESs) possess tunable physico-chemical properties and low vapor pressure for HS-GC methods. In this study, zwitterionic and non-ionic DESs have been used for the first time to develop and validate a sensitive analytical method for the analysis of 24 genotoxins at sub-ppm concentrations. Compared to non-ionic diluents, zwitterionic DESs produced exceptional analytical performance and the betaine: 7 (1,4- butane diol) DES outperformed the betaine: 5 (1,4-butane diol) DES. Limits of detection (LOD) down to the 5-ppb concentration level were achieved in DESs. Wide linear ranges spanning over 5 orders of magnitude (0.005–100 µg g –1 ) were obtained for most analytes with exceptional sensitivities and high precision. The method accuracy and precision were validated using 3 commercially available drug substances and excellent recoveries were obtained. Finally, this study broadens the applicability of HS-GC in the determination of less volatile GTIs by establishing DESs as viable diluent substitutes for organic solvents in routine pharmaceutical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Auto-deconvolution and molecular networking of gas chromatography–mass spectrometry data

We engineered a machine learning approach, MSHub, to enable auto-deconvolution of gas chromatography–mass spectrometry (GC–MS) data. We then designed workflows to enable the community to store, process, share, annotate, compare and perform molecular networking of GC–MS data within the Global Natural Product Social (GNPS) Molecular Networking analysis platform. MSHub/GNPS performs auto-deconvolution of compound fragmentation patterns via unsupervised non-negative matrix factorization and quantifies the reproducibility of fragmentation patterns across samples.

47 OTHER INSTRUMENTATION↗

Quantifying lithium loss in amorphous silicon thin-film anodes via titration-gas chromatography

Silicon with a high theoretical capacity (3,579 mAh/g) is a promising anode candidate for lithium-ion batteries. However, commercialization is still impeded by low Coulombic efficiency, caused by solid electrolyte interphase (SEI) formation and trapped lithium (Li)-silicon (Si) alloy during repeated volume change. Quantifying capacity losses from each factor is crucial to formulate rational design strategies for further improvement. In this work, titration-gas chromatography and cryogenic transmission electron microscopy are applied to characterize the evolution of trapped Li-Si alloy and SEI growth in a silicon thin-film anode. It is found that continuous growth of the SEI is the dominant factor for lithium inventory loss during cycling, with only a marginal increase in trapped Li-Si alloy. This study offers a quantitative approach to differentiate Li in the SEI from trapped Li in Li-Si alloy through a silicon thin-film anode, providing unique insights into identifying critical bottlenecks for developing Si anodes.

25 ENERGY STORAGE↗

gcxgclab: Two Dimensional Gas Chromatography Preprocessing and Analysis

The goal of gcxgclab is to provide a comprehensive program for preprocessing and analysis of two dimensional gas chromatography data. It is equipped with functions for baseline correction, smoothing, peak identification, peak alignment, identification of EICs, Mass Spectra, targeted analysis, compound identification with NIST and non-targeted analysis, plus plotting and data visualization.

GAMBLE, STEPHANIE↗

Trocylation of 3-quinuclidinol, a key marker for the chemical warfare agent 3-quinuclidinyl benzilate, for its enhanced detection at low levels in complex soil matrices by electron ionization gas chromatography–mass spectrometry

Detection of 3-quinuclidinol (3Q), a marker for the chemical warfare agent 3-quinuclidinyl benzilate, is very difficult by gas chromatography–mass spectrometry (GC/MS), providing low, broad signals even when analyzed in isolated form. Therefore, a method that can convert 3Q into a substrate with enhanced detectability by GC/MS would be an important tool for its analysis. 2,2,2-Trichloroethoxycarbonyl chloride (TrocCl) was used in the derivatization of 3Q in three different soils of varying composition and total organic content (Virginia type A soil, Nebraska EPA standard soil and Ottawa sand) when present at a 10 μg g -1 concentration in each. A direct derivatization protocol and one involving the pre-extraction of the analyte were evaluated for their individual efficiencies and subsequent analysis using electron ionization GC/MS. The practical derivatization of 3Q, when present at low levels (10 μg g -1 ) in three different soil matrices, was found to be rapid (1 h) and to take place smoothly at ambient temperature (and as low as 4°C). The method detection limit was determined to be 30 ng mL -1 for the Virginia type A soil, 49 ng mL -1 for the Nebraska EPA standard soil and 72 ng mL -1 for the Ottawa sand sample. An expedient and practical derivatization method for 3Q, a chemical warfare degradation product difficult to detect by GC/MS, has been realized using trichloroethyl chloroformate. The reaction provides 3Q-Troc, a derivative with better detectability than 3Q by electron ionization GC/MS such as peak sharpness and a unique mass spectrum for its unambiguous identification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trimethyloxonium-mediated methylation strategies for the rapid and simultaneous analysis of chlorinated phenols in various soils by electron impact gas chromatography–mass spectrometry

Abstract The efficient methylation of a panel of five industrial and environmentally-relevant chlorophenols (CPs) employing trimethyloxonium tetrafluoroborate (TMO) for their qualitative detection and identification by electron impact gas chromatography–mass spectrometry (EI-GC–MS) is presented. The protocol’s execution is simple and smoothly converts the phenols into their O-methylated counterparts conveniently at ambient temperature. The efficiency of two versions of the protocol was successfully tested in their ability to simultaneously derivatize five CPs (2-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, pentachlorophenol and triclosan) in six distinct, separate soil matrices (Nebraska EPA standard soil, Virginia Type A soil, Ottawa sand, Baker sand, Silt and Georgia EPA standard soil) when present at low levels (~ 10 μgg −1 ). The first version involves the direct derivatization of the spiked soils with the methylating salt while the second one involves an initial soil extraction step of the CPs followed by methylation. The MDL values for each methylated CP were determined and lower values were found (4.1–13.2 ng . mL −1 ) for both sand matrices (Ottawa and Baker) as well as for the Georgia EPA standard soil, while larger values (8.2–21.8 ng . mL −1 ) were found for the Virginia Type soil, Nebraska EPA standard soil and Silt. The presented protocol offers a safer and more practical alternative to the universally employed diazomethane method and can be readily applicable to matrices other than soils. Furthermore, the protocols described herein may find applicability to the methylation of other analytes bearing acidic protons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing Olefin Selectivity and Stability of Silver Salts in Ionic Liquids Using Inverse Gas Chromatography

Separation systems utilizing silver(I) ion-olefin complexation have limitations since silver(I) ions can be poisoned or reduced to metallic silver. Ionic liquids (ILs) are used as solvents for silver(I) ions to facilitate separations since their physico-chemical properties can be easily tuned. To develop separation systems with sustainable olefin selectivity, factors that affect silver(I) ion stability need to be understood. In this study, a total of 13 silver salt/IL mixtures were examined by inverse gas chromatography to identify the effects of silver salt anion and IL cation/anion combination on silver(I) ion stability. The effects of temperature and three different exposure gases on silver(I) ion stability were systematically studied. Exposing silver salt/IL mixtures to hydrogen at high temperatures had a greater effect on decreasing silver(I) ion-olefin complexation. Silver(I) ions from the silver bis[(trifluoromethyl)sulfonyl]imide ([NTf 2 – ]) salt were more stable in [NTf 2 – ]-containing ILs than in [BF 4 – ]-containing ILs. Optimum mixtures exhibited high olefin selectivity and were stable beyond 90 h when exposed to hydrogen gas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mapping glyceride species in biodiesel by high-temperature gas chromatography combined with chemical ionization mass spectrometry.

Accurate and comprehensive identification of residual glycerides in biodiesel is an important part of the fuel characterization, due to the impact of glycerides on the fuel physicochemical properties. However, analysis of bound glycerol in biodiesel samples faces challenges due to lack of readily available standards of structurally complex glyceride species in non-traditional biodiesel feedstocks, and a risk of misannotation in the presence of impurities in gas chromatographic separations. Here we evaluate methane and isobutane chemical ionization – single quadrupole mass spectrometry combined with high temperature gas chromatography separations for mapping monoacylglycerols, diacylglycerols and triacylglycerols in biodiesel. Unlike the electron impact ionization which produces mostly in-source fragments, isobutane chemical ionization spectra of tetramethylsilyl (TMS) derivatized monoacylglycerols and diacylglycerols are dominated by molecular ions and M-SiO(CH3)3+ ions, which provide important diagnostic information. We demonstrate the utility of isobutane chemical ionization in identifying structurally complex glycerolipid standards as well as species in biodiesel samples from different plant and animal feedstocks.

biodiesel, chemcial ionization mass spectrometry↗