Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “galvanic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The timing of galvanic vestibular stimulation affects responses to platform translation

We compared the effects of galvanic vestibular stimulation applied at 0, 0.5, 1.5 and 2.5 s prior to a backward platform translation on postural responses. The effect of the galvanic stimulation was largest on the final equilibrium position of the center of pressure (CoP). The largest effects occurred for the 0.5 and 0-s pre-period, when the dynamic CoP pressure changes in response to both the galvanic stimulus and the platform translation coincided. The shift in the final equilibrium position was also larger than the sum of the shifts for the galvanic stimulus and the platform translation alone for the 0.5 and 0-s pre-periods. The initial rate of change of the CoP response to the platform translation was not significantly affected in any condition. Changes in the peak CoP position could be accounted for by local interaction of CoP velocity changes induced by the galvanic and translation responses alone, but the changes in final equilibrium position could only be accounted for by a change in global body orientation. These findings suggest that the contribution of vestibulospinal information is greatest during the dynamic phase of the postural response, and that the vestibular system contributes most to the later components of the postural response, particularly to the final equilibrium position. These findings suggest that a nonlinear interaction between the vestibular signal induced by the galvanic current and the sensory stimuli produced by the platform translation occurs when the two stimuli are presented within 1 s, during the dynamic phase of the postural response to the galvanic stimulus. When presented at greater separations in time, the stimuli appear to be treated as independent events, such that no interaction occurs. Copyright 1999 Elsevier Science B.V.

Non-NASA Center↗

Galvanic corrosion of AZ31B joined to dual-phase steel with and without Zn layer by ultrasonic and friction stir welding

Galvanic corrosion of AZ31B joined with bare or Zn-coated DP590 steel by ultrasonic spot welding or linear friction stir welding was quantitatively studied by pre-defining anode and cathode in the lap joint samples. Corrosion volume and depth from Mg anode surfaces exposed to 0.1 M sodium chloride solution was analyzed as functions of cathode surface type and welding method. Characterization of as-welded joints was performed to identify any microstructural feature of the bonding zone that could impact galvanic corrosion behavior. COMSOL modeling with modified user subroutine was conducted to simulate the progression of Mg corrosion in the same joint and electrode configurations used for the corrosion experiments. The experimental results indicated that Zn-coated cathode surface can reduce Mg galvanic corrosion significantly as galvanic polarization and cathodic current on Zn-coated surface remained relatively low for Mg in the weld joints. COMSOL modeling described the growth of Mg galvanic corrosion in a reasonable manner but showed limitation by underestimating the corrosion volume as it did not capture self-corrosion.

36 MATERIALS SCIENCE↗

Mitigation of Galvanic Corrosion in Bolted Joint of AZ31B and Carbon Fiber-Reinforced Composite Using Polymer Insulation

The use of polymer insulation to mitigate galvanic corrosion was examined for bolted joints of AZ31B Mg alloy and carbon fiber-reinforced composite. To assess the corrosion behaviors of bolted joints with and without polymer insulation, solution immersion and salt spray exposure (ASTM B117) tests were conducted, and the corrosion depths and volumes were determined for the joint specimens after the tests. The polymer-insulated bolted joints exhibited much lower corrosion depths and volumes, highlighting the effective mitigation of galvanic corrosion. The reductions of joint strength in the post-corrosion joint specimens were relatively small (up to ~10%) in the polymer-insulated group but greater (up to 90%) in the group with no insulation. Cross-sectional characterization of post-corrosion joints with polymer insulation revealed local pits developed on AZ31B under galvanic influence, indicating that limited galvanic attack (that did not decrease the joining integrity significantly) could still occur during a long salt spray exposure (~1264 h) owing to the permeation of an aqueous corrosive medium.

36 MATERIALS SCIENCE↗

Galvanic coupling between D6AC steel, 6061-T6 aluminum, Inconel 718 and graphite-epoxy composite material: Corrosion occurrence and prevention

The effects of galvanic coupling between D6AC steel, 6061-T6 aluminum, Inconel 718, and graphite-epoxy composite material (G/E) in 3.5% NaCl were studied. Measurements of corrosion potentials, galvanic currents and corrosion rates of the bare metals using weight-loss methods served to establish the need for corrosion protection in cases where D6AC steel and 6061-T6 aluminum are galvanically coupled to G/E in salt water while Inconel 718 was shown to be compatible with G/E. Six tests were made to study corrosion protective methods for eliminating galvanic corrosion in the cases of D6AC steel and 6061-T6 aluminum coupled to G/E. These results indicate that, when the G/E is completely coated with paint or a paint/polyurethane resin combination, satisfactory protection of the D6AC steel is achieved with either a coat of zinc-rich primer or a primer/topcoat combination. Likewise, satisfactory corrosion protection of the aluminum is achieved by coating it with an epoxy coating system.

Danford, M. D.↗

Galvanic Corrosion of Carbon Steel and Stainless Steel Couples: Effects of γ-Radiation and Solution Environment - 20348

Galvanic corrosion between carbon steel (CS) and stainless steel (SS) in different aqueous environments was investigated using a combination of electrochemical measurements and surface characterizations. In a basic environment (pH 10.6), the galvanic effect is negligible due to the high corrosion resistance of both alloys. In an acidic to near neutral environment (pH 6.0), the galvanic effect is more significant. Coupling to SS, increasing temperature, and irradiation at this pH have a synergistic effect on the corrosion progression of CS, and their effects vary with time. Initially, the oxidation rate of CS increases after galvanic coupling to SS. Increasing temperature or applying γ-radiation accelerates this oxidation process. However, at a longer time when the saturation limits of metal cations are reached, they also lead to the formation and growth of oxides on CS at a much faster rate, resulting in the suppression of the subsequent Fe dissolution. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Galvanic Transformation Dynamics in Heterostructured Nanoparticles

Corrosion is a significant problem for the stability of structural metals and potentially for functional nanomaterials in operating environments. When two metals with different electrochemical potentials form a junction, galvanic corrosion occurs, resulting in the sacrificial dissolution of the metal with a higher oxidation potential (lower electrode potential). In this report it is shown that bimetallic hetero-nanostructures composed of phase-segregated metals undergo galvanic corrosion in aqueous environments. Such selective etching of the sacrificial metal in heterojunction particles leads to the formation of unusual and kinetically stabilized half-spheroid particles. By using a fluid cell and in situ scanning transmission electron microscopy, a two-stage corrosion process can be observed where the Cu experiences a fractal breakdown before the Ag corrodes due to the lack of a protective oxide layer. However, when treated with a mild Ar plasma, the stability of these structures against corrosion is enhanced due to the conversion of the amorphous native oxide to a denser, thin layer of CuO on the Cu surface. Taken together, this work highlights the importance of considering the effects of galvanic corrosion on the stability of multicomponent nanoparticles, and it shows how mass transport in a nanoscale system is influenced by redox processes.

36 MATERIALS SCIENCE↗

Complementing Nanoscale Galvanic Exchange with Redox Manipulation toward Architectural Control of Multimetallic Hollow Nanostructures

Galvanic exchange occurring within the confinement by nanoparticulate templates provides a unique pathway to controllably transform solid metallic nanoparticles into architecturally more sophisticated multimetallic hollow nanostructures under facile reaction conditions. As such, in this Minireview, we elaborately discuss how the nanoparticle-templated galvanic exchange can be deliberately coupled with redox manipulation to synthesize a large library of complex multimetallic hollow nanostructures exhibiting precisely tailored architectures and compositions, with a particular emphasis on important mechanistic insights concerning the dynamic interplay among multiple structure-remodeling processes that synergistically dictate the versatile nanoparticle transforming behaviors during kinetically and regioselectively modulated galvanic exchange reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of Galvanic Corrosion in Molten Salts

Molten salts are an excellent choice for thermal energy storage materials in concentrated solar power (CSP) plants, yet some salts can cause corrosion of containment alloys that damage plants and increase maintenance costs. Corrosion rates have been characterized for many salt/alloy combinations. However, corrosion rates at junctions of dissimilar alloys in molten salts are relatively poorly characterized. At such junctions, which are common in CSP plants, it is possible that galvanic interactions or other mechanisms could increase corrosion above the industry standard of 20 µm/year. Preliminary reports measured corrosion at dissimilar alloy junctions with a variety of methods, but the results are not uniform. Additionally, some reports have shown that corrosion rates are higher for single alloys than for the same alloys when paired in a galvanic couple, suggesting complex corrosion mechanisms. Here we present a discussion on measuring galvanic corrosion in molten salts that accounts for differences in results between methods and explores the possibility of other mechanisms of corrosion in the system.

Massimi, Scott Edward (ORCID:0000000244008093)↗

Torsional Eye Movements Evoked by Unilateral Labyrinthine Galvanic Polarizations in the Squirrel Monkey

Electrical stimulation of vestibular-nerve afferents innervating the semicircular canals has been used to identify the extraocular muscles receiving activation or inhibition by individual ampullary nerves. This technique was originally developed by Szentagothai (1950) and led to the description of three neuron reflex arcs that connect each semicircular canal through an interneuron traversing in the region of the medial longitudinal fasciculus to one ipsilateral and one contralateral eye muscle. Selective ampullary nerve stimulation was subsequently used by Cohen and colleagues (Cohen and Suzuki, 1963; Cohen et al., 1964; Suzuki et al., 1964; Cohen et al., 1966) to study movements of the eyes and activation of individual extraocular muscles in response to stimulation of combinations of ampullary nerves. This work led to a description of the now familiar relationships between activation of a semicircular canal ampullary nerves and the anticipated movement in each eye. Disconjugacy of eye movements induced by individual vertical canal stimulation and dependence of the pulling direction of vertical recti and oblique muscles on eye position were also defined in these experiments. Subsequent studies have defined the mechanisms by which externally applied galvanic currents result in a change in vestibular-nerve afferent discharge. The currents appear to act at the spike trigger site. Perilymphatic cathodal currents depolarize the trigger site and lead to excitation whereas anodal currents hyperpolarize and result in inhibition. Afferents innervating all five vestibular endorgans appear to be affected equally by the currents (Goldberg et al., 1984). Irregularly discharging afferents are about 5-10 times more sensitive than regularly discharging ones because of the steeper slope of the former's faster postspike recovery of excitability in encoder sensitivity (Smith and Goldberg, 1986). Response adaptation similar to that noted during acceleration steps is apparent for longer periods of current administration. This adaptation is manifested as a perstimulus return toward resting discharge and poststimulus after-response in the opposite direction (Goldberg et al., 1984; Minor and Goldberg, l991). Cathodal currents (with respect to the perilymphatic space of the vestibule) are excitatory whereas anodal currents are inhibitory. Horizontal eye movements evoked by unilateral galvanic polarizations administered through chronically implanted labyrinthine stimulating electrodes have been studied in alert squirrel monkeys (Minor and Goldberg, 1991). We sought to extend this analysis by recording three-dimensional eye movements during galvanic stimulation. As predicted based upon roughly equal stimulation of ampullary nerves innervating the vertical canals, a substantial torsional component to the nystagmus is noted. The trajectory of torsional slow phases and nystagmus profile after the polarization provide insight into the central mechanisms that influence these responses.

Minor, Lloyd B.↗

Saccule contribution to immediate early gene induction in the gerbil brainstem with posterior canal galvanic or hypergravity stimulation

Immunolabeling patterns of the immediate early gene-related protein Fos in the gerbil brainstem were studied following stimulation of the sacculus by both hypergravity and galvanic stimulation. Head-restrained, alert animals were exposed to a prolonged (1 h) inertial vector of 2 G (19.6 m/s2) head acceleration directed in a dorso-ventral head axis to maximally stimulate the sacculus. Fos-defined immunoreactivity was quantified, and the results compared to a control group. The hypergravity stimulus produced Fos immunolabeling in the dorsomedial cell column (dmcc) of the inferior olive independently of other subnuclei. Similar dmcc labeling was induced by a 30 min galvanic stimulus of up to -100 microA applied through a stimulating electrode placed unilaterally on the bony labyrinth overlying the posterior canal (PC). The pattern of vestibular afferent firing activity induced by this galvanic stimulus was quantified in anesthetized gerbils by simultaneously recording from Scarpa's ganglion. Only saccular and PC afferent neurons exhibited increases in average firing rates of 200-300%, suggesting a pattern of current spread involving only PC and saccular afferent neurons at this level of stimulation. These results suggest that alteration in saccular afferent firing rates are sufficient to induce Fos-defined genomic activation of the dmcc, and lend further evidence to the existence of a functional vestibulo-olivary-cerebellar pathway of adaptation to novel gravito-inertial environments.

NASA Discipline Neuroscience↗

Accelerating effects of galvanic corrosion and dissimilar materials on the corrosion of 316H in NaCl-MgCl2 salt

Corrosion of materials presents a significant challenge for the long-term operation of molten salt reactors. This study aims to identify the most effective techniques for evaluating the corrosion performance of materials in molten salts, with a focus on the effects of galvanic corrosion and dissimilar materials. A reliable testing methodology for assessing material corrosion in molten chloride salts has been successfully developed. The corrosion of Alloy 316H in molten NaCl-MgCl2 salt was found to be significantly accelerated by galvanic corrosion. Additionally, the presence of dissimilar materials resulted in a slight increase in the corrosion rate of Alloy 316H in NaCl-MgCl2 salt. Microstructural characterization was utilized to understand the corrosion behavior of test samples under different conditions. Common trends observed across samples include chromium depletion and iron enrichment near corroded surfaces. Molybdenum enrichment along grain boundaries and corrosion surfaces was also frequently noted.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Combined Rotating Disk Slurry Electrodeposition–Spontaneous Galvanic Displacement for Pt-M (M = Co, Ni, and Cu) Catalyst Synthesis for the Oxygen Reduction Reaction in Alkaline Media

Here, platinum-modified first-row transition-metal catalyst (M = Ni, Co, and Cu) nanoparticles on a carbon black Vulcan XC-72R (CBV) support were synthesized using rotating disk slurry electrodeposition (RoDSE) followed by spontaneous galvanic displacement (SGD) reactions. These RoDSE–SGD catalysts were evaluated for the oxygen reduction reaction (ORR) in 0.1 M KOH using rotating disk electrode techniques. The Ni and Co RoDSEs were done by using an electrochemical applied potential of -0.75 V versus the RHE and for Cu, -0.80 V versus the RHE using a CBV slurry solution containing 0.1 M KClO 4 . These metal nanoparticles on CBV (M/CBV) catalysts were modified with a Pt precursor via a spontaneous galvanic displacement (SGD) reaction, producing a Pt-M/CBV material to catalyze the ORR in an alkaline medium. High-resolution scanning transmission electron microscopy (HR-STEM) analysis indicates that the PtM/CBV samples include M clusters and Pt single atoms. The ORR characterization measurements were done under a controlled temperature (25.0 °C) and with a mass loading of 100 μg/cm 2 on a glassy carbon (GC) rotating disk electrode at 1600 rpm. The PtCo/CBV showed the highest ORR mass activity of 0.741 A/mgPt at 0.90 V versus the reversible hydrogen electrode (RHE) compared with commercial Pt/CBV. The M/CBV RoDSE catalysts were also tested for the oxygen evolution reaction (OER), and Ni/CBV provided the lowest overpotential of 450 mV at 10 mA/cm 2 disk in 0.1 M KOH.

30 DIRECT ENERGY CONVERSION↗

Absolute Templating of M(111) Cluster Surrogates by Galvanic Exchange

The precise preparation of monodisperse nanomaterials is among the most fundamental tasks in inorganic synthesis and materials science. Achieving this goal by galvanic exchange is hardly predictable, and often results in major structural changes and polydisperse mixtures. Here, taking advantage of the enhanced stability imparted by ambiphilic carbenes, we report and rationalize the absolute templating — the complete exchange of metals in a template — of group 11 clusters across the entire coinage metal family by means of galvanic exchange. We further delineate that these species provide a molecular model for better understanding the reduction of CO 2 at M(111) coinage metal surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Giant topological longitudinal circular photo-galvanic effect in the chiral multifold semimetal CoSi

The absence of mirror symmetry, or chirality, is behind striking natural phenomena found in systems as diverse as DNA and crystalline solids. A remarkable example occurs when chiral semimetals with topologically protected band degeneracies are illuminated with circularly polarized light. Under the right conditions, the part of the generated photocurrent that switches sign upon reversal of the light’s polarization, known as the circular photo-galvanic effect, is predicted to depend only on fundamental constants. The conditions to observe quantization are non-universal, and depend on material parameters and the incident frequency. In this work, we perform terahertz emission spectroscopy with tunable photon energy from 0.2 –1.1 eV in the chiral topological semimetal CoSi. We identify a large longitudinal photocurrent peaked at 0.4 eV reaching ~550 μ A/V 2 , which is much larger than the photocurrent in any chiral crystal reported in the literature. Using first-principles calculations we establish that the peak originates only from topological band crossings, reaching 3.3 ± 0.3 in units of the quantization constant. Our calculations indicate that the quantized circular photo-galvanic effect is within reach in CoSi upon doping and increase of the hot-carrier lifetime. The large photo-conductivity suggests that topological semimetals could potentially be used as novel mid-infrared detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

An active learning framework for the rapid assessment of galvanic corrosion

The current present in a galvanic couple can define its resistance or susceptibility to corrosion. However, as the current is dependent upon environmental, material, and geometrical parameters it is experimentally costly to measure. To reduce these costs, Finite Element (FE) simulations can be used to assess the cathodic current but also require experimental inputs to define boundary conditions. Due to these challenges, it is crucial to accelerate predictions and accurately predict the current output for different environments and geometries representative of in-service conditions. Machine learned surrogate models provides a means to accelerate corrosion predictions. However, a one-time cost is incurred in procuring the simulation and experimental dataset necessary to calibrate the surrogate model. Therefore, an active learning protocol is developed through calibration of a low-cost surrogate model for the cathodic current of an exemplar galvanic couple (AA7075-SS304) as a function of environmental and geometric parameters. The surrogate model is calibrated on a dataset of FE simulations, and calculates an acquisition function that identifies specific additional inputs with the maximum potential to improve the current predictions. This is accomplished through a staggered workflow that not only improves and refines prediction, but identifies the points at which the most information is gained, thus enabling expansion to a larger parameter space. The protocols developed and demonstrated in this work provide a powerful tool for screening various forms of corrosion under in-service conditions.

36 MATERIALS SCIENCE↗

Editors’ Choice—Natural Convection Boundary Layer Thickness at Elevated Chloride Concentrations and Temperatures and the Effects on a Galvanic Couple

The natural convection boundary layer ( δ n c ) and its influence on cathodic current in a galvanic couple under varying electrolytes as a function of concentration (1 − 5.3 M NaCl) and temperature (25 °C−45 °C) were understood. Polarization scans were obtained under quiescent conditions and at defined boundary layer thicknesses using a rotating disk electrode on platinum and stainless steel 304L (SS304L); these were combined to determine δ n c . With increasing chloride concentration and temperature, δ n c decreased. Increased mass transport (Sherwood number) results in a decrease in δ n c , providing a means to predict this important boundary. Using Finite Element Modeling, the cathodic current was calculated for an aluminum alloy/SS304L galvanic couple as a function of water layer ( WL ) thickness and cathode length. Electrolyte domains were delineated, describing (i) dominance of ohmic resistance over mass transport under thin WL , (ii) the transition from thin film to bulk conditions at δ n c , and (iii) dominance of mass transport under thick WL . With increasing chloride concentration, cathodic current decreased due to decreases in mass transport. With increasing temperature, increased cathodic current was related to increases in mass transport and solution conductivity. This study has implications for sample sizing and corrosion prediction under changing environments.

25 ENERGY STORAGE↗

Excitation dynamics in galvanically coupled fluxonium circuits

We propose a near-term quantum simulator based on the fluxonium qubits galvanically coupled to form a chain. This system provides long coherence time, large anharmonicity, and strong coupling, making it suitable to study strongly interacting Ising spin models. At half-flux quantum sweet spot, the system is described by the transverse field Ising model (TFIM). We evaluate the propagation of qubit excitations through the system. As disorder increases, the excitations become localized. A single qubit measurement using the circuit QED methods is sufficient to identify localization transition without introducing tunable couplers. We argue that galvanically coupled fluxoniums provide opportunities to study localization and many-body effects in highly coherent quantum systems.

Ozguler, A. Baris↗

Galvanic Liquid Applied Coating System for Protection of Embedded Steel Surfaces from Corrosion

The corrosion of reinforcing steel in concrete is an insidious problem for the Kennedy Space Center, government agencies, and the general public. Existing corrosion protection systems on the market are costly, complex, and time-consuming to install, require continuous maintenance and monitoring, and require specialized skills for installation. NASA's galvanic liquid-applied coating offers companies the ability to conveniently protect embedded steel rebar surfaces from corrosion. Liquid-applied inorganic galvanic coating contains one ore more of the following metallic particles: magnesium, zinc, or indium and may contain moisture attracting compounds that facilitate the protection process. The coating is applied to the outer surface of reinforced concrete so that electrical current is established between metallic particles and surfaces of embedded steel rebar; and electric (ionic) current is responsible for providing the necessary cathodic protection for embedded rebar surfaces.

Curran, Joseph↗