Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fuel oil”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Rheology and engine performance of very low sulfur fuel oil blended with 10% fast pyrolysis and hydrothermal liquefaction oils in a 2-stroke crosshead engine

The performance and emissions for a downscaled single-cylinder 2-stroke crosshead engine were determined for a very low sulfur fuel oil (VLSFO) when blended with 10 wt.% fast pyrolysis (FP) or hydrothermal liquefaction (HTL) bio-intermediates. The FP and HTL oils were derived from biomass and were observed to contain lower molecular weight (MW) hydrocarbons than neat VLSFO (which was evaluated as a baseline comparison). The addition of either biofuel reduced the overall viscosity of the VLSFO. Aging tests at 50, 90, and 120°C showed that the dynamic viscosity of VLSFO increased with exposure time up to two weeks. Similar trends were observed for the FP and HTL blends, but a pronounced spike in viscosity occurred for these fuels during the early period of exposure. None of the viscosity increases exceeded the operational limits of fuel system pumps. Engine performance studies were conducted under low, medium and high load operational settings. The relative performance of the test fuels was highly dependent on operating condition. In general, the engine results for the three test fuels were similar, but modest improvements in brake thermal efficiency and brake specific fuel consumption were observed, which may be attributed to the heightened reactivity of low molecular weight fraction of the FP and HTL oils.

09 BIOMASS FUELS↗

ResStock Measure Documentation: Propane Furnace 95% AFUE and Fuel Oil Furnace 88% AFUE

This report is part of a series describing different ResStock (TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Propane Fuel 95% AFUE and Fuel Oil Furnace 88% AFUE" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Biofuels as Heavy Fuel Oil Substitutes in the Maritime Sector: Findings and Potential Pathways

The United States Department of Energy has commissioned four national laboratories to evaluate the feasibility of biofuels in the maritime sector. This effort is briefly described including the overall project goals, structure and aims. The large two-stroke crosshead engines used to power large merchant vessels were of particular interest since they can burn lower combustion quality fuels relative to four-stroke engines. This characteristic allows for consideration of pyrolysis oils and hydrothermal liquefaction (HTL) oils which are feedstock agnostic and, in the raw state, are more economical compared to distillate drop-in fuels. Pyrolysis and HTL oils are collectively known as bio-intermediates since they require additional processing for use in distillate fuel systems. The key limiting feature is that these bio-intermediate fuels will cause asphaltene precipitation when blended with heavy fuel oils (HFOs) such as very low sulfur fuel oil (VLSFO) unless they are upgraded to remove water and oxygenates. Economics are the key driver at this point in time, and preliminary techno-economic analyses (TEAs) indicate that bio-intermediates have potentially lower cost relative to other biofuels such as biodiesel and renewable diesel. Additionally, life cycle analyses (LCAs) of feedstocks and pathways show the life cycle carbon reduction benefit relative to heavy fuel oils. In addition to TEA and LCA results, we also present on the technical feasibility of these fuels. These studies have focused on the properties of biofuel blends with VLSFO that are critical to the fuel systems of maritime vessels fueled with HFOs. These properties include the compatibility with fuel system metals, viscosity, and blend stability. Aging studies with blends of VLSFO with biodiesel, HTL, and pyrolysis oils are also presented. Future efforts being planned to conduct additional biofuel testing, including the use of biofuels as pilot fuels in zero carbon shipping options fueled with ammonia and methanol, ship-based demonstrations, and bioresource competition studies.

Kass, Michael↗

Opportunities and Challenges for Hydrotreating of Catalytic Fast Pyrolysis Oil to Fuels

Catalytic fast pyrolysis (CFP) provides a versatile platform for producing fuels to combat climate change and meet decarbonizing targets. In this contribution, we will discuss the hydroprocessing of CFP oils to a variety of fuels, including sustainable aviation fuel (SAF), diesel, and marine fuel. Both standalone and co-hydroprocessing with petroleum streams will be covered. Hydrotreating CFP oil at temperatures around 400 Degrees Celsius can produce a highly deoxygenated product with oxygen contents below the detection limit. However, the quality of fuel fractions produced has been a problem, manifesting as low octane numbers for the gasoline-range fraction and low cetane numbers for the diesel-range fraction. Incorporating an initial transition zone for hydrogenation during hydrotreating was shown to dramatically increase the diesel fraction cetane number from 24 to 45. A similar approach enabled the production of a cycloalkane-rich SAF fraction meeting key ASTM 4054 guidelines with respect to density, viscosity, heating value, volatility, freeze and flash point. Over 400 hours of hydrotreating for SAF was demonstrated with no signs of catalyst bed fouling, measured by pressure drop over the catalyst bed. Compared to other fuels, marine fuel is unique in that it does not require complete deoxygenation. We investigated the minimum hydrotreating requirements to produce fuel compatible with very low sulfur fuel oil, and the results suggested 30% reduction in hydrotreating costs for this approach. Co-hydroprocessing offers an opportunity to take advantage of refinery infrastructure and economies of scale although the operation is less flexible with respect to operating conditions. Co-hydroprocessing CFP oil with petroleum streams gave efficient deoxygenation at milder conditions (e.g. at temperatures of 320 Degrees Celsius) than required for standalone hydrotreating. Over 90% incorporation of biogenic carbon in the CFP oil was confirmed by carbon-14 analysis. Hydrotreating of CFP oil, whether by standalone or co-processing, can produce a variety of fuel cuts, whose quality can be tailored by changing process conditions. Challenges remain, including long-term catalyst performance and determining CFP oil quality requirements.

09 BIOMASS FUELS↗

Tropical intertidal microbiome response to the 2024 Marine Honour oil spill

Marine fuel oil (MFO) spills in tropical coastal environments are under-characterized despite increasing risk from maritime activities. Microbial and geochemical responses to the June 2024 Marine Honour MFO spill on Singapore's intertidal sediments were analyzed in real time over 185 days. Using metagenomics and hydrocarbon profiling, microbial community shifts and hydrocarbon degradation were quantified across visibly oiled (high-impact) and clean (low-impact) sites. Microbiomes at all sites adapted rapidly to the spill through increased diversity and abundance of genes encoding alkane and aromatic compound degradation, detoxification, and biosurfactant production. The dominant hydrocarbon-degrading bacteria differed markedly from those reported in other crude oil spills and in regions with different climates. Oil deposition intensity strongly influenced microbial succession and hydrocarbon-degrading gene profiles, and this reflected early toxicity constraints in heavily oiled areas. The persistence of hydrocarbon degradation genes beyond hydrocarbon detection in sediments suggested long-term functional priming may occur. The study provides novel genome-resolved insight into the microbial response to MFO pollution, advances understanding of marine environmental biodegradation, and provides urgently needed baseline data for oil spill response strategies in Southeast Asia and beyond.

Coastal pollution↗

Evaluation of Bio-Intermediates and Other Biofuels for use in Marine Engines

This paper presents an overview of the DOE Marine Biofuel Feasibility Study to evaluate the potential of biofuels for ocean-going vessels. These vessels operate on low-cost residual fuel oils (also known as heavy fuel oils or HFO), which require significant heating and purification onboard vessels. The industry is looking at economical alternative fuels that can enhance performance from combustion/emissions, rheology, and other perspectives. Four U.S. national laboratories are collaborating to evaluate a variety of biofuels, including bio-intermediates (pyrolysis and hydrothermal liquefaction oils), biodiesel (fatty acid methyl esters or FAME), bio-residuals (FAME byproducts) for their suitability as fuels for marine diesel engines. Bio-intermediates in particular are of interest because large marine engines that operate on HFO can tolerate lowerquality, more viscous fuels and may be able to utilize these fuels with less upgrading than other applications, presenting economic advantages. The test fuels of interest are examined to determine the minimum level of upgrading required for blend compatibility with market HFOs containing high levels of asphaltenes as well as their impact on the viscosity, polymerization tendency, and combustion properties (particularly cetane number) of the fuel blends in preparation for future evaluation in engine studies.

Kaul, Brian [ORNL] (ORCID:0000000184813620)↗

Comparison of ammonia with methanol, liquefied natural gas and conventional marine transportation fuels through life cycle cost and emissions analysis

This work evaluates ammonia as a potential marine fuel for a SUEZMAX tanker and compares it with methanol, liquefied natural gas, and conventional fuel oils. The motivation arises from the need to identify low-emission, cost-competitive fuel options that can reduce greenhouse gas emissions from international shipping. The central hypothesis is that ammonia produced from renewable energy sources can achieve lower well-to-wake greenhouse gas emissions with varying life cycle costs based on the region. Life cycle assessment and techno-economic analysis were performed for a thirty-year vessel lifetime on two representative trade routes: from Saudi Arabia to Japan and from Saudi Arabia to the Netherlands. Four ammonia production pathways were assessed: natural gas, natural gas with carbon capture, natural gas pyrolysis, and renewable electricity–based synthesis. Results show that wind-based ammonia produced in Saudi Arabia achieved the lowest life cycle well-to-wake greenhouse gas emissions, between 0.58 and 0.64 million metric tons, among all fuels when using regional grid process electricity. With renewable process electricity, ammonia produced from natural gas pyrolysis in Saudi Arabia showed comparable emissions of 0.37 to 0.44 million metric tons with wind-based ammonia of 0.37 to 0.43 million metric tons. Liquefied natural gas exhibited the lowest life cycle cost, between 402 and 412 million United States dollars, and the only negative carbon abatement cost, ranging from −277 to –322 United States dollars per metric ton of greenhouse gas, compared with high sulfur fuel oil. The findings indicate that renewable ammonia offers a promising long-term pathway for reducing shipping emissions, while liquefied natural gas remains the most cost-effective option in the near term.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Residential Single-Stage Geothermal Heat Pump (3.8 COP, 18.6 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Single-Stage Geothermal Heat Pump (GHP).?Single-stage GHPs are able to reduce energy consumption by 31% for the entire stock. Additional results provided below detail how savings changes for sections of the housing stock with different base heating fuel and in different climate zones, as well as the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock (TM) is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Variable-Speed Geothermal Heat Pump (GHP). This document provides the relevant new modeling information for variable-speed systems not previously covered in either the single-stage or two-stage documents. Variable-speed GHPs represent the most efficient option available for this technology: They provide the most savings, with up to 46% for the applicable portion of the housing stock, compared to 31% for less efficient single-stage GHPs. Additional results shown here detail how the savings change for sections of the housing stock with different base heating fuels and in different climate zones, and they show the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Envelope Improvements and Advanced Air Sealing

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson, et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (GHP) (4.0 COP, 20.5 EER) With Envelope Improvements. This measure combines a two-stage GHP with envelope improvements as a single package. As this package is a combination of two other measures, this document focused on documenting the results associated with this combination of technologies, with individual measure documents for two-stage GHPs and envelope improvements providing the information on the details of these measures. When the two technologies are combined, envelope improvements can modestly reduce energy consumption by a further 10%-15%, but also reduce the required size of the ground heat exchanger and heat pump by approximately 33% on average across all sites. The cost of installing envelope improvements in these homes is likely to be more than paid for by the reduction in equipment and drilling costs in these buildings for the majority of the stock.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER). This document builds on details established in the single-stage document (Maguire et al. 2025) to detail differences in the approach to modeling this higher efficiency, but more commonly deployed, type of geothermal heat pump. Specific EnergyPlus objects and product specific curves used are highlighted along with showing the results of this measure compared to the baseline and single-speed geothermal heat pumps. Two-speed geothermal heat pumps are able to save even more energy and on utility bills than single-speed products, albeit at the expense of a higher first cost.

15 GEOTHERMAL ENERGY↗

End-Use Savings Shapes Measure Documentation: Economizers

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Upgrade Package Documentation: LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Light Emitting Diode (LED) Lighting, Heat Pump Rooftop Unit (RTU) (HP-RTU), and Air-Source Heat Pump (ASHP) Boiler, which we will refer to collectively as the "Interior Lighting and Heat Pump" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗