Standardized protocols for evaluating platinum group metal-free oxygen reduction reaction electrocatalysts in polymer electrolyte fuel cells

Platinum group metal (PGM)-free electrocatalysts for the oxygen reduction reaction at the polymer electrolyte fuel cell cathode have shown substantial improvements in activity—especially those derived from transition metals, nitrogen and carbon. However, their stability and durability remain insufficient. A key to enabling future improvements and performance comparisons lies in the development of test protocols that are relevant to the operating conditions of the fuel cell cathode, can be completed within a reasonable time and are ubiquitously adopted. Here we propose and validate such protocols, designed with special attention to typical catalyst degradation mechanisms of PGM-free catalysts. The results of the cross-laboratory validation study using two different catalysts attest to the strength and feasibility of the proposed approach. We hope that the information provided here can serve as a broad and effective platform for assessing the performance and durability of PGM-free catalysts for polymer electrolyte fuel cells.

25 ENERGY STORAGE↗

Integrated Regional Technical Exchange Centers

The Ohio Fuel Cell Coalition (OFCC) with an award from the Department of Energy Fuel Cell Fuel Cell Technologies Office (FCTO), Award No. DE-EE0006931, conducted a project to facilitate the development of a robust supply chain for fuel cell and hydrogen systems that would accelerate mass production, reduced cost, and improve performance and durability of Proton Exchange Membrane (PEM) fuel cell systems.

99 GENERAL AND MISCELLANEOUS↗

A Review of Regulations, Codes, and Standards for Hydrogen Fuel Cell Electric Bus Use on Airports

This report reviews regulations, codes, and standards to be considered for FCEB operations on airports governing vehicle safety, hydrogen infrastructure, and airport operations. Overall, the review found the existing regulatory framework largely suitable for FCEB operations on airports, with only minor gaps identified pertaining to heavy-duty vehicle fueling, operation and fire safety on airport aprons, and authorization for emergency power use.

08 HYDROGEN↗

The search for high-entropy fuel-cell catalysts using disorder descriptors

The transition to a hydrogen economy depends on efficient, affordable catalysts for fuel cells. Platinum—the industry standard for fuel-cell electrodes—is costly and scarce, highlighting the need for practical alternatives. High-entropy alloys offer vast compositional diversity and tunable properties that can mitigate these issues, yet their chemical complexity and configurational disorder have hindered rational discovery. Here, we introduce a data-driven framework that couples machine learning with first-principles disorder descriptors—including the entropy forming ability, disordered enthalpy-entropy descriptor, and electronic-structure similarity metrics to platinum—to predict alloy synthesizability and catalytic performance. These descriptors are applied for the first time in the context of fuel-cell catalyst discovery. The workflow rapidly screens more than 20 000 compositions and identifies several platinum-free candidates that are economically viable, readily scalable, and exhibit promising predicted activity. These results demonstrate that disorder descriptors are reliably predicted by machine learning models and can be effectively integrated into materials-discovery pipelines, accelerating innovation across complex compositional spaces.

fuel-cell catalysts↗

Physical model and experimental validation of a high temperature proton exchange membrane electrochemical hydrogen pump cell for efficient single-stage extraction of low concentration hydrogen gas

There is interest in valorization of existing natural gas infrastructure to facilitate the co-transportation of hydrogen via blending of hydrogen gas initially at limited concentrations of 1–20 vol% H2 and to subsequently extract hydrogen at fuel cell quality standards (SAE J2719/ISO14687-2). High temperature proton exchange membrane electrochemical hydrogen pump (HT-PEM EHP) based on phosphoric acid doped polybenzimidazole (PA-PBI) exhibits good performance at elevated temperatures (>120 °C), which provides desirable tolerance to non-methane natural gas constituents that are problematic for lower temperature based EHP. To better understand the suitability of the HT-PEM EHP for such gas separation processes, a two-dimensional model of EHP based on PA-PBI was developed. The model is validated for several relevant operating conditions and across cells with differing amounts of phosphoric acid content in the electrodes. Operando micro x-ray computed tomography (CT) imaging of an HT-PEM EHP was used to further validate physical parameters and assumptions of the model. The impacts of pressure, relative humidity of the anode feed, and concentration of feed gases on separation performance are investigated. This study shows that a specific energy of separation of 5.1 kWh/kg H2 at a hydrogen recovery factor (HRF) of 50 vol% can be achieved in a single stage with the EHP, producing fuel cell quality hydrogen purity of 99.99 vol% H2 from a 2 vol% H2/CH4 feed blend, while pressurizing the product H2 at a pressure ratio of 1.3 relative to feed pressure.

Stansberry, John M↗

Proton Conducting Silicon Oxide Membranes as a Fluorine Free Alternative to Nafion for Low Temperature Water Electrolysis

Driven by environmental and health concerns related to per- and polyfluoroalkyl substances (PFAS), there has been growing interest in developing fluorine-free proton (H + ) exchange membrane (PEM) materials for fuel cells and water electrolyzers. In this study, we present a side-by-side comparison of the key transport properties of submicron thick, PFAS-free amorphous silicon dioxide (SiO 2 ) membranes to Nafion, a fluorinated polymer electrolyte membrane that represents the industry standard for PEM fuel cells and electrolyzers. Here, measurements of proton (H + ) conductivity (σ H + ), hydrogen (H 2 ) permeability (P H 2 ), and electrical resistivity (ρ e – ) were conducted using model thin films comprised of SiO 2 membranes deposited by atomic layer deposition (ALD). Although the H + conductivity of the SiO 2 membranes is 2–3 orders of magnitude lower than Nafion, the addition of phosphorus dopants (PO x ) improves H + conductivity such that the area specific membrane resistance of thin (<50 nm) PO x -doped SiO 2 membranes is more than an order of magnitude lower than Nafion-117. Importantly, the safe operation of such nanoscale membranes within a PEM electrolyzer is feasible thanks to the low H 2 permeability of dense SiO 2 -based membranes, which are predicted to limit H 2 crossover rates to acceptable levels for pressures up to ≈ 100 bar. As a proof-of-principle demonstration, a chip-scale water electrolyzer based on 100 nm thick PO x -SiO 2 membrane is shown to achieve a current density of 2 A cm –2 at a potential of 2.5 V. If this technology can be successfully scaled up, H + conducting oxide membranes offer an attractive PFAS-free alternative to Nafion for efficient and durable water electrolysis and fuel cell technologies.

Nafion↗

Grooved electrodes for high-power-density fuel cells

Proton exchange membrane fuel cells (PEMFCs) are leading candidates to decarbonize the transport sector, but widespread deployment will require improvements in lifetime, fuel economy and cost. Here we present the grooved electrode, an alternative electrode structure that enhances PEMFC performance and durability by coupling high ionomer (ion-conducting binder) content for improved H + transport with grooves for rapid O 2 transport. Grooved electrodes provide up to 50% higher performance than state-of-the-art conventional electrodes under standard operating conditions. Fuel cell diagnostics combined with multiphysics modelling demonstrate that grooved electrodes provide facile O 2 transport despite their high ionomer content, enabling improved reaction rate uniformity. Grooved electrodes also provide improved durability, with less performance loss after carbon corrosion compared with baseline electrodes. Machine learning analysis demonstrates the potential to further optimize grooved structures for next-generation PEMFCs with enhanced performance and durability, enabling smaller and cheaper fuel cell stacks with higher fuel efficiency.

25 ENERGY STORAGE↗

Pt-Ni and Pt-Co Catalyst Synthesis Route for Fuel Cell Applications

Oxygen reduction reactions (ORRs) at the cathode are the rate-limiting step in fuel cell performance. The ORR is 100 times slower than the corresponding hydrogen oxidation at the anode. Speeding up the reaction at the cathode will improve fuel cell efficiency. The cathode material is generally Pt powder painted onto a substrate (e.g., graphite paper). Recent efforts in the fuel cell area have focused on replacing Pt with Pt-X alloys (where X = Co, Ni, Zr, etc.) in order to (a) reduce cost, and (b) increase ORR rates. One of these strategies is to increase ORR rates by reducing the powder size, which would result in an increase in the surface area, thereby facilitating faster reaction rates. In this work, a process has been developed that creates Pt-Ni or Pt-Co alloys that are finely divided (on the nano scale) and provide equivalent performance at lower Pt loadings. Lower Pt loadings will translate to lower cost. Precursor salts of the metals are dissolved in water and mixed. Next, the salt mixtures are dried on a hot plate. Finally, the dried salt mixture is heattreated in a furnace under flowing reducing gas. The catalyst powder is then used to fabricate a membrane electrode assembly (MEA) for electrochemical performance testing. The Pt- Co catalyst-based MEA showed comparable performance to an MEA fabri cated using a standard Pt black fuel cell catalyst. The main objective of this program has been to increase the overall efficiencies of fuel cell systems to support power for manned lunar bases. This work may also have an impact on terrestrial programs, possibly to support the effort to develop a carbon-free energy source. This catalyst can be used to fabricate high-efficiency fuel cell units that can be used in space as regenerative fuel cell systems, and terrestrially as primary fuel cells. Terrestrially, this technology will become increasingly important when transition to a hydrogen economy occurs.

Firdosy, Samad A.↗

Study of Hydrogen Fuel Cell Technology for Freight Rail Propulsion and Review of Relevant Industry Standards.

Alternatives to conventional diesel electric propulsion are currently of interest to rail operators. In the U.S., smaller railroads have implemented natural gas and other railroads are exploring hydrogen technology as a cleaner alternative to diesel. Diesel, battery, hydrogen fuel cell, or track electrification all have trade-offs for operations, economics, safety, and public acceptability. A framework to compare different technologies for specific applications is useful to optimize the desired results. Standards from the Association of American Railroads (AAR) and other industry best practices were reviewed for applicability with hydrogen fuel cell technology. Some technical gaps relate to the physical properties of hydrogen, such as embrittlement of metals, invisible flames, and low liquid temperatures. A reassessment of material selection, leak/flame detection, and thermal insulation methods is required. Hydrogen is less dense and diffuses more easily than natural gas, and liquid hydrogen is colder than liquefied natural gas. Different densities between natural gas and hydrogen require modifications to tank designs and flow rates. Leaked hydrogen will rise rather than pool on the ground like diesel, requiring a modification to the location of hydrogen tanks on rolling stock. Finally, the vibration and shock experienced in the rail environment is higher than light-duty vehicles and stationary applications for which current fuel cell technology has been developed, requiring a modification in tank design requirements and testing.

08 HYDROGEN↗

Molecular Engineering of Hydroxide Conducting Polymers for Anion Exchange Membranes in Electrochemical Energy Conversion Technology

Anion exchange membranes (AEMs) based on hydroxide-conducting polymers (HCPs) are a key component for anion-based electrochemical energy technology such as fuel cells, electrolyzers, and advanced batteries. Although these alkaline electrochemical applications offer a promising alternative to acidic proton exchange membrane electrochemical devices, access to alkaline-stable and high-performing polymer electrolyte materials has remained elusive until now. Despite vigorous research of AEM polymer design, literature examples of high-performance polymers with good alkaline stability at an elevated temperature are uncommon. Traditional aromatic polymers used in AEM applications contain a heteroatomic backbone linkage, such as an aryl ether bond, which is prone to degradation via nucleophilic attack by hydroxide ion. In this Account, we highlight some of the progress our group has made in the development of advanced HCPs for applications in AEMs and electrode ionomers. Here, we propose that a synthetic polymer design with an all C−C bond backbone and a flexible chain-tethered quaternary ammonium group provides an effective solution to the problem of alkaline stability. Because of the critical demand for such a polymer system, we have established new synthetic strategies for polymer functionalization and polycondensation using an acid catalyst. The first approach is to graft a cationic tethered alkyl group to pre-existing, commercially available styrene-based block copolymers. The second approach is to synthesize high-molecular-weight aromatic backbone polymers using acid-catalyzed polycondensation of arene monomers and a functionalized trifluoromethyl ketone substrate. Both strategies involve a simple two-step reaction process and avoid the use of expensive metal-based catalysts and toxic chemicals, thereby making the synthetic processes easily scalable to large industrial quantities. Both polymer systems were found to have excellent alkaline stability, confirmed by the preservation of ion exchange capacity and ion conductivity of the membrane after an alkaline test under conditions of 1 M NaOH at 80−95 °C. In addition, the advantage of good solvent processability and convenient scalability of the reaction process generates considerable interest in these polymers as commercial standard AEM candidates. AEM fuel cell and electrolyzer tests of some of the developed polymer membranes showed excellent performance, suggesting that this new class of HCPs opens a new avenue to electrochemical devices with real-world applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Durable Mn-Based PGM-Free Catalysts for Polymer Electrolyte Membrane Fuel Cells

This proposed project aims to develop and evaluate novel manganese based, nitrogen-derived, PGM-free electrocatalysts (denoted as Mn-N-C) to fully address the membrane electrolyte assemblies (MEA)’s ionomer degradation issue resulting from iron. Four thrusts will be pursed in this proposed project. First, advanced first-principles computation methods will be employed to accelerate the rational catalyst design and synthesis. Second, an effective hydro-gel method will be used to maximize atomic Mn active sites embedded in carbon matrix. Next, state-of-the art methods in fuel cell companies will be used to fabricate MEAs containing the Mn-N-C catalysts. Finally, industry standards will be rigorously followed to evaluate fuel cell performance and durability of the Mn-N-C catalysts. With successful completion of the project, it is expected that the following outcomes will be achieved. (1) A set of MEAs containing the Mn-N-C catalysts and with active area large than 50 cm 2 for independent testing, (2) testing results demonstrating that the MEAs of Mn-N-C catalysts have mass activity of 0.044 A/cm 2 at 0.9 VIR-free and H 2 /air performance of 0.50 V at 1.0 A/cm 2 ; (3) fundamental understanding of the composition-structure-property relation of the PGM-free Mn- N-C catalysts, and (4) computational data, measurement data, and publications deposited into the database of ElectroCat Consortium.

08 HYDROGEN↗

A review of functions, attributes, properties and measurements for the quality control of proton exchange membrane fuel cell components

Quality control (QC) is an essential part of fuel cell technology industrialization, providing means to reduce cost of components, enhancing the reliability of the final product, and offering specification guidance for new entrants in the supply chain. The membrane electrode assembly (MEA), including membrane, catalyst layer (CL), and gas diffusion layer (GDL), as well as bipolar plate (BP), are key components of a proton exchange membrane (PEM) fuel cell, and the attributes of each component strongly correlate with the cell performance and longevity. To ensure the quality of the fuel cell, it is of great importance to characterize the properties with respect to the standardization of component/sub-component specifications. In collaboration with the fuel cell industry, this work aims at establishing compendiums of attributes, or so-called books of attributes, of key fuel cell components for the QC of PEM fuel cells through reviewing, identifying, categorizing, and prioritizing the main attributes/properties that determine their functionalities. The books of attributes for the major PEM fuel cell components include catalyst coated membrane (CCM) as a sub-assembly, GDL, and BP. To address the full spectrum of fuel cell components, gaskets and sub-gaskets are also included.

25 ENERGY STORAGE↗

Interconnection and Interoperability Requirements of Hydrogen Assets to Enable Grid Integration

Traditionally, the inverters used for distributed energy resources (DERs) including solar, energy storage and hydrogen fuel cells are grid following assets. Grid following assets track real power and reactive power setpoints decided by either a local autonomous controller or a remote controller like a microgrid controller. In the past five years, multiple challenges have increased the need for grid forming inverters that can interface to a wide variety of energy resources. These grid forming inverters are becoming critical assets for power systems to enable the replacement of existing rotational machines and provide grid services such as grid resiliency services and black-start. Hydrogen assets (fuel cells) have the potential to successfully replace rotating machines and act as voltage and frequency master by leveraging the long-duration and seasonal energy storage capabilities of hydrogen technologies. This poster presents the progress made in budget period 1 of the proposed work. We will leverage an existing ARIES platform experimental setup to run power-hardware-in-the-loop and controller-hardware-in-the-loop experiments with grid forming fuel cell inverters to develop and document the standardization requirements.

electrolyzer↗

Hydrogen-oxygen proton-exchange membrane fuel cells and electrolyzers

Hydrogen-oxygen SPE fuel cells and SPE electrolyzers (products of Hamilton Standard) both use a Proton-Exchange Membrane (PEM) as the sole electrolyte. The SPE cells have demonstrated a ten year life capability under load conditions. Ultimate life of PEM fuel cells and electrolyzers is primarily related to the chemical stability of the membrane. For perfluorocarbon proton-exchange membranes an accurate measure of the membrane stability is the fluoride loss rate. Millions of cell hours have contributed to establishing a relationship between fluroride loss rates and average expected ultimate cell life. Several features were introduced into SPE fuel cells and SPE electrolyzers such that applications requiring greater than or equal to 100,000 hours of life can be considered. Equally important as the ultimate life is the voltage stability of hydrogen-oxygen fuel cells and electrolyzers. Here again the features of SPE fuel cells and SPE electrolyzers have shown a cell voltage stability in the order of 1 microvolt per hour. That level of stability were demonstrated for tens of thousands of hours in SPE fuel cells at up to 500 amps per square foot (ASF) current density. The SPE electrolyzers have demonstrated the same at 1000 ASF. Many future extraterrestrial applications for fuel cells require that they be self recharged. To translate the proven SPE cell life and stability into a highly reliable extraterrestrial electrical energy storage system, a simplification of supporting equipment is required. Static phase separation, static fluid transport and static thermal control will be most useful in producting required system reliability. Although some 200,000 SPE fuel cell hours were recorded in earth orbit with static fluid phase separation, no SPE electrolyzer has, as yet, operated in space.

Baldwin, R.↗

Hydrogen-oxygen proton-exchange membrane fuel cells and electrolyzers

Hydrogen-oxygen solid polymer electrolyte (SPE) fuel cells and SPE electrolyzers (products of Hamilton Standard) both use a Proton-Exchange Membrane (PEM) as the sole electrolyte. These solid electrolyte devices have been under continuous development for over 30 years. This experience has resulted in a demonstrated ten-year SPE cell life capability under load conditions. Ultimate life of PEM fuel cells and electrolyzers is primarily related to the chemical stability of the membrane. For perfluorocarbon proton exchange membranes an accurate measure of the membrane stability is the fluoride loss rate. Millions of cell hours have contributed to establishing a relationship between fluoride loss rates and average expected ultimate cell life. This relationship is shown. Several features have been introduced into SPE fuel cells and SPE electrolyzers such that applications requiring greater than or equal to 100,000 hours of life can be considered. Equally important as the ultimate life is the voltage stability of hydrogen-oxygen fuel cells and electrolyzers. Here again the features of SPE fuel cells and SPE electrolyzers have shown a cell voltage stability in the order of 1 microvolt per hour. That level of stability has been demonstrated for tens of thousands of hours in SPE fuel cells at up to 500 amps per square foot (ASF) current density.

Baldwin, R.↗

Hydrogen Detection Strategies to Support H2@SCALE - The NREL Sensor Laboratory

Hydrogen represents a major pathway to decarbonize and stabilize the national and international energy industry and select manufacturing markets. To facilitate the development of hydrogen markets, the US Department of Energy initiated H2@Scale to bring together stakeholders to advance affordable hydrogen production, transport, storage, and utilization to increase revenue opportunities in multiple energy sectors. One major impediment to hydrogen implementation is cost. To expedite the use of hydrogen in energy and other markets, the United States announced in 2021 the Hydrogen Shot, which seeks to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). As the cost of hydrogen drops, new applications will emerge that will require unique configurations of existing equipment and infrastructure, and eventually lead to advances in the generation and utilization of hydrogen. As the hydrogen economy expands, sensors and detection methods will need to adapt to changing infrastructure demands to address the primary targets of health & safety, emissions monitoring, and process control. The NREL Sensor Laboratory is playing a pivotal role in advancing the use of hydrogen sensors and detection methodologies in each of these categories to support DOE's mission for safe and efficient utilization in emerging markets. Health & safety monitors are required to ensure that operators and facilities can react to unintended hydrogen releases, either as GH2, LH2, or as a constituent of blends (e.g., natural gas or ammonia). Current detection methodologies focus on safety applications to detect near its lower flammable limit (4 vol %), and typically include point sensors in applications such as fixed or mobile detectors (e.g., personal gas monitors). Methodologies amenable for area detection include acoustic, emerging optical imaging methods, and flame detectors. Comparable detection strategies can be utilized for emissions monitoring and quantization, however few methods can simultaneously cover both low (emissions) and high (health & safety) levels. Deployment of emission level detectors will be required to 1) reduce product loss through small but potentially significant leaks from an environmental or cost perspective, 2) reduce downtime of high demand systems by early identification of eminent system failures (leaks through pump or compressor seals indicative of impending failure), and 3) address potential emission monitoring requirements that may be set by regulating bodies. The first two points should be adopted by industry to reduce the cost-of-goods-sold. The third main category for hydrogen detection relates to process control and may be advantageous for many existing applications. Two main applications are emerging. For example, the purity requirements for hydrogen that is dispensed from refueling systems for hydrogen fuel cell electric vehicles (FCEV) is rigorously regulated by the Standard SAE J2719, which prescribes maximum allowable levels of multiple impurities in the hydrogen fuel and must be verified by a regulatory body. Hydrogen contaminant detectors (HCD) integrated to the fueling station can assure this compliance. HCDs must be able operate in 100% H2 backgrounds and be able to distinguish between multiple contaminants at low ppm to low ppb levels. Secondly, as a strategy to decarbonize the natural gas grid, there are proposals to blend hydrogen with natural gas. This blending will affect transport applications (pipeline infrastructure), stationary combustion systems (turbines), and consumer and commercial appliances. In the short-term, hydrogen levels up to 20% are proposed. Variations in the hydrogen level can have dramatic impact on the combustion process and on the potential response of safety sensors. These mixtures may be regulated so that the concentration at a delivery point must be monitored with high precision. However, routine maintenance may introduce background gases such as ambient air (with water) or maintenance gases (introduced with welding processes or adhesive outgassing.) Therefore, the detection methodology must be robust enough to recover or respond to various contaminants. Several reviews can be found in literature addressing sensing and detection technologies, including their limitations and applications. However, for most applications, limitations can be alleviated by combining various detection techniques either through system integration or implementation of machine learning methods (artificial intelligence). In this presentation, we will discuss several applications, highlight their current approach for hydrogen detection, and suggest detection strategies to supplement their limitations.

ENERGY STORAGE,HYDROGEN↗

Enhancing Distribution System Resiliency Using Grid-Forming Fuel Cell Inverter: Preprint

Legacy inverters interfacing distributed energy re-sources are traditionally grid-following (GFL) in nature. GFL assets typically follow real power and reactive power set points. Recently, inverters with grid-forming (GFM) capability are gaining attention as GFM assets can increase the resiliency of the distribution system under stressed conditions. These GFM inverters can use photovoltaics, batteries, or fuel cells as their energy source. In this paper, we present information on inverters interfacing fuel cell assets, specifically with GFM capability. By introducing a fuel cell powered GFM coupled with hydrogen production and storage, the GFM can continuously provide GFM activities during periods of low renewable resource availability, and/or during power outages exceeding typical electric battery duration. Finally, we present information on the need for updates on interconnection and interoperability standards that can be leveraged by utilities for including fuel cell inverters in their asset mix.

fuel cell inverters↗

DER Cybersecurity Standards: Assessment and Gap Analysis

The purpose of this report is to share the comprehensive gap analysis of existing cybersecurity standards applicable to Distributed Energy Resources (DERs) within the electric power sector. This analysis aims to identify critical deficiencies in current standards, assess their alignment with industry needs, and provide actionable recommendations for enhancing cybersecurity measures. The scope encompasses various DER technologies, including solar, wind, energy storage, and hydrogen fuel cells, and emphasizes the significance of establishing robust cybersecurity frameworks and standards to safeguard these increasingly integrated systems. The report provides valuable insights for stakeholders in the DER ecosystem, including manufacturers, utilities, and regulators. It underscores the importance of continued development and refinement of cybersecurity standards to keep up with the technical advances in DERs and associated cybersecurity challenges. The analysis evaluated IEC, IEEE, ISA, ISO, and UL standards relevant to DER cybersecurity. Standards were assessed on their coverage of key requirements including data availability, integrity, confidentiality, access control, authentication, encryption, and system hardening. For each standard, the analysis assessed its alignment with current industry practices, regulatory compliance, effectiveness in addressing known risks, coverage of emerging risks, and how it promotes interoperability. The evaluation also considered potential integration challenges and barriers to adoption.