Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fringe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Diffusive release of uranium from contaminated sediments into capillary fringe pore water

Despite remediation efforts at the former nuclear weapons facility at the Hanford site (Washington State), leaching of uranium (U) from contaminated sediments to the ground water persists at the Hanford 300 Area. Flooding of contaminated capillary fringe sediments due to seasonal changes in the Columbia River stage has been identified as a reason of continued U supply to ground water. We investigated the release of U from Hanford capillary fringe sediments to pore water. Contaminated Hanford sediments were packed into reservoirs of centrifugal filter devices and saturated with Columbia River water for 3 to 84 days at varying solution-to-solid ratios (1:3, 1:1, 5:1, 10:1, 25:1 mL:g). After specified times, samples were centrifuged to a gravimetric water content of 0.11 ± 0.06 g g-1. Within the first three days, there was an initial rapid release of 6-9% of total U from the sediments into the pore water, independent of the solution-to-solid ratio. After 14 days of reaction, however, the experiments with the narrowest solution-to-solid ratios (1:3 and 1:1 mL:g) showed a decline in dissolved U concentrations. The removal of U from the solution phase was accompanied by removal of Ca and HCO3-. Geochemist workbench simulations, conducted using measured solution concentrations from experiments, indicated that calcite could precipitate in the 1:3 solution-to-solid ratio experiment. After the rapid initial release in the first three days for the 5:1, 10:1, and 25:1 solution-to-solid ratio experiments, there was sustained release of U into the pore water. Up to 22% of total U was released on day 84 for the 25:1 solution-to-solid ratio reaction. This sustained release of U from the sediments had diffusion-limited kinetics.

contaminated sediments↗

Fringing Analysis and Simulation for the Vera C. Rubin Observatory’s Legacy Survey of Space and Time

Abstract The presence of fringing in astronomical Charge-Coupled Device (CCD) images will have an impact on photometric quality and measurements. Yet its impact on the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) has not been fully studied. We present a detailed study on fringing for CCDs already implemented on the Rubin Observatory LSST Camera’s focal plane. After making physical measurements and knowing the compositions, we developed a model for the e2v CCDs. We present a method to fit for the internal height variation of the epoxy layer within the sensors based on fringing measurements in a laboratory setting. This method is generic enough that it can be easily modified to work for other CCDs. Using the derived fringing model, we successfully reproduce comparable fringing amplitudes that match the observed levels in images taken by existing telescopes with different optical designs. This model is then used to forecast the expected level of fringing in a single LSST y -band sky background exposure with Rubin telescope optics in the presence of a realistic time-varying sky spectrum. The predicted fringing amplitude in LSST images ranges from 0.04% to 0.2% depending on the location of a CCD on the focal plane. We find that the predicted variation in surface brightness caused by fringing in LSST y -band sky background images is about 0.6 μ Jy arcsec − 2 , which is 40 times larger than the current measurement error. We conclude that it is necessary to include fringing correction in the Rubin’s LSST image processing pipeline.

Astronomy & Astrophysics↗

On-Line Fringe Tracking and Prediction at IOTA

The Infrared/Optical Telescope Array (IOTA) is a multi-aperture Michelson interferometer located on Mt. Hopkins near Tucson, Arizona. To enable viewing of fainter targets, an on-line fringe tracking system is presently under development at NASA Ames Research Center. The system has been developed off-line using actual data from IOTA, and is presently undergoing on-line implementation at IOTA. The system has two parts: (1) a fringe tracking system that identifies the center of a fringe packet by fitting a parametric model to the data; and (2) a fringe packet motion prediction system that uses characteristics of past fringe packets to predict fringe packet motion. Combined, this information will be used to optimize on-line the scanning trajectory, resulting in improved visibility of faint targets. Fringe packet identification is highly accurate and robust (99% of the 4000 fringe packets were identified correctly, the remaining 1% were either out of the scan range or too noisy to be seen) and is performed in 30-90 milliseconds on a Pentium II-based computer. Fringe packet prediction, currently performed using an adaptive linear predictor, delivers a 10% improvement over the baseline of predicting no motion.

Wilson, Edward↗

Analysis of Fringe Field Formed Inside LDA Measurement Volume Using Compact Two Hololens Imaging Systems

We have designed and fabricated four LDA optical setups consisting of aberration compensated four different compact two hololens imaging systems. We have experimentally investigated and realized a hololens recording geometry which is interferogram of converging spherical wavefront with mutually coherent planar wavefront. Proposed real time monitoring and actual fringe field analysis techniques allow complete characterizations of fringes formed at measurement volume and permit to evaluate beam quality, alignment and fringe uniformity with greater precision. After experimentally analyzing the fringes formed at measurement volume by all four imaging systems, it is found that fringes obtained using compact two hololens imaging systems get improved both qualitatively and quantitatively compared to that obtained using conventional imaging system. Results indicate qualitative improvement of non-uniformity in fringe thickness and micro intensity variations perpendicular to the fringes, and quantitative improvement of 39.25% in overall average normalized standard deviations of fringe width formed by compact two hololens imaging systems compare to that of conventional imaging system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron beam moiré fringes imaging by image converter tube with a magnetic lens

An image converter tube with a magnetic lens was used to obtain static images of moiré fringes formed by electron beam. These moiré fringes are formed due to the interference between the anode mesh and the photocathode containing slits of various spatial frequencies. Moiré fringes are observed at an accelerating voltage of 3.5 kV requiring the magnetic excitation condition of ∼550 ampere-turns. Not only the features of the fringes are analyzed but also the change of fringe spacing as a function of the rotation angle is investigated. The experimental results are found well in agreement with the theoretical analysis. By changing the rotation angle or adjusting the excitation condition of the magnetic lens, we were able to record parallel moiré and secondary moiré fringes too. The secondary moiré fringes can be observed in the rotation angle range of −39.5° to −50.6°. The theoretical analysis indicates that the secondary moiré is formed by the interference between the photocathode slits and the 2-D periodic structure of the anode mesh. Combining our proposed moiré method with the pulse-dilation technique may potentially open the door for future applications, in various fields including, but not limited to, ultrafast electrical pulse diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transmission interference fringe ( TIF ) technique for the dynamic visualization of evaporating droplet

Here, the transmission interference fringe (TIF) technique was developed to visualize the dynamics of evaporating droplets based on the Reflection Interference Fringe (RIF) technique for micro-sized droplets. The geometric formulation was conducted to determine the contact angle (CA) and height of macro-sized droplets without the need for the prism used in RIF. The TIF characteristics were analyzed through experiments and simulations to demonstrate a wider range of contact angles from 0 to 90°, in contrast to RIF's limited range of 0–30°. TIF was utilized to visualize the dynamic evaporation of droplets in the constant contact radius (CCR) mode, observing the droplet profile change from convex-only to convex-concave at the end of dry-out from the interference fringe formation. The TIF also observed the contact angle increase from the fringe radius increase. This observation is uniquely reported as the interference fringe (IF) technique can detect the formation of interference fringe between the reflection from the center convex profile and the reflection from the edge concave profile on the far-field screen. Unlike general microscopy techniques, TIF can detect far-field interference fringes as it focuses beyond the droplet-substrate interface. The formation of the convex-concave profile during CCR evaporation is believed to be influenced by the non-uniform evaporative flux along the droplet surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

INTERFERENCE FRINGES OF SOLAR ACOUSTIC WAVES AROUND SUNSPOTS

Solar acoustic waves are scattered by a sunspot due to the interaction between the acoustic waves and the sunspot. The sunspot, excited by the incident wave, generates the scattered wave. The scattered wave is added to the incident wave to form the total wave around the sunspot. The interference fringes between the scattered wave and the incident wave are visible in the intensity of the total wave because the coherent time of the incident wave is of the order of a wave period. The strength of the interference fringes anti-correlates with the width of temporal spectra of the incident wave. The separation between neighboring fringes increases with the incident wavelength and the sunspot size. The strength of the fringes increases with the radial order n of the incident wave from n = 0 to n = 2, and then decreases from n = 2 to n = 5. The interference fringes play a role analogous to holograms in optics. This study suggests the feasibility of using the interference fringes to reconstruct the scattered wavefields of the sunspot, although the quality of the reconstructed wavefields is sensitive to the noise and errors in the interference fringes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fringing in MonoCam Y4 filter images

Here, we study the fringing patterns observed in MonoCam, a camera with a single Large Synoptic Survey Telescope (LSST) CCD sensor. Images were taken at the U.S. Naval Observatory in Flagstaff, Arizona (NOFS) employing its 1.3 m telescope and an LSST y4 filter. Fringing occurs due to the reflection of infrared light (700 nm or larger) from the bottom surface of the CCD which constructively or destructively interferes with the incident light to produce a net "fringe" pattern which is superimposed on all images taken. Emission lines from the atmosphere, dominated by hydroxyl (OH) spectra, can change in their relative intensities as the night goes on, producing different fringe patterns in the images taken. We found through several methods that the general shape of the fringe patterns remained constant, though with slight changes in the amplitude and phase of the fringes. Lastly, we also found that a superposition of fringes from two monochromatic lines taken in the lab offered a reasonable description of the sky data.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron contamination modeling and skin dose in 6 MV longitudinal field MRIgRT: Impact of the MRI and MRI fringe field

Purpose: In recent times, longitudinal field MRI-linac systems have been proposed for 6 MV MRI-guided radiotherapy (MRIgRT). The magnetic field is parallel with the beam axis and so will alter the transport properties of any electron contamination particles. The purpose of this work is to provide a first investigation into the potential effects of the MR and fringe magnetic fields on the electron contamination as it is transported toward a phantom, in turn, providing an estimate of the expected patient skin dose changes in such a modality. Methods: Geant4 Monte Carlo simulations of a water phantom exposed to a 6 MV x-ray beam were performed. Longitudinal magnetic fields of strengths between 0 and 3 T were applied to a 30 x 30 x 20 cm{sup 3} phantom. Surrounding the phantom there is a region where the magnetic field is at full MRI strength, consistent with clinical MRI systems. Beyond this the fringe magnetic field entering the collimation system is also modeled. The MRI-coil thickness, fringe field properties, and isocentric distance are varied and investigated. Beam field sizes of 5 x 5, 10 x 10, 15 x 15 and 20 x 20 cm{sup 2} were simulated. Central axis dose, 2D virtual entry skin dose films, and 70 {mu}m skin depth doses were calculated using high resolution scoring voxels. Results: In the presence of a longitudinal magnetic field, electron contamination from the linear accelerator is encouraged to travel almost directly toward the patient surface with minimal lateral spread. This results in a concentration of electron contamination within the x-ray beam outline. This concentration is particularly encouraged if the fringe field encompasses the collimation system. Skin dose increases of up to 1000% were observed for certain configurations and increases above Dmax were common. In nonmagnetically shielded cases, electron contamination generated from the jaw faces and air column is trapped and propagated almost directly to the phantom entry region, giving rise to intense dose hot spots inside the x-ray treatment field. These range up to 1000% or more of Dmax at the CAX, depending on field size, isocenter, and coil thickness. In the case of a fully magnetically shielded collimation system and the lowest MRI field of 0.25 T, the entry skin dose is expected to increase to at least 40%, 50%, 65%, and 80% of Dmax for 5 x 5, 10 x 10, 15 x 15, and 20 x 20 cm{sup 2}, respectively. Conclusions: Electron contamination from the linac head and air column may cause considerable skin dose increases or hot spots at the beam central axis on the entry side of a phantom or patient in longitudinal field 6 MV MRIgRT. This depends heavily on the properties of the magnetic fringe field entering the linac beam collimation system. The skin dose increase is also related to the MRI-coil thickness, the fringe field, and the isocenter distance of the linac. The results of this work indicate that the properties of the MRI fringe field, electron contamination production, and transport must be considered carefully during the design stage of a longitudinal MRI-linac system.

43 PARTICLE ACCELERATORS↗

Study of Quadrupole Fringe Fields in the Interaction Region of the Hadron Storage Ring of the Electron Ion Collider

Fringe fields in quadrupole magnets are usually neglected in studies of beam dynamics at accelerators. However, the extreme optical parameters present in the final focus of a collider such as the Electron–Ion Collider (EIC) may give rise to effects that should not be overlooked. The calculation of quadrupole fringe fields presented in this study follows the procedure outlined in Ref. [1], specialized to the case of a straight reference orbit (i.e., with no dipole field component). A right-handed Cartesian coordinate system is employed, with the $z$-axis aligned with the quadrupole axis and $x$ and $y$ denoting the horizontal and vertical transverse coordinates, respectively. The magnetic quadrupole field gradient, $G = \partial B_y / \partial x$, transitions from its peak value inside the quadrupole—where it is nearly independent of the longitudinal coordinate $z$—to zero at some distance beyond the magnet edge. Consequently, $G$ is treated as a function of $z$. The region over which this variation occurs is defined as the quadrupole fringe field region. The study begins with the development of a description of the magnetic field in the fringe region using a power-series expansion in the transverse coordinates $x$and $y$, consistent with the longitudinally varying gradient. A model for the $z$-dependence of the gradient is then proposed and adjusted to reproduce magnetic field data obtained from three-dimensional field calculations. To evaluate the impact of the fringe fields on beam dynamics, the corresponding vector potential is derived and incorporated into a Hamiltonian formulation of particle motion. The significance of the fringe fields is quantified by calculating the amplitude-dependent tune shift from the Hamiltonian. Using linear beam optics parameters of the Hadron Storage Ring (HSR) of the EIC, the tune shift due to the fringe fields of all quadrupole magnets in the IR-6 interaction region is evaluated. Finally, the resulting tune shifts are compared with those arising from other nonlinear field components present in the HSR.

43 PARTICLE ACCELERATORS↗

Optimized beam sculpting with generalized fringe-rate filters

We generalize the technique of fringe-rate filtering, whereby visibilities measured by a radio interferometer are re-weighted according to their temporal variation. As the Earth rotates, radio sources traverse through an interferometer’s fringe pattern at rates that depend on their position on the sky. Capitalizing on this geometric interpretation of fringe rates, we employ time-domain convolution kernels to enact fringe-rate filters that sculpt the effective primary beam of antennas in an interferometer. As we show, beam sculpting through fringe-rate filtering can be used to optimize measurements for a variety of applications, including mapmaking, minimizing polarization leakage, suppressing instrumental systematics, and enhancing the sensitivity of power-spectrum measurements. We show that fringe-rate filtering arises naturally in minimum variance treatments of many of these problems, enabling optimal visibility-based approaches to analyses of interferometric data that avoid systematics potentially introduced by traditional approaches such as imaging. Our techniques have recently been demonstrated in Ali et al., where new upper limits were placed on the 21 cm power spectrum from reionization, showcasing the ability of fringe-rate filtering to successfully boost sensitivity and reduce the impact of systematics in deep observations.

79 ASTRONOMY AND ASTROPHYSICS↗

A Model for Removing Fringes from STIS Slitless Spectra

We have developed a model that allows us to defringe slitless 2-dimensional spectra taken with the Space Telescope Imaging Spectrograph (STIS). Like all thin chip CCDs used in astronomy, the STIS CCD detector acts like an interferometer in the presence of monochromatic light, producing bright and dark fringes where there is constructive and destructive interference. These fringes are especially troublesome for spectra in the near-IR (> 7000A), reaching a peak amplitude of about 20% near 9500 A. Removing fringes from STIS spectra taken with a slit is simply a matter of dividing by an appropriate "fringe flat". A suitable flat is obtained by observing a continuum calibration source through the same slit. This however is not possible for slitless spectra, whose wavelength mapping onto the CCD detector varies with position of the object in the field. Beginning with an approximate knowledge of the STIS CCD structure, we have used 50 continuum source spectral flats taken at various central wavelengths to constrain the thickness of the detection layer at each pixel. Rom this result, we can compute a fringe flat for any astronomical source, no matter how it is positioned in the field. Flats made by this method reduce the fringing amplitude in astronomical spectra by a factor of about 5. The model fringe flat is a function of the index of refraction of each of four layers in the CCD, the thickness of each layer, and the wavelength of the light hitting each pixel. We show how the CCD structural parameters are incorporated into this "fitting function", and describe the procedure used to solve for the free parameters (the thickness of each layer at each pixel). The effectiveness of this technique will be demonstrated using slitless spectra taken as part of the STIS parallel program.

Malumuth, E.M.↗

Phasor algorithms of the SIM fringe estimation

The Space Interferometry Mission (SIM) will provide unprecedented micro-arcsecond (pas) precision to search for extra-solar planets and possible life in the universe. SIM will also revolutionize our understanding of the dynamics and evolutions of the local universe through hundred-fold improvements of inertial astrometry measurements. SIM has two so-called guide interferometers to provide stable inertial orientation knowledge of the baseline, and a science interferometer to measure target fringes. The guide and science measurements are based on the fringe phase measurements using a CCD detector. One of the key issues with SIM is to develop a new algorithm for calculation of fringe parameters. Not only astrometric results need that new algorithm, but also real-time fringe tracking requires a new method to calculate phase and visibility fast and accurately. The formulas for the phasor algorithms for fringe estimation are presented. The signal-noise ratio performances of the fringe quadratures are demonstrated. The advantages of phasor algorithms for application of fast fringe tracking and on-board data compression are discussed.

interferometry↗

Fourier domain dynamic correction method for complex optical fringes in laser spectrometers

A method is provided for Fourier domain dynamic correction of optical fringes in a laser spectrometer. The method includes Fourier transforming a background spectrum contaminated with the optical fringes to obtain baseline fringes in a frequency domain. The method includes partitioning the baseline fringes in the frequency domain to obtain partitioned baseline fringes. The method includes reconstructing the partitioned baseline fringes as separate spectra. The method includes constructing a fitting model to approximate the background spectrum by assigning a first and a second free parameter to each of partitioned baseline fringe components to respectively allow for drift and amplitude adjustments during a fitting of the fitting model. The method includes applying the fitting model to a newly acquired spectrum to provide an interpretation of the newly acquired spectrum having a reduced influence of spectral contamination on concentration retrieval.

Teng, Cheyenne↗

Fringe biasing: A variance reduction technique for optically thick meshes

Fringe biasing is a stratified sampling scheme applicable to Monte Carlo thermal radiation transport codes. The thermal emission source in optically thick cells is partitioned into separate contributions from the cell interiors (where the likelihood of the particles escaping the cells is virtually zero) and the 'fringe' regions close to the cell boundaries. Thermal emission in the cell interiors can now be modelled with fewer particles, the remaining particles being concentrated in the fringes so that they are more likely to contribute to the energy exchange between cells. Unlike other techniques for improving the efficiency in optically thick regions (such as random walk and discrete diffusion treatments), fringe biasing has the benefit of simplicity, as the associated changes are restricted to the sourcing routines with the particle tracking routines being unaffected. This paper presents an analysis of the potential for variance reduction achieved from employing the fringe biasing technique. The aim of this analysis is to guide the implementation of this technique in Monte Carlo thermal radiation codes, specifically in order to aid the choice of the fringe width and the proportion of particles allocated to the fringe (which are interrelated) in multi-dimensional simulations, and to confirm that the significant levels of variance reduction achieved in simulations can be understood by studying the behaviour for simple test cases. The variance reduction properties are studied for a single cell in a slab geometry purely absorbing medium, investigating the accuracy of the scalar flux and current tallies on one of the interfaces with the surrounding medium. (authors)

97 MATHEMATICS AND COMPUTING↗

Comparison of infinite and wedge fringe settings in Mach Zehnder interferometer for temperature field measurement

Interferometric method, which utilizes the interference of coherent light beams, is used to determine the temperature distribution in the vicinity of a vertical heater plate. The optical components are arranged so as to obtain wedge fringe and infinite fringe patterns and isotherms obtained in each case were compared. In wedge fringe setting, image processing techniques has been used for obtaining isotherms by digital subtraction of initial parallel fringe pattern from deformed fringe pattern. The experimental results obtained are compared with theoretical correlations. The merits and demerits of the fringe analysis techniques are discussed on the basis of the experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigating the origin of the far-field reflection interference fringe (RIF) of microdroplets

We show that the reflection interference fringe (RIF) is formed on a screen far away from the microdroplets placed on a prism-based substrate, which have low contact angles and thin droplet heights, caused by the dual convex–concave profile of the droplet, not a pure convex profile. The geometric formulation shows that the interference fringes are caused by the optical path difference when the reflected rays from the upper convex profile at the droplet–air interface interfere with reflection from the lower concave profile at oblique angles lower than the critical angle. Analytic solutions are obtained for the droplet height and the contact angle out of the fringe number and the fringe radius in RIF from the geometric formulation. Furthermore, the ray tracing simulation is conducted using the custom-designed code. The geometric formulation and the ray tracing show excellent agreement with the experimental observation in the relation between the droplet height and the fringe number and the relation between the contact angle and the fringe radius. This study is remarkable as the droplet's dual profile cannot be easily observed with the existing techniques. However, the RIF technique can effectively verify the existence of a dual profile of the microdroplets in a simple setup. In this work, the RIF technique is successfully developed as a new optical diagnostic technique to determine the microdroplet features, such as the dual profile, the height, the contact angle, the inflection point, and the precursor film thickness, by simply measuring the RIF patterns on the far-field screen.

42 ENGINEERING↗