Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Frequency selective infrared sensors

A frequency selective infrared (IR) photodetector having a predetermined frequency band. The exemplary frequency selective photodetector includes: a dielectric IR absorber having a first surface and a second surface substantially parallel to the first surface; an electrode electrically coupled to the first surface of the dielectric IR absorber; and a frequency selective surface plasmonic (FSSP) structure formed on the second surface of the dielectric IR absorber. The FSSP structure is designed to selectively transmit radiation in the predetermined frequency band that is incident on the FSSP structure substantially independent of the angle of incidence of the incident radiation on the FSSP structure.

36 MATERIALS SCIENCE↗

Homonuclear dipolar recoupling of arbitrary pairs in multi-spin systems under magic angle spinning: A double-frequency-selective ZQ-SEASHORE experiment

We introduce a useful method for measuring the internuclear distances within arbitrarily selected pairs of like nuclei in dipolar-coupled multi-spin systems. The approach uses a combination of the zero-quantum shift-evolution-assisted selective homonuclear recoupling (ZQ-SEASHORE) technique developed by Hu and Tycko [ J. Chem. Phys. 2009, 131, 045101] and double-frequency-selective radio-frequency pulse. The double-frequency-selective pulse inverts polarizations of two spins simultaneously, and thus applications of the method presented here are only limited by the spectral resolution, and not by the number of interacting spins. Our experiments demonstrate the validity of the method and present analytical expressions for the dephasing curve.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino, Rafael [Unlisted]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Full Waveform Inversion with Multisource Frequency Selection of Marine Streamer Data

The theory and practice of multisource full waveform inversion of marine supergathers are described with a frequency-selection strategy. The key enabling property of frequency selection is that it eliminates the crosstalk among sources, thus overcoming the aperture mismatch of marine multisource inversion. Tests on multisource full waveform inversion of synthetic marine data and Gulf of Mexico data show speedups of 4× and 8×, respectively, compared to conventional full waveform inversion.

58 GEOSCIENCES↗

Optically transparent frequency selective surfaces on flexible thin plastic substrates

A novel 2D simple low cost frequency selective surface was screen printed on thin (0.21 mm), flexible transparent plastic substrate (relative permittivity 3.2). It was designed, fabricated and tested in the frequency range 10-20 GHz. The plane wave transmission and reflection coefficients agreed with numerical modelling. The effective permittivity and thickness of the backing sheet has a significant effect on the frequency characteristics. The stop band frequency reduced from 15GHz (no backing) to 12.5GHz with polycarbonate. The plastic substrate thickness beyond 1.8mm has minimal effect on the resonant frequency. While the inner element spacing controls the stop-band frequency, the substrate thickness controls the bandwidth. The screen printing technique provided a simple, low cost FSS fabrication method to produce flexible, conformal, optically transparent and bio-degradable FSS structures which can find their use in electromagnetic shielding and filtering applications in radomes, reflector antennas, beam splitters and polarizers.

36 MATERIALS SCIENCE↗

Fabrication of frequency selective surface for band stop IR-filter

Fabrication and characterization of frequency selective surfaces (FSS) on silicon dioxide/ silicon is reported. Electron beam lithography based techniques are used for the fabrication of periodic slot structure in tungsten layer on silicon dioxide/silicon. The fabrication process consists of growth of SiO{sub 2} on silicon, tungsten deposition, electron beam lithography, and wet etching of tungsten. The optical characterization of the structural pattern was carried out using fourier transform infrared spectroscopy (FTIR). The reflectance spectra clearly show a resonance peak at 9.09 µm in the mid infrared region. This indicates that the patterned surface acts as band stop filter in the mid-infrared region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Frequency selective tunable spin wave channeling in the magnonic network

Using the space-resolved Brillouin light scattering spectroscopy, we study the frequency and wavenumber selective spin-wave channeling. We demonstrate the frequency selective collimation of spin-wave in an array of magnonic waveguides, formed between the adjacent magnonic crystals on the surface of yttrium iron garnet film. We show the control over spin-wave propagation length by the orientation of an in-plane bias magnetic field. Fabricated array of magnonic crystal can be used as a magnonic platform for multidirectional frequency selective signal processing applications in magnonic networks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Background cancellation for frequency-selective quantum sensing

A key challenge in quantum sensing is the detection of weak time dependent signals, particularly those that arise as specific frequency perturbations over a background field. Conventional methods usually demand complex dynamical control of the quantum sensor and heavy classical post-processing. We propose a quantum sensor that leverages time independent interactions and entanglement to function as a passive, tunable, thresholded frequency filter. By encoding the frequency selectivity and thresholding behavior directly into the dynamics, the sensor is responsive only to a target frequency of choice whose amplitude is above a threshold. This approach circumvents the need for complex control schemes and reduces the post-processing overhead.

Puig, Ricard [Los Alamos; Ecole Polytechnique, Lau↗

Dynamics of frequency-selective operation of a CO laser tunable in a wide spectral range

This paper presents a computational/theoretical analysis of the generation of a single pulse by a frequency-selective electron-beam sustained discharge CO laser. The calculations have been performed using a theoretical model in which the entire set of VV exchange processes involving CO molecules at high vibrational levels is taken into full account. We present calculated pulse shapes for a wide range of transitions, including transitions between high vibrational levels, and examine the possibility of raising the laser output intensity by optimising the density and composition of the gain medium. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Equivalent circuit for VO{sub 2} phase change material film in reconfigurable frequency selective surfaces

We developed equivalent circuits of phase change materials based on vanadium dioxide (VO{sub 2}) thin films. These circuits are used to model VO{sub 2} thin films for reconfigurable frequency selective surfaces (FSSs). This is important as it provides a way for designing complex structures. A reconfigurable FSS filter using VO{sub 2} ON/OFF switches is designed demonstrating −60 dB isolation between the states. This filter is used to provide the transmission and reflection responses of the FSS in the frequency range of 0.1–0.6 THz. The comparison between equivalent circuit and full-wave simulation shows excellent agreement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An upgraded frequency-selectable laser source (FLS) calibrator for CMB bandpass characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from the uncertainty in instrument bandpass calibration. Uncertainties in bandpass can limit foreground removal and spectral fitting, which are critical for inflationary and galaxy cluster measurements. CMB experiments currently use Fourier Transform Spectrometers (FTSes) to measure instrument bandpasses. However, FTS systems are currently systematics-limited, so significant improvements in bandpass measurements require novel calibrators. To this end, we developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency coupled to a system that allows for laser power attenuation. Following initial testing with the first FLS prototype, we developed an upgraded version of the calibrator with improved performance. We present the upgrades to the FLS calibrator, the characterization of the upgraded calibrator and new laser source, and plans for testing with microwave instruments in the field.

Saunders, Lauren J. [Fermilab] (ORCID:000000016367↗

Frequency-Selectable Laser Source (FLS) Calibrator for CMB Bandpass Characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from our detector bandpass calibration. Uncertainties in bandpass can severely limit our measurements by limiting foreground removal and spectral fitting, which is particularly important for high-$\ell$ observations like cluster science using the Sunyaev-Zeldovich (SZ) effect. Currently, CMB experiments typically use a Fourier Transform Spectrometer (FTS) to measure the detector bandpasses. However, the resolution of the FTS is dependent on the length of the interferometer arms, leading to a need for increasingly large FTS instruments as CMB experiments require tighter constraints on detector bandpasses. Additionally, systematic effects like shifts in bandpass shape from uneven illumination from the FTS further limit the calibration uncertainties. As a complement to the FTS, we have developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency housed in a calibrator that allows for varying degrees of laser power attenuation. We present several tests used to characterize the first prototype design of the FLS calibrator, as well as the improvements to the calibrator design currently underway.

Saunders, Lauren [Fermilab]↗

Highly Sensitive Measurements of Methylene Dynamics With a Frequency-Selective Double-Quantum Sideband Method

Probing the fast dynamics of surface sites using NMR spectroscopy is highly challenging owing to the sites’ high dilution and the difficulties often associated with isotopic enrichment. Intra-CH 2 1 H- 1 H dipolar couplings are ideal probes of motions given that they only involve 1 H’s and the tensor has a well-defined size and orientation. Here, we introduce a frequency-selective variant of the double-quantum sideband method to measure like-spin 1 H- 1 H dipolar coupling constants. The experiment dramatically reduces the instrument time required to measure dynamically-averaged intra-CH 2 dipolar couplings. We demonstrate the performance of the sequence using silica-supported silanes as model highly-mobile surface species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Frequency-Selectable Laser Source for Cosmic Microwave Background Experiments

Cosmic Microwave Background (CMB) experiments measure remnant radiation from the early universe and use that data to determine fundamental properties of the universe. We can constrain key parameters, such as \textit{r}, the cosmic tensor-to-scalar ratio, and $N_\text{eff}$, the effective number of relativistic species, by analyzing the CMB power spectra. Improving our measurements of the CMB requires improving our instrument systematics, one of the most important of which is detector bandpass. Current experiments use a Fourier Transform Spectrometer (FTS) to measure bandpass. However, the FTS is systematics limited, and cannot achieve the accuracy needed to make improved CMB measurements. For this reason, we are developing a new instrument, the Frequency-Selectable Laser Source (FLS) to decrease the uncertainty in bandpass by an order of magnitude. In this paper, we describe work completed to support the version 2 upgrade to the FLS. Using ray-tracing software, we modeled the FLS optics to set physical tolerances for the new design. We also discuss the laser calibration, and future work to be completed in further development of the FLS upgrade.

Rosen-Turits, Gabriel M. [Fermilab]↗

Frequency-Selectable Laser Source (FLS) for Cosmic Microwave Background Experiments

Cosmic Microwave Background (CMB) experiments measure remnant radiation from the early universe and use that data to determine fundamental properties of the universe. We can constrain key parameters, such as \textit{r}, the cosmic tensor-to-scalar ratio, and $N_\text{eff}$, the effective number of relativistic species, by analyzing the CMB power spectra. Improving our measurements of the CMB requires improving our instrument systematics, one of the most important of which is detector bandpass. Current experiments use a Fourier Transform Spectrometer (FTS) to measure bandpass. However, the FTS is systematics limited, and cannot achieve the accuracy needed to make improved CMB measurements. For this reason, we are developing a new instrument, the Frequency-Selectable Laser Source (FLS) to decrease the uncertainty in bandpass by an order of magnitude. In this paper, we describe work completed to support the version 2 upgrade to the FLS. Using ray-tracing software, we modeled the FLS optics to set physical tolerances for the new design. We also discuss the laser calibration, and future work to be completed in further development of the FLS upgrade.

Rosen-Turits, Gabriel M.↗

Frequency-selective excitation of high-wavevector phonons

We demonstrate here the selective excitation of a narrow frequency band of TA phonons throughout the Brillouin zone of germanium using a sinusoidally modulated picosecond laser pulse. The pulse is produced through the combination of two chirped and delayed pulses using a stabilized interferometer. The phonon excitations are probed by time- and momentum- resolved x-ray diffuse scattering.

36 MATERIALS SCIENCE↗