Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fractional calorimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Combining Fractional Calorimetry with Statistical Methods to Characterize Thermal Runaway

Fractional thermal runaway calorimetry (FTRC) techniques were introduced to examine thermal runaway (TR) behavior of lithium-ion (Li-ion) cells. Specifically, FTRC considers the total energy released vs. the fraction of the total energy that is released through the cell casing vs. through the ejecta material. This device has been expanded to universally support FTRC testing of additional cell types including 21700-format, D-Cell format, and large prismatic format Li-ion cells. The TR behavior as influenced by cell format, manufacturer, chemistry, capacity, and in situ safety features are described in this presentation.

Walker, William↗

Combining Fractional Calorimetry with Statistical Methods to Characterize Thermal Runaway

Thermal management systems designed to handle the impacts of thermal runaway (TR) are key to safe operation of lithium-ion (Li-ion) batteries. Critical factors for optimizing these systems include the total energy released and the fraction of the total energy that is released through the cell casing versus through the ejecta material. A unique calorimeter, designed to characterize said factors, was utilized to examine the TR behavior of a variety of 18650-format Li-ion cells. Statistical methods were implemented to interpret the data.

Walker, William↗

Comparative Analysis of Thermal Runaway Heat Output as a Function of Trigger Mechanism and Cell Format

High demand for energy storage systems across many fields drives the need for safe and reliable Li-ion batteries. In order to assess the risk of using such batteries in various applications, many types of abuse tests have been developed to push battery cells to their limits and learn how they fail. In this work, internal short circuit (ISC) tests, nail penetration tests, and thermal tests were used to trigger thermal runaway in D-cell, 18650, and 21700 Li-ion cells. High-speed radiography was used to gain insight to the propagation of thermal runaway throughout the cell, while calorimetric and thermal data were recorded in real time. Post-test disassembly of the calorimeter allowed for any mass ejected from the cell to be analyzed and the distribution of mass through the calorimeter to be determined. The impact of cell geometry and trigger mechanism on post-test mass distribution, thermal runaway propagation and internal cell temperature are discussed.

Lithium-ion battery; thermal runaway; calorimetry;↗

Enhancing Battery Safety with Fractional Thermal Runaway Calorimetry

Effective thermal management systems, designed to handle the impacts of thermal runaway (TR) and to prevent cell-to-cell propagation, are key to safe operation of lithium-ion (Li-ion) battery assemblies. Critical factors for optimising these systems include the total energy released during a single cell TR event and the fraction of the total energy that is released through the cell casing versus through the ejecta material. A unique fractional thermal runaway calorimeter (FTRC), designed to characterise said critical factors, was utilised to examine the TR behaviour of Li-ion cells). Delegates will be provided with an in-depth discussion on what fractional thermal runaway calorimetry is and how it benefits the development of safe and optimised battery assemblies that protect against thermal runaway. Delegates will see calorimetry data associated with a variety of Li-ion cells. Data presented is relevant to any industry that utilises high-energy Li-ion cells in closed environments and has a need to focus on safety.

Walker, William↗

Coupling Fractional Thermal Runaway Calorimetry (FTRC) Results with Statistical Analysis Methods

Important factors to consider when optimizing Lithium-ion (Li-ion) battery thermal management systems, from a battery safety perspective, include the total energy released during a single cell thermal runaway (TR) event and the fraction of the total energy that is released through the cell casing versus through the ejecta material. A fractional thermal runaway calorimeter (FTRC) was used to examine the TR behavior of the following 18650-format Li-ion cells: (1) Molicel 18650-J, (2) LG 18650-HG2, (3) Samsung 18650-30Q, (4) 3.35 Ah LG 18650 test cell, (5) Sony 18650-VC7, and (6) LG 18650-MJ1. These cells were intentionally selected to represent a variety of manufacturers, chemistries, capacities, and safety features. Because of the large number of random and non-random variables associated with the FTRC results, a linear regression model, developed using engineering statistical methods, was utilized to provide final interpretation of the TR behavior for each cell type and design variable combination.

Walker, William↗

Battery Failure Databank

The Battery Failure Databank contains thermal runaway results gathered from nearly 300 small format fractional thermal runaway calorimetry (S-FTRC) experiments. A majority of these experiments were conducted at synchrotron facilities where high-speed x-ray videography was conducted of the cell while tested inside of the S-FTRC. The databank is a two-component system which consists of a Microsoft ExcelTM spreadsheet which provides S-FTRC results in tabular format and a radiographic video library containing the high-speed x-ray videos. Overall, the databank provides thermal results from S-FTRC experiments conducted on a mixture of commercially available lithium-ion (Li-ion) cells and specialized Li-ion test cells with varying cell format (18650, 21700, and D-cell) and trigger mechanism (heaters, heaters plus internal short circuiting device, and nail penetration). The radiography video component provides insight into the initiation and propagation of TR in the cells, in addition to consequences of TR measured by the FTRC. Fractions of mass ejected for the cell types are separated into regimes based on the different failure modes of the cells, such as purely venting, partial ejection, and total ejection. With knowledge of the rate and characterization of the internal degradation of the cells during TR, and the amounts of mass ejected and unrecovered, the extent of TR, and therefore the mitigation of TR, is revealed relative to cell types and failure modes.

Lithium-ion battery↗

Development and Application of a Novel Calorimetry Technique for the Study of Lithium-Ion Cell Thermal Runaway

Lithium-ion battery technology is widely used and is attractive due to demonstrated specific energies in the 200-300 W-hr/kg range. The excellent, mass-efficient energy storage capability of lithium-ion batteries has led to their use on many aerospace platforms. However, lithium-ion batteries can exhibit thermal runaway behavior wherein stored electrochemical energy is released rapidly as a result of thermal or mechanical failure, electrochemical abuse, internal or external short circuiting. A single cell undergoing thermal runaway within a battery has the potential to induce thermal runaway in adjacent cells if heat dissipation is not properly managed and can result in a catastrophic failure of the battery. Designing batteries that are resistant to thermal runaway propagation requires an understanding of, not only, total energy yield but also the means by which that energy is liberated from the cell. While Accelerating Rate Calorimetry and other techniques provide total thermal runaway energy yield, they do not provide the fractional breakdown of energy liberated via conduction through the cell casing from that which is vented from the cell as hot gases and effluents. Such data are needed to inform battery thermal design and analysis. To measure the total energy yield, the fraction conducted through the cell casing, and the fraction lost due to gases and effluents, NASA developed Fractional Thermal Runaway Calorimetry (FTRC). Two calorimeters have been developed and demonstrated, the Small-format- and Large-format Fractional Thermal Runaway Calorimeters (S-FTRC and L-FTRC, respectively). The technique has been successfully applied to small- and large-format cells (2.4-3.5 Ah and >100 Ah capacity, respectively) and has given new insights into Li-ion cell thermal runaway. Development of the calorimeters is discussed and results from the initial thermal runaway testing campaigns are presented.

Lithium-Ion Cell↗

The effects of zinc addition on the environmental stability of Al-Li alloys

It was found that relatively small addition of Zn can improve the stress corrosion cracking (SCC) resistance of Al-Li alloys. However, the mechanism by which this is accomplished is unclear. The role that Zn plays in altering the behavior of Alloy 8090 is investigated. Early results suggest that Zn additions increase the volume fraction of delta(Al3Li) precipitation and differential scanning calorimetry (DSC) on these alloys confirms this. The four alloys studied each had initial compositions lying in the 8090 window and had varying amounts of Zn added to them. Alloy 8090, like other Al-Li alloys, displays a delta' precipitate free zone (PFZ) upon artificial aging along the grain and subgrain boundaries. However Zn additions greatly decreased or eliminated a delta' PFZ after 100 hours at 160 C. This implies that the subgrain boundary precipitation kinetics are being altered and suppressed. Furthermore, there appears to be a window of Zn concentration above which a delta ' PFZ can reappear with the nucleation and growth of a currently unidentified precipitate on the boundaries. Polarization experiments were performed and the results presented. The experiments were performed in deaerated 3.5 w/o NaCl in both as received (T3) condition and at peak aging of 100 hours at 160 C. The aging profile was determined via Vickers Hardness tests.

Kilmer, Raymond J.↗

Estimation of the nucleation rate by differential scanning calorimetry

A realistic computer model is presented for calculating the time-dependent volume fraction transformed during the devitrification of glasses, assuming the classical theory of nucleation and continuous growth. Time- and cluster-dependent nucleation rates are calculated by modeling directly the evolving cluster distribution. Statistical overlap in the volume fraction transformed is taken into account using the standard Johnson-Mehl-Avrami formalism. Devitrification behavior under isothermal and nonisothermal conditions is described. The model is used to demonstrate that the recent suggestion by Ray and Day (1990) that nonisothermal DSC studies can be used to determine the temperature for the peak nucleation rate, is qualitatively correct for lithium disilicate, the glass investigated.

Kelton, Kenneth F.↗

Development of Methods of Characterizing Coal in Its Plastic State

Coal in its plastic state (typically 400-460 C) was examined by the isothermal Gieseler plastometry of seven selected coals of widely varying plastic properties. Kinetic models were proposed for the isothermal plastometric curves. Plastic behavior was compared with a variety of laboratory analyses and characterizations of these coals, including classical coal analysis; mineral analysis; microstructural analysis (extractable fractions, surface area measurement, and petrographic analysis); and thermal analysis (thermogravimetric analysis, thermomechanical analysis, and differential scanning calorimetry). The phenomenon of a sharp, large, poorly reproducible exotherm in the differential scanning calorimetric analysis of coking coals was examined. Several coal extrudates show mineral distribution, organic maceral composition and overall calorific value to be little affected by 800 F extrusion. Volatile matter and plastic properties are moderately reduced, and the network structure (as gauged by extractables) appears to be slightly degraded in the extrusion process.

Lloyd, W. G.↗

The study of the thermal behavior of a new semicrystalline polyimide

Thermal properties of a new semicrystalline polyimide synthesized from 3,3',4,4' benzophenone tetracarboxylic dianhydride (BTDA) and 2,2 dimethyl 1,2-(4 aminophenoxy) propane (DMDA) were studied. Heat capacities in the solid and liquid states of BTDA-DMDA were measured. The heat capacity increase at the glass transition temperature (T sub g = 230 C) is 145 J/(C mol) for amorphous BTDA-DMDA. The equilibrium heat of fusion of the BTDA-DMDA crystals was obtained using wide angle X ray diffraction and differential scanning calorimetry measurements, and it is 75.8 kJ/mol. Based on the information of crystallinity and the heat capacity increase at T sub g, a rigid amorphous fraction is identified in semicrystalline BTDA-DMDA samples. The rigid amorphous fraction represents an interfacial region between the crystalline and amorphous states. In particular, this fraction increases with the crystallinity of the sample which should be associated with crystal sizes, and therefore, with crystal morphology. It was also found that this polymer has a high temperature crystal phase upon annealing above its original melting temperature. The thermal degradation activation energies are determined to be 154 and 150 kJ/mol in nitrogen and air, respectively.

Cheng, Stephen Z. D.↗

Cellular monotectic model solidification

Succinonitrile (sn) was purified to a superior level using a fractional recrystallization method. The melting point of the best twice recrystallized sn was not raised by following with double distillation. This was tested using differential scanning calorimetry. The peak shape on melting also proved that double distillation after double recrystallization did not improve the quality. Stability and phase diagrams for succinonitrile and glycerol are presented.

Kaukler, William F.↗

Numerical Model for Isothermal and Non-Isothermal Crystallization of Liquids and Glasses

A new numerical model of isothermal and non-isothermal first order phase transformations, such as the crystallization of liquids and glasses, is presented. This model computes directly the volume fraction transformed, taking into account time-dependent nucleation rates and cluster-size-dependent growth velocities. The model is applied to the crystallization of lithium disilicate glass, using the appropriate kinetic and thermodynamic parameters. The model is used (1) to determine the validity of common methods for computing the volume fraction transformed as a function of time in isothermal experiments when a time-dependent nucleation rate is expected, (2) to simulate non-isothermal differential scanning calorimetry (DSC) studies of glass devitrification as a function of scan rate, and (3) to compute the effect of preannealing on the DSC peak parameters. A novel behavior of the nucleation rate with scan rate is predicted, arising because the relaxation of the cluster distribution cannot be described by a single relaxation time. Comparisons of the calculations with experimental data on this glass demonstrate the validity of the model.

Kelton, K. F.↗

The formation of lunar glasses

The work investigates experimentally the conditions required to form glasses out of a number of lunar compositions. Viscous flow and crystallization behavior of several compositions were studied over a wide range of temperature. These data exhibit the form generally found for glass-forming liquids. Combining growth rate with viscosity data, the fraction of preferred growth sites on the crystal-liquid interfaces is found to increase with increasing undercooling for all lunar compositions. The detailed forms of the kinetic data are predicted by recent computer simulations of crystal growth. Calorimetry studies indicate that lunar orange soil was formed under conditions of much slower cooling rate than 1000 deg K per sec.

Uhlmann, D. R.↗

Calorimeter Heat Flux Trends in NASA’s Subscale Rotating Detonation Rocket Engine

A calorimeter-style rotating detonation rocket engine (RDRE) outer chamber body was designed, additively manufactured in GRCop-42, and hot-fire tested in test cell 105 at NASA Marshall Space Flight Center (MSFC) in Huntsville, AL in August 2024. Steady-state, spatially resolved heat flux and chamber pressure were measured at 13 and 9 locations from the injector face, respectively, for a variety of test conditions and hardware configurations with gaseous methane and oxygen propellants. The 2-in. diameter highly instrumented design, enabled by metal additive manufacturing (AM), allowed for simultaneous measurement of heat flux and chamber pressure through 44 long duration hot-fire tests without failure. Of the 44 tests, only 3 of the tests featured chamber pressures below 100 psia and are discussed in this work. Heat flux trends for this subscale hardware are explored with respect to local propellant mass flux for several different injectors, chamber lengths, and chamber “subsonic” area ratios (contraction ratios). Results show that for increasing chamber pressure, a reduced amount of energy per kilogram of propellant is transferred to the wall. Switching injectors affects the near-face heat flux and chamber pressure profiles. Chamber length does not noticeably affect the heat flux profile but increases bulk heat load. A subsonic area ratio greater than 1 reduces heat losses to the wall compared to a straight annulus case. Equivalence ratio shift did not significantly affect heat flux. Computational fluid dynamics (CFD) and conjugate heat transfer (CHT) analyses were performed to delineate 3-D heat transfer and coolant mass flow maldistribution effects and create a calorimeter transfer function to transform heat flux data and mitigate the profile distortions. Additional CFD/CHT simulations were performed using experimental data as boundary conditions to assess local nucleate boiling propensity during testing and to assess projected hot wall temperatures for future fatigue assessment. Vapor fractions were observed locally for several cases. It is anticipated that this effort will provide a common framework for coolant system design/analysis in calorimeter systems for rocket-based and air-breathing combustors, ensuring greater repeatability in calorimetry measurements across the research community.

Joseph Hernandez-McCloskey↗