Engineering PapersSearch

SEARCH · Engineering Papers

Results for “fluorescence spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Detectability limit and uncertainty considerations for laser induced fluorescence spectroscopy in flames

Laser induced fluorescence spectroscopy of flames is discussed, and derived uncertainty relations are used to calculate detectability limits due to statistical errors. Interferences due to Rayleigh scattering from molecules as well as Mie scattering and incandescence from particles have been examined for their effect on detectability limits. Fluorescence trapping is studied, and some methods for reducing the effect are considered. Fluorescence trapping places an upper limit on the number density of the fluorescing species that can be measured without signal loss.

Daily, J. W.

Two-photon-excited fluorescence spectroscopy of atomic fluorine at 170 nm

Two-photon-excited fluorescence spectroscopy of atomic fluorine is reported. A doubled dye laser at 286-nm is Raman shifted in H2 to 170 nm (sixth anti-Stokes order) to excite ground-state 2P(0)J fluorine atoms to the 2D(0)J level. The fluorine atoms are detected by one of two methods: observing the fluorescence decay to the 2PJ level or observing F(+) production through the absorption of an additional photon by the excited atoms. Relative two-photon absorption cross sections to and the radiative lifetimes of the 2D(0)J states are measured.

Herring, G. C.

Demonstration of x-ray fluorescence spectroscopy as a sensitive temperature diagnostic for high-energy-density physics experiments

We present the use of x-ray fluorescence spectroscopy (XFS) to a sensitive temperature diagnostic in shocked foams at temperatures of 30–75 eV. Cobalt-doped foams were shock compressed using a planar drive at the OMEGA laser facility and photo-pumped with a Zn He⁢𝛼 x-ray source. Analysis of the resulting cobalt 𝐾⁢𝛽 x-ray fluorescence spectra using collisional radiative codes allows the temperature to be determined in the shocked foams. Furthermore, this method provides a sensitive and robust technique to determine temperatures in high-energy-density physics experiments in the tens of electronvolts temperature range. In these experiments, we find that radiation hydrodynamic simulations predict a lower temperature in the shocked foams compared to analysis of the XFS data using collisional radiative models. Although additional experiments with an independent temperature diagnostic to absolutely calibrate XFS spectra for these conditions will be required to resolve this discrepancy, these results demonstrate the excellent temperature sensitivity of XFS spectra for high-energy-density physics experiments.

Atomic spectra

Remote quantification of Cm(III) and HNO 3 by fluorescence spectroscopy and chemometrics

A unique approach to remotely quantify Cm(III) (0–100 µg mL −1 ) in HNO 3 (1–12 M) using steady-state laser fluorescence spectroscopy and multivariate regression models was developed. Photoluminescence is amenable to remote measurements using fiber-optic cables and is sensitive to numerous lanthanide and actinide species. In-line measurements can provide feedback to support complex processing in harsh environments (e.g., hot cells) to help guide and optimize radiochemical separations. In this work, Cm(III) spectra were acquired remotely in a glove box as a function of HNO 3 concentration to better understand spectral characteristics and evaluate the utility of multivariate regression models in this system. Furthermore, the Cm(III) fluorescence peak shape, width, position, and intensity changed significantly as a function of HNO 3 concentration, likely because of the displacement of emission quenching inner-sphere water molecules and complexation with nitrate ions. Despite significant covariance and nonlinearity in the data, a D-optimal design strategy successfully minimized training set sample size and was used to build effective partial least squares regression models for Cm(III) and HNO 3 concentrations without a priori knowledge of solution conditions. Chemometrics for modeling complex fluorescence spectra are promising and may find widespread applicability for online analysis in numerous chemical systems found in the nuclear field.

Actinide

Polarized fluorescence spectroscopy of O2(+)

Polarized fluorescence measurements involving the A 2Pi(u) - X 2Pi(g) and b 4Sigma(g)(-) - a 4Pi(u) transitions in O2(+) following narrow-band photoexcitation of O2/X 3Sigma(g)(-)/ are reported. The analysis, based on the conventional high-J limit, involves deducing the quadrupole alignment factor from which the relative strengths of degenerate photoexcitation channels responsible for the population distribution in the A 2Pi(u) and b 4Sigma(g)(-) states of O2(+) can be estimated. The measured A-channel polarization exhibits pronounced structure which correlates well with the known positions of Rydberg states, whereas the polarization signal in the b channel has broad and less prominent features. Discrepancies between theoretical and measured results can largely be accounted for by additional configuration mixing and autoionization considerations.

Keller, J. W.

Laser Induced Fluorescence Spectroscopy of Neutral and Ionized Polycyclic Aromatic Hydrocarbons in the Cosmic Simulation Chamber

Polycyclic aromatic hydrocarbon (PAH) molecules are considered the best carriers to account for the ubiquitous infrared emission bands. PAHs have also been proposed as candidates to explain the diffuse interstellar bands (DIBs), a series of absorption features seen on the interstellar extinction curve and are plausible carriers for the extended red emission (ERE), a photoluminescent process associated with a wide variety of interstellar environments. Extensive efforts have been devoted over the past two decades to characterize the physical and chemical properties of PAH molecules and ions in space. Absorption spectra of PAH molecules and ions trapped in solid matrices have been compared to the DIBs. Absorption spectra of several cold, isolated gas-phase PAHs have also been measured under experimental conditions that mimic the interstellar conditions. The purpose of this study is to provide a new dimension to the existing spectroscopic database of neutral and single ionized PAHs that is largely based on absorption spectra by adding emission spectroscopy data. The measurements are based on the laser induced fluorescence (LIF) technique and are performed with the Pulsed Discharge Nozzle (PDN) of the COSmIC laboratory facility at NASA Ames laboratory. The PDN generates a plasma in a free supersonic jet expansion to simulate the physical and the chemical conditions in interstellar environments. We focus, here, on the fluorescence spectra of large neutral PAHs and their cations where there is a lack of fluorescence spectroscopy data. The astronomical implications of the data (e.g., ERE) are examined.

Laboratory

Simulated 'On-Line' Wear Metal Analysis of Lubricating Oils by X-Ray Fluorescence Spectroscopy

The objective of this project was to assess the sensitivity of X-ray Fluorescence Spectroscopy (XFS) for quantitative evaluation of metal particle content in engine oil suspensions and the feasibility of real-time, dynamic wear metal analysis. The study was focused on iron as the majority wear metal component. Variable parameters were: particle size, particle concentration and oil velocity. A commercial XFS spectrometer equipped with interchangeable static/dynamic (flow cell) sample chambers was used. XFS spectra were recorded for solutions of Fe-organometallic standard and for a series of DTE oil suspensions of high purity spherical iron particles of 2g, 4g, and 8g diameter, at concentrations from 5 ppm to 5,000 ppm. Real contaminated oil samples from Langley Air Force Base aircraft engines and NASA Langley Research Center wind tunnels were also analyzed. The experimental data conform the reliability of XFS as the analytical method of choice for this project. Intrinsic inadequacies of the instrument for precise analytic work at low metal concentrations were identified as being related to the particular x-ray beam definition, system geometry, and flow-cell materials selection. This work supports a proposal for the design, construction and testing of a conceptually new, miniature XFS spectrometer with superior performance, dedicated to on-line, real-time monitoring of lubricating oils in operating engines. Innovative design solutions include focalization of the incident x-ray beam, non-metal sample chamber, and miniaturization of the overall assembly. The instrument would contribute to prevention of catastrophic engine failures. A proposal for two-year funding has been presented to NASA Langley Research Center Internal Operation Group (IOG) Management, to continue the effort begun by this summer's project.

Kelliher, Warren C.

Study of x-ray fluorescence spectroscopy from high-energy-density plasmas (Final Report)

The primary objective of this subcontract was to support the development of x-ray fluorescence spectroscopy (XFS) as a diagnostic tool for high-energy-density (HED) plasmas. Several experimental campaigns were completed to develop and benchmark XFS at various plasmas conditions of interest for inertial confinement fusion and HED science. The experimental measurements at the Omega laser facility used x-ray absorption spectroscopy (XAS) to determine the plasma temperature from the shape of the K-edge to benchmark XFS data. During the course of these experiments, it was found that XAS can also constrain ionization from bound-bound absorption features, and it became a primary diagnostic in this study. Several experimental campaigns were conducted at the Omega laser facility to refine XAS and XFS measurements of warm dense copper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Characterizing laser-heated polymer foams with simultaneous x-ray fluorescence spectroscopy and Thomson scattering at the Matter in Extreme Conditions Endstation at LCLS

Understanding the behavior of polymer foams at high energy density conditions is crucial to advance inertial fusion energy research. Here, we present a new experimental platform designed to measure the thermodynamic state of these materials at megabar pressures. At the Matter in Extreme Conditions Endstation of the Linac Coherent Light Source, we heat samples using an optical, high-intensity, femtosecond laser and dynamically probe them with ultra-short, coherent x-ray pulses of high peak brightness. We perform x-ray Thomson scattering measurements in forward and backward scattering geometries to capture both collective and non-collective electron behavior in the sample. Simultaneously, x-ray fluorescence spectroscopy is used to measure the emission from a mid-Z dopant, providing complementary information on the plasma conditions. By combining these techniques, we obtain temporally resolved temperature measurements of the transient warm dense matter states. Our initial experiments designed to benchmark the platform with carbon samples yielded data resolving the ultrafast response to laser heating with sub-picosecond resolution, measuring plasma temperatures exceeding 50 eV. These findings lay the foundation for precision studies of the dynamic evolution of laser-heated polymer foams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Fluorescence Spectroscopy of Gas-phase Polycyclic Aromatic Hydrocarbons

The purpose of this investigation was to produce fluorescence spectra of polycyclic aromatic hydrocarbon (PAH) molecules in the gas-phase for comparison with blue luminescence (BL) emission observed in astrophysical sources Vijh et al. (2004, 2005a,b). The BL occurs roughly from 350 to 450 nm, with a sharp peak near 380 nm. PAHs with three to four rings, e.g. anthracene and pyrene, were found to produce luminescence in the appropriate spectral region, based on existing studies. Relatively few studies of the gas-phase fluorescence of PAHs exist; those that do exist have dealt primarily with the same samples commonly available for purchase such as pyrene and anthracene. In an attempt to understand the chemistry of the nebular environment we also obtained several nitrogen substituted PAHs from our colleagues at NASA Ames. In order to simulate the astrophysical environment we also took spectra by heating the PAHs in a flame. The flame environment counteracts the formation of eximers and permits the spectroscopy of free-flying neutral molecules. Experiments with coal tar demonstrate that fluorescence spectroscopy reveals primarily the presence of the smallest molecules, which are most abundant and which possess the highest fluorescence efficiencies. One gas-phase PAH that seems to fit the BL spectrum most closely is phenanthridine. In view of the results from the spectroscopy of coal tar, a compound containing a mixture of PAHs ranging from small to very large PAH molecules, we can not preclude the presence of larger PAHs in interstellar sources exhibiting BL.

Thomas, J. D.

Argon content of the Martian atmosphere at the Viking 1 landing site - Analysis by X-ray fluorescence spectroscopy

Spectra provided by the Viking 1 X-ray fluorescence spectrometer operating in the calibration mode (without a soil sample in the analysis chamber) were analyzed to determine the argon content of the Martian atmosphere at the landing site. This was found to be less than or equal to 0.15 millibar, or not more than 2% by volume, consistent with data obtained by the entry mass spectrometer and by the mass spectrometer on the lander. It is anticipated that analysis of the K content of surface samples using X-ray fluorescence data will provide information on the evolution of the atmosphere, since most atmospheric argon is apparently produced by decay of K-40.

Clark, B. C.

X-ray Fluorescence Spectroscopy Study of Coating Thickness and Base Metal Composition

For electrical, electronic, and electromechanical (EEE) parts to be approved for space use, they must be able to meet safety standards approved by NASA. A fast, reliable, and precise method is needed to make sure these standards are met. Many EEE parts are coated in gold (Au) and nickel (Ni), and the thickness coating is crucial to a part s performance. A nondestructive method that is efficient in measuring coating thickness is x-ray fluorescence (XRF) spectroscopy. The XRF spectrometer is a machine designed to measure layer thickness and composition of single or multilayered samples. By understanding the limitations in the collection of the data by this method, accurate composition and thickness measurements can be obtained for samples with Au and Ni coatings. To understand the limitations of data found, measurements were taken with the XRF spectrometer and compared to true values of standard reference materials (SRM) that were National Institute of Standards and Technology (NIST) traceable. For every sample, six different parameters were varied to understand measurement error: coating/substrate combination, number of layers, counting interval, collimator size, coating thickness, and test area location. Each measurement was taken in accordance with standards set by the American Society for Testing and Materials (ASTM) International Standard B 568.

Rolin, T. D.

Quantitative photoabsorption and fluorescence spectroscopy of H2S and D2S at 49-240 nm

Photoabsorption and fluorescence cross sections of H2S and D2S were measured in the 49-240 nm region using synchrotron radiation as a light source. Fluorescence from photoexcitation of H2S appears at 49-97 nm, but not in the long wavelength region. Fluorescence spectra were dispersed, and used to identify the emitters to be H2S(+) (A), SH(+)(A), and H(n greater than 2). The fluorescence quantum yield is about 6 percent. Photoexcitation of D2S at 49-96 nm produces fluorescence with a quantum yield of about 5 percent. The emitters are identified from the fluorescence spectra to be D2S(+)(A), SD(+)(A), and D(n greater than 2). The Franck-Condon factors for the SH(+) and SD(+) (A-X) transitions were determined. The SD(A-X) fluorescence was observed from photoexcitation of D2S at 100-151 nm, for which the fluorescence cross section and quantum yield were measured.

Lee, L. C.

Quantitative photoabsorption and fluorescence spectroscopy of benzene, naphthalene, and some derivatives at 106-295 nm

Photoabsorption and fluorescence cross sections of benzene, (o-, m-, p-) xylenes, naphthalene, 1-methylnaphthalene, and 2-ethylnaphthalene in the gas phase are measured at 106-295 nm using synchrotron radiation as a light source. Fluorescences are observed from the photoexcitation of benzene and xylenes at 230-280 nm and from naphthalene and its derivatives at 190-295 nm. The absolute fluorescence cross section is determined by calibration with respect to the emission intensity of the NO(A-X) system, for which the fluorescence quantum yield is equal to 1. To cross-check the current calibration method, the quantum yield of the SO2(C-X) system at 220-230 nm was measured since it is about equal to 1. The current quantum-yield data are compared with previously published values measured by different methods.

Suto, Masako

Fluorescence spectroscopy and thermometry for hypersonic flight research

The present study, which has demonstrated the feasibility of using time-resolved laser-induced fluorescence methods to ascertain boundary layer temperature distributions in real time for hypersonic vehicles in atmospheric flight, employs conventional optics in combination with novel time-resolved spectroscopy. The radiative lifetime and signal intensity involved, both of which are reduced by quenching, are adequate for measurement with state-of-the-art time-resolved fluorescence techniques, except for certain conditions associated with both the highest speeds and the lowest altitudes.

Thompson, B. E.

Laser-induced fluorescence spectroscopy for combustion diagnostics

The types of spectroscopic and collisional measurements that are needed to develop laser-induced fluorescence as a diagnostic technique are discussed, with emphasis placed on combustion measurements. The spectroscopic measurements under collision-free conditions include production of radicals, excitation scan studies, lifetime measurements, and fluorescence scans. The collisional studies discussed here are quenching, energy transfer, and polarization phenomena. The results of recent laboratory experiments are presented.

Crosley, D. R.

Diagnostics of Carbon Nanotube Formation in a Laser Produced Plume: An Investigation of the Metal Catalyst by Laser Ablation Atomic Fluorescence Spectroscopy

Carbon nanotubes, elongated molecular tubes with diameters of nanometers and lengths in microns, hold great promise for material science. Hopes for super strong light-weight material to be used in spacecraft design is the driving force behind nanotube work at JSC. The molecular nature of these materials requires the appropriate tools for investigation of their structure, properties, and formation. The mechanism of nanotube formation is of particular interest because it may hold keys to controlling the formation of different types of nanotubes and allow them to be produced in much greater quantities at less cost than is currently available. This summer's work involved the interpretation of data taken last summer and analyzed over the academic year. The work involved diagnostic studies of carbon nanotube formation processes occurring in a laser-produced plume. Laser ablation of metal doped graphite to produce a plasma plume in which carbon nanotubes self assemble is one method of making carbon nanotube. The laser ablation method is amenable to applying the techniques of laser spectroscopy, a powerful tool for probing the energies and dynamics of atomic and molecular species. The experimental work performed last summer involved probing one of the metal catalysts, nickel, by laser induced fluorescence. The nickel atom was studied as a function of oven temperature, probe laser wavelength, time after ablation, and position in the laser produced plume. This data along with previously obtained data on carbon was analyzed over the academic year. Interpretations of the data were developed this summer along with discussions of future work. The temperature of the oven in which the target is ablated greatly influences the amount of material ablated and the propagation of the plume. The ablation conditions and the time scale of atomic and molecular lifetimes suggest that initial ablation of the metal doped carbon target results in atomic and small molecular species. The metal atoms survive for several milliseconds while the gaseous carbon atoms and small molecules nucleate more rapidly. Additional experiments and the development of in situ methods for carbon nanotube detection would allow these results to be interpreted from the perspective of carbon nanotube formation.

deBoer, Gary