Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fluid flow measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Electromagnetic probe technique for fluid flow measurements

The probes described herein, in various configurations, permit the measurement of the volume fraction of two or more fluids flowing through a pipe. Each probe measures the instantaneous relative dielectric constant of the fluid in immediate proximity. As long as separation of the relative dielectric constant of the fluid is possible, several or even many fluids can be measured in the same flow stream. By using multiple probes, the velocity of each fluid can generally be determined as well as the distribution of each constituent in the pipe. The values are determined by statistical computation. There are many potential applications for probes of this type in industry and government. Possible NASA applications include measurements of helium/hydrazine flow during rocket tests at White Sands, liquid/gas flow in hydrogen or oxygen lines in Orbiter engines, and liquid/gaseous Freon flow in zero gravity tests with the KS135 aircraft at JSC. Much interest has been shown recently by the oil industry. In this a good method is needed to measure the fractions of oil, water, and natural gas flowing in a pipeline and the velocity of each. This particular problem involves an extension of what has been developed to date and our plans to solve this problem will be discussed herein.

Arndt, G. D.↗

Electromagnetic Probe Technique for Fluid Flow Measurements

The probes described herein, in various configurations, permit the measurement of the volume fraction of two or more fluids flowing through a pipe. Each probe measures the instantaneous relative dielectric constant of the fluid in immediate proximity. As long as separation of the relative dielectric constants of each fluid is possible, several or even many fluids can be measured in the same flow steam. By using multiple probes, the velocity of each fluid can generally be determined as well as the distribution of each constituent in the pipe. The values are determined by statistical computation. There are many potential applications for probes of this type in industry and government. Possible NASA applications include measurements of helium/hydrazine flow during rocket tests at White Sands, liquid/gas flow in hydrogen or oxygen lines in Orbiter engines, and liquid/gaseous Freon flow in zero gravity tests with the KS135 aircraft at JSC. Much interest has been shown recently by the oil industry. In this industry, a good method is needed to measure the fractions of oil, water, and natural gas flowing in a pipeline and the velocity of each. This particular problem involves an extension of what has been developed to date and our plans and program to solve this problem will be discussed herein.

Arndt, G. D.↗

Method and Apparatus for Measuring Fluid Flow

Method and apparatus for making measurements on fluids related to their complex permeability are disclosed. A microwave probe is provided for exposure to the fluids. The probe can be non-intrusive or can also be positioned at the location where measurements are to be made. The impedance of the probe is determined. in part. by the complex dielectric constant of the fluids at the probe. A radio frequency signal is transmitted to the probe and the reflected signal is phase and amplitude detected at a rapid rate for the purpose of identifying the fluids. Multiple probes may be selectively positioned to monitor the behavior of the fluids including their flow rate. Fluids may be identified as between two or more different fluids as well as multiple phases of the same fluid based on differences between their complex permittivities.

Arndt, G. Dickey↗

Method and Apparatus for Measuring Fluid Flow

The invention is a method and apparatus for monitoring the presence, concentration, and the movement of fluids. It is based on utilizing electromagnetic measurements of the complex permittivity of the fluids for detecting and monitoring the fluid. More particularly the apparatus uses one or more microwave probes which are placed at the locations where the measurements are to be made. A radio frequency signal is transmitted to the probe and the reflected signal is phase and amplitude detected at a rapid rate for the purpose of identifying the fluids, based on their dielectric constant at the probe. The apparatus can be used for multiple purposes including measures of flow rates, turbulence, dispersion, fluid identification, and changes in flow conditions of multiple fluids or multiple states of a single fluid in a flowline or a holding container. The apparatus includes a probe consisting of two electrical conductors separated by an insulator. A radio frequency signal is communicated to the probe and is reflected back from the portion of the probe exposed to the fluid. The radio frequency signal also provides a reference signal. An oscillator generates a second signal which combined with each of the reference signal and the reflected signal to produce signals of lower frequencies to facilitate filtering and amplifying those signals. The two signals are then mixed in a detector to produce an output signal that is representative of the phase and amplitude change caused by the reflection of the signal at the probe exposed to the fluid. The detector may be a dual phase detector that provides two such output signals that are in phase quadrature. A phase shifter may be provided for selectively changing the phase of the reference signal to improve the sensitivity of at least one of the output signals for more accurate readings and/or for calibration purposes. The two outputs that are in quadrature with respect to each other may be simultaneously monitored to account for drift errors. The output signals are digitized and provided to a computer at a sample rate which may be very high. The computer is operable to identify the fluid based on its complex permittivity as may be useful for identifying the flow rates, determining the fluid mixture ratio, detecting impurities in the fluid, and so forth. Novelty is believed to reside in the use of the real part of complex permittivity to measure small difference in permittivity of the fluid.

Arndt, G. Dickey↗

Analytical solution for partial heating on the exterior of the pipe with application to measuring fluid flow rate

An analytical model using Green’s functions for partial external heating of a pipe is developed, which results in an exact mathematical solution for the radial and axial temperature distribution in the pipe wall. Partial heating consists of a constant heat flux function imposed over a small section of the exterior of a pipe and for a limited time duration. The solution comprises steady-state and transient parts, and an algebraic identity is used to decrease the number of summation terms in the slowly-converging steady- state part. Intrinsic verification principles are used to verify the solution. As an example application, this transient solution is applied toward the development of a simple, noninvasive method for in-field measurement of the flow rate in pipes. Furthermore, to simulate this application, a pulse of energy is imposed to the wall of the pipe, and the developed mathematical solution is used to find the flow rate of the fluid inside the pipe. An optimal experiment is designed to find the best measurement location and time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measured Fluid Flow in an Active H2O-CO2 Geothermal Well as an Analog to Fluid Flow in Fractures on Mars: Preliminary Report

Water in the Earth's crust generally contains dissolved gases such as CO2. Models for both 'Blue Mars' (H2O-driven processes) and 'White Mars' (CO2-driven processes) predict liquid H2O with dissolved CO2 at depth. The fate of dissolved CO2 as this mixture rises toward the surface has not been quantitatively explored. Our approach is a variation on NASA's 'Follow the Water' as we 'Follow the Fluid' from depth to the surface in hydrothermal areas on Earth and extrapolate our results to Mars. This is a preliminary report on a field study of fluid flow in a producing geothermal well. For proprietary reasons, the name and location of this well cannot be revealed, so we have named it 'Earth1' for this study.

Kieffer, Susan W.↗

In-situ thermal transport measurement of flowing fluid using modulated photothermal radiometry

In situ thermal transport measurement of flowing fluid could be useful for the characterization and diagnosis of practical thermal systems such as fluid heat exchangers and thermal energy storage systems. Despite abundant reports on the ex-situ thermal conductivity measurement of stagnant fluids, a suitable technique for the thermal conductivity measurement of flowing fluid has been rarely reported. Here, this paper presents the thermal conductivity measurement of flowing fluid within a pipe using a non-contact modulated photothermal radiometry (MPR) technique, where the surface of the pipe is heated by an intensity-modulated laser and the heat diffuses into the fluid with suitable modulation frequency. We design a tube section with small wall thickness suitable for the MPR measurements to maximize the sensitivity of the thermal response to the fluid properties while minimizing the lateral heat spreading effect. Intrinsic thermal conductivity of different fluids was obtained within a proper range of frequency and flow velocity where the forced convection effect is negligible. The forced convection effect became prominent at high flowing velocity and at low modulation frequency, leading to higher effective thermal conductivity of the fluid. It is found that the intrinsic thermal conductivity could be obtained when the flow velocity is less than 100 mm/sec and Re D 1/2 Pr 1/3 < 100 for DI water and Xceltherm oil under the specified experimental conditions, where Re D is the Reynolds number and Pr is the Prandtl number.

42 ENGINEERING↗

Fluid flow meter for measuring the rate of fluid flow in a conduit

A tube fluid flow rate meter consists of a reservoir divided by flexible diaphragm into two separate isolated compartments. The incoming and outgoing tubes open into the compartments. The orifice is sized to allow maximum tube fluid flow. Opposing compression springs are secured within the two compartments on opposite sides of the orifice to maintain orifice position when the tube fluid pressure is zero. A tapered element is centered in, and extends through the orifice into the compartment, leaving an annular opening between the element and the perimeter of the oriface. The size varies as the diaphragm flexes with changes in the tube fluid pressure to change the fluid flow through the opening. The light source directs light upon the element which in turn scatters the light through the opening into the compartment. The light detector in the compartment senses the scattered light to generate a signal indicating the amount of fluid.

White, P. R.↗

Measurement of two-dimensional fluid flow by digital correlation of scattered light

Digital correlation is a pattern matching procedure. This procedure has recently been used in two-dimensional fluid flow measurements. Two images of a seeded fluid are taken and the intensity distribution of a small window in the first image is matched in the second image using a statistical correlation method. A series of structure functions have been implemented to improve the accuracy and reliability of the correlation method and new algorithms have been developed to reduce the time required for the correlation computations.

Matthys, Donald R.↗

Fluid flow volume measurements using a capacitance/conductance probe system

A probe system has been developed to measure the flow volume of a single fluid passing through an orifice or flow line. The system employs both capacitance and a conductance probe at the orifice, together with phase detection and data acquisition circuitry to measure flow volume and salinity under low or zero gravity conditions. A wide variety of frequencies can be used for the radio frequency (RF) signal source which is chosen primarily by the capacitance of the orifice probe and the fluid passing through the orifice. Rapid measurements are made using the reflected signal from the orifice probe to determine the 'instantaneous' permittivity of the fluid/gas mixture passing through. The 'instantaneous' measurements are integrated over time to determine flow volume. Analysis reveals that a narrow orifice helps to reduce non-linearities caused by differing flow rates. The geometry of 'deflectors' and 'directors' for the flowing fluid are important in obtaining linearity. Measured data shows that a volume measurement accuracy of approximately four percent can be consistently achieved. The prototype hardware system and associated software have been optimized and are available for further applications. The system has immediate application in low or zero gravity environments for measurements of urine or other liquid volumes.

Nguyen, T. X.↗

Instrument continuously measures density of flowing fluids

Electromechanical densitometer continuously measures the densities of either single-phase or two-phase flowing cryogenic fluids. Measurement is made on actual flow. The instrument operates on the principle that the mass of any vibrating system is a primary factor in determining the dynamic characteristics of the system.

Jacobs, R. B.↗

Flow measurement. II.

Cryogenic fluid mass flow measurement methods, noting flow meter calibration

FLOW MEASUREMENT↗

Experimental measurements of fluid flow in an 84-pin hexagonal rod bundle with spacer grid for a gas-cooled fast modular reactor

A 50 MW e helium-cooled fast modular reactor (FMR) is under development, and as part of the Department of Energy Integrated Research Project (IRP), Texas A&M University is conducting the thermal-hydraulic characterization of its baseline core configuration. Here, we experimentally investigated the axial and cross flow fields characteristics in the hexagonal fuel rod bundle composed of 84 rods, a central rod, and spacer grids at a Reynolds number of 12,000. A fully transparent experimental facility resembling of one unit of the fuel assembly was constructed. Time-resolved particle image velocimetry (TR-PIV) measurements were performed to characterize hydraulic behavior downstream the spacer grid. Velocity measurements were conducted in the axial and radial direction of the rod bundle. From the PIV velocity vector fields, the full-field flow statistics were computed for the mean velocity, vorticity, and Reynolds stresses. An analysis of the energy decay downstream of the spacer grid was conducted with calculations of secondary-flow intensities, turbulent kinetic energy, power spectrum, and spatial-temporal velocity cross correlations. The vorticity field was obtained and pairs of counter-rotating vortexes were identified using a 3D reconstruction of several measurement planes. The data from this experimental campaign will be used to validate numerical models based on Computational Fluid Dynamics and other codes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development and calibration of buried wire gages for wall shear stress measurements in fluid flow

Special methods were developed to arrange 'Buried Wire Gage' inserts flush to the contoured flow surfaces of instrument plugs of a boundary-layer flow apparatus. The fabrication process was aimed at producing proper bonding of the sensor wire to the substrate surface, without causing excessive surface waviness. A large number of gages were built and first calibrated for the resistance-temperature characteristics. The gages were then installed in a flow calibration apparatus and operated from a constant temperature anemometer system for a series of flow settings to derive the calibration constants of each of the gages. The flow settings included a range of subsonic freestream Mach numbers in order to help establish the gage calibration characteristics for compressible flow fields. This paper provides a description of the buried wire gage technique, an explanation of the method evolved for making proper gages, the procedure for calibrating the gages and the results of measurements performed for determining the calibration constants.

Murthy, Sreedhara V.↗

Generating aerosols for laser velocimeter seeding

The laser velocimeter (LV) is a unique tool for fluid flow measurements. In such measurements, even though the fluid velocity is of primary interest, the LV signal originates from seed particles present in the fluid and the LV actually measures the velocity of these particles. Thus it is important that a sufficient number of seed particles be present in the fluid and they scatter sufficient light to produce LV signals. Also, the seed particles should follow the fluid with high fidelity. Aerodynamic diameter is the true measure of a particle's ability to follow the flow. The aerodynamic diameter of a particle is defined as the diameter of a unit density sphere with same settling velocity as the particle in question. It is affected by geometric diameter, density and shape of the particle. For LV seeding, particles with smaller aerodynamic diameter are desirable because they follow the flow more readily. On the other hand, in general, the particle's ability to scatter light increases with its geometric diameter and its refractive index.

Agarwal, J. K.↗