Biphasic solvents for post-combustion CO 2 capture from natural gas flue Gas

Fossil fuel fired power plants are generally expected to remain one of the most significant global sources of electricity for decades to come. Consequently, carbon management technologies are needed to reduce or eliminate ongoing emissions from these sources. Amongst the many techniques for carbon capture, aqueous amine-based absorbents (monoethanolamine, MEA, in particular) are, presently, considered the leading technology for post-combustion CO 2 point-source capture. These technologies are nevertheless limited by their high capital and regeneration energy costs. Biphasic solvents have been identified as an attractive alternative to traditional MEA based absorbents due to their potential energy savings. Thus far, however, the research on biphasic solvents has largely focused on their performance in coal flue gas while more dilute natural gas flue gas applications have received relatively little attention. Here, this work examines the performances of two novel biphasic solvent blends, diethylenetriamine (DETA) and triethylenetetramine (TETA), in CO 2 capture from a natural gas flue gas simulant. Across several regeneration tests, both solvents achieved considerable energy savings over the benchmark MEA solution. Specifically, the energy consumption per mol CO 2 recovered for the DETA-based and TETA-based solvents was 46 % and 35 % less than that of the benchmark MEA solution, respectively. Molecular dynamics simulations were also performed to gain a deeper understanding of the phase separation phenomena that occur as a consequence of CO 2 absorption. These simulations indicated that phase change was driven by the strong interaction between the absorption products and water, while the degree of separation depended on the CO 2 loading.

Biphasic solvents↗

Direct, efficient and selective capture of low concentration of CO 2 from natural gas flue gas using a high temperature tubular carbon capture membrane

Natural gas (NG) fired power plants emit low concentration (4–5%) of CO 2 , which presents additional technical and economic challenges to the current benchmark amine absorption technology. The newly emerged high-temperature multiphase membranes operated on molten carbonate (MC) chemistry for CO 2 capture/separation/conversion have been demonstrated with great potential to meet this challenge. In this study, we report on the CO 2 capture performance of such a membrane in tubular geometry from a mockup NG flue gas. The membrane is comprised of a mixture of Gd 0.20 Ce 0.80 O 1.95 (GDC) and MC, in which GDC forms a porous skeleton to contain MC. Here, we show that the membrane with a dimension of 6.1 mm in outer diameter, 5.1 mm in inner diameter and 5 cm in effective length (resulting in 4cm 2 effective surface area) can achieve a CO 2 flux density of 0.46–0.55 mL/min·cm 2 at 650°C, capturing 97% pure CO 2 at a rate of 37–42% from 5%CO 2 –N 2 using moistened Ar as the sweep gas. The level of performance demonstrated by this study suites the membrane well for stationary CO 2 capture from NG power plants.

03 NATURAL GAS↗

Transformational Nano-confined Ionic Liquid Membrane for Greater than or Equal to 97 Percent Carbon Dioxide Capture from Natural Gas Combined Cycle Flue Gas

A transformational process based on nano-confined ionic liquid (NCIL) membranes was developed for capturing ≥97% CO 2 from natural gas combined cycle (NCCC) flue gas. The NCIL membranes were prepared by loading amino acid ionic liquid into a framework composed of single-walled carbon nanotube mesh filled with graphene oxide quantum dots. The membranes exhibited CO 2 permeance as high as 2,000 GPU with a CO 2 /N2 selectivity of 2,300 for a typical NGCC flue gas composition. When H 2 O vapor sweep was applied in the permeate side, 96.6% CO2 dry-basis purity and 97.6% CO 2 capture rate were achieved for a simulated NGCC flue gas with single stage. In the process design, a highly H 2 O-selective membrane would be needed to recover majority of the H 2 O vapor, and the recovered H 2 O vapor could be recycled to the permeate side of the NCIL membrane. Sulfonated poly(ether ether ketone) membranes were successfully developed for this purpose. These membranes exhibited H 2 O permeance great than 11,000 GPU and H 2 O/CO 2 selectivity greater than 1,000 at 70ºC for a feed mixture consisting of 14.5 vol% H2O and balanced CO 2 . A standalone membrane model using MATLAB platform was developed for process simulation. The model was validated with experimental data. Techno-economic analysis based on the testing data collected during the current program suggests this transformational membrane process can achieve 97% CO 2 capture efficiency with a cost of $47.8/tonne of CO 2 , which is a 21% reduction versus DOE’s reference case B31B.97.

03 NATURAL GAS↗

Flue Gas Desulfurization Wastewater Composition and Implications for Regulatory and Treatment Train Design

The U.S. Environmental Protection Agency is currently revising its regulations on trace element discharges from flue gas desulfurization (FGD) wastewater.<br>In this work, we expand a predictive model of trace element behavior at coal-fired power plants (CFPPs) to estimate the trace element concentration of FGD wastewater at the plant level. We demonstrate that variation in trace element concentrations in FGD wastewater can span several orders of magnitude and is a function of both coal rank and installed air pollution control devices. This conclusion suggests that the benefits and costs of FGD wastewater treatment for the median plant will poorly describe the actual benefits and costs over the full range of existing CFPPs.

Mauter, Meagan↗

Recent Progress in the Engineering of Polymeric Membranes for CO2 Capture from Flue Gas

CO2 capture from coal- or natural gas-derived flue gas has been widely considered as the next opportunity for the large-scale deployment of gas separation membranes. Despite the tremendous progress made in the synthesis of polymeric membranes with high CO2/N2 separation performance, only a few membrane technologies were advanced to the bench-scale study or above from a highly idealized laboratory setting. Therefore, the recent progress in polymeric membranes is reviewed in the perspectives of capture system energetics, process synthesis, membrane scale-up, modular fabrication, and field tests. These engineering considerations can provide a holistic approach to better guide membrane research and accelerate the commercialization of gas separation membranes for post-combustion carbon capture.

20 FOSSIL-FUELED POWER PLANTS↗

In-situ measurement of moist flue gas under high pressure using a nafion dryer and FTIR

The formation of the main flue gas species (NOx, SOx, CO2, and CO) in pressurized oxy-fuel combustion can be fundamentally different from oxy-fuel combustion at atmospheric pressure. To accurately obtain the concentration of these gas species in a pressurized oxy-fuel combustor, a gas measurement which maintains the sampling pressure is needed. Very few published studies have accomplished this, and never under the conditions reported herein. In this work, we fire PRB coal in a 100 kWth staged pressurized oxy-fuel combustor (SPOC) under a pressure 15 bara. We utilize a state-of-the-art FTIR (Thermo Scientific Nicolet iS20) with a novel high-pressure gas cell that is under process pressure to measure the in-situ flue-gas concentration in a sampled flow. However, water vapor can significantly interfere with the FTIR measurement, particularly under pressure. To address this problem, we have developed a high-pressure nafion dryer to selectively remove the water vapor from the flue gas while retaining the flue gas species. This approach can significantly increase the signal-noise ratio for the FTIR. By integrating the nafion dryer and the high-pressure gas cell, we were able to successfully measure flue gas species at system pressure with the FTIR.

Cheng, Mao↗

A direct contact cooler design for simultaneously recovering latent heat and capturing SO x and NO x from pressurized flue gas

Integrated SO x and NO x removal technology using a direct contact cooler is a promising alternative for cleaning coal combustion flue gas, especially for pressurized combustion systems. Past investigations of integrated SO x and NO x removal have been limited to low-temperature processes, where the flue gas has been cooled upstream of the removal unit, and the moisture in the flue gas has been condensed out. Here this work presents a novel design that recovers the flue gas heat while simultaneously removing SO x and NO x in a single reactive-absorption column – direct contact cooler. A validated model was used to evaluate different direct contact cooler designs. Modeling results suggested that a counter-current column with a single water inlet can scrub 83% of the NO x and 96.5% of the SO x in 115 s, while an optimized design with multiple water inlets enhances the scrubbing of NO x by 9 percentage points and SO x by 3.5 percentage points, due to a 34% increase in residence time. It is also observed that the liquid-phase reaction between absorbed SO x and NO x plays a significant role in the removal of SO 2 from the flue gas for high-temperature scrubbing compared with low-temperature scrubbing. The design reinforces the potential of high-temperature SO x -NO x removal and heat recovery and suggests a means of reducing capital costs for such columns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiscale modeling and nonlinear model predictive control for flue gas desulfurization

The primary source of sulfur dioxide (SO 2 ) emissions is flue gas from fossil fuels-based power plants. SO 2 emissions are known to not only cause health issues, but also have an adverse effect on the environment in various ways. Several Flue Gas Desulfurization (FGD) technologies have been incorporated in power plants. The most popular technology is Wet FGD, where a limestone slurry is used to absorb SO 2 from the flue gas. A detailed droplet scale model describing the instantaneous and finite rate chemistry is developed. The ill-posed Differential-Algebraic Equation (DAE) droplet model is reformulated to a well-posed index-1 DAE through index reduction. The droplet model is integrated with the bulk phase by incorporating gas-liquid mass transfer, and an oxidation reactor model to simulate the dynamic operation of the counter-current spray scrubber. As a result, the model has a well-conditioned Jacobian and overcomes the modeling challenges of previous works and enables numerical solution without requiring carefully selected initialization or specialized solution procedures. The model is successfully validated using power plant measurements, and nonlinear model predictive control (NMPC) studies are demonstrated to optimize recycle stream flowrates to minimize pumping costs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Catalytic Removal of Oxygen Impurities from Pressurized Oxy-Combustion Flue Gas for the Production of High-Purity Carbon Dioxide

Flue gas purification is important for pressurized oxy-combustion systems to produce pure carbon dioxide (CO 2 ) streams ready for storage or utilization. A catalytic approach to removing oxygen (O 2 ) impurities from pressurized oxy-combustion flue gas via reduction with methane (CH 4 ) was investigated in this work. Two types of catalysts were studied: palladium (Pd)-based catalysts supported on titania (TiO 2 ) prepared by incipient wetness impregnation and cobalt–manganese (CoMn) composite catalysts prepared by coprecipitation. The performance of the catalysts was evaluated in a high-pressure–high-temperature, fixed-bed reactor at a pressure of 15 bar and a gas hourly space velocity of 30 000 h –1 (standard conditions), with a simulated feeding gas composed of 3 vol % O 2 , 1.5 vol % CH 4 , and CO 2 as the balance gas. Among the Pd catalysts, 5% Pd/TiO 2 achieved the maximum 86% O 2 removal at ≥350 °C. The CoMn oxide catalysts displayed comparable or better activities for O 2 reduction compared with the Pd catalysts. Among them, the Co 40 Mn 1 catalyst exhibited the best performance, able to reduce 99.9% of O 2 impurities at ~370 °C with negligible carbon monoxide (CO) formation (<10 ppmv). Both trivalent and divalent Co and Mn were detected on the catalyst surface, and the superior activity of Co 40 Mn 1 might be associated with the resultant disordered structure. Furthermore, the activity of the catalyst was not affected by the presence of a trace amount of nitric oxide (NO) gas contaminant. Results of this study provide the basis for scale-up studies in both the synthesis and performance of non-noble metal catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Creating an Advanced Sensor Network to calculate real-time, mass-weighted flue gas composition and air heater leakage of a coal-fired utility boiler under dynamic operating conditions

Utilization of renewable energy sources to minimize the environmental impact of energy production has changed the way utility boilers operate, requiring frequent load cycling between full load and partial loads as low as 30%. Dynamic operation of coal-fired utility boilers significantly reduces boiler efficiency when compared to steady state at full load. Data-driven plant optimization has shown success with coal-fired utility boilers under dynamic operating conditions. The purpose of this work was to create an Advanced Sensor Network (ASN) to provide more extensive real-time data to inform dynamic plant optimization of Net Unit Heat Rate (NUHR). The ASN consists of gas sampling grids in the convective pass of the boiler and downstream of the air heater. These sampling grids allow for quantification of spatial variation of flue gas within the boiler and calculation of mass-weighted composition of flue gas through the combination of composition, velocity, and temperature measurements. The comparison of O 2 between the inlet and outlet of the air heater is used to calculate air leakage in real time. Flue gas composition and air heater leakage are both important factors in boiler efficiency and NUHR. Further, the results of this work support the value of mass-weighted averages for determining flue gas composition accurately. The measurements from the ASN show increased composition stratification during dynamic operation, with an average standard deviation 38% higher than observed during steady-state operation. Air heater leakage was also observed to increase from 2.8% to 5.1% following a load change. Prior to the installation of the ASN, these data would not have been available for dynamic control. These real-time data will be leveraged to calculate and optimize for NUHR during dynamic operation in future work.

42 ENGINEERING↗

Novel Transformational Membranes and Process for CO 2 Capture from Flue Gas (FE0031731)

The objectives of this project are to develop a cost-effective design and fabrication process for a novel transformational membrane and its membrane modules that capture CO 2 from flue gas. Optimization of the novel transformational membrane, scale-up of the membrane to a prototype size of about 20" wide in continuous roll-to-roll fabrication, and construction and testing of a skid for the integrated membrane process will be performed. For the design of this membrane, we use a cost-effective polymer support and coat a thin top layer of the membrane. The simplicity of this membrane design offers a low cost for the membrane element in commercial spiral-wound (SW) configuration (<$2.00/ft 2 or $21.5/m 2 ). The prototype membrane will be used to fabricate 6 pilot-size membrane modules (each about 20" length, 3 modules each at the commercial-size diameter of 8 inches with 35 m 2 membrane area for Stage 1 and 3 modules each at 5-inch diameter with 12 m 2 membrane area for Stage 2) for testing with simulated flue gas at OSU and with actual flue gas at the National Carbon Capture Center, Wilsonville, AL using the skid to capture the CO 2 (at 60 – 90%) with at least 95% CO 2 purity. The prototype membrane modules will be in commercial SW configuration with a minimal pressure drop (<0.103 bar/meter (1.5 psi/meter)). These objectives have been achieved successfully.

20 FOSSIL-FUELED POWER PLANTS↗

High Performance Solvent for NGCC Flue Gas CO 2 Capture (Final Technical Report)

Amine-based solvent absorption is the most mature and reliable technology for large scale CO 2 capture, dating back to the 1930s when monoethanolamine (MEA) was used to treat acid gases from oil refineries. However, while strategic advancements have optimized the CO2 capture process, the cost of capture remains high, where current estimates suggest that CO 2 capture costs are around $\$$72/tonne of CO 2 . To address this, solvent development and optimization have become a focus of current research. This project sought to develop a high-performance solvent to reduce the overall cost of CO 2 capture from NGCC flue gas. Here, solvent optimization focused on: (1) reducing the energy required for CO 2 desorption in a reboiler, (2) improving CO 2 absorption and desorption reaction kinetics, (3) improving solvent stability, and (4) reducing environmental impacts. Susteon has developed and evaluated a promoted solvent, Sustenol™, for NGCC flue gas CO 2 capture. The optimized Sustenol™ also shows a higher dynamic CO 2 absorption capacity of ~0.5 mol CO2 /mol amine compared to 0.25 mol CO2 /mol amine for 30 wt% MEA. Additionally, the solvent is oxidatively, thermally and hydrothermally stable, which leads to lower solvent loss and emissions. These advancements have resulted in a solvent regeneration energy of 2.16 GJ/tonne of CO 2 which is >30% lower than current state-of-the-art commercial and emerging solvents. Combined with empirical data from the bench and pilot scale testing, this preliminary TEA study indicated the cost of CO 2 capture by Sustenol™ for 97% CO 2 removal at $\$$54/tonne and for 90% removal at $\$$49/tonne, with a pathway to achieve $\$$45/tonne of CO 2 with continued process and solvent advancements. Susteon has developed a technology roadmap to reduce the cost of CO 2 capture to <$\$$45/tonne for NGCC flue gas. Susteon plans to derisk this technology for commercial deployment through comprehensive solvent degradation testing, long-term testing in a pilot plant at 5 tonne CO2 /day and demonstration scale testing at 100 tonne CO2 /day with NGCC flue gas and engineering design studies to qualify Sustenol™ as a drop-in replacement solvent.

03 NATURAL GAS↗

CO 2 capture from wet flue gas using a water-stable and cost-effective metal-organic framework

We report the use of MIL-120 as a water-stable and cost-effective metal-organic framework (MOF) for selectively capturing CO 2 from wet flue gas. Synthesized using inexpensive and environmentally benign reagents in water, MIL-120 possesses one-dimensional pores decorated with hydroxyl-bridged Al(III) ions and benzene rings with an interstitial spacing of 4.78 Å. Carbon dioxide isotherms show steep uptake at low pressure, and the affinity of MIL-120 for CO 2 is 44 kJ mol –1 . CO 2 -loading 13 C solid-state nuclear magnetic resonance and Fourier transform infrared spectra tracking the sorption of CO 2 into MIL-120 revealed that the interplay of pore size, functionality, and dimensionality is vital for CO 2 restriction within the pores of MIL-120. Breakthrough experiments reveal that MIL-120 can capture CO 2 from dry and wet flue gas with uptake capacities of 1.215 and 1.118 mmol g –1 , respectively. Our work highlights the synthetic benefits of MIL-120 and elucidates its selective capture of CO 2 from wet flue gas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effective removal of trace-level toxic metals from flue gas desulfurization wastewater using SiO 2 supported hydrogel sorbent

Flue gas desulfurization (FGD) wastewater generated from coal-fired power plants contain potentially harmful heavy metal pollutants that pose a threat to public health and clean water. In this work, we present a water stable polyethylenimine-n,n’-methylenebisacrylamide (PEI-MBAA) functionalized SiO 2 solid sorbent material (PMS-1.2/1/4) and investigate its metal adsorption kinetics, selectivity, regenerability, and space velocity. The kinetic studies of six of the toxic heavy metals (As, Cd, Cr, Pb, Se, and Hg) prepared with single elements in Milli-Q water showed the effect of chemical bonding and intraparticle mass transfer resistance on the sorption process. The selectivity studies demonstrated the significant adsorption efficiency toward trace-level heavy metals (Se, Cd, U, Al, etc.) from authentic industrial FGD wastewater. Through five consecutive adsorption–desorption cycles with the FGD (uptake)-citrate (release)-based buffer pair, the sorbent showed high heavy metal removal ability and good reusability. The maximum flow rate for the removal of Se from industrial FGD wastewater was determined to be as high as 8 bed volumes/minute of the sorbent bed. Finally, the results demonstrate the PMS-1.2/1.4 sorbent is a promising candidate for the removal of heavy metals from practical aqueous solutions.