Engineering PapersSearch

SEARCH · Engineering Papers

Results for “floating array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation of Vertical Patterns in Chlorophyll-A Derived From A Data Assimilating Model of Satellite-Based Ocean Color

Satellite-based sensors of ocean color have become the primary tool to infer changes in surface chlorophyll, while BGC-Argo floats are now filling the information gap at depth. Here we use BGC-Argo data to assess depth-resolved information on chlorophyll-a derived from an ocean biogeochemical model constrained by the assimilation of surface ocean color remote sensing. The data-assimilating model replicates well the general seasonality and meridional gradients in surface and depth-resolved chlorophyll-a inferred from the float array in the Southern Ocean. On average, the model tends to overestimate float-based chlorophyll, particularly at times and locations of high productivity such as the beginning of the spring bloom, subtropical deep chlorophyll maxima, and non-iron limited regions of the Southern Ocean. The highest model RMSE in the upper 50 m with respect to the float array is of 0.6 mg Chl m −3 , which should allow the detection of seasonal changes in float-based biomass (varying between 0.01 and >1 mg Chl m −3 ) but might hinder the identification of subtle changes in chlorophyll at narrow local scales. Both model and float profiling data show good agreement with in situ data from station ALOHA, with model estimates showing a slight accuracy edge in inferring depth-resolved observations. Uncertainties in float bio-optical estimates impede their use as a reliable benchmark for validation, but the general qualitative agreement between model and float data provides confidence in the ability of model to replicate biogeochemical features below the surface, where data is not directly constrained by the assimilation of satellite ocean color.

Lionel A Quintero

LEO high voltage solar array arcing response model

A series of mathematical models were developed that describe the electrical behavior of a large solar cell array floating electrically in the low Earth orbit (LEO) space plasma and struck by an arc at a point of negative bias. There are now three models in this series: ARCII, which is a fully analytical, linearized model; ARCIII, which is an extension of ARCIII that includes solar cell inductance as well as load reactance; Nonlinear ARC, which is a numerical model able to treat effects such as non-linearized, i.e., logarithmic solar cell I/V characteristics, conductance switching as a solar cell crosses plasma ground on a voltage excursion and non-ohmic plasma leakage current collection.

Metz, Roger N.

A Numerical Climate Observing Network Design Study

This project was concerned with three related questions of an optimal design of a climate observing system: 1. The spatial sampling characteristics required from an ARGO system. 2. The degree to which surface observations from ARGO can be used to calibrate and test satellite remote sensing observations of sea surface salinity (SSS) as it is anticipated now. 3. The more general design of an climate observing system as it is required in the near future for CLIVAR in the Atlantic. An important question in implementing an observing system is that of the sampling density required to observe climate-related variations in the ocean. For that purpose this project was concerned with the sampling requirements for the ARGO float system, but investigated also other elements of a climate observing system. As part of this project we studied the horizontal and vertical sampling characteristics of a global ARGO system which is required to make it fully complementary to altimeter data with the goal to capture climate related variations on large spatial scales (less thanAttachment: 1000 km). We addressed this question in the framework of a numerical model study in the North Atlantic with an 1/6 horizontal resolution. The advantage of a numerical design study is the knowledge of the full model state. Sampled by a synthetic float array, model results will therefore allow to test and improve existing deployment strategies with the goal to make the system as optimal and cost-efficient as possible. Attachment: "Optimal observations for variational data assimilation".

Stammer, Detlef

Earth Radiation Imbalance from a Constellation of 66 Iridium Satellites: Climate Science Aspects

The "global warming hiatus" since the 1998 El Nino, highlighted by Meehl et al., and the resulting "missing energy" problem highlighted by Trenberth et al., has opened the door to a more fundamental view of climate change than mere surface air temperature. That new view is based on two variables which are strongly correlated: the rate of change of ocean heat content d(OHC)/dt; and Earth Radiation Imbalance (ERI) at the top of the atmosphere, whose guesstimated range is 0.4 to 0.9 Watts per square meters (this imbalance being mainly due to increasing CO2). The Argo float array is making better and better measurements of OHC. But existing satellite systems cannot measure ERI to even one significant digit. So, climate model predictions of ERI are used in place of real measurements of it, and the satellite data are tuned to the climate model predictions. Some oceanographers say "just depend on Argo for understanding the global warming hiatus and the missing energy", but we don't think this is a good idea because d(OHC)/dt and ERI have different time scales and are never perfectly correlated. We think the ERB community needs to step up to measuring ERI correctly, just as oceanographers have deployed Argo to measure OHC correctly. This talk will overview a proposed constellation of 66 Earth radiation budget instruments, hosted on Iridium satellites, that will actually be able to measure ERI to at least one significant digit, thus enabling a crucial test of climate models. This constellation will also be able to provide ERI at two-hourly time scales and 500-km spatial scales without extrapolations from uncalibrated narrowband geostationary instruments, using the highly successful methods of GRACE to obtain spatial resolution. This high time resolution would make ERI a synoptic variable like temperature, and allow studies of ERI's response to fast-evolving phenomena like dust storms and hurricanes and even brief excursions of Total Solar Irradiance. Time permitting, we will also discuss the emerging view of clear vs. cloudy and its implications for the traditional ERB approach.

Wiscombe, W.

Findings of the Joint Workshop on Evaluation of Impacts of Space Station Freedom Ground Configurations

A workshop to consider the effects of various proposed Space Station Freedom (SSF) grounding schemes was held. Expert from the plasma interactions community evaluated the impacts of environmental interactions on SSF under each of three proposed grounding schemes. The choice of the grounding scheme for the SSF power system was found to have important implications for SSF design. Interactions of the SSF power system and structure with the low earth orbit (LEO) plasma differ significantly between different grounding schemes. Environmental constraints will require modification of current SSF designs under any grounding scheme. Maintaining the present negative ground scheme may compromise SSF safety, structural integrity, and electromagnetic compatibility, and will increase contamination rates over alternate schemes. Positive grounding of the array requires redesign of the primary power system. Floating the array reduces the number of circuit changes in the primary power system but adds new hardware. Maintaining the present design will affect all parts of SSF. However, no impacts were identified on SSF systems outside of the electrical power system by positively grounding or floating the array.

Ferguson, Dale C.

Findings of the Joint Workshop on Evaluation of Impacts of Space Station Freedom Ground Configurations

At the workshop, experts from the plasma interactions community evaluated the impacts of environmental interactions on the Space Station Freedom (SSF) under each of the proposed grounding schemes. The grounding scheme chosen for the SSF power system was found to have serious implications for SSF design. Interactions of the SSF power system and structure with the low Earth orbit (LEO) plasma differ significantly between different proposed grounding schemes. Environmental constraints will require modification of current SSF designs under any grounding scheme. Maintaining the present negative-grounding scheme compromises SSF safety, structural integrity, and electromagnetic compatibility. It also will increase contamination rates over alternative grounding schemes. One alternative, positive grounding of the array, requires redesign of the primary power system in work package four. Floating the array reduces the number of circuit changes to work package four but adds new hardware. Maintaining the current design will affect all work packages; however, no impacts were identified on work packages one, two, or three by positively grounding or floating the array, with the possible exception of extra corona protection in multi-wire connectors.

Ferguson, Dale C.

Plasma sheath effects and voltage distributions of large high-power satellite solar arrays

Knowledge of the floating voltage configuration of a large array in orbit is needed in order to estimate various plasma-interaction effects. The equilibrium configuration of array voltages relative to space depends on the sheath structure. The latter dependence for an exposed array is examined in the light of two finite-sheath effects. One effect is that electron currents may be seriously underestimated. The other is that a potential barrier for electrons can occur, restricting electron currents. A conducting surface is assumed on the basis of a conductivity argument. Finite-sheath effects are investigated. The results of assuming thin-sheath and thick-sheath limits on the floating configuration of a linearly connected array are studied. Sheath thickness and parasitic power leakage are estimated. Numerically computed fields using a 3-D code are displayed in the thick-sheath limit.

Parker, L. W.

A one-megapixel image acquisition and processing system for solar oscillation studies

The 1-Mpixel image acquisition and processing system that has been installed at the Mt. Wilson observatory as part of the development effort for the NASA/ESA Solar Oscillations Imager Experiment of the projected Heliospheric Observatory mission is discussed. The system encompasses a high speed CCD camera with a 1024 x 1024-pixel virtual phase chip array, yielding a readout rate of about 800,000 pixels/sec; this allows the entire Mpixel array to be read out in just over 1 sec. The camera is interfaced with a floating point array processor that integrates several successive exposures from the CCD camera and differences selected pairs of integrated images. The system is currently being used to record and difference narrowband images of the sun.

Rhodes, Edward J., Jr.

Alternatives to the ISS Plasma Contacting Units

A spacecraft in a high-density equatorial LEO plasma will float negative relative to the ambient plasma. Because of the electron collection of exposed conductors on its solar arrays, it may float negative by up to its array voltage. The floating potential depends on the relative areas of electron and ion collection of the spacecraft. Early estimates of the International Space Station (ISS) potential were about -140 V relative to the surrounding plasma, because of its 160 V solar array string voltage. Because of the possibility of arcing of ISS structures and astronaut EMUs (spacesuits) into the space plasma, Plasma Contacting Units (PCUs) were added to the ISS design, to reduce the highly negative floating potentials by emitting electrons (effectively increasing the ion collecting area). In addition to the now-operating ISS PCUs, safety rules require another independent arc-hazard control method. In this paper, I discuss alternatives to the ISS PCUs for keeping the ISS floating potential at values below the arc-thresholds of ISS and EMU surface materials. Advantages and disadvantages of all of the recline loss will be presented.

Ferguson, Dale C.

Nonvolatile programmable neural network synaptic array

A floating-gate metal oxide semiconductor (MOS) transistor is implemented for use as a nonvolatile analog storage element of a synaptic cell used to implement an array of processing synaptic cells. These cells are based on a four-quadrant analog multiplier requiring both X and Y differential inputs, where one Y input is UV programmable. These nonvolatile synaptic cells are disclosed fully connected in a 32 x 32 synaptic cell array using standard very large scale integration (VLSI) complementary MOS (CMOS) technology.

Tawel, Raoul

A new system for observing solar oscillations at the Mount Wilson Observatory. I - System design and installation

An observation system designed to obtain daily measurements of solar photospheric and subphotospheric rotational velocities, from the frequency splitting of nonradial solar p-mode oscillations of degree greater than 150, is nearing completion of the Mount Wilson Observatory. The system will combine a 244 x 248 pixel CID camera with a high speed floating point array processor, a 32-bit minicomputer, and a large capacity disk storage system. These components will be integrated into the spectrograph of the 60-foot solar tower telescope at Mount Wilson.

Rhodes, E. J., Jr.

The sheath structure around a negatively charged rocket payload

The sheath structure around a rocket payload charged up to 460 V negative relative to the ambient ionospheric plasma is investigated experimentally and by computer simulations. The experimental results come from the Charge 2 sounding rocket experiment in which the payload was split into two separate sections (mother and daughter) connected with a conducting, insulated tether. In one of the experimental modes, the voltage between the payloads was increased linearly from 0 to 460 V in 2.5 s. A floating probe array was mounted on the mother with probes located 25, 50, 75, and 100 cm from the rocket surface. The internal impedance of the array was smaller than the probe/plasma impedance, which influenced the potential measurements. The measurements contain signatures, resulting from the outward expansion of the ion sheath with increasing negative mother potential. This conclusion is substantiated by computer simulations of space charge limited flow.

Neubert, T.

Observations of Transient ISS Floating Potential Variations During High Voltage Solar Array Operations

The International Space Station (ISS) continues to be a world-class space research laboratory after over 15 years of operations, and it has proven to be a fantastic resource for observing spacecraft floating potential variations related to high voltage solar array operations in Low Earth Orbit (LEO). Measurements of the ionospheric electron density and temperature along the ISS orbit and variations in the ISS floating potential are obtained from the Floating Potential Measurement Unit (FPMU). In particular, rapid variations in ISS floating potential during solar array operations on time scales of tens of milliseconds can be recorded due to the 128 Hz sample rate of the Floating Potential Probe (FPP) pro- viding interesting insight into high voltage solar array interaction with the space plasma environment. Comparing the FPMU data with the ISS operations timeline and solar array data provides a means for correlating some of the more complex and interesting transient floating potential variations with mission operations. These complex variations are not reproduced by current models and require further study to understand the underlying physical processes. In this paper we present some of the floating potential transients observed over the past few years along with the relevant space environment parameters and solar array operations data.

Willis, Emily M.

Behavior of Combined Dielectric-Metallic Systems in a Charged Particle Environment

The charging and discharging characteristics of an electrically isolated solar array segment were studied in order to simulate discharges seen during geomagnetic substorms. A solar array segment was floated while bombarded with monoenergetic electrons at various angles of incidence. The potentials of the array surface and of the interconnects were monitored using Trek voltage probes to maintain electrical isolation. A back plate was capacitively coupled to the array to provide information on the characteristics of the transients accompanying the discharges. Several modes of discharging of the array were observed at relatively low differential and absolute potentials (a few kilovolts). A relatively slow discharge response in the array was observed, discharging over one second with currents of nanoamps. Two types of faster discharges were also seen which lasted a few hundredths of a millisecond and with currents on the order of microamps. Some results indicate an electron emission process associated with the arcs.

Gordon, W. L.

Interactions between large space power systems and low-Earth-orbit plasmas

There is a growing tendency to plan space missions that will incorporate very large space power systems. These space power systems must function in the space plasma environment, which can impose operational limitations. As the power output increases, the operating voltage also must increase and this voltage, exposed at solar array interconnects, interacts with the local plasma. The implications of such interactions are considered. The available laboratory data for biased array segment tests are reviewed to demonstrate the basic interactions considered. A data set for a floating high voltage array test was used to generate approximate relationships for positive and negative current collection from plasmas. These relationships were applied to a hypothetical 100 kW power system operating in a 400 km, near equatorial orbit. It was found that discharges from the negative regions of the array are the most probable limiting factor in array operation.

Stevens, N. J.

Research in the design of high-performance reconfigurable systems

An initial design for the Bit Processor (BP) referred to in prior reports as the Processing Element or PE has been completed. Eight BP's, together with their supporting random-access memory, a 64 k x 9 ROM to perform addition, routing logic, and some additional logic, constitute the components of a single stage. An initial stage design is given. Stages may be combined to perform high-speed fixed or floating point arithmetic. Stages can be configured into a range of arithmetic modules that includes bit-serial one or two-dimensional arrays; one or two dimensional arrays fixed or floating point processors; and specialized uniprocessors, such as long-word arithmetic units. One to eight BP's represent a likely initial chip level. The Stage would then correspond to a first-level pluggable module. As both this project and VLSI CAD/CAM progress, however, it is expected that the chip level would migrate upward to the stage and, perhaps, ultimately the box level. The BP RAM, consisting of two banks, holds only operands and indices. Programs are at the box (high-level function) and system level. At the system level initial effort has been concentrated on specifying the tools needed to evaluate design alternatives.

Slotnick, D. L.

PASP, a high voltage array/plasma interaction experiment

The author discusses the photovoltaic array space power (PASP) experiment, which is designed to obtain data on the interaction between high-voltage photovoltaic arrays and the polar, low-earth plasma environment. Up to six small test arrays (three each of planar and concentrator designs) can be voltage biased over a range of +/- 500 V. During the bias voltage sequence, the array current leakage is measured and array arc events are monitored. If any arcing occurs the arc characteristics will be measured by a transient pulse monitor. An emitter is included to allow voltage bias to be applied to a plasma-charged or uncharged spacecraft. Similarly, the frames of the concentrator arrays can be left floating or can be tied to the negative array terminal. An environmental data scan is made before each bias voltage sequence. This scan collects information on the plasma, array-current-versus-voltage curves, and neutral particle partial pressure. The requirement for high voltages created problems which were met by circuit isolation and logical fault protection.

Burger, Dale R.