Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flip angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

MRI of bone marrow in the distal radius: in vivo precision of effective transverse relaxation times

The effective transverse relaxation time T2* is influenced by the presence of trabecular bone, and can potentially provide a measure of bone density as well as bone structure. We determined the in vivo precision of T2* in repeated bone marrow measurements. The T2* measurements of the bone marrow of the distal radius were performed twice within 2 weeks in six healthy young volunteers using a modified water-presaturated 3D Gradient-Recalled Acquisition at Steady State (GRASS) sequence with TE 7, 10, 12, 20, and 30; TR 67; flip angle (FA) 90 degrees. An axial volume covering a length of 5.6 cm in the distal radius was measured. Regions of interest (ROIs) were determined manually and consisted of the entire trabecular bone cross-section extending proximally from the radial subchondral endplate. Reproducibility of T2* and area measurements was expressed as the absolute precision error (standard deviation [SD] in ms or mm2) or as the relative precision error (SD/mean x 100, or coefficient of variation [CV] in %) between the two-point measurements. Short-term precision of T2* and area measurements varied depending on section thickness and location of the ROI in the distal radius. Absolute precision errors for T2* times were between 1.3 and 2.9 ms (relative precision errors 3.8-9.5 %) and for area measurements between 20 and 55 mm2 (relative precision errors 5.1-16.4%). This MR technique for quantitative assessment of trabecular bone density showed reasonable reproducibility in vivo and is a promising future tool for the assessment of osteoporosis.

NASA Discipline Musculoskeletal↗

Evidence for a bipolar nebula around the peculiar B(e) star HD 45677 from ultraviolet spectropolarimetry

We report the first ultraviolet spectropolarimetry of the peculiar B-type emission-line star with infrared excess HD 45677. The observations were obtained during the 1990 December Astro-l space shuttle mission with the Wisconsin Ultraviolet Photo-Polarimeter Experiment, and cover the spectral range 1400-3220 A. We also present the first optical spectropolarimetry, extending from the atmospheric cutoff to about 7600 A. The observed UV/optical linear polarization displays a strong increase toward shorter wavelengths indicative of scattering by circumstellar dust. The position angle of the intrinsic polarization flips by 90 deg in the near-UV as expected from a bipolar reflection nebula.

Schulte-Ladbeck, R. E.↗

Apparatus and method for improving spin recovery on aircraft

Previous research on airplane spinning and recovery has shown that at potential spin conditions (high angles of attack with rotation) the horizontal tail, depending upon its location, can create a wake about the vertical tail and rudder which can adversely affect airplane spin and recovery characteristics. Many methods of altering the tail geometry to modify these interference effects were investigated for improving airplane spin and recovery characteristics. Examples of changes includes relocation of the horizontal tail, increasing control surface travel, and use of a 'flip tail' that can be rotated to extreme angles for spin recovery. A device is provided which improves the spin recovery characteristics of aircraft which involves attaching the horizontal tail of the aircraft to the aircraft such that a gap remains between the root end of each horizontal tail section and the fuselage or vertical tail of the aircraft. The gaps measure between about 15 and 30 percent of the tail semispan. The gaps may be covered by shields which are released should a spin occur.

Stough, H. Paul, II↗

Fully symmetric nulling beam combiners

A simple method of nulling broadband light is presented. A mirror-symmetric pair of right-angle periscopes is first used to introduce a geometric field flip between two incident light beams,after which the light is combined by means of one of a number of constructive two-beam interferometers.

Aerospace instrumentation astronomical instruments↗

Modernization of the 60-inch telescope at the Mount Wilson Observatory

A contract for modernization of the Mount Wilson 60-inch telescope was awarded. Under this contract, the original hour angle and declination drives were replaced, digital coordinate readouts were added, a Cassegrain/ coude flip cage was built and installed, the telescope was completely rewired, a new control console was installed, and a coude spectrograph was completed. Extensive building modifications also were made to provide a working floor at mezzanine level for a computer and a coude observing room. These modifications and additions were completed by February 1970, and the telescope returned to regular and continuous use for stellar and planetary astronomy.

Source record↗

UVO to Far-IR Mirror Technology Development: Year 2 Status

UVO to Far-IR (UVO-FIR) mirror technology development project is a multiyear effort initiated in Fiscal Year (FY) 2022 to mature the Technology Readiness Level (TRL) of critical technologies required to enable ultra-stable telescope of the Habitable Worlds Observatory (HWO) mission. 2023/24 accomplishments include: continued investigations into gravity sag by comparing rotation test vs flip test, quantifying gravity sag as a function of temperature and designing mount for mirror whose G-sag with elevation angle is only coma. Significant progress in developing a methodology for specify optical surface microstructure, contamination cleanliness level and allowable micrometeoroid impacts. Support of HWO. And, a parametric cost model for x-ray telescopes and a parametric volume cost model for normal incidence telescopes.

H. Philip Stahl↗

Bench-top soldering aid for PC boards

Multiple-board rack allows technician to insert components into several boards, flip them all in single motion, and then systematically solder leads on reverse side. Two adjustable crossbars allow boards of any size up to 10 by 24 inches. Operator can rotate racks and adjust angle of boards from standing or sitting position.

Manton, N. R.↗

A low power X-ray diffractometer for soil analysis in remote locations employing a multiwire proportional counter detector array.

A low power X-ray powder diffraction system suitable for remote mineralogical analysis of lunar, planetary, or asteroid soils has been designed. A one Curie Fe-55 source provides a monochromatic X-ray beam of 5.9 keV. Seeman-Bohlin focusing geometry is employed in the camera, allowing peak detection to proceed simultaneously at all angles and obviating the need for moving parts. The detector system is an array of 500-600 proportional counters with a wire-spacing of 1 mm. An electronics unit comprising preamplifier, postamplifier, window discriminators, and storage flip-flops requiring only 3.5 milliwatts has been designed and tested. Total instrument power is less than 5 W.

Gregory, J. C.↗

On the 'flip-flop' instability of Bondi-Hoyle accretion flows

A simple physical interpretation is advanced by means of an analysis of the shock cone in the accretion flows past a compact object and with an examination of the accretion-line stability analyses. The stability of the conical shock is examined against small angular deflections with attention given to several simplifying assumptions. A line instability is identified in the Bondi-Hoyle accretion flows that leads to the formation of a large opening-angle shock. When the opening angle becomes large the instability becomes irregular oscillation. The analytical methodology is compared to previous numerical configurations that demonstrate different shock morphologies. The Bondi-Hoyle accretion onto a compact object is concluded to generate a range of nonlinear instabilities in both homogeneous and inhomogeneous cases with a quasiperiodic oscillation in the linear regime.

Livio, Mario↗

Thermal-capillary model for Czochralski growth of semiconductor materials

The success of efficiently calculating the temperature field, crystal radius, melt mensicus, and melt/solid interface in the Czochralski crystal growth system by full finite-element solution of the government thermal-capillary model is demonstrated. The model predicts realistic response to changes in pull rate, melt volume, and the thermal field. The experimentally observed phenomena of interface flipping, bumping, and the difficulty maintaining steady-state growth as the melt depth decreases are explained by model results. These calculations will form the basis for the first quantitative picture of Cz crystal growth. The accurate depiction of the melt meniscus is important in calculating the crystal radius and solidification interface. The sensitivity of the results to the equilibrium growth angle place doubt on less sophisticated attempts to model the process without inclusion of the meniscus. Quantitative comparison with experiments should be possible once more representation of the radiation and view factors in the thermal system and the crucible are included. Extensions of the model in these directions are underway.

Derby, J. J.↗

Crash tests of four identical high-wing single-engine airplanes

Four identical four place, high wing, single engine airplane specimens with nominal masses of 1043 kg were crash tested at the Langley Impact Dynamics Research Facility under controlled free flight conditions. These tests were conducted with nominal velocities of 25 m/sec along the flight path angles, ground contact pitch angles, and roll angles. Three of the airplane specimens were crashed on a concrete surface; one was crashed on soil. Crash tests revealed that on a hard landing, the main landing gear absorbed about twice the energy for which the gear was designed but sprang back, tending to tip the airplane up to its nose. On concrete surfaces, the airplane impacted and remained in the impact attitude. On soil, the airplane flipped over on its back. The crash impact on the nose of the airplane, whether on soil or concrete, caused massive structural crushing of the forward fuselage. The liveable volume was maintained in both the hard landing and the nose down specimens but was not maintained in the roll impact and nose down on soil specimens.

Vaughan, V. L., Jr.↗

Adjusting a Full Body Model to Mitigate Inverse Kinematics Artifacts in Opensim

BACKGROUND: In support of Vibration Isolation and Stabilization (VIS) system development for Human Health Countermeasures (HHC) exercise systems in space, such as the European Enhanced Exploration Exercise Device (E4D) [1], dynamic quantities required to model the response of a proposed VIS while considering the effect of VIS motion on the forces between the human and VIS platform were obtained using motion capture data [2]. On occasion, large-amplitude oscillatory spikes were found in the subject’s linear and angular momentum derivatives, affecting analyses that depend on forces and moments derived from motion capture. The purpose of this investigation was to identify causes of these artifacts and techniques for their resolution. METHODS AND RESULTS: To obtain the required human dynamic quantities to drive the VIS simulation, motion capture data was collected containing recorded trajectories of passive retroreflective markers on body landmarks of an exercising subject. Since the full body Rajagopal model [3] was originally used to enhance gait analysis, upper body joints did not require large Ranges of Motion (ROM). We thus modified the Rajagopal model [4, 5] to allow it to be used for upper body intensive exercises like those common to the E4D. OpenSim Inverse Kinematics (IK) [6] was performed using these scaled subject models to generate the joint angles throughout the exercise while minimizing marker error. At times, the arms were observed to ‘snap’ from one configuration to another, causing spike artifacts. Following IK, a custom OpenSim plugin [7] was used to determine the required dynamic quantities including the rates of change of the linear and angular momenta of the human. Since motion capture is recorded at a larger time step than required by the VIS simulation, the human center of mass location was fit with splines and a second derivative taken to obtain the momentum derivative, allowing the VIS simulation to maintain conservation of momentum when appropriate. In a few cases during this stage, artifacts much larger than the expected noise of the second derivatives were introduced. Investigation of cases containing artifacts revealed several modifications that could be made to the OpenSim model to improve IK results. Since OpenSim models use Euler angles and rotation sequences, ‘gimbal lock’ would be encountered in the arms when raised 90 degrees to the side (e.g., T-pose, some hang clean exercise, etc.). This was resolved by reorienting the horizontal axes at the shoulder joint by 45 degrees, placing ‘gimbal lock’ outside common arm ROM, with the arm ROMs adjusted following this change. Elbow and wrist ROMs could also be adjusted to allow realistic motion while at the same time limiting the likelihood of unrealistic orientations. On occasion, the arms flipped backwards when raised above the head. This was prevented by using medial elbow markers in scaling and IK. When medial markers were not available, the acromial joint location in the unscaled model was shifted before model scaling to better align the arm with available markers. Lastly, artifacts which became apparent after taking the second derivatives of spline-fit data were found to occur in cases when the pelvis rotation limit prevented the full range of motion of an exercise. These issues were resolved by unclamping the pelvis rotation limit. Through this investigation, an understanding of conditions leading to IK artifacts was acquired allowing the automation of artifact detection. These artifact detection and mitigation techniques can be applied toward modeling of upper body motions in aerospace and other fields for improved IK results.

C A Bell↗

Structural Basis for "Flip-Flop" Action of Human Pyruvate Dehydrogenase

The derivative of vitamin B1, thiamin pyrophosphate is a cofactor of pyruvate dehydrogenase, a component enzyme of the mitochondrial pyruvate dehydrogenase multienzyme complex that plays a major role in directing energy metabolism in the cell. This cofactor is used to cleave the C(sup alpha)-C(=O) bond of pyruvate followed by reductive acetyl transfer to lipoyl-dihydrolipoamide acetyltransferase. In alpha(sub 2)beta(sub 2)-tetrameric human pyruvate dehydrogenase, there are two cofactor binding sites, each of them being a center of independently conducted, although highly coordinated enzymatic reactions. The dynamic nonequivalence of two, otherwise chemically equivalent, catalytic sites can now be understood based on the recently determined crystal structure of the holo-form of human pyruvate dehydrogenase at 1.95A resolution. The structure of pyruvate dehydrogenase was determined using a combination of MAD phasing and molecular replacement followed by rounds of torsion-angles molecular-dynamics simulated-annealing refinement. The final pyruvate dehydrogenase structure included coordinates for all protein amino acids two cofactor molecules, two magnesium and two potassium ions, and 742 water molecules. The structure was refined to R = 0.202 and R(sub free) = 0.244. Our structural analysis of the enzyme folding and domain assembly identified a simple mechanism of this protein motion required for the conduct of catalytic action.

Ciszak, Ewa↗

K-Band Phased Array Developed for Low- Earth-Orbit Satellite Communications

Future rapid deployment of low- and medium-Earth-orbit satellite constellations that will offer various narrow- to wide-band wireless communications services will require phased-array antennas that feature wide-angle and superagile electronic steering of one or more antenna beams. Antennas, which employ monolithic microwave integrated circuits (MMIC), are perfectly suited for this application. Under a cooperative agreement, an MMIC-based, K-band phased-array antenna is being developed with 50/50 cost sharing by the NASA Lewis Research Center and Raytheon Systems Company. The transmitting array, which will operate at 19 gigahertz (GHz), is a state-of-the-art design that features dual, independent, electronically steerable beam operation ( 42 ), a stand-alone thermal management, and a high-density tile architecture. This array can transmit 622 megabits per second (Mbps) in each beam from Earth orbit to small Earth terminals. The weight of the total array package is expected to be less than 8 lb. The tile integration technology (flip chip MMIC tile) chosen for this project represents a major advancement in phased-array engineering and holds much promise for reducing manufacturing costs.

Anzic, Godfrey↗