Engineering PapersSearch

SEARCH · Engineering Papers

Results for “flight test technique”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

169 Tm ( n , γ ) cross section and statistical decay properties from measurements at the DANCE facility

Background: Radiative neutron capture on thulium, which is a monoisotopic element, plays a role in different applications such as nuclear astrophysics or nuclear burning environments. Considerable discrepancies—reaching 20%—exist between evaluations in the unresolved-resonance region. Furthermore, experimental data on statistical 𝛾 decay in odd-odd rare-earth nuclei is scarce. There are still open questions about the systematics of the so-called scissors mode in the 𝑀⁢1 photon strength function, especially in odd-odd nuclei. Purpose: This work is focused on two main topics—deriving experimental 169 Tm ⁢(𝑛,𝛾) cross section and studying statistical 𝛾 decay of 170 Tm, in particular properties of the scissors mode. Methods: The capture experiments to obtain experimental cross section were performed at the Los Alamos Neutron Science Center using the time-of-flight technique and employing the Detector for Advanced Neutron Capture Experiments. Measured coincident 𝛾-ray spectra were also compared with statistical simulations using the dicebox code to test different models of level density and photon strength functions. Results: The capture cross section was determined from 1.8 eV to 0.97 MeV, the broadest neutron-energy range ever measured for this isotope. Several new resonances have been observed. The statistical 𝛾 decay of 170 Tm cannot be reproduced without a scissors mode resonance centered at ≈ 3.3MeV. Conclusions: The measured cross section in the unresolved-resonance region is generally lower than the latest evaluations. The derived 169 Tm 𝑠-process abundance is expected to increase by a factor of 1.26, while the changes of the abundances of elements heavier than 169 Tm are in the order of 0.2%. The scissors mode properties in 170 Tm are similar to those deduced in previous analyses of neighboring nuclei 168 Er and 166 Ho .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Evaluating Model Robustness for Defect Identification and Classification in a Composite Aerostructure Material

Aircraft structures are required to have a high level of quality to satisfy their need for light weight, efficient flight, and withstanding high loads over their lifespan. These aerostructures are typically made from a composite material due to their good tensile strength and resistance to compression. To ensure their structural integrity, the composite material requires inspection for common flaws such as porosity, delaminations, voids, foreign object debris, and other defects. Ultrasonic testing (UT) is a popular non-destructive inspection (NDI) technique used for effectively evaluating the composite material. Current inspection methods rely heavily on human experience and are extremely time consuming. Therefore, there is a need for the development of techniques to reduce the manual inspection time. This work compares the performance of different deep learning-based methods in the identification and classification of defects. Deep learning has shown great promise in numerous fields, and we show its effectiveness in the evaluation of the composite aerostructure material. The methods developed here are both highly reliable with a top recall value of 98.64% as well as extremely efficient requiring an average of 4 s during the inferencing stage to evaluate new composites. Lastly, we investigate model robustness to concept drift by measuring its performance over time.

36 MATERIALS SCIENCE

3D reconstruction of an inertial-confinement fusion implosion with neural networks using multiple heterogeneous data sources

3D asymmetries are major degradation mechanisms in inertial-confinement fusion implosions at the National Ignition Facility (NIF). These asymmetries can be diagnosed and reconstructed with the neutron imaging system (NIS) on three lines of sight around the NIF target chamber. Conventional tomographic reconstructions are used to reconstruct the 3D morphology of the implosion using NIS [Volegov et al., J. Appl. Phys. 127, 083301 (2020)], but the problem is ill-posed with only three imaging lines of sight. Asymmetries can also be diagnosed with the real-time neutron activation diagnostics (RTNAD) and the neutron time-of-flight (nToF) suite. Since the NIS, RTNAD, and nToF each sample a different part of the implosion using different physical principles, we propose that it is possible to overcome the limitations of too few imaging lines of sight by performing 3D reconstructions that combine information from all three heterogeneous data sources. This work presents a new machine learning-based reconstruction technique to do just this. By using a simple physics model and group of neural networks to map 3D morphologies to data, this technique can easily account for data of multiple different types. A simple proof-of-principle is presented, demonstrating that this technique can accurately reconstruct a hot-spot shape using synthetic primary neutron images and a hot-spot velocity vector. In particular, the hot-spot’s asymmetry, quantified as spherical harmonic coefficients, is reconstructed to within ±4% of the radius in 90% of test cases. In the future, this technique will be applied to actual NIS, RTNAD, and nToF data to better understand 3D asymmetries at the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Chemical Characterization and Antimicrobial Activity of Green Propolis from the Brazilian Caatinga Biome

Green propolis, particularly from the unique flora of the Brazilian Caatinga biome, has gained significant interest due to its diverse chemical composition and biological activities. This study focuses on the chemical characterization and antimicrobial evaluation of Caatinga green propolis. Twelve compounds were isolated through different chromatographic techniques, including flavanones (naringenin, 7-O-methyleriodictyol, sakuranetin), flavones (hispidulin, cirsimaritin), flavonols (quercetin, quercetin-3-methyl ether, kaempferol, 6-methoxykaempferol, viscosine, penduletin), and one chalcone (kukulkanin B). Using liquid chromatography–quadrupole time-of-flight tandem mass spectrometry (LC-QToF-MS), a total of 55 compounds excluding reference standards were tentatively identified, which include flavonoids, phenolic acids derivatives, and alkaloids, with flavonols, flavanones, and flavones being predominant. Antimicrobial testing against pathogens revealed that the crude extract exhibited low inhibitory activity, against Gram-positive bacteria, including methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant Enterococcus faecium (VRE) (IC50: 148.4 and 120.98 µg/mL, respectively). Although the isolated compounds showed limited individual activity, a fraction containing sakuranetin and penduletin (Fraction 8) exhibited moderated activity against Cryptococcus neoformans (IC50: 47.86 µg/mL), while a fraction containing quercetin and hispidulin showed moderated activity against VRE (IC50: 16.99 µg/mL). These findings highlight the potential application of Caatinga green propolis as an antimicrobial agent, particularly against resistant bacterial strains, and underscore the importance of synergistic interactions between compounds in enhancing biological effects.

Aldana-Mejía, Jennyfer A. (ORCID:0000000307361899)

Hypersonic wake velocity measurements using acetone molecular tagging velocimetry

Molecular tagging velocimetry, a minimally intrusive laser diagnostic, was used to find quantitative off-body velocity measurements in the wake of both strut-mounted and free-flight spheres in hypersonic flow. Acetone gas seeded in the flow was excited using the fourth harmonic of a pulse-burst Nd:YAG laser. The experimental tests were validated and compared to simulations using a continuous Galerkin flow solver and an adaptive mesh refinement process. Near the centerline in the wake of the sphere, velocities between −105 and 65 m/s were observed due to reverse flow in the viscous shear layer. Similarly, the simulated data showed negative velocity values in the shear layer region. Outside of the shear layer, average velocities of 730 m/s were observed in both the experimental and simulated results. The overall average uncertainty for the strut-mounted and free-flight cases was estimated to have an accuracy of ±4% (±35.5m/s or 4.9%). In conclusion, this non-intrusive technique provides a velocity map of the wake behind a sphere under hypersonic conditions.

42 ENGINEERING

Versatile system for ion energy measurements generated by pulsed laser ionization: Insights into electron-ion dynamics

Ion energy distributions generated by pulsed laser interactions with materials are essential for applications ranging from materials science to oncology. Ion energy characterization is particularly important for an emerging mass spectrometry technique called virtual-slit cycloidal mass spectrometry (VS-CMS). The ion energy distribution influences the design and performance of VS-CMS instruments, as well as the efficacy of laser-driven ionization methods in various fields. Several established techniques, including the retarding potential method, time-of-flight (TOF) analysis, and electrostatic energy analyzers, have been employed to measure ion energy distributions. The wide range of ion energies reported highlights the strong dependence of ion energy on laser parameters, target materials, and experimental conditions, as well as the necessity of making independent measurements of the ion energy distribution for specific laser systems and materials. This paper presents the design and characterization of a simple TOF-based apparatus for measuring ion energy distributions from pulsed laser ionization without external fields. This approach minimizes perturbation of electron-ion dynamics and enables simultaneous energy measurements at multiple spatial positions. Here, the apparatus was tested using a nanosecond pulsed Nd:YAG laser operating at 1064 nm, 532 nm, and 266 nm on solid copper sheets at various laser fluences. Simultaneous measurements at different distances provide new insights into ion-electron interactions post-ionization and demonstrate the influence of laser wavelength and fluence on ion energy distributions.

Ion energy

White paper on light sterile neutrino searches and related phenomenology

This white paper provides a comprehensive review of our present understanding of experimental neutrino anomalies that remain unresolved, charting the progress achieved over the last decade at the experimental and phenomenological level, and sets the stage for future programmatic prospects in addressing those anomalies. It is purposed to serve as a guiding and motivational "encyclopedic" reference, with emphasis on needs and options for future exploration that may lead to the ultimate resolution of the anomalies. We see the main experimental, analysis, and theory-driven thrusts that will be essential to achieving this goal being: 1) Cover all anomaly sectors -- given the unresolved nature of all four canonical anomalies, it is imperative to support all pillars of a diverse experimental portfolio, source, reactor, decay-at-rest, decay-in-flight, and other methods/sources, to provide complementary probes of and increased precision for new physics explanations; 2) Pursue diverse signatures -- it is imperative that experiments make design and analysis choices that maximize sensitivity to as broad an array of these potential new physics signatures as possible; 3) Deepen theoretical engagement -- priority in the theory community should be placed on development of standard and beyond standard models relevant to all four short-baseline anomalies and the development of tools for efficient tests of these models with existing and future experimental datasets; 4) Openly share data -- Fluid communication between the experimental and theory communities will be required, which implies that both experimental data releases and theoretical calculations should be publicly available; and 5) Apply robust analysis techniques -- Appropriate statistical treatment is crucial to assess the compatibility of data sets within the context of any given model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Elemental analysis of air-sensitive frozen molten salt samples using an inert transfer chamber for LIBS/LA-ICP-TOF-MS analysis

A novel inert sample transfer system was developed and employed to enable, for the first time, the analysis of air-sensitive salt samples in a two-volume ablation cell using simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation (LA)-inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) analysis. Molten salts are of growing interest as a medium for advanced nuclear reactors and nuclear fuel reprocessing technologies continue to be developed around their use. However, compositional analysis of molten salt samples can be challenging because of their air-sensitive nature and varying solubilities leading to inaccurate measurements when digested. LA-based analysis provides an alternate method to digestion and can provide rapid elemental information with little sample preparation. In this study, LIBS and LA-ICP-TOF-MS were used to analyze the Ce content in frozen salt samples taken from a series of electrochemical experiments. Calibrations were built for each technique, and the resulting limits of detection for Ce were estimated to be 107 and 58 µg g −1 for LIBS and LA-ICP-TOF-MS, respectively. Test samples from the electrochemical experiments were analyzed using these calibrations. The results matched bulk digestion-based ICP-optical emission spectroscopy values, and daily trends in Ce concentration changes were identified. Additionally, the LIBS and LA-ICP-TOF-MS analysis was demonstrated for identifying microgram per gram levels of components and detecting trace contaminants. The impurities detected by LIBS included Al, Mg, Ca, and Na. The impurities detected by LA-ICP-TOF-MS included W, Ag, Al, Fe, Ni, Mo, Nd, Sm, Th, and U.

Andrews, Hunter B. [Oak Ridge National Laboratory

Status Report on Design of In-situ Thermomechanical Testing at LANSCE

Nuclear fuel encounters severe thermomechanical environments in which its mechanical response is determined by its microstructure, temperature and stress level histories. Simulating the response of such microstructures is crucial for predicting both performance and transient fuel mechanical responses and experimental verification of such predictions is therefore of great interest. While most of the deformation in a nuclear fuel rod occurs in the cladding, deformation of the fuel itself is still of interest with deformation mechanisms at operating temperature and above including creep, swelling, cracking as well as pellet-clad interaction. Characterization of these properties and understanding of the underlying deformation phenomena at operating or excursion temperatures is therefore of great importance for development and ultimately licensing of improved and novel nuclear fuel forms. Diffraction techniques offer unique insight on the atomistic (e.g. crystal structure) and microstructure (e.g. phase transformations, texture, defects) length scales and have a long history of providing unique data to inform relevant deformation models that enable the required predictive capabilities. For example, dislocations lead to diffraction peak broadening that can be characterized to estimate the dislocation density and study the role of dislocations on the deformation while measuring lattice strains allows to studie load sharing in two phase materials. In this report the requirements for a sample environment for high temperature deformation of nuclear fuels are defined. The HIPPO neutron time-of-flight diffractometer at LANSCE will host this sample environment and is also described. This instrument covers diffraction angles from 140° to 40° and is also equipped with an event-mode neutron imaging detector system, enabling energy-resolved neutron imaging in parallel with the diffraction that could measure sample temperature from Doppler broadening of neutron absorption resonances or measure pore densities from changes in the attenuation. Designs of devices to characterize thermomechanical properties of nuclear fuel without diffraction are also considered to guide the design. While this report is focused on applications for nuclear fuels, the device can also characterize cladding, moderator or structural materials and therefore contribute to other fields of research and development for advanced reactors. The temperatures planned to be reached are above 2000℃, thus enabling characterization of LWR reactor fuels under accident scenarios but also reaching temperatures of fuels developed for nuclear thermal propulsion and providing opportunities to characterize those. In conjunction with the energy-resolved neutron imaging detector, this setup would allow to measure neutron cross-sections at high temperatures, filling a gap towards development of reactors operating at high temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

A Scalable & Non-Destructive Characterization Strategy to Study Semiconductor/Dielectric Interfaces and Predict Wafer-Level Device Performance

The defect density present at the dielectric-semiconductor interface in an MOS structure directly influences the channel carrier characteristics in semiconductor devices, especially in wide bandgap material systems used in power devices. While these trap defects are typically quantified through electrical characterization of MOS-capacitor test structures, this treatment offers very little insight into the physical nature of interface defects. Such shortcomings demand a physical characterization strategy to guide fabrication optimization. X-ray photoelectron spectroscopy (XPS) is suggested as a viable technique to determine chemical data for dielectric interfaces formed using atomic layer deposition (ALD) on GaN substrates. Previously, 1-D XPS characterization has confirmed the presence of a Ga x O y interlayer between ALD dielectrics and the GaN substrate. In this work, XPS data is serially collected to form 2-D images of an ALD-Al 2 O 3 /GaN interface as a proof-of-concept experiment for in-situ XPS quality monitoring during ALD processing. The information provided by this work reveals some of the challenges for incorporating XPS characterization as an in-situ strategy during fabrication of GaN-based devices. Separately, electrical mapping of a 2-D array of ALD-Al 2 O 3 /GaN MOS-capacitor devices provide a means to quantify the spatial variations in interface quality across a single wafer. Physical characterization techniques, such as time-of-flight secondary ion mass spectroscopy, provide additional chemical information about the Al 2 O 3 /Ga x O y /GaN structure that complement the electrical mapping results. This analysis shows that a higher Ga x O y content correlates with higher interface state defects for trap energies deep in the band gap.

42 ENGINEERING

Integrating Flow Imaging Analysis and Single-Particle ICP-TOFMS for Comprehensive Micro- and Nanoplastic Characterization

Flow imaging analysis (FIA), provides composition-agnostic morphological characterization. These measurements of particle size and shape are valuable to mass-based analysis, such as single particle inductively coupled plasma time-of-flight mass spectrometry (sp-ICP-TOFMS), which provides quantitative data on elements within particles. Using these two methods together enables informed use of geometric assumptions required by sp-ICP-TOFMS, as particle mass is typically converted to a particle diameter using assumed-spherical geometry. To validate this concept, parallel measurements to determine particle diameters were performed by FIA and sp-ICP-TOFMS on four particle suspensions: 300 nm polystyrene Eu-doped nanoparticles, 1 μm Fe-rich beads, 3 μm four element calibration polystyrene beads and 5 μm polystyrene beads. The Fe-particles obtained the highest percent difference from the manufacturer’s nominal diameter, as the mean diameter obtained by FIA was overestimated by 21% and sp-ICP-TOFMS underestimated the mean diameter by 20.7%. Two types of particles were selected to test the effect of varying the particle number concentrations (PNC) on sizing accuracy, and both methods accurately sized each particle population at the PNC expected. Single particle analysis of carbon has continued to be a popular research topic, with direct applications to environmental pollutants in terms of nano- and micro- plastics. Real-world plastic particles were studied, and FIA’s measured circularity values demonstrated that the particles deviated from spherical geometries, therefore sp-ICP-TOFMS data should be interpreted as mass-based rather than size-based. Combining these techniques enables improved interpretation of particle populations and evaluation of particle sizes.

Szakas, Sarah [ORNL] (ORCID:0000000241332197)

Multi-technique characterization of iron reduction by an Antarctic Shewanella : an analog system for putative Martian biosignature identification

ABSTRACT Microbes from terrestrial extreme environments enable testing of biosignature production in conditions relevant to astrobiological targets. Mars, which was likely more conducive to life during early warmer and wetter epochs, has inspired missions that search for signs of early life in the surficial rock record, including mineral or organic biosignatures. Microbial iron reduction is a common and ancient metabolism that may have also operated on other rocky celestial bodies. To investigate biosignature production during iron reduction, aShewanellasp. (strain BF02_Schw) isolated from a subglacial discharge known as Blood Falls, Antarctica, was incubated with the electron acceptor ferrihydrite (Fh). Biosignatures associated with Fh reduction were identified using a suite of techniques currently utilized or proposed for Mars missions, including X-ray diffraction and infrared, Mössbauer, and Raman spectroscopy. The biotic origin of features was validated by transcriptional changes observed between treatments with and without Fh and comparison to killed controls. In live treatments, Fh was reduced to magnetite and goethite, both detected in Martian lacustrine basins. Several soluble and volatile metabolites were also detected, including riboflavin and dimethyl sulfide (DMS), which could be astrobiological indicators of active microbial processes. While none of the identified biosignatures individually would serve as definitive proof of life (past or present), detecting concomitant features associated with known terrestrial biotic processes would provide compelling rationale for more targeted life detection missions. Terrestrial extremophiles can support the exploration of astrobiologically relevant microbial processes, validation of life detection instrumentation, and potentially the discovery of new biomarkers. IMPORTANCE Culture-based experiments with terrestrial extremophiles can elucidate biosignatures that may be analogous to those produced under extraterrestrial conditions, and thus inform sampling and technology strategies for future missions. Here, we demonstrate the production of several biosignatures under iron-reducing conditions byShewanellasp. BF02_Schw, originally isolated from an Antarctic analog feature. These biosignatures could be detectable using flight-ready instrumentation. Growth experiments with terrestrial extremophiles can identify biosignatures measurable by current methodologies and inform the development and optimization of techniques for detecting extant or extinct life on other worlds.

Biotechnology & Applied Microbiology

In-orbit performance of the soft X-ray imaging telescope Xtend aboard XRISM

Here, we present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently operating X-ray observatories. XRISM/Xtend has a large field of view of ${38{^{\prime }_{.}}5}$ $\times$ ${38{^{\prime }_{.}}5}$, covering an energy range of 0.4–13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170–180 eV at 6 keV, which meets the mission requirement and enables us to resolve He-like and H-like Fe K$\alpha$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in the Soft X-ray Imager (SXI) onboard the previous Hitomi mission—light leakage and crosstalk events—are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C 273 results in an effective area measured to be $\sim$420 cm$^{2}$ at1.5 keV and $\sim$310 cm$^{2}$ at 6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations; the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared with other major X-ray instruments onboard satellites, combined with the largest grasp ($\Omega _{\rm eff}\sim 60$ cm$^2$ deg$^2$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near-future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

instrumentation: detectors: Xtend

Dark Energy Survey Year 6 results: cell-based coadds and METADETECTION weak lensing shape catalogue

We present the metadetection weak lensing galaxy shape catalogue from the 6-yr Dark Energy Survey (DES Y6) imaging data. This data set is the final release from DES, spanning 4422 deg 2 of the southern sky. We describe how the catalogue was constructed, including the two new major processing steps, cell-based image coaddition, and shear measurements with metadetection. The DES Y6 M etadetection weak lensing shape catalogue consists of 151 922 791 galaxies detected over riz bands, with an effective number density of n eff = 8.22 galaxies per arcmin 2 and shape noise of σ e = 0.29. We carry out a suite of validation tests on the catalogue, including testing for point spread function (PSF) leakage, testing for the impact of PSF modelling errors, and testing the correlation of the shear measurements with galaxy, PSF, and survey properties. In addition to demonstrating that our catalogue is robust for weak lensing science, we use the DES Y6 image simulation suite to estimate the overall multiplicative shear bias of our shear measurement pipeline. We find no detectable multiplicative bias at the roughly half-per cent level, with m = (3.4 ± 6.1) x 10 –3 , at 3σ uncertainty. This is the first time both cell-based coaddition and Metadetection algorithms are applied to observational data, paving the way to the Stage-IV weak lensing surveys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND