High Reliability Arbitrary Pulse Pattern Laser Amplifier
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
This project is intended to advance the US position in laser diae~osis and treatment of disease in three thrust areas. A first laser system will advance the US position in photodynamic therapy whereby dyes are introduced into selected tissue and laser treatment with wavelena@ matching the dyes’ absorption band allows treatment of only the desired tissue. This effort will focus on the development and application of diode arrays delivering up to 10 watts at wavelengths of 657 nm, 675 nm and 695 nm with fiber optic delivery systems. This system would replace existing cumbersome systems with a compact diode array system. A second laser system is intended to advance the US position in the medical use of lasers in dermatology to remove port wine stains. The project will involve the development of a new all solid-state laser system to deliver light at 585 nm for the d~ect removal of port wine stains in human skin. This solid-state system would replace the currently used dye laser system with a compact, more efficient, less costly, environmentally benign solid-state laser system. Additionally this new laser system will offer new flexibility in the pulse format allowing treatment on a wider range of patients. A third laser system is targeted to develop a diode-pumped TrnYAG laser system operating at 1.9 pm to drill small holes in animal eggs with the goal of improving fertility. This system would replace the current excimer system at 308 nm, which has undesirable mutagenic problems
The high brightness negative ion injector combines multiple individual low-duty-factor H- ion sources (multiplexing) in a manner that allows flexibility in final pulse format and beam duty factor up to CW and increases reliability by eliminating an otherwise single-point failure usually associated with using a single ion source. The multiplexing of multiple beams in new injector system also preserves the beam quality of each individual ion source, eliminating a significant source of beam quality degradation usually associated with combining beams.
While conformal and wearable devices have become one of the most desired formats for printable electronics, it is challenging to establish a scalable process that produces stable conductive patterns but also uses substrates compatible with widely available wearable materials. Here, we describe findings of an investigation of a nanoalloy ink printed and pulsed laser sintered conductive patterns as flexible functional devices with enhanced stability and materials compatibility. While nanoparticle inks are desired for printable electronics, almost all existing nanoparticle inks are based on single-metal component, which, as an electronic element, is limited by its inherent stabilities of the metal such as propensity of metal oxidation and mobility of metal ions, especially in sintering processes. The work here has demonstrated the first example in exploiting plasmonic coupling of nanoalloys and pulsed-laser energy with controllable thermal penetration. The experimental and theoretical results have revealed clear correlation between the pulsed laser parameters and the nanoalloy structural characteristics. The superior performance of the resulting flexible sensor device, upon imparting nanostructured sensing materials, for detecting volatile organic compounds has significant implications to developing stable and wearable sensors for monitoring environmental pollutants and breath biomarkers. This simple “nanoalloy printing 'laser sintering' nanostructure printing” process is entirely general to many different sensor devices and nanostructured sensing materials, enabling the ability to easily construct sophisticated sensor array.
This presentation discusses the new PTRAC capabilities and workflows. The PTRAC capability in MCNP6.3 has seen a massive overhaul since MCNP6.2. The new HDF5 file format allows for both MPI- and thread-based parallelism. MCNPTools has been updated to handle the new HDF5 PTRAC format and is now open sourced on GitHub. Built-in capabilities, such as the pulse-height tally coincident capture special treatment, can largely be replicated through separate postprocessing scripts that leverage both PTRAC and MCNPTools. This allows for greater flexibility in user-specified and controlled detector response functionality, ultimately using the MCNP code for what it is best at (i.e., particle transport).
Space-time structured laser pulses feature an intensity peak that can travel at an arbitrary velocity while maintaining a near-constant profile. These pulses can propagate in uniform media, where their frequencies are correlated with continuous transverse wave vectors, or in structured media, such as a waveguide, where their frequencies are correlated with discrete mode numbers. Here, we demonstrate the formation and propagation of arbitrary-velocity laser pulses in a plasma waveguide where the intensity can be orders of magnitude higher than in a solid-state waveguide. The flexibility to control the velocity of the peak intensity in a plasma waveguide enables new configurations for plasma-based sources of radiation and energetic particles, including THz generation, laser wakefield acceleration, and direct laser acceleration.
Multi-principal elemental NiCoCr thin films with compositional flexibility have potential applications as a thermal barrier, corrosion-resistant coatings, and functional energy materials. In this study, the non-stochiometric multi-principal element alloy thin film formation behavior from an equiatomic ablation target of NiCoCr using pulsed laser deposition has been reported. Here, the effect of varying laser fluence on compositions of constituent elements in the NiCoCr thin films is systematically investigated. The increase in laser fluence typically increases the likelihood of acquiring undesirable particulates in thin films. Therefore, to maintain the film quality the laser fluences are adjusted within the range of 1.3–3.3 J·cm -2 , while the film thicknesses are kept constant at ~30 nm. Results show that the constituent elements are well-distributed in the formed NiCoCr thin films, however, having average atomic percentages of Ni and Cr twice as high as Co irrespective of the equiatomic composition of individual elements in the ablation target. This stochiometric alteration in the as-deposited thin films is governed by the rate of ablation and subsequent evaporation of each element, which is facilitated by the optical properties and vapor pressure of individual constituent elements. Additionally, electron energy-loss spectroscopy and x-ray absorption spectroscopy analysis reveal that the thin films have partially oxidized, with the Cr oxidation contributing the most to the O-K edge in comparison to Ni and Co. Finally, this study presents a laser-assisted pathway for fabricating compositionally flexible NiCoCr thin films and develops an understanding of the non-equilibrium laser-material interactions and how the intrinsic properties of constituent elements affect the stoichiometric flow of materials from the target to the final film deposition.
In this study, we have extended the detector response function toolkit (DRiFT) to provide modeling capabilities of semiconductor sensors. DRiFT provides realistic nuclear instrumentation response by post-processing Monte-Carlo N-particle (MCNP®) radiation transport outputs. MCNP® is capable of modeling radiation transport in complex environments, but has limited detector physics and readout electronics modeling capabilities. Semiconductor detector response can be calculated with a high-fidelity for a flexible range of environments by utilizing MCNP® to simulate radiation interactions inside of detector volumes, and then using DRiFT to model charge transport and signal formation in the semiconductor, as well as the readout electronics. DRiFT models charge transport in the semiconductor, the preamplifier, shaping amplifier, pulse pile-up, and electronic noise to generate detector response. The semiconductor application in DRiFT can model a range of semiconductor materials, shapes, and sizes; and is demonstrated here for a large volume coaxial high-purity germanium (HPGe) detector. Here, we compare detector response functions of a coaxial HPGe detector with measurement of 60 Co, 133 Ba, and 137 Cs at varying count rates, and we conduct a parameter study to demonstrate the effect of changing parameters in the DRiFT simulation. The HPGe detector response function shows excellent agreement with measurements of difference sources with varying dead times and count rates.
The Laser Applications in Materials Processing (LAMP) instrument is a new end-station for soft X-ray imaging, high-field physics, and ultrafast X-ray science experiments that is available to users at the Linac Coherent Light Source (LCLS) free-electron laser. While the instrument resides in the Atomic, Molecular and Optical science hutch, its components can be used at any LCLS beamline. The end-station has a modular design that provides high flexibility in order to meet user-defined experimental requirements and specifications. The ultra-high-vacuum environment supports different sample delivery systems, including pulsed and continuous atomic, molecular, and cluster jets; liquid and aerosols jets; and effusive metal vapor beams. It also houses movable, large-format, high-speed pnCCD X-ray detectors for detecting scattered and fluorescent photons. Multiple charged-particle spectrometer options are compatible with the LAMP chamber, including a double-sided spectrometer for simultaneous and even coincident measurements of electrons, ions, and photons produced by the interaction of the high-intensity X-ray beam with the various samples. Here in this paper we describe the design and capabilities of the spectrometers along with some general aspects of the LAMP chamber and show some results from the initial instrument commissioning.
Highlights: • The alumina multilayer structure with alternating high and low refractive index is fabricated. • This multilayer shows a strong photonic band gap (PBG) and vivid film colors. • The first PBG could be modulated easily by varying the duration time of constant high or low voltages. • Fabrication of the photonic crystal is obtained by directly electrochemical anodization. • The formation mechanism of multilayer is also discussed. - Abstract: The alumina nanolayer structure with alternating high and low porosities is conveniently fabricated by applying a modified pulse voltage waveform with constant high and low voltage. This structure shows the well-defined layer in a long-range structural periodicity leads to a strong photonic band gap (PBG) from visible to near infrared and brilliant film colors. Compared with the previous reported tuning method, this method is more simple and flexible in tuning the PBG of photonic crystals (PCs). The effect of duration time of high, low and 0 V voltages on PBG is discussed. The first PBG could be modulated easily from the visible to near infrared region by varying the duration time of constant high or low voltages. It is also found that the 0 V lasting for appropriate time is helpful to improve the quality of the PCs. The formation mechanism of multilayer is also discussed.
Project X is a high-intensity proton facility being developed to support a world-leading program of Intensity Frontier physics over the next two decades at Fermilab. Project X is an integral part of the U.S. Intensity Frontier Roadmap as described in the P5 report of May 2008 [1] and within the Fermilab Strategic Plan of November 2011 [2]. This document represents Part I of the “Project X Book” describing the Project X accelerator facility and the broad range of physics research opportunities enabled by Project X. Parts II and III provide in-depth descriptions of the physics research program, both within and beyond particle physics [3]. The primary elements of the U.S. program to be supported by Project X include: Neutrino Experiments: Experimental studies of neutrino oscillations and neutrino interaction physics with ultra-intense neutrino beams provided by a high-power proton source with energies up to 120 GeV, utilizing near detectors at the Fermilab site and massive detectors at distant underground laboratories. Goal: At least 2 MW of proton beam power at any energy between 60 to 120 GeV; several hundred kW of proton beam power on target at 8 GeV. Kaon, Muon, Nucleon, and Neutron Precision Experiments: World-leading experiments studying ultra-rare kaon decays, searching for muon-to-electron conversion and nuclear electron dipole moments (EDMs), and exploring neutron properties at very high precision. Goal: MW-class proton beams supporting multiple experiments at 1 and 3 GeV, with flexible capability for providing distinct beam formats to concurrent users while allowing simultaneous operations with the neutrino program. Material Science and Nuclear Energy Applications: High-intensity accelerator, spallation, target and transmutation technology demonstrations will provide critical input into the design of future energy systems, including next generation fission reactors, nuclear waste transmutation systems and future thorium fuel-cycle power systems. Possible applications of muon spin rotation techniques provide sensitive probes of the magnetic structure of materials. Goal: Provide MW-class proton beams at 1 GeV, coupled with novel targets required to support a broad range of materials science and energy applications. Platform for Evolution to Future Frontier Facilities: A high-intensity proton source will strengthen and modernize the Fermilab injector complex, providing a robust platform upon which to build future frontier facilities. The Neutrino Factory and Muon Collider are examples that would provide world-leading capabilities at the Intensity and Energy Frontiers for many decades to come. Goal: Provide a straightforward upgrade path for a 4 MW, low-duty-factor source of protons at energies between 5 and 15 GeV. These four elements are expected to form the basis of the Mission Need statement required for the Department of Energy (DOE) Critical Decision 0 (CD-0), and represent the fundamental design criteria for Project X. The following chapters present the Reference Design for the Project X accelerator facility. The Reference Design is based on a continuous wave (CW) superconducting (SC) linac providing up to 1 and 3 MW of beam power at 1 and 3 GeV respectively. A pulsed linac provides acceleration of roughly 4% of the beam delivered from the CW linac to the 8 GeV injection energy of the existing Recycler/Main Injector complex. Upgrades to the Recycler and Main Injector support a factor of three increase, beyond current capabilities, in proton beam power at 60 to 120 GeV. The Reference Design represents a facility that will be unique in the world with unmatched capabilities for the delivery of very high beam power, with flexible beam formats, to multiple users at multiple energies. The utilization of linacs within the Project X facility enables capabilities beyond what is achievable with circular accelerators. It is anticipated that the final configuration and operating parameters of the complex will be further refined through the R&D program in advance of CD-2.
The extraction of heat from hot rock requires circulation of fluid through fracture networks. Because the geometry and connectivity of these fractures determines the efficiency of fluid circulation, many tools are used to characterize fractures before and after development of the reservoir. Under this project, a new tool was developed that allows hydraulic connectivity between geothermal boreholes to be identified. Nanostrain in rock fractures is measured using fiber optic distributed acoustic sensing (DAS). This strain is measured in one borehole in response to periodic pressure pulses induced in another borehole. The strain in the fractures represents hydraulic connectivity between wells. DAS is typically used at frequencies of Hz to kHz, but strain at mHz frequencies were measured for this project. The tool was demonstrated in the laboratory and in the field. In the laboratory, strain in fiber optic cables was measured in response to compression due to oscillating fluid pressure. DAS recorded strains as small as 10 picometer/m in response to 1 cm of water level change. At a fractured crystalline rock field site, strain was measured in boreholes. Fiber-optic cable was mechanically coupled borehole walls using pressured flexible liners. In one borehole 30 m from the oscillating pumping source, pressure and strain were measured simultaneously. The DAS system measured fracture displacement at frequencies of less than 1 mHz (18 min periods) and amplitudes of less than 1 nm, in response to fluid pressure changes of less 20 Pa (2 mm of water). The attenuation and phase shift of the monitored strain signal is indicative of the permeability and storage (compliance) of the fracture network that connects the two wells. The strain response as a function of oscillation frequency is characteristic of the hydraulic structure of the formation. This is the first application of DAS to the measurement of low frequency strain in boreholes. It has enormous potential for monitoring geothermal reservoirs for purposes of understanding reservoir compliance and for assuring security of injection fluids. Periodic pressure pulses can be induced by oscillating injection or pumping during operation so the system could provide real time reservoir data. DAS cable may already be installed at a site as it is becoming increasingly used for seismic observation. Simulations conducted for this project indicate that strain should be propagated through borehole cements, so observations can be made outside of well casing. In uncased holes, the cable would need to be mechanically coupled to the borehole wall to provide measurements. One option would be to install fiber into cemented and abandoned boreholes to extend their utility.
In this paper, we report a simple method to form conductive copper lines by scanning a single-beam femtosecond pulse laser on a plastic substrate covered with copper nitride (Cu{sub 3}N) film. The Cu{sub 3}N films were prepared by DC magnetron sputtering in the presence of an Ar + N{sub 2} atmosphere at 100 °C. The influence of the laser power and scanning speed on the formed copper line width, surface features, and morphology was analyzed by means of optical microscopy, X-ray diffraction, non-contact 3D profilometer, and scanning electron microscopy. The experimental results demonstrate that low laser power and low scanning speed favor the formation of uniform and flat Cu lines. After process optimization, copper lines with a width less than 5 μm were obtained, which provides an attractive application prospect in the field of flexible electronic devices.
Extracorporeal membrane oxygenation (ECMO) provides mechanical circulatory support essential for survival in infants and children with acute cardiac decompensation. However, ECMO also causes metabolic disturbances, which contribute to total body wasting and protein loss. Cardiac stunning can also occur which prevents ECMO weaning, and contributes to high mortality. The heart may specifically undergo metabolic impairments, which influence functional recovery. We tested the hypothesis that ECMO alters oxidative. We focused on the amino acid leucine, and integration with myocardial protein synthesis. We used a translational immature swine model in which we assessed in heart (i) the fractional contribution of leucine (FcLeucine) and pyruvate (FCpyruvate) to mitochondrial acetyl-CoA formation by nuclear magnetic resonance and (ii) global protein fractional synthesis (FSR) by gas chromatography-mass spectrometry. Immature mixed breed Yorkshire male piglets (n = 22) were divided into four groups based on loading status (8 hours of normal circulation or ECMO) and intracoronary infusion [13C6,15N]-L-leucine (3.7 mM) alone or with [2-13C]-pyruvate (7.4 mM). ECMO decreased pulse pressure and correspondingly lowered myocardial oxygen consumption (~ 40%, n = 5), indicating decreased overall mitochondrial oxidative metabolism. However, FcLeucine was maintained and myocardial protein FSR was marginally increased. Pyruvate addition decreased tissue leucine enrichment, FcLeucine, and Fc for endogenous substrates as well as protein FSR. Conclusion: The heart under ECMO shows reduced oxidative metabolism of substrates, including amino acids, while maintaining (i) metabolic flexibility indicated by ability to respond to pyruvate, and (ii) a normal or increased capacity for global protein synthesis, suggesting an improved protein balance.
Lasers operating in the Ince-Gaussian (IG) mode have potential applications for optical manipulation of microparticles and formation of optical vortices, as well as for optical trapping and optical tweezers. Versatile, self-Q-switched, high-peak-power, high-repetition-rate Cr, Nd:YAG microchip lasers operating in the IG mode are implemented under tilted, tightly focused laser-diode pumping. An average output power of over 2 W is obtained at an absorbed pump power of 6.4 W. The highest optical-to-optical efficiency of 33.2% is achieved at an absorbed pump power of 3.9 W. Laser pulses with a pulse energy of 7.5 μJ, pulse width of 3.5 ns and peak power of over 2 kW are obtained. A repetition rate up to 335 kHz is reached at an absorbed pump power of 5.8 W. Highly efficient, versatile, IG-mode lasers with a high repetition rate and a high peak power ensure a better flexibility in particle manipulation and optical trapping. (control of laser radiation parameters)
The layered Ruddlesden–Popper crystal structure can host a broad range of functionally important behaviors. In this work, we establish extraordinary configurational disorder in a layered Ruddlesden–Popper (RP) structure using entropy stabilization assisted synthesis. A protype A 2 CuO 4 RP cuprate oxide with five cations on the A-site sublattice is designed and fabricated into epitaxial single crystal films using pulsed laser deposition. When grown on a near lattice matched substrate, the (La 0.2 Pr 0.2 Nd 0.2 Sm 0.2 Eu 0.2 ) 2 CuO 4 film features a T'-type RP structure with uniform A-site cation mixing and square-planar CuO4 units. These observations are made with a range of combined characterizations using X-ray diffraction, atomic-resolution scanning transmission electron microscopy, energy-dispersive X-ray spectroscopy, and X-ray absorption spectroscopy measurements. It is further found that heteroepitaxial strain plays an important role in crystal phase formation during synthesis. Compressive strain over ~1.5% results in the formation of a non-RP cubic phase consistent with a Cu X 2O 4 spinel structure. The ability to manipulate configurational complexity and move between 2D layered RP and 3D cubic crystal structures in cuprate and related materials promises to enable flexible design strategies for a range of functionalities, such as magnetoresistance, unconventional superconductivity, ferroelectricity, catalysis, and ion transport.
Printing electronics has led to application areas which were formerly impossible with conventional electronic processes. Solutions are used as inks on top of large areas at room temperatures, allowing the production of fully flexible circuitry. Commonly, research in these inks have focused on organic and metal-oxide ink materials due to their printability, while these materials lack in the electronic performance when compared to silicon electronics. Silicon electronics, on the other hand, has only recently found their way in solution processes. Printing of cyclopentasilane as the silicon ink has been conducted and devices with far superior electric performance have been made when compared to other ink materials. A thermal annealing step of this material, however, was necessary, which prevented its usage on inexpensive substrates with a limited thermal budget. In this work, we introduce a method that allows polycrystalline silicon (poly-Si) production directly from the same liquid silicon ink using excimer laser irradiation. In this way, poly-Si could be formed directly on top of paper even with a single laser pulse. Using this method, poly-Si transistors were created at a maximum temperature of only 150 °C. This method allows silicon device formation on inexpensive, temperature sensitive substrates such as polyethylene terephthalate, polyethylene naphthalate or paper, which leads to applications that require low-cost but high-speed electronics.
Understanding the impacts caused by injection of large volumes of CO 2 in the deep subsurface necessitates a comprehensive monitoring strategy. While surface-based and other remote geophysical methods can provide information on the general morphology of a CO 2 plume, verification of the geochemical conditions and validation of the remote sensing data requires measurements from boreholes that penetrate the storage formation. Unfortunately, the high cost of drilling deep wellbores and deploying instrumentation systems constrains the number of dedicated monitoring borings as well as limits the technologies that can be incorporated in a borehole completion. The objective of the Modular Borehole Monitoring (MBM) Program was to develop a robust suite of well-based tools optimized for subsurface monitoring of CO 2 that could meet the needs of a comprehensive well-based monitoring program. It should have enough flexibility to be easily reconfigured for various reservoir geometries and geologies. The MBM Program sought to provide storage operators with a turn-key fully engineered design that incorporated key technologies, function over the decades long time-span necessary for post-closure reservoir monitoring, and meet industry acceptable risk profiles for deep-well installations. While still within the conceptual design phase of the MBM program, the SECARB Anthropogenic Test in Citronelle, Alabama, USA was identified as a deployment site for our engineered monitoring systems. The initial step in designing the Citronelle MBM system was to down-select from the various monitoring tools available to include technologies that we considered essential to any program. Monitoring methods selected included U-tube geochemical sampling, discrete quartz pressure and temperature gauges, an integrated fibre-optic bundle consisting of distributed temperature and heat-pulse sensing, and a sparse string of conventional 3C-geophones. While not originally planned within the initial MBM work scope, the fibre-optic cable was able to also be used for the emergent technology of distributed acoustic sensing. The MBM monitoring string was installed in March, 2012. To date, the Citronelle MBM instruments continue to operate reliably. Results and lessons learned from the Citronelle MBM deployment are addressed along with examples of data being collected.