Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Choke Flange for High Power RF Components Excited by TE01 Mode

A multifaceted program to study high gradient structures and properties of RF breakdown is under way at SLAC. This program includes testing of simplified versions of traveling wave and standing wave structures at 11.4 GHz. [Dolgashev] RF power is fed into these structures using a TE01 mode-launcher. An RF flange is used to connect the mode-launcher to the test-structure. The rf currents flow through either the stainless steel lip on the flange or, in an alternate assembly, through a copper gasket pressed between the same stainless steel lips. In a recent experiment with a single cell traveling wave structure, a flange with stainless steel lips was irreversibly damaged at RF power about 90 MW and {approx}100 ns pulse length. We suggest an alternative flange that does not rely on metal-to-metal contact in the rf power transfer region. The idea is to use an asymmetric choke flange, where the choke grove is cut into a conflate flange on the mode-launcher. The structures themselves will have a simpler, flat conflate flange with rounded corners on the vacuum side. The Vacuum seal is achieved with a Cu gasket between these two flanges above the RF region. We have designed a flange with a choke which is almost field free in the vacuum gasket region, whose technical specifications and RF properties are presented below. Design simulations were conducted using HFSS, a 3D finite element code that solves electromagnetic fields in complex structures. Figure 1 demonstrates the projected physical look of the choke flange, while the table next to it lists the critical parameters. The maximum electric field for in this geometry is on axis at 33.6MV/m for 100 MW input. The electric field near the gasket, meaning at the top of the choke gap is at 125kV/m or 1.25kV/cm. Figure 2 demonstrates the electric field strength profile in the geometry for 100 MW input power. The maximum magnetic field for in this geometry is near the pipe at 59kA/m for 100 MW input. The magnetic field at the gasket at the top of the choke gap is at 225A/m or 2.25/cm. Figure 3 demonstrates the magnetic field strength profile in the geometry for 100MW input power.

36 MATERIALS SCIENCE↗

Diaphragm flange and method for lowering particle beam impedance at connected beam tubes of a particle accelerator

A diaphragm flange for connecting the tubes in a particle accelerator while minimizing beamline impedance. The diaphragm flange includes an outer flange and a thin diaphragm integral with the outer flange. Bolt holes in the outer flange provide a means for bolting the diaphragm flange to an adjacent flange or beam tube having a mating bolt-hole pattern. The diaphragm flange includes a first surface for connection to the tube of a particle accelerator beamline and a second surface for connection to a CF flange. The second surface includes a recessed surface therein and a knife-edge on the recessed surface. The diaphragm includes a thickness that enables flexing of the integral diaphragm during assembly of beamline components. The knife-edge enables compression of a soft metal gasket to provide a leak-tight seal.

43 PARTICLE ACCELERATORS↗

System for sealing flanged connections

A flange sealing system can include a loading member layer adapted to receive a sealing force thereon, at least one intermediate member receiving the sealing force from the loading member and adapted to distribute the load force to branch members in subsequent layers, and at least one contact member adapted to apply the sealing force evenly around a flange and press a surface of the flange and against at least one of a second flange surface or a cap to seal an opening associated with the flange via at least one of connection to the second flange surface or the cap. The system can be provided in the form of a first pipe receiving section and a second pipe receiving section for securing two flanges together with associated pipes with pivot points distributed about the first and second pipe receiving section and distributing even pressure around the flanges.

Baffes, Curtis M.↗

Magnetic Resonance Imaging (MRI) Markers for MRI-Guided High-Dose-Rate Brachytherapy: Novel Marker-Flange for Cervical Cancer and Marker Catheters for Prostate Cancer

Purpose: To present a novel marker-flange, addressing source-reconstruction uncertainties due to the artifacts of a titanium intracavitary applicator used for magnetic resonance imaging (MRI)-guided high-dose-rate (HDR) brachytherapy (BT); and to evaluate 7 different MRI marker agents used for interstitial prostate BT and intracavitary gynecologic HDR BT when treatment plans are guided by MRI. Methods and Materials: Seven MRI marker agents were analyzed: saline solution, Conray-60, copper sulfate (CuSO{sub 4}) (1.5 g/L), liquid vitamin E, fish oil, 1% agarose gel (1 g agarose powder per 100 mL distilled water), and a cobalt–chloride complex contrast (C4) (CoCl{sub 2}/glycine = 4:1). A plastic, ring-shaped marker-flange was designed and tested on both titanium and plastic applicators. Three separate phantoms were designed to test the marker-flange, interstitial catheters for prostate BT, and intracavitary catheters for gynecologic HDR BT. T1- and T2-weighted MRI were analyzed for all markers in each phantom and quantified as percentages compared with a 3% agarose gel background. The geometric accuracy of the MR signal for the marker-flange was measured using an MRI-CT fusion. Results: The CuSO{sub 4} and C4 markers on T1-weighted MRI and saline on T2-weighted MRI showed the highest signals. The marker-flange showed hyper-signals of >500% with CuSO{sub 4} and C4 on T1-weighted MRI and of >400% with saline on T2-weighted MRI on titanium applicators. On T1-weighted MRI, the MRI signal inaccuracies of marker-flanges were measured <2 mm, regardless of marker agents, and that of CuSO{sub 4} was 0.42 ± 0.14 mm. Conclusion: The use of interstitial/intracavitary markers for MRI-guided prostate/gynecologic BT was observed to be feasible, providing accurate source pathway reconstruction. The novel marker-flange can produce extremely intense, accurate signals, demonstrating its feasibility for gynecologic HDR BT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compact raised face flange

In an example, a raised face flange assembly, comprises an upper flange to couple to a lower flange using one or more bolts: wherein the upper flange or the lower flange comprises: a bolting face defining one or more openings for the one or more bolts, respectively; a pair of raised faces including a first raised face and a second raised face to make contact with a mating surface of the other of the upper flange or the lower flange; wherein a distance between an area of the second raised face and a plane corresponding to the bolting face is greater than a distance between an area of the first raised face and the plane to distribute contact force with a mating surface over the area of the second raised face to maintain a seal.

Liszkai, Tamas↗

Hydroforming of flanged tubular part

Tube hydroforming is the technology that utilizes hydraulic pressure to form a tube into desired shapes inside die cavities. Recently, tube hydroforming technology draws attentions of automotive industries due to its advantages such as weight reduction, increased strength, improved quality and reduced tooling cost. Hydroformed automotive parts used as structural components in vehicle body frame or subframe often have to be structurally joined at some point. Therefore it is useful if the hydroformed automotive parts can be given a localized attachment flange. In this study, a tube hydroformed product which has flange has been formed at various processing conditions. To accomplish successful flange hydroforming process, thorough investigation on proper combination of process parameters such as internal hydraulic pressure and tool geometry has been performed. For the process design FE analysis was performed with Dynaform 5.5. With optimized die parting angle and circumferential expansion ratio, hydroforming experiments to form flange were performed and forming characteristics at various process conditions were analyzed. The results show that flanged parts can be successfully produced by tube hydroforming process.

36 MATERIALS SCIENCE↗

Flange joint system for SRF cavities utilizing high force spring clamps for low particle generation

A flange joint system for SRF cavities. The flange joint system includes a set of high force spring clamps that produce high force on the simple flanges of Superconducting Radio Frequency (SRF) cavities to squeeze conventional metallic seals. The system establishes the required vacuum and RF-tight seal with minimum particle contamination to the inside of the cavity assembly. The spring clamps are designed to stay within their elastic range while being forced open enough to mount over the flange pair. Upon release, the clamps have enough force to plastically deform metallic seal surfaces and continue to a new equilibrium sprung dimension where the flanges remain held against one another with enough preload such that normal handling will not break the seal.

42 ENGINEERING↗

Dual-wall integrated flange joint

A dual-wall integrated flange joint is provided. The integrated flange joint includes an inner wall having at least one inlet and at least one outlet, a flange extending radially outward from the inlet of the inner wall, and a collar extending from the flange in the direction of the inner wall and surrounding at least a portion of the inner wall. The integrated flange joint is formed of a single piece of material. Also, the collar at least partially defines an outer wall, and a volume between the collar and the inner wall at least partially defines an airgap.

Hoye, Robert F.↗

Agile Acceleration of LLVM Flang Support for Fortran 2018 Parallel Programming

The LLVM Flang compiler ("Flang") is currently Fortran 95 compliant, and the frontend can parse Fortran 2018. However, Flang does not have a comprehensive 2018 test suite and does not fully implement the static semantics of the 2018 standard. We are investigating whether agile software development techniques, such as pair programming and test-driven development (TDD), can help Flang to rapidly progress to Fortran 2018 compliance. Because of the paramount importance of parallelism in high-performance computing, we are focusing on Fortran’s parallel features, commonly denoted “Coarray Fortran.” We are developing what we believe are the first exhaustive, open-source tests for the static semantics of Fortran 2018 parallel features, and contributing them to the LLVM project. A related effort involves writing runtime tests for parallel 2018 features and supporting those tests by developing a new parallel runtime library: the CoArray Fortran Framework of Efficient Interfaces to Network Environments (Caffeine).

Rasmussen, Katherine↗

THE USE OF KF STYLE FLANGES IN LOW PARTICULATE APPLICATIONS

As SCRF particle accelerator technology advances the need for “low particulate” and “particle free” vacuum sys-tems becomes greater and greater. In the course of the op-eration of these systems, there comes a time when various instruments have to be temporarily attached for diagnostic purposes: RGAs, leak detectors, and additional pumps. In an effort to make the additions of these instruments easier and more time effective, we propose to use KF style flanges for these types of temporary diagnostic connec-tions. This document will describe the tests used to com-pare the particles generated using the assembly of the, widely accepted for “particle free” use, conflat flange to the proposed KF style flange, and demonstrate that KF flanges produce comparable or even less particles

43 PARTICLE ACCELERATORS↗

Vacuum sealing flange

Flange technologies are described for a flange comprising a first and second side. Each side may include a knife edge surface disposed circumferentially around a base surface and a periphery section disposed around the knife edge surface. The knife edge surface and the periphery section are effective to define grooves therebetween. The flange may include an alloy with a relatively high thermal conductivity and yield strength. The flange may include water channels to remove heat.

Sharma, Sushil Kumar↗

Method and apparatus for double-sided incremental flanging

Flanges formed on sheet metal parts to increase the part stiffness or create mating surface for further assembly are created in an incremental sheet forming process using forming tool and supporting tool that move along a specified tool path so as to gradually deform a peripherally-clamped sheet metal work piece into the desired geometry. With two universal tools moving along the designed toolpath on the both sides of the part, the process is very flexible. Process time is can also be reduced by utilizing an accumulative double-sided incremental hole-flanging strategy, in which the flange is formed in only one step.

Zhang, Huan↗

Method and apparatus for double-sided incremental flanging

Flanges formed on sheet metal parts to increase the part stiffness or create mating surface for further assembly are created in an incremental sheet forming process using forming tool and supporting tool that move along a specified tool path so as to gradually deform a peripherally-clamped sheet metal work piece into the desired geometry. With two universal tools moving along the designed toolpath on the both sides of the part, the process is very flexible. Process time is can also be reduced by utilizing an accumulative double-sided incremental hole-flanging strategy, in which the flange is formed in only one step.

Zhang, Huan↗

Evaluation of LLVM Flang for Production HPC Applications and Modern Fortran Features

In 2025, LLVM released its first Flang Fortran compiler version considered ready for widespread evaluation. We know of no published assessment of Flang compiling a workload- derived portfolio of high-performance computing (HPC) applications. We address this gap using workload data from the National Energy Research Scientific Computing Center (NERSC), which supports more than 10,000 scientists on approximately 1,000 projects. The NERSC workload analyses identify many Fortran components in heavily used applications. We selected 10 such packages with available source code. We compiled them with Flang 22.1.3 on NERSC’s Perlmutter system. Six compiled without code modifications, though some required build-system changes. Three compiled after minor source edits, mostly to address Fortran standard violations. One built only without OpenMP enabled. We evaluated seven additional packages selected for their use of, or enablement of, standard Fortran parallel features: multi-image execution and do concurrent. Six such codes compiled with most or all unit tests passing.

Rasmussen, Katherine↗

A Flang Plugin for Fortran Feature Characterization

As new compute systems are developed, there is still a need to compile and execute codes authored in Fortran on these leading edge systems. In order to achieve this, development of compilers that support the latest hardware is continuously under development. Though the specification of Fortran is extensive, it is helpful to compiler authors to be able to prioritize the development of key features in order to get certain codes deemed important, e.g., applications of interest to leadership computing facilities, executable on leading edge compute systems. Identifying key features though is largely done through querying software experts or users of the Fortran applications of interest, who then manually report what features are and are not present. This exercise can both time consuming and error prone. To automate this process, we present a compiler plugin to Flang, the Fortran frontend for LLVM. This plugin is a tool that operates on the parse tree representation generated by Flang and detects key features based on walking parse tree nodes that correspond to features of interest. We show the result of our tool on four applications, three of which were manually profiled by software experts. We show the discrepancies between our tool and the manual characterization of the three applications, as well as generate a characterization for an application not yet profiled. We intend to open-source our tool in order to invite the community to benefit from the tool and make contributions for other features.

Cabrera, Anthony [ORNL]↗

RF Choke for Standing Wave Structures and Flanges

SLAC participates in the U.S. High Gradient collaboration whose charter includes basic studies of rf breakdown properties in accelerating structures. These studies include experiments with different materials and construction methods for single cell standing wave accelerating structures. The most commonly used method of joining cells of such structures is the high temperature bonding and/or brazing in hydrogen and/or vacuum. These high temperature processes may not be suitable for some of the new materials that are under consideration. We propose to build structures from cells with an rf choke, taking the cell-to-cell junction out of the electromagnetic field region. These cells may be clamped together in a vacuum enclosure, the choke joint ensuring continuity of rf currents. Next, we propose a structure with a choke joint in a high gradient cell and a view port which may allow us microscopic, in-situ observation of the metal surface during high power tests. And third, we describe the design of a TM01 choke flange for these structures.

08 HYDROGEN↗

Nitrile O-ring Cracking: A Case of Vacuum Flange O-ring Failures

A review of recent nitrile O-ring failures in ISO-KF vacuum flange connections in glovebox applications is presented. An investigation of a single “isolated” o-ring failure leads to the discovery of cracked nitrile o-rings in a glovebox atmospheric control unit. The initial cause of the o-ring failure is attributed to ozone degradation. However, additional investigation reveals nitrile o-ring cracking on multiple gloveboxes and general purpose piping, roughly 85% of the nitrile o-rings removed for inspection show evidence of visible cracking after being in service for 18 months or less. The results of material testing and ambient air testing is presented, elevated ozone levels are not found. The contributing factors of o-ring failure, including nitrile air sensitivity, inadequate storage practices, and poor installation techniques, are discussed. A discussion of nitrile o-ring material properties, the benefits and limitations, and alternate materials are discussed. Considerations for o-ring material selection, purchasing, storage, and installation are presented in the context of lessons learned from the nitrile o-ring cracking investigation. This paper can be presented in 20 minutes and does not require special accommodations or special audio visual devices.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Lowering and Runtime Support for Fortran’s Multi-Image Parallel Features using LLVM Flang, PRIF, and Caffeine

This paper provides an overview of the multi-image parallel features in Fortran 2023 and their implementation in the LLVM flang compiler and the Caffeine parallel runtime library. The features of interest support a Single-Program, Multiple-Data (SPMD) programming model based on executing multiple “images”, each of which is a program instance. The features also support a Partitioned Global Address Space (PGAS) in the form of “coarray” distributed data structures. The paper discusses the lowering of multi-image features to the Parallel Runtime Interface for Fortran (PRIF) and the implementation of PRIF in the Caffeine parallel runtime library. This paper also provides an early view into the design of a new multi-image dialect of the LLVM Multi-Level Intermediate Representation (MLIR). We describe validation and testing of the resulting software stack, and demonstrate that performance compares favorably to another open-source compiler and runtime library: GNU Compiler Collection (GCC) gfortran and OpenCoarrays, respectively.

Bonachea, Dan↗