Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Performance Evaluation of AG-1 FC Filters Under Upset Conditions and the Effects of Aging on Filters - 19501

High efficiency particulate air (HEPA) filters are routinely used in nearly every operating Department of Energy (DOE) and National Nuclear Safety Administration (NNSA) nuclear facility. These nuclear grade HEPA filters installed in DOE and NNSA confinement ventilation systems are credited as the final barrier to protect the environment, the public, and the worker from accidental release of virtually all airborne radioactive materials, and must meet the American Society of Mechanical Engineers' (ASME) Code on Nuclear Air and Gas Treatment (CONAGT) AG-1 standard. This testing activity evaluates ASME AG-1 Section FC axial flow HEPA filters, both separator and separator-less, under upset conditions. Additionally, testing efforts have analyzed the effects of filter degradation due to aging. In 1997, the Defense Nuclear Facilities Safety Board (DNFSB) raised concerns of the potential vulnerability of HEPA filters in vital safety systems, both from a design stand point and the potential for degradation of HEPA filter performance over time. The DOE Office of Environmental Management (DOE-EM) has a Cooperative Agreement with Mississippi State University (MSU) Institute for Clean Energy Technology (ICET) to conduct testing of HEPA filters. DOE-EM has established a Technical Working Group (TWG) of over thirty subject matter experts from the nuclear industry to provide input and oversight of ICET projects and activities. This has included establishment/approval of testing parameters for evaluating these filters under ASME NQA-1 compliant Test Plans. The current scope of work involves evaluation of the performance envelope for new and aged separator and separator-less designs of AG-1 Section FC axial flow HEPA filters. A range of elevated test conditions (T and RH) are used to determine the operating envelope within which DOE nuclear safety experts can credit installed HEPA filter performance, thereby establishing a risk-informed DOE service life. This paper will present preliminary test results of new and aged axial flow filters tested at ICET. Results in this paper include data collected from new separator and separator-less type FC HEPA filters and equivalent test data for a limited group of aged separator and separator-less type FC HEPA filters. Testing for both scopes of work evaluate initial filter performance under ambient conditions of temperature (60 deg. F - 80 deg. F (∼16 - ∼27 deg. C)) and relative humidity (40-60%), loading of each filter with Aluminum Trihydroxide, Al(OH)3, to a specified differential pressure, and then exposing the filter to specified elevated temperature and relative humidity conditions. In addition to the upset conditions of elevated temperature and relative humidity, the performance of HEPA filters under fire scenarios is not well characterized. ICET is currently designing a burn box and testing apparatus to study the effects of fire from burning liquids and a wide range of blends of combustible solids. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stacked filters: learning to filter by structure

We present Stacked Filters, a new probabilistic filter which is fast and robust similar to query-agnostic filters (such as Bloom and Cuckoo filters), and at the same time brings low false positive rates and sizes similar to classifier-based filters (such as Learned Filters). The core idea is that Stacked Filters incorporate workload knowledge about frequently queried non-existing values. Instead of learning, they structurally incorporate that knowledge using hashing and several sequenced filter layers, indexing both data and frequent negatives. Stacked Filters can also gather workload knowledge on-the-fly and adaptively build the filter. We show experimentally that for a given memory budget, Stacked Filters achieve end-to-end query throughput up to 130x better than the best alternative for a workload, either query-agnostic or classifier-based filters, and depending on where data is (SSD or HDD).

Computer Science↗

Prototype Ceramic HEPA Filter Testing and Filter Media Research and Development for Nuclear Facility Ventilation

This is a brief summary of recent and past Ceramic HEPA Filter research and development activities under an NNSA NSR&D funded project and describes on-going plans for FY19 work as presently planned. Prior work has evaluated concepts for a ceramic HEPA filter including ceramic support materials, filter media including electrospun filter media, and metal housing designs to accommodate the conservative temperature performance target of up to 500°C. This has been supported by modelling efforts discussed with nuclear facility system engineers and their management. The temperature and time-at-temperature are based on conservative, bounding temperatures from fire analysis presented as an EFCOG best practice paper for nuclear facility safety analysis. The overall goal is to improve safety of DOE nuclear facilities during fire scenarios by developing improved filtration technology including increasing temperature performance while maintaining acceptable filter pressure drop. Ceramic filtration technology can provide robust, passive mitigation against radiological releases. The goal of the ceramic HEPA filter is to provide a HEPA filter that provides increased temperature performance in an equivalent form factor (size and shape) that is similar to existing conventional HEPA filters used in facilities. Once development is complete and qualified for use in facilities, ceramic HEPA filters could simplify and reduce safety and support system costs, as well as lower life-cycle costs. Installation, monitoring, and maintenance of active fire suppression systems, as well as other related systems, are a considerable on-going cost to nuclear facilities. Reducing the level of dependence on Safety Class and Safety Significant fire alarm and fire suppression systems could allow significant cost savings, while maintaining safety. At present we are continuing research and development efforts towards the goal of a ceramic filter design, including improved ceramic filter media, that could reduce total operation cost for facilities utilizing HEPA filters.

36 MATERIALS SCIENCE↗

The Simulation and Design of an On-Chip Superconducting Millimetre Filter-Bank Spectrometer

Abstract Superconducting on-chip filter banks provide a scalable, space saving solution to create imaging spectrometers at millimetre and submillimetre wavelengths. We present an easy to realise, lithographed superconducting filter design with a high tolerance to fabrication error. Using a capacitively coupled $$\lambda /2$$ λ / 2 microstrip resonator to define a narrow ( $$\lambda /\Delta \lambda = 300$$ λ / Δ λ = 300 ) spectral pass band, the filtered output of a given spectrometer channel directly connects to a lumped-element kinetic inductance detector. We show the tolerance analysis of our design, demonstrating $$<11\%$$ < 11 % change in filter quality factor to any one realistic fabrication error and a full filter-bank efficiency forecast to be 50% after accounting for fabrication errors and dielectric loss tangent.

Robson, G. (ORCID:0000000315279326)↗

Spectral shaping of an ultrafast ytterbium fiber laser via a passive intracavity optical filter: a simple and reliable route to sub-45 fs pulses

We investigate the use of passive intracavity optical filters for controlling the laser output spectrum of a polarization-mode-locked, ultrafast ytterbium fiber laser. The overall lasing bandwidth is increased or extended by strategic choice of the filter cutoff frequency. Overall laser performance, including pulse compression and intensity noise, is investigated for both shortpass and longpass filters with a range of cutoff frequencies. The intracavity filter not only shapes the output spectra, but also provides a route for overall broader bandwidths and shorter pulses in ytterbium fiber lasers. These results demonstrate that spectral shaping with a passive filter is a useful tool to routinely achieve sub-45 fs pulse durations in ytterbium fiber lasers.

Cooper, Nicholas D.↗

Technical analysis of filter testing at the U.S. Department of Energy Filter Test Facility

The U.S. Department of Energy (DOE) technical standard DOE-STD-3020-2015 requires verification testing at the Filter Test Facility (FTF) of high-efficiency particulate air (HEPA) filters to be installed in nuclear facility (Hazard Category 1, 2, 3, and radiological facilities) confinement ventilation systems, or to be installed in habitability systems (e.g., filters for protection of workers required to act for the control and mitigation of emergency situations). Filters in these applications perform a safety function in accident situations, are designated as important to safety, or are necessary for habitability systems. Different FTFs have operated for decades, and results of tests are available to examine the need for and benefits of continued execution of 100 percent QA verification testing. The objective of this study and resulting report was to assess the need for 100 percent QA testing at the current FTF in Maryland, based on an examination of a database of test results from 2013 to August 2020. Filters that require independent testing per DOE-STD-3020-2015 to be installed in nuclear facilities are sent to the FTF before being shipped to the facilities. The FTF examines the documentation (e.g., certificates of compliance, results of particle penetration and airflow resistance testing by the manufacturers, labels affixed to filters and packages, and other requirements specified in purchase orders by the nuclear facility operators), implements visual inspections of the physical state of the filters, and checks the dimensions of frames. Filters that meet the documentation and visual inspection requirements are subjected to particle penetration and airflow resistance testing. In case of rejections, the filters are shipped back to the manufacturers, at the cost of the manufacturers, for replacement. Filters that pass all tests are shipped to the nuclear facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Irradiation-Induced Filter Heating on Calibration of NIR-Longpass-Filtered Reference Solar Cells

Reference solar cells play a crucial role in determining the performance of photovoltaic (PV) devices. In the performance calibration chain of mainstream single-junction PV technologies, common reference cell types include Si, KG-filtered Si, and GaAs cells. For emerging multijunction (MJ) PV technologies, such as CdTe/Si and perovskite/Si, Si reference cells with colored glass near-infrared-longpass (LP) filters like Schott RG-715 and 850 glass have been proposed. They offer a better spectral response that matches the bottom junctions of the emerging MJs, which could lead to lower uncertainties in performance measurements. However, this article reveals a prominent decrease in short-circuit current (ISC) during National Renewable Energy Laboratory's primary calibration over the course of minutes when using this type of LP-filtered reference cell, which could result in unacceptable measurement errors. Unlike quartz or KG filter glasses, LP colored glass filters demonstrate temperature-sensitive cut-on wavelength. When incident irradiance reaches these LP-filtered reference cells, the increased temperature due to light absorption causes a shift of the cut-on to longer wavelength. As a result, the device I SC exhibits a continuous decrease (approximately a 2.5% drop with RG850 LP filter in a 5-min duration) even when the device temperature is controlled at 25 degrees C. To address the temperature gradient issue between colored glass LP filter and the reference cell, we propose the direct integration of thin-film LP semiconductor layer on reference cells. This type of LP-filter-integrated cell has shown minimal temperature-related I SC variation and can serve as a more reliable reference cell source for accurate performance measurements.

14 SOLAR ENERGY↗

Design of optical/IR blocking filters for the Lynx X-ray Microcalorimeter [Design of optical/IR blocking filters for the Lynx S-ray Microcalorimeter (LXM)]

The Lynx mission concept, under development ahead of the 2020 Astrophysics Decadal Review, includes the Lynx X-ray Microcalorimeter (LXM) as one of its main instruments. The LXM uses a microcalorimeter array at the focus of a high-throughput soft x-ray telescope to enable high-resolution nondispersive spectroscopy in the soft x-ray waveband (0.2 to 15 keV) with exquisite angular resolution. Similar to other x-ray microcalorimeters, the LXM uses a set of blocking filters mounted within the dewar that pass the photons of interest (x-rays) while attenuating the out-of-band long-wavelength radiation. Such filters have been successfully used on previous orbital and suborbital instruments; yet, the Lynx science objectives, which emphasize observations in the soft x-ray band (<1 keV), pose more challenging requirements on the set of LXM blocking filters. We present an introduction to the design of the LXM optical/IR blocking filters and discuss recent advances in filter capability targeted at LXM. In addition, we briefly describe the external filters and the modulated x-ray sources to be used for onboard detector calibration.

79 ASTRONOMY AND ASTROPHYSICS↗

Filter 'Cook-Off': Filter Selection via Side-by-Side Testing at Actual Process Conditions - 20040

In 2005, the THOR steam reforming fluidized-bed reactor technology was selected by the U.S. Department of Energy for treatment of sodium-bearing waste at the INL. During the final phase of commissioning prior to radiological operations, regeneration of the high temperature filters in the process gas filter (PGF) vessel became ineffective. After approximately 50 days of testing, the differential pressure across the filters began increasing exponentially and the plant had to be shutdown. Subsequent investigation revealed that the Inconel 625 (I625) sintered metal filter media was corroding in the 550 deg. C reducing environment. A pilot plant run tested four candidate replacement filter media. The top candidate was further tested during a long-term pilot plant run to validate the selection. Data from the testing indicate the selected filters will provide reliable service throughout the life of the project, including after in-situ radiological decontamination. This paper presents the data from this effort and reinforces the value of pilot plant testing. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improved filters for angular filter refractometry

Angular filter refractometry is an optical diagnostic that measures the absolute contours of a line-integrated density gradient by placing a filter with alternating opaque and transparent zones in the focal plane of a probe beam, which produce corresponding alternating light and dark regions in the image plane. Identifying transitions between these regions with specific zones on the angular filter (AF) allows the line-integrated density to be determined, but the sign of the density gradient at each transition is degenerate and must be broken using other information about the object plasma. Additional features from diffraction in the filter plane often complicate data analysis. Here, in this paper, we present an improved AF design that uses a stochastic pixel pattern with a sinusoidal radial profile to minimize unwanted diffraction effects in the image caused by the sharp edges of the filter bands. We also present a technique in which a pair of AFs with different patterns on two branches of the same probe beam can be used to break the density gradient degeneracy. Both techniques are demonstrated using a synthetic diagnostic and data collected on the OMEGA EP (extended performance) laser.

47 OTHER INSTRUMENTATION↗

Filtered Backprojection in Compton Imaging using a Spherical Harmonic Wiener Filter with Pixelated CdZnTe

Filtered backprojection is an image reconstruction technique for Compton imaging that provides reasonably high resolution at much lower computational costs when compared to iterative methods. Here, this work applies a Wiener filter that has been derived for spherical harmonics on Compton imaging using the OrionUM pixelated CdZnTe imaging-spectrometer. To regularize the filter, an investigation is made into the power spectral density of the signal and noise to develop an appropriate spectral signal-to-noise ratio model for the restoration process. Experimental measurements were conducted with two 228Th sources placed 30° apart. The resulting filtered image of the two sources have an average full-width-at-half-maximum (FWHM) of 9.8° or 7.5° when using a mean squared error and structural similarity optimization approach respectively; an improvement from the 29.0° FWHM image when using simple backprojection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extraction of Tumor Site from Cancer Pathology Reports using Deep Filters

Purpose: Pathology reports are the primary source of information concerning the millions of cancer cases across the United States. Cancer registries manually process the pathology reports to extract the pertinent information including primary tumor site, behavior, histology, laterality, and grade. Processing a large volume of the pathology reports in a timely manner is a continuing challenge for cancer registries. The purpose of this study is to develop an information extraction pipeline to reliably and efficiently extract reportable information. Method: We have developed a novel inverse-regression (IR) based information extraction pipeline. The inverse-regression based supervised filter has been successfully applied to many application domains. However, its application to the information extraction from unstructured text is hindered primarily by the extreme high-dimensionality of n-gram representations of text. In this study, we attempt to overcome the obstacles by a novel bootstrapping strategy. First, we use an information-theoretic mutual information based filter to discard the excessive and redundant n-gram features. This step reduces the size and improves the condition number of the sample covariance matrix, thus reducing the computational cost and improving the numerical stability of the subsequent inverse-regression step. Then we use localized sliced inverse-regression (LSIR) to learn a low-dimensional discriminatory subspace for information inference. In particular, we use the k-nearest neighbors of an unlabeled pathology report in the learned representation to infer the desired information from the labeled data in a supervised manner. Results: The experiments were conducted on a set of de-identified pathology reports with human expert labels as the ground truth. Our pipeline consistently performed better than or comparable to the best performing state-of-the-art methods while reducing the training and inference times substantially. Conclusion: Our results demonstrate the potential of inverse-regression based information extraction pipeline for reliable and efficient information extraction from unstructured text. The information extracted from the pathology reports can be used along with clinical information, medical imaging, and genomic information to instigate discoveries in cancer research.

Dubey, Abhishek↗

On-Sensor Data Filtering using Neuromorphic Computing for High Energy Physics Experiments

This work describes the investigation of neuromorphic computing-based spiking neural network (SNN) models used to filter data from sensor electronics in high energy physics experiments conducted at the High Luminosity Large Hadron Collider. We present our approach for developing a compact neuromorphic model that filters out the sensor data based on the particle's transverse momentum with the goal of reducing the amount of data being sent to the downstream electronics. The incoming charge waveforms are converted to streams of binary-valued events, which are then processed by the SNN. We present our insights on the various system design choices - from data encoding to optimal hyperparameters of the training algorithm - for an accurate and compact SNN optimized for hardware deployment. Our results show that an SNN trained with an evolutionary algorithm and an optimized set of hyperparameters obtains a signal efficiency of about 91% with nearly half as many parameters as a deep neural network.

R. Kulkarni, Shruti↗

Filter Test System for Nuclear Container Filters

The purpose of this procedure is to measure the collection efficiency of the filters that are integrated into the lids of containers for nuclear material at Los Alamos National Laboratory (LANL). As an application of this procedure, a filter test report certificate can be created to document the measurement process. This procedure is intended to describe the TA-55, PF-4 (room 6A) operation of a Filter Test System (FTS) for Hagan and SAVY storage containers.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A portable and monoenergetic 24 keV neutron source based on 124Sb-9Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the 124Sb-9Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from 124Sb decays while letting through the neutrons. To increase the 124Sb activity and thus the neutron flux, a >1 GBq 124Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20–25 keV to be 6.00±0.30 neutrons per cm2 per second and the total gamma flux to be 245±8 gammas per cm2 per second (numbers scaled to 1 GBq activity of the 124Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

Dark Matter detectors (WIMPs, axions, etc.)↗

Quantitative 2D thermometry in turbulent sooting non-premixed flames using filtered Rayleigh scattering

This paper demonstrates the application of a thermometry method in turbulent sooting non-premixed flames using filtered Rayleigh scattering (FRS). Fuel tailoring is used to establish a specific C 2 H 2 -based fuel mixture such that temperature can be determined accurately by a single FRS measurement over the entirety of mixture fraction space, or equivalently, for all relevant thermo-chemical states. Evaluation is performed in a hierarchy of flows to establish measurement precision and accuracy. Initial assessments in a series of heated fuel mixtures; non-sooting, near-adiabatic flat flames; and laminar non-premixed sooting flames show accuracy of the approach over a full range of expected temperatures and high single-shot measurement precision (e.g., 65 < <#comment/> S N R < <#comment/> 80 ) for temperatures between 1900 and 2200 K. Subsequently, 2D temperature measurements are evaluated in a turbulent non-premixed sooting flame. For the current fuel mixture, the local mixture-averaged Rayleigh scattering cross section is nearly constant over all composition space, and thus traditional laser Rayleigh scattering (LRS) is used as a measurement standard in the absence of soot. The results show excellent agreement between the proposed FRS thermometry approach and LRS in non-sooting regions. In the presence of soot, the proposed FRS-based approach shows no signs of interference. In addition, 2D temperature imaging shows high SNR (60–74) over all temperature conditions. Thus, we believe the proposed methodology successfully provides a high-resolution 2D temperature method under turbulent sooting flame conditions.

Pu, Jinpeng↗