Fermi-surface structure and field ionization.
Field ionization at metal surfaces as rearrangement collision, considering anisotropic electron tunneling probabilities produced by Fermi surface
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Field ionization at metal surfaces as rearrangement collision, considering anisotropic electron tunneling probabilities produced by Fermi surface
Field ionization as a means to create ions for compact and rugged neutron sources is pursued. Arrays of carbon nano-fibers promise the high field-enhancement factors required for efficient field ionization. We report on the fabrication of arrays of field emitters with a density up to 10{sup 6} tips/cm{sup 2} and measure their performance characteristics using electron field emission. The critical issue of uniformity is discussed, as are efforts towards coating the nano-fibers to enhance their lifetime and surface properties.
A volcano-style field ionization source was tested with eight different gases: hydrogen, helium, ammonia, methane, argon, neon, water vapor, and hydrogen sulfide. For ammonia, hydrogen sulfide, and water, the ionization efficiency of the field ionization source was determined as a function of the electrical potential difference between the ionizer and its counterelectrode. The ionization efficiencies for the other gases were too low to be measured in the present apparatus. The operating characteristics of a field emission cathode, were studied, in the presence of the same eight gases at pressures up to 0.00001 torr. The presence of the gases caused little or no significant change in the electron emission from the cathodes. Results indicate that the field emission cathode has advantages over electrically heated cathodes as a source of an electron beam in spacecraft mass spectrometers.
A new deuterium ion source is being developed to improve the performance of existing compact neutron generators. The ion source is a microfabricated array of metal tips with an integrated gate (i.e., grid) and produces deuterium ions by field ionizing (or field desorbing) a supply of deuterium gas. Deuterium field ion currents from arrays at source temperatures of 77 K and 293 K are studied. Ion currents from single etched-wire tips operating under the same conditions are used to help understand array results. I-F characteristics of the arrays were found to follow trends similar to those of the better understood single etched-wire tip results; however, the fields achieved by the arrays are limited by electrical breakdown of the structure. Neutron production by field ionization at 293 K was demonstrated for the first time from microfabricated array structures with integrated gates.
The energy deficit of pulsed-laser field-evaporated ions and field-ionized atoms of an inert gas from the surface of a non-metallic nano-metric tip is reported as a function of the laser intensity, ion current, and temperature. A new model is proposed to explain these results, taking into account the resistive properties of non-metallic nano-tips. A good agreement between the theoretical predictions and the experimental results is obtained for all parameters investigated experimentally. This model is also used to discuss the evaporation behavior of oxides analyzed in laser-assisted atom probe tomography. New insight into the contribution of the electrostatic field and the laser illumination on the evaporation process of non-metallic materials is given.
A palm sized, portable neutron source would be useful for widespread implementation of detection systems for shielded, special nuclear material. We present progress towards the development of the components for an ultracompact neutron generator using a pulsed, meso-scale field ionization source, a deuterated (or tritiated) titanium target driven by a negative high voltage lithium tantalate crystal. Neutron production from integrated tests using an ion source with a single, biased tungsten tip and a 3 Multiplication-Sign 1 cm, vacuum insulated crystal with a plastic deuterated target are presented. Component testing of the ion source with a single tip produces up to 3 nA of current. Dielectric insulation of the lithium tantalate crystals appears to reduce flashover, which should improve the robustness. The field emission losses from a 3 cm diameter crystal with a plastic target and 6 cm diameter crystal with a metal target are compared.
Strong-field ionization provides fundamental insight into light-matter interactions, encoding the structure of atoms and molecules on the subångström and subfemtosecond scales. Here, we explore an important regime: strong-field ionization by two-color circularly polarized laser fields. In contrast to past work using linearly polarized drivers, we probe electron trajectories that are driven in a two-dimensional plane, thus separating the tunneling angle from the rescattering angle. This allows us to make several findings. First, we observe a single-lobed electron distribution for co-rotating fields, and a three-lobed distribution for counter-rotating fields, providing experimental validation of the theoretical model explaining the generation of circularly polarized high harmonic light. Second, we discover that there is significant electron-ion rescattering using counter-rotating fields, but not with co-rotating fields. Finally, we show that the rescattered electrons are well separated from the directly ionized electrons, in striking contrast to similar low-energy structures seen with linearly polarized fields. These findings help overcome the long-standing problem of how to decouple the tunneling and rescattering steps in strong-field ionization, which will enable new dynamic probes of atomic and molecular structure.
Integrating field ionization models into kinetic plasma simulations is required for a variety of applications, especially when field strengths vary from low to high regimes, such as in laser-target interactions. The introduction of new physics models into kinetic codes requires a rigorous verification of their accuracy through well-defined verification problems. In this work, the field ionization model that has been included in the kinetic plasma code VPIC is presented, along with the detailed approach adopted for its integration. This model includes a comprehensive range of field ionization mechanisms: multiphoton ionization, tunneling ionization, and barrier suppression ionization. New verification problems employed to evaluate the ionization model's fidelity are outlined, and the simulation parameters that affect the accuracy of simulation results are explored. Additionally, this work addresses the impact of field ionization on computational performance.
The field ionization neutral detector FIND operates according to the following principle: Neutral atoms are attracted toward the field ionization tips since they are polarized by the electric field of the tips. The atoms are singly ionized and repelled by the positive potential of the tips toward the detector situated behind a grid at ground potential. The ions deposit in the detector their kinetic energies, typically 26 keV, corresponding to the potential difference between the ionization region and the detector. Laboratory results show that FIND can have the resolution, sensitivities and durability required to perform in situ measurements of neutral H and He fluxes in interplanetary space, cometary halos and exospheres.
Here we present experimental results connecting field ionization to photoionization in Li Rydberg atoms obtained with 17- and 36-GHz microwave fields. At a low principal quantum number n, where the microwave frequency {omega} is much lower than the classical, or Kepler frequency, {omega}{sub K}=1/n{sup 3}, microwave ionization occurs by field ionization, at E=1/9n{sup 4}. When the microwave frequency exceeds the Kepler frequency, {omega}>1/n{sup 3}, the field required for ionization is independent of n and given by E=2.4{omega}{sup 5/3}, in agreement with dynamic localization models, which cross over to a Fermi's Golden Rule approach at the photoionization limit. A surprising aspect of our results is that when {omega}{approx_equal}1/2n{sup 2}, the one- and multiphoton ionization rates are similar, and even at the lowest microwave powers, all are 10 times lower than the perturbation theory rate calculated for single-photon ionization. Further, we show that when the Rydberg atoms are excited in the presence of the microwave field, the probability of an atom's being bound at the end of the microwave pulse passes smoothly across the limit. This microwave stimulated recombination to bound Rydberg states can be well described by a simple classical model. More generally, these results suggest that the problem of a Rydberg atom coupled to a high-frequency microwave field is similar to the problem of interchannel internal coupling in multilimit atoms, a problem well described by quantum defect theory.
A small mass spectrometer utilizing a miniature field ionization source is now undergoing development. It is designed for use in a variety of applications in which there are requirements for a lightweight, low-power-consumption instrument that can analyze the masses of a wide variety of molecules and ions. The device can operate without need for a high-vacuum, carrier-gas feed radioactive ionizing source, or thermal ionizer. This mass spectrometer can operate either in the natural vacuum of outer space or on Earth at any ambient pressure below 50 torr (below about 6.7 kPa) - a partial vacuum that can easily be reached by use of a small sampling pump. This mass spectrometer also has a large dynamic range - from singly charged small gas ions to deoxyribonucleic acid (DNA) fragments larger than 104 atomic mass units - with sensitivity adequate for detecting some molecules and ions at relative abundances of less than one part per billion. This instrument (see figure) includes a field ionizer integrated with a rotating-field mass spectrometer (RFMS). The field ionizer effects ionization of a type characterized as "soft" in the art because it does not fragment molecules or initiate avalanche arcing. What makes the "soft" ionization mode possible is that the distance between the ionizing electrodes is less than mean free path for ions at the maximum anticipated operating pressure, so that the ionizer always operates on the non-breakdown side of the applicable Paschen curve (a standard plot of breakdown potential on the ordinate and pressure electrode separation on the abscissa). The field ionizer in this instrument is fabricated by micromachining a submicron-thick membrane out of an electrically nonconductive substrate, coating the membrane on both sides to form electrodes, then micromachining small holes through the electrodes and membrane. Because of the submicron electrode separation, even a potential of only 1 V applied between the electrodes gives rise to an electric field with a strength of in excess of a megavolt per meter strong enough to ionize any gas molecules passing through the holes. An accelerator grid and an electrostatic deflector focus the ions from the field ionizer into the rotating-field cell of the RFMS. The potentials applied to the electrodes of the cell to generate the rotating electric field typically range from 1 to 13 V. The ions travel in well-defined helices within this cell, after which they are collected in a Faraday cup. The mass of most of the molecules reaching the Faraday cup decreases with increasing frequency of rotation of the electric field in the cell. Therefore, the frequency of rotation of the electric field is made to vary in order to scan through a desired range of ion masses: For example, lightweight gas molecules are scanned at frequencies in the megahertz range, while DNA and other large organic molecules are scanned at kilohertz frequencies.
This work reports on the application of a novel electric field-ionization setup for high-resolution laser spectroscopy measurements on bunched fast atomic beams in a collinear geometry. In combination with multi-step resonant excitation to Rydberg states using pulsed lasers, the field ionization technique demonstrates increased sensitivity for isotope separation and measurement of atomic parameters over previous non-resonant laser ionization methods. The setup was tested at the Collinear Resonance Ionization Spectroscopy experiment at ISOLDE-CERN to perform high-resolution measurements of transitions in the indium atom from the 5s 2 5d 2 D 5/2 and 5s 2 5d 2 D 3/2 states to 5s 2 np 2 P and 5s 2 nf 2 F Rydberg states, up to a principal quantum number of n=72 . The extracted Rydberg level energies were used to re-evaluate the ionization potential of the indium atom to be 46,670.107(4)cm -1 . The nuclear magnetic dipole and nuclear electric quadrupole hyperfine structure constants and level isotope shifts of the 5s 2 5d 2 D 5/2 and 5s 2 5d 2 D 3/2 states were determined for 113,115 In. The results are compared to calculations using relativistic coupled-cluster theory. A good agreement is found with the ionization potential and isotope shifts, while disagreement of hyperfine structure constants indicates an increased importance of electron correlations in these excited atomic states. With the aim of further increasing the detection sensitivity for measurements on exotic isotopes, a systematic study of the field-ionization arrangement implemented in the work was performed at the same time and an improved design was simulated and is presented. The improved design offers increased background suppression independent of the distance from field ionization to ion detection.
We demonstrate an atom detector based on field ionization and subsequent ion counting. We make use of field enhancement near tips of carbon nanotubes to reach extreme electrostatic field values of up to 9x10{sup 9} V/m, which ionize ground-state rubidium atoms. The detector is based on a carpet of multiwall carbon nanotubes grown on a substrate and used for field ionization, and a channel electron multiplier used for ion counting. We measure the field enhancement at the tips of carbon nanotubes by field emission of electrons. We demonstrate the operation of the field ionization detector by counting atoms from a thermal beam of a rubidium dispenser source. By measuring the ionization rate of rubidium as a function of the applied detector voltage we identify the field ionization distance, which is below a few tens of nanometers in front of nanotube tips. We deduce from the experimental data that field ionization of rubidium near nanotube tips takes place on a time scale faster than 10{sup -10} s. This property is particularly interesting for the development of fast atom detectors suitable for measuring correlations in ultracold quantum gases. We also describe an application of the detector as partial pressure gauge.
A principle of microplasma generation that utilizes field emission of electrons at the cathode and field ionization producing ions at the anode, both processes relying on nanorods or nanotubes, is explored theoretically. In this plasma generation concept, collisional ionization of atoms and molecules by electron impact would play a negligible role. Analytical estimates as well as plasma kinetic modeling by particle-in-cell method with Monte Carlo collisions in argon confirm that this principle can enable substantial plasma densities at near-collisionless microgaps, while requiring relatively low voltages, less than 100 V. An order of magnitude increase in electron number density can be achieved due to enhancement of field emission at the cathode by positive space charge at high field ionization ion current densities.
Electron transfer in ion microscope field ionization, analyzing band and periodic surface structure effects, ionization probability and collision formalism
Field ionization yield with single graphite whisker lateral surface as ionizer, using helium, ammonia, carbon monoxide and carbon dioxide
A field ionizing element formed of a membrane that houses electrodes therein that are located closer to one another than the mean free path of the gas being ionized. The membrane includes a supporting portion, and a non supporting portion where the ions are formed. The membrane may be used as the front end for a number of different applications including a mass spectrometer, a thruster, an ion mobility element, or an electrochemical device such as a fuel cell.