Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “feeder load disaggregation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A Data-Driven Pivot-Point-Based Time-Series Feeder Load Disaggregation Method

The load profile at a feeder-head is usually known to utility engineers while the nodal load profiles are not. However, the nodal load profiles are increasingly important for conducting time-series analysis in distribution systems. Therefore, in this paper, we present a pivot-point based, two-stage feeder load disaggregation algorithm using smart meter data. The two stages are load profile selection (LPS) and load profile allocation (LPA). In the LPS stage, a random load profile selection process is first executed to meet the load diversity requirement. Then, a few pairs of pivot points are selected as the matching targets. After that, a matching algorithm will run repetitively to select one load profile at a time for matching the reference load profile at the pivot points. In the LPA stage, the LPS selected load profiles are allocated to each load node on the feeder considering distribution transformer loading limits, load composition, and square-footage. The proposed method is validated using actual data collected in a North Carolina service area. Finally, simulation results show that the proposed method can generate a unique load shape for each load node while match the shape of their aggregated profile with the actual feeder head load profile.

42 ENGINEERING↗

Continuation Power Flow Analysis for PV Integration Studies at Distribution Feeders

This paper presents a method for conducting continuation power flow simulation on high-solar penetration distribution feeders. A load disaggregation method is developed to disaggregate the daily feeder load profiles collected in substations down to each load node, where the electricity consumption of residential houses and commercial buildings are modeled using actual data collected from single family houses and commercial buildings. This allows the modeling of power flow and voltage profile along a distribution feeder on a continuing fashion for a 24- hour period at minute-by-minute resolution. By separating the feeder into load zones based on the distance between the load node and the feeder head, we studied the impact of PV penetration on distribution grid operation in different seasons and under different weather conditions for different PV placements.

AC Chronological Power Flow↗

A Two-Step Load Disaggregation Algorithm for Quasi-static Time-series Analysis on Actual Distribution Feeders

This paper focuses on developing a two-step load disaggregation method for conducting quasi-static time-series analysis using actual distribution feeder data. This can help utilities conduct power flow studies using smart meter measurements to assess the impact of high penetration of distributed energy resources. In the first step, load profiles of residential and commercial buildings obtained from smart meter data are used to match the load profile at the feeder head. This step will determine the number of residential and commercial loads on the feeder. The second step is to allocate the selected load profiles to each load node based on its transformer rating. This allows each load node to have its own load profile and the aggregation of those nodal load profiles matches closely to the metered feeder load shape at the substation. This algorithm is validated using smart meter data and the SCADA data of a real feeder. We compared the performance of the proposed method with the traditional load allocation method (i.e. use the feeder load shape for all subsequent load nodes scaling by the transformer capacities) when conducting quasi-static power flow studies. Results show that the proposed algorithm matches the utility data well and the obtained voltage profiles reveal more voltage dynamics than using the conventional load allocation method. (PDF) A Two-Step Load Disaggregation Algorithm for Quasi-static Time-series Analysis on Actual Distribution Feeders.

load disaggregation, load shape, quasi-static, tim↗

Voltage-Load Sensitivity Matrix Based Demand Response for Voltage Control in High Solar Penetration Distribution Feeders

This paper presents a voltage-load sensitivity matrix (VLSM) based voltage control method to deploy demand response resources for controlling voltage in high solar penetration distribution feeders. The IEEE 123-bus system in OpenDSS is used for testing the performance of the preliminary VLSM-based voltage control approach. A load disaggregation process is applied to disaggregate the total load profile at the feeder head to each load nodes along the feeder so that loads are modeled at residential house level. Measured solar generation profiles are used in the simulation to model the impact of solar power on distribution feeder voltage profiles. Different case studies involving various PV penetration levels and installation locations have been performed. Simulation results show that the VLSM algorithm performance meets the voltage control requirements and is an effective voltage control strategy.

distribution system modeling↗

Simulation-Based Analysis of Feeder Operation with Different PV Smart Inverter Functions on an Actual Distribution System: Preprint

High penetration of photovoltaics (PV) in distribution feeders can cause problems, such as overvoltage, reverse power flow, and large net load changes. Traditional voltage regulation devices, such as capacitors and voltage regulators, can solve some of these problems but might have some delays. Today, smart inverters are gradually being used to provide voltage regulation and frequency support in distribution systems. Different smart inverter settings have been recommended in various rules and standards; however, the potential benefits and their impacts on distribution system operation are not well compared and studied. This paper presents a comparison of different smart inverter settings as applied to a distribution system. An actual feeder model from San Diego Gas & Electric Company is used to conduct the simulation. Additionally, a load disaggregation method is proposed to disaggregate the load and PV profile for each load location using advanced metering infrastructure net load measurements. Then, different smart inverter settings are applied to the PV systems in the feeder, and the simulation results are compared. The results show that the implementation of specific functions of smart inverters can reduce voltage exceedances, and the utility can determine the specific inverter setting based on its operational requirements.

distribution system↗

Bayesian Structural Time Series for Behind-the-Meter Photovoltaic Disaggregation: Preprint

Distributed photovoltaic (PV) generation often occurs ``behind the meter": a grid operator can only observe the net load, which is the sum of the gross load and distributed PV generation. This lack of observability poses a challenge to system operation at both bulk level and distribution level. The lack of real-time or near-future disaggregated estimates of gross load and PV generation will lead to over scheduling of energy production and regulation reserves, reliability constraints violations, wear and tear of controller devices, and potentially cascading failures of a system. In this paper we propose the use of a Bayesian Structural Time Series (BSTS) model with local solar irradiance measurements to disaggregate the summed PV generation and gross load signals at a downstream measurement site. BSTSs are a highly expressive model class that blends classic time series models with the powerful Bayesian state space estimation framework. Disaggregation is done probabilistically, which automatically quantifies the uncertainties of the estimated PV generation and gross load consumption. Depending on the data availability in real-time, it can be used to disaggragate PV and gross load at customer site, or can be used at the feeder level. In this paper, we focus on solving the problem at feeder level. We compare the performance of a BSTS model as well as a handful of state-of-the-art methods on a Pecan Street AMI dataset, using the National Solar Radiation Database (NSRDB) to estimate local irradiance.

Bayesian structural time series↗

Feeder Power Disaggregation: A Data-Efficient Matrix Completion Approach

This paper presents a data-driven algorithm for the feeder power disaggregation problem in distribution systems. Leveraging spatio-temporal power patterns in residential homes, residential power is discomposed into three components: sparse-switching loads, periodic loads, and photovoltaic (PV) generation, which are characterized through the design of two sparse matrices and a low-rank matrix. The matrix completion process is data-efficient because of the matrix sparsity and low rankness, along with the use of power system models. The proposed approach is tested using real-world residential data set on a 33-bus distribution system, demonstrating accurate power disaggregation with efficient matrix completion.

distribution system↗

Feeder Power Disaggregation: A Data-Efficient Matrix Completion Approach: Preprint

This paper presents a data-driven algorithm for the feeder power disaggregation problem in distribution systems. Leveraging spatio-temporal power patterns in residential homes, residential power is discomposed into three components: sparse-switching loads, periodic loads, and photovoltaic generation, using two sparse matrices and a rank-one matrix. The matrix completion process is data-efficient because of the matrix sparsity and low rankness, along with the use of power system models. The proposed approach is tested using real-world residential datasets on a 33-bus distribution system, demonstrating accurate power disaggregation with efficient matrix completion.

distribution system↗

Bayesian Structural Time Series for Behind-the-Meter Photovoltaic Disaggregation

Distributed photovoltaic (PV) generation often occurs ``behind the meter": a grid operator can only observe the net load, which is the sum of the gross load and distributed PV generation. This lack of observability poses a challenge to system operation at both bulk level and distribution level. The lack of real-time or near-future disaggregated estimates of gross load and PV generation will lead to over scheduling of energy production and regulation reserves, reliability constraints violations, wear and tear of controller devices, and potentially cascading failures of a system. In this paper we propose the use of a Bayesian Structural Time Series (BSTS) model with local solar irradiance measurements to disaggregate the summed PV generation and gross load signals at a downstream measurement site. BSTSs are a highly expressive model class that blends classic time series models with the powerful Bayesian state space estimation framework. Disaggregation is done probabilistically, which automatically quantifies the uncertainties of the estimated PV generation and gross load consumption. Depending on the data availability in real-time, it can be used to disaggragate PV and gross load at customer site, or can be used at the feeder level. In this paper, we focus on solving the problem at feeder level. We compare the performance of a BSTS model as well as a handful of state-of-the-art methods on a Pecan Street AMI dataset, using the National Solar Radiation Database (NSRDB) to estimate local irradiance.

bayesian structural time series↗

Network-Cognizant Time-Coupled Aggregate Flexibility of Distribution Systems Under Uncertainties

Increasing integration of distributed energy resources (DERs) within distribution feeders provides unprecedented flexibility at the distribution-transmission interconnection. To exploit this flexibility and to use the capacity potential of aggregate DERs, feasible substation power injection trajectories need to be efficiently characterized. This paper provides an ellipsoidal inner approximation of the set of feasible power injection trajectories at the substation such that for any point in the set, there exists a feasible disaggregation strategy of DERs for any load uncertainty realization. The problem is formulated as one of finding the robust maximum volume ellipsoid inside the flexibility region under uncertainty. Though the problem is NP-hard even in the deterministic case, this paper derives novel approximations of the resulting adaptive robust optimization problem based on optimal second-stage policies. The proposed approach yields less conservative flexibility characterization than existing flexibility region approximation formulations. The efficacy of the proposed method is demonstrated on a realistic distribution feeder.

adaptive robust optimization↗

Network-Cognizant Time-Coupled Aggregate Flexibility of Distribution Systems Under Uncertainties

Increasing integration of distributed energy resources (DERs) within distribution feeders provides unprecedented flexibility at the distribution-transmission interconnection. To exploit this flexibility and to use the capacity potential of aggregate DERs, feasible substation power injection trajectories need to be efficiently characterized. This paper provides an ellipsoidal inner approximation of the set of feasible power injection trajectories at the substation such that for any point in the set, there exists a feasible disaggregation strategy of DERs for any load uncertainty realization. The problem is formulated as one of finding the robust maximum volume ellipsoid inside the flexibility region under uncertainty. Though the problem is NP-hard even in the deterministic case, this paper derives novel approximations of the resulting adaptive robust optimization problem based on optimal second-stage policies. The proposed approach yields less conservative flexibility characterization than existing flexibility region approximation formulations. The efficacy of the proposed method is demonstrated on a realistic distribution feeder.

aggregates↗

A Scalable, Distribution Network-Aware, Customer Privacy-Preserving Framework for Operation of Virtual Power Plants

This poster presents a hierarchical control framework for a virtual power plant that leverages behind-the-meter resources for grid services while maintaining customer privacy during setpoint disaggregation. Unlike many existing approaches, the virtual power plant model uses a hierarchical control strategy and an iterative approach to determine the optimal set point dis-aggregation without direct load control while maintaining system-level power flow and voltage constraints. The proposed approach is numerically validated on a synthetic distribution feeder in San Francisco, demonstrating the ability of the framework to provide privacy-preserving virtual power plant services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Combined Transmission and Distribution Test System to Study High Penetration of Distributed Solar Generation

Transmission and distribution (T&D) standard test systems are currently defined separately, and are critical for researchers and engineers to test new solutions. Growing installation of energy resources in distribution and sub-transmission systems is creating higher interactions between T&D systems. This paper proposes a standard test system to study T&D interactions for high penetration of solar photovoltaic (PV) generation. The proposed test system can be used to study and propose solutions to problems such as reverse power flows and voltage control affected by PV variability. The proposed test system combines the transmission IEEE 118 bus system, with the distribution IEEE 123-node feeder. The original test systems are significantly enhanced by adding high penetration of solar PV generation with corresponding full-year minute-resolution chronological data. Conventional generation chronology is achieved by adding dispatch and unit commitment data for AC optimal power flow solutions. And chronological load data is added in both aggregated and disaggregated fashions. Sample applications of the data are provided highlighting voltage control challenges, and the proposed system is made available openly online.

Samaan, Nader A.↗

Variability and Diversity Load Model Tool [SWR-20-03]

The motivation for the development of this tool and the underlying algorithms and methods was to enable the development of high-temporal resolution, realistic time-series data for quasi-static time-series (QSTS) analysis of distribution systems. Often, aggregated load profile data for a distribution circuit is available (e.g. feeder loading data collected via SCADA at the utility substation) and, while this data is typically accurate it masks the considerable variability of the 100’s or 1000’s of individual loads connected on the circuit. This tool was developed to model both the increased variability expected for these individual loads (e.g. the load of a single distribution transformer connected to 8-12 houses) and the expected diversity between loads on the circuit. It is important to note that the difference in variability and diversity, in the context of this tool, is that variability modeling only adds representative variability due to disaggregated load characteristics (e.g. the presence in the load profile of loads turning off and on like an air conditioner/oven) while the average energy profile remains the same as the user supplied power profile. Diversity modeling generates multiple individual load profiles which, in aggregate, sum to the user supplied power profile. Diversity is effectively variability in the energy usage over longer periods of time than seen in the variability model. Put another way, variability modeling supplies the expected variability due to the operation of various end-use loads and diversity modeling supplies the usage differences due to human behavior, schedules, etc. This load modeling tool was developed for use in generating data for distribution systems. Modeling is summarized by two major functions: 1) taking low resolution load profiles and adding intra-seconds variability onto the profiles, and 2) taking a user supplied load profile and distribution factors and adding both diversity and variability to the user supplied profile.

Zhu, Xiangqi↗

Estimating PV power from aggregate power measurements within the distribution grid

The increased integration of photovoltaic (PV) systems in distribution grids reduces visibility and situational awareness for utilities because the PV systems' power production is usually not monitored by them. To address this problem, a method called Contextually Supervised Source Separation (CSSS) has been recently adapted for real-time estimation of aggregate PV active power generation from aggregate net active and reactive power measurements at a point in a radially configured distribution grid (e.g., substation). In its original version, PV disaggregation is formulated as an optimization problem that fits linear regression models for the aggregate PV active power generation and true substation active power load. This paper extends the previous work by adding regularization terms in the objective function to capture additional contextual information such as smoothness, by adding new constraints, by introducing new regressors such as ambient temperature, and by investigating the use of time-varying regressors. Furthermore, we perform extensive parametric analysis to study tuning of the objective function weighting factors in a way that maximizes performance and robustness. The proposed PV disaggregation method can be applied to networks with either a single PV system (e.g., megawatt scale) or many distributed ones (e.g., residential scale) connected downstream of the substation. Simulation studies with real field recorded data show that the enhancements of the proposed method reduce disaggregation error by 58% in winter and 35% in summer compared to previous CSSS-based work. When compared against a commonly used transposition model based approach, the reduction in disaggregation error is more pronounced (78% reduction in winter and 45% in summer). Additional simulations indicate that the proposed algorithm is also applicable for PV systems with time-varying power factors. In conclusion, overall, our results show that—with appropriate modeling and tuning—it is possible to accurately estimate the aggregated PV active power generation of a distribution feeder with minimal or no additional sensor deployment.

14 SOLAR ENERGY↗