Engineering PapersSearch

SEARCH · Engineering Papers

Results for “evolved gas analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Diverse organic molecules on Mars revealed by the first SAM TMAH experiment

The search for organic matter on Mars has rapidly evolved in the past decade with simple aromatic, S-heterocycles, and aliphatic organic molecules detected in Gale crater. We report the in situ detection of >20 organic molecules from clay-bearing sandstones in the ~3.5-billion-year-old Knockfarrill Hill member of Glen Torridon, Gale crater, by the Sample Analysis at Mars instrument suite onboard the Curiosity rover. These molecules were liberated by the onboard tetramethylammonium hydroxide wet chemistry experiment. Diverse thermochemolysis products, including benzothiophene, methyl benzoate, and single and dicyclic aromatic molecules were released and detected by evolved gas analysis and gas chromatography-mass spectrometry. Results indicate the experiment successfully released molecules preserved in ancient macromolecular or free organic matter within Martian bedrock despite ~3.5 billion years of diagenesis and radiation exposure.

Amy J Williams

Analysis of cured carbon-phenolic decomposition products to investigate the thermal decomposition of nozzle materials

The development of a mass spectrometer/thermal analyzer/computer (MS/TA/Computer) system capable of providing simultaneous thermogravimetry (TG), differential thermal analysis (DTA), derivative thermogravimetry (DTG) and evolved gas detection and analysis (EGD and EGA) under both atmospheric and high pressure conditions is described. The combined system was used to study the thermal decomposition of the nozzle material that constitutes the throat of the solid rocket boosters (SRB).

Thompson, James M.

Effectiveness of solid lubricant coatings for friction in hard vacuum (10-9 tor)

A study was made of the efficiency of solid lubricating coatings, based on MoS2 with various binders, during friction and under highvacuum conditions. Mass spectrometry was used for an analysis of the composition of the gas evolved from the coatings in the friction process. It is shown that the vacuum level, loading, and sliding velocity influence coating effectiveness. In the friction process the solid lubricant coatings yield characteristic decay products associated with the chemical nature of the binders. The mechanism of coating breakdown during friction is associated with the binder breakdown mechanism.

Verkin, B. I.

Design of a sample acquistion system for the Mars exobiological penetrator

The Mars Exobiological Penetrator will be imbedded into several locations on the Martian surface. It contains various scientific instruments, such as an Alpha-Particle Instrument (API), Differential Scanning Calorimeter (DSC), Evolved Gas Analyzer (EGA) and accelerometers. A sample is required for analysis in the API and DSC. To avoid impact contaminated material, this sample must be taken from soil greater than 2 cm away from the penetrator shell. This study examines the design of a dedicated sampling system including deployment, suspension, fore/after body coupling, sample gathering and placement. To prevent subsurface material from entering the penetrator sampling compartment during impact, a plug is placed in the exit hole of the wall. A U-lever device is used to hold this plug in the penetrator wall. The U-lever rotates upon initial motion of the core-grinder mechanism (CGM), releasing the plug. Research points to a combination of coring and grinding as a plausible solution to the problem of dry drilling. The CGM, driven by two compressed springs, will be deployed along a tracking system. A slowly varying load i.e., springs, is favored over a fixed displacement motion because of its adaptability to different material hardness. However, to accommodate sampling in a low density soil, two dash pots set a maximum transverse velocity. In addition, minimal power use is achieved by unidirectional motion of the CGM. The sample will be transported to the scientific instruments by means of a sample placement tray that is driven by a compressed spring to avoid unnecessary power usage. This paper also explores possible modifications for size, weight, and time as well as possible future studies.

Thomson, Ron

Mass spectrometric analysis of the volatiles released by heating or crushing rocks

Vacuum extraction with subsequent mass spectrometric analysis of evolved volatiles was selected as the analytical procedure. The high-vacuum gas-handling system was constructed of stainless steel. The system was completely free from mercury, grease, or volatile organic materials. The furnace for heating the samples is discussed together with the high-vacuum crusher, the mass spectrometer, and approaches for water determination. The analytical procedure is considered, giving attention to the extraction of volatiles, adsorption studies, and the analysis of volatiles.

Barker, C.

Investigation of the Ignition and Burning of Materials in Space Cabin Atmospheres. Part 2: Ignition of a Combustible Mixture by a Hot Body with the Effects of Gravity

The ignition of a combustible gas mixture by a hot cylinder under the effect of a gravity field for steady state conditions is examined. For this purpose a horizontal cylinder is considered with gravity as a parameter together with a finite chemical reacting flow generated by free convection with the additional effect of diffusion. Both mass transfer and zero mass transfer cases are considered. By defining an ignition criterion the surface temperature and species are obtained from the analysis as a function of the gravity field. It is supposed that at the point of ignition the heat evolved in the gas is sufficiently high to attain a sustained combustion without any energy from the hot cylinder.

Lew, H. G.

Applications of mass spectrometry techniques to autoclave curing of materials

Mass spectrometer analysis of gases evolved from polymer materials during a cure cycle can provide a wealth of information useful for studying cure properties and procedures. In this paper data is presented for two materials to support the feasibility of using mass spectrometer gas analysis techniques to enhance the knowledge of autoclave curing of composite materials and provide additional information for process control evaluation. It is expected that this technique will also be useful in working out the details involved in determining the proper cure cycle for new or experimental materials.

Smith, A. C.

Onion-shell model of cosmic ray acceleration in supernova remnants

A method is devised to approximate the spatially averaged momentum distribution function for the accelerated particles at the end of the active lifetime of a supernova remnant. The analysis is confined to the test particle approximation and adiabatic losses are oversimplified, but unsteady shock motion, evolving shock strength, and non-uniform gas flow effects on the accelerated particle spectrum are included. Monoenergetic protons are injected at the shock front. It is found that the dominant effect on the resultant accelerated particle spectrum is a changing spectral index with shock strength. High energy particles are produced in early phases, and the resultant distribution function is a slowly varying power law over several orders of magnitude, independent of the specific details of the supernova remnant.

Bogdan, T. J.

Application of ion-induced nucleation mass spectrometry in the analysis of trace gases evolved from a polyimide film during the thermal curing stages

Trace gases evolved from a polyimide film during its thermal curing stages have been studied using ion-induced nucleation mass spectrometry. The technique involved exposing the test gas sample to a low energy beta source and recording the masses of the ion-induced molecular clusters formed in the reaction chamber. On the basis of the experimentally observed molecular cluster spectra, it has been concluded that the dominant trace component had a molecular weight of 87 atomic mass units. This component has been identified as a molecule of dimethylacetamide (DMAC) which had been used as a solvent in the preparation of the test polyimide specimen. This identification has been further confirmed by comparing the spectra of the test gas sample and the DMAC calibration sample obtained with a conventional mass spectrometer. The advantages of the ion-induced nucleation mass spectrometer versus the conventional mass spectrometer are discussed.

Smith, A. C.

Investigation of degradation mechanisms in composite matrices

Degradation mechanisms were investigated for graphite/polysulfone and graphite/epoxy laminates exposed to ultraviolet and high-energy electron radiations in vacuum up to 960 equivalent sun hours and 10 to the ninth power rads respectively. Based on GC and combined GC/MS analysis of volatile by-products evolved during irradiation, several free radical mechanisms of composite degradation were identified. The radiation resistance of different matrices was compared in terms of G values and quantum yields for gas formation. All the composite materials evaluated show high electron radiation stability and relatively low ultraviolet stability as indicated by low G values and high quantum for gas formation. Mechanical property measurements of irradiated samples did not reveal significant changes, with the possible exception of UV exposed polysulfone laminates. Hydrogen and methane were identified as the main by-products of irradiation, along with unexpectedly high levels of CO and CO2.

Giori, C.

On-line mass spectrometric monitoring of the polymerization of a phenolic-resin-based material

Polymerization of phenolic-resin-based materials requires elevated temperatures. The low thermal conductivity of these materials has led to the use of dielectric heating techniques in lieu of standard convection oven heating to obtain a satisfactory cure. The curing rate and therefore the quality of the cured material depends on the heating rate and maximum temperature attained, parameters which are extremely difficult to measure in dielectric heating units. The dielectric curing of these materials was monitored by using a mass spectrometer to measure the partial pressure of phenol in the gas evolved during polymerization. The resulting plots of phenol partial pressure as a function of time have a characteristic shape, and these may be used to indicate the attainment of complete curing. The validity of the mass spectrometric technique was confirmed by chemical analysis of the polymerized samples.

Aikens, D. A.

Narrow ultraviolet emission lines from SN 1987A - Evidence for CNO processing in the progenitor

Results from UV observations of SN 1987A with the IUE satellite are presented, showing that emission lines of He II, C III, N III, N IV, N V, and O III increase in strength with time after May 24, 1987. It is found that increased emission originated in a photoionized low-density circumstellar gas, lost by the progenitor in its red supergiant phase. A nebular analysis reveals a large nitrogen overabundance, indicating that the gas has undergone substantial CNO processing. This suggests that the progenitor of SN 1987A lost much of its hydrogen envelope before the explosion. The findings are consistent with models in which a red supergiant evolves to the blue supergiant stage before exploding.

Fransson, C.

The kinematics and structure of N63A and associated H II regions

Shull (1983) and Shull et al. (1982) discussed very high resolution spectrographic observations of bright knots in the filaments of the Cygnus Loop, IC 443, Puppis A, and Vela X supernova remnants (SNRs). Information on the small-scale thermal, turbulent, and bulk radial motions of the gas in these galactic remnants was obtained on the basis of an analysis of the spectral-line profiles. An analysis by Shull (1983) of N49, located in the Large Magellanic Cloud (LMC) is concerned with the large-scale structural and kinematic properties of N49 as it evolves in a cloudy interstellar medium (ISM). The present investigation represents the companion analysis of N63A, which is also a Type II SNR in the LMC. Echelle spectrograph observations indicate, for the first time, the large-scale kinematic and structural properties of the N63A system. They show clearly that the SNR, like N49, is evolving in a clumpy ISM.

Shull, P., Jr.

Analytical methods for toxic gases from thermal degradation of polymers

Toxic gases evolved from the thermal oxidative degradation of synthetic or natural polymers in small laboratory chambers or in large scale fire tests are measured by several different analytical methods. Gas detector tubes are used for fast on-site detection of suspect toxic gases. The infrared spectroscopic method is an excellent qualitative and quantitative analysis for some toxic gases. Permanent gases such as carbon monoxide, carbon dioxide, methane and ethylene, can be quantitatively determined by gas chromatography. Highly toxic and corrosive gases such as nitrogen oxides, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and sulfur dioxide should be passed into a scrubbing solution for subsequent analysis by either specific ion electrodes or spectrophotometric methods. Low-concentration toxic organic vapors can be concentrated in a cold trap and then analyzed by gas chromatography and mass spectrometry. The limitations of different methods are discussed.

Hsu, M.-T. S.

Ultraviolet spectroscopy of the recurrent nova U Scorpii during outburst

Observations of the recurrent nova U Sco during the 1979 outburst are presented, and the spectral evolution is found to differ from that of other recurrent novas. Spectra are dominated by emission lines, and the strong forbidden-line emission characteristic is conspicuously absent. A method to determine masses of nova shells is outlined, and an analysis of the emission lines shows an enrichment in N relative to C and O, and that the nova ejecta are rich in He relative to H. Optical spectra of U Sco obtained following its return to quiescence show predominantly He II emission lines, which suggests an enrichment of the preoutburst gas in He, and thus the presence of a highly evolved companion.

Williams, R. E.

Techniques for the analysis of gases sequentially released from lunar samples

Description of two methods for the analysis of light gases that are sequentially evolved from 2 to 10 mg of lunar sample. A hydrofluoric acid hydrolysis of lunar material is achieved by repeated exposure of the sample to hydrogen fluoride. In the second technique, gases are evolved from lunar samples by the stepwise heating of these samples to 1400 C. The gases evolved by either hydrolysis or pyrolysis are analyzed in a gas chromatographic system using a helium ionization detector. The sensitivities of this detector for the gases, as analyzed, range from 20 picograms/sec for hydrogen to 0.2 picogram/sec for carbon dioxide.

Desmarais, D. J.

The implications and limitations of the findings of the Viking organic analysis experiment

The gas chromatograph mass spectrometer instrument of the Viking mission has demonstrated the absence of organic compounds in the immediate surface layer of the two landing sites. The demonstration of the successful operation of the instrument (comparison of ground-based test data with those obtained during interplanetary flight and the data from the surface of the planet) and its limitations (e.g., the detection of highly cross-linked polymers or polymeric carbon suboxide) are reviewed. The measurements for bound water are based on indirect data, the detectability of evolved carbon dioxide and ammonia is poor, and oxygen, liberated from the soil samples, can not be detected.

Biemann, K.