Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Magnitude of pseudopotential localization errors in fixed node diffusion quantum Monte Carlo

Growth in computational resources has lead to the application of real space diffusion quantum Monte Carlo to increasingly heavy elements. Although generally assumed to be small, we find that when using standard techniques, the pseudopotential localization error can be large, on the order of an electron volt for an isolated cerium atom. We formally show that the localization error can be reduced to zero with improvements to the Jastrow factor alone, and we define a metric of Jastrow sensitivity that may be useful in the design of pseudopotentials. We employ an extrapolation scheme to extract the bare fixed node energy and estimate the localization error in both the locality approximation and the T-moves schemes for the Ce atom in charge states 3+/4+. The locality approximation exhibits the lowest Jastrow sensitivity and generally smaller localization errors than T-moves although the locality approximation energy approaches the localization free limit from above/below for the 3+/4+ charge state. We find that energy minimized Jastrow factors including three-body electron-electron-ion terms are the most effective at reducing the localization error for both the locality approximation and T-moves for the case of the Ce atom. Less complex or variance minimized Jastrows are generally less effective. Finally, our results suggest that further improvements to Jastrow factors and trial wavefunction forms may be needed to reduce localization errors to chemical accuracy when medium core pseudopotentials are applied to heavy elements such as Ce.

36 MATERIALS SCIENCE↗

Direction-dependent localization errors in SPECT images

Purpose: Single photon emission computed tomography (SPECT) is being investigated for imaging inside radiation therapy treatment rooms to localize biological targets. Here, computer simulations were used to analyze locational and directional dependencies in localization errors and to assess the effects of spatial resolution modeling and observer normalization on localization performance. Methods: SPECT images of the XCAT phantom, containing 12 hot tumors, were reconstructed with detector response function compensation (DRC) and without DRC (nDRC). Numerical observers were forced to select the most suspicious tumor location, using normalized cross correlation (NXC) or un-normalized cross correlation (XC), from 3 cm diameter search volumes that each contained only one tumor. For each tumor site, localization was optimized as a function of the iteration number and postreconstruction smoothing. Localization error, the distance between true and estimated tumor positions, was calculated across the ensembles of 80 images. Direction-dependent localization bias and precision were estimated from the image ensemble. Results: For the six superficial tumors in close proximity to the detector trajectory, mean localization errors were <2 mm and were lowest or comparable using DRC-NXC, though differences from DRC-XC and nDRC-NXC were not statistically significant. DRC-NXC did provide statistically significantly better localization than nDRC-XC for five of these six tumors. At the other six sites where attenuation was more severe and the distance was generally greater between the tumor and detector, DRC typically did not show better localization than nDRC. Observer normalization improved the localization substantially for a tumor near the hotter heart. Localization errors were anisotropic and dependent on tumor location relative to the detector trajectory. Conclusions: This computer-simulation study compared localization performance for normalized and un-normalized numerical observers, which were used to estimate tumor positions in SPECT images, reconstructed with and without DRC. For tumors localized to <2 mm on average, which are good candidates for SPECT-guided radiation therapy, localization performance typically improved by compensating for the detector response function and by using a normalized observer. The observed direction-dependent localization errors have important implications for radiation therapy and are relevant to SPECT imaging in general.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative estimation of localization errors of 3d transition metal pseudopotentials in diffusion Monte Carlo

The necessarily approximate evaluation of non-local pseudopotentials in diffusion Monte Carlo (DMC) introduces localization errors. In this paper, we estimate these errors for two families of non-local pseudopotentials for the first-row transition metal atoms Sc–Zn using an extrapolation scheme and multideterminant wavefunctions. Sensitivities of the error in the DMC energies to the Jastrow factor are used to estimate the quality of two sets of pseudopotentials with respect to locality error reduction. The locality approximation and T-moves scheme are also compared for accuracy of total energies. After estimating the removal of the locality and T-moves errors, we present the range of fixed-node energies between a single determinant description and a full valence multideterminant complete active space expansion. The results for these pseudopotentials agree with previous findings that the locality approximation is less sensitive to changes in the Jastrow than T-moves yielding more accurate total energies, however not necessarily more accurate energy differences. For both the locality approximation and T-moves, we find decreasing Jastrow sensitivity moving left to right across the series Sc–Zn. The recently generated pseudopotentials of Krogel et al. reduce the magnitude of the locality error compared with the pseudopotentials of Burkatzki et al. by an average estimated 40% using the locality approximation. The estimated locality error is equivalent for both sets of pseudopotentials when T-moves is used. Finally, for the Sc–Zn atomic series with these pseudopotentials, and using up to three-body Jastrow factors, our results suggest that the fixed-node error is dominant over the locality error when a single determinant is used.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing quantum memory lifetime with measurement-free local error correction and reinforcement learning

Reliable quantum computation requires systematic identification and correction of errors that occur and accumulate in quantum hardware. To diagnose and correct such errors, standard quantum error-correcting protocols utilize global error information across the system obtained by mid-circuit readout of ancillary qubits. We investigate circuit-level error-correcting protocols that are measurement-free and based on local error information. Such a local error correction (LEC) circuit consists of faulty multi-qubit gates to perform both syndrome extraction and ancilla-controlled error removal. We develop and implement a reinforcement learning framework that takes a fixed set of faulty gates as inputs and outputs an optimized LEC circuit. To evaluate this approach, we quantitatively characterize an extension of logical qubit lifetime by a noisy LEC circuit. For the two-dimensional (2D) classical Ising model and four-dimensional toric code, our optimized LEC circuit performs better at extending a memory lifetime compared with a conventional LEC circuit based on Toom's rule in a subthreshold gate error regime. We further show that such circuits can be used to reduce the rate of mid-circuit readouts to preserve a 2D toric code memory. Lastly, we discuss the application of the LEC protocol on dissipative preparation of quantum states with topological phases.

74 ATOMIC AND MOLECULAR PHYSICS↗

Error Localization Examples: Looking for a Needle in a Haystack

Finite element models (FEM) are routinely developed and used during fabrication of high dollar-value hardware. NASA, as part of the pre-flight certification of launch vehicles, routinely conducts vibration and static tests to calibrate models used for flight-risk assessments. During model calibration, certain areas of the model are modified, using engineering judgment and sensitivity analysis, to match the test results. Unfortunately, tools to identify problem areas in the FEM using test data directly are scarce and infrequently applied. Over the years, error localization algorithms have been proposed with very limited success. Recently, the Analytical Dynamics Model Improvement (ADMI) algorithm, which computes closed-form mass and stiffness corrections to match the test data exactly, have been shown to be an effective Error Localization Algorithm (ELA). The paper discusses three examples where ELA is used with simulated test data to locate problem areas. To gain confidence in the approach, the exact answer is shown along with ELA results. Results show that ELA is able to identify general problem areas consistent with known problem areas. In all examples, the ELA identified area is larger than the exact problem area. Nonetheless, with proper optimization tools, calibration results using the ELA identified areas provide excellent results.

model calibration↗

Error Localization Examples: Looking for a Needle in a Hay-stack

Finite element models (FEM) are routinely developed and used during fabrication of high dollar-value hardware. NASA as part of the pre-flight certification of launch vehicles routinely conducts vibration and static tests to calibrate models used for flight-risk assessments. As part of the calibration process, certain areas in the model are modified, using engineering judgment and sensitivity analysis, to match the test results. Unfortunately, tools to identify problem areas in the FEM using test data directly are scarce. Over the years, Error Localization Algorithms (ELA) have been proposed with very limited success. Recently, the Analytical Dynamics Model Improvement (ADMI) algorithm, which computes closed-form mass and stiffness corrections to match the test data exactly, have been shown to be effective for error localization. The paper will present several FEM example problems where ELA is used with simulated test data to determine FEM problem areas. For each example, the correct answer is shown along with ELA results. It is shown that the ELA process is able to identify general problem areas in the FEM, which are consistent with known model perturbations. However, in most cases the ELA identified area of improvement is larger than the true answer. Nonetheless, with proper optimization tools, calibration results using the ELA identified areas provide excellent results.

error localization↗

Multivariate analysis for the estimation of target localization errors in fiducial marker-based radiotherapy

Purpose: To assess the target localization error (TLE) in terms of the distance between the target and the localization point estimated from the surrogates (|TMD|), the average of respiratory motion for the surrogates and the target (|aRM|), and the number of fiducial markers used for estimating the target (n). Methods: This study enrolled 17 lung cancer patients who subsequently underwent four fractions of real-time tumor tracking irradiation. Four or five fiducial markers were implanted around the lung tumor. The three-dimensional (3D) distance between the tumor and markers was at maximum 58.7 mm. One of the markers was used as the target (P{sub t}), and those markers with a 3D |TMD{sub n}| ≤ 58.7 mm at end-exhalation were then selected. The estimated target position (P{sub e}) was calculated from a localization point consisting of one to three markers except P{sub t}. Respiratory motion for P{sub t} and P{sub e} was defined as the root mean square of each displacement, and |aRM| was calculated from the mean value. TLE was defined as the root mean square of each difference between P{sub t} and P{sub e} during the monitoring of each fraction. These procedures were performed repeatedly using the remaining markers. To provide the best guidance on the answer with n and |TMD|, fiducial markers with a 3D |aRM ≥ 10 mm were selected. Finally, a total of 205, 282, and 76 TLEs that fulfilled the 3D |TMD| and 3D |aRM| criteria were obtained for n = 1, 2, and 3, respectively. Multiple regression analysis (MRA) was used to evaluate TLE as a function of |TMD| and |aRM| in each n. Results: |TMD| for n = 1 was larger than that for n = 3. Moreover, |aRM| was almost constant for all n, indicating a similar scale for the marker’s motion near the lung tumor. MRA showed that |aRM| in the left–right direction was the major cause of TLE; however, the contribution made little difference to the 3D TLE because of the small amount of motion in the left–right direction. The TLE calculated from the MRA ({sup MRA}TLE) increased as |TMD| and |aRM| increased and adversely decreased with each increment of n. The median 3D {sup MRA}TLE was 2.0 mm (range, 0.6–4.3 mm) for n = 1, 1.8 mm (range, 0.4–4.0 mm) for n = 2, and 1.6 mm (range, 0.3–3.7 mm) for n = 3. Although statistical significance between n = 1 and n = 3 was observed in all directions, the absolute average difference and the standard deviation of the {sup MRA}TLE between n = 1 and n = 3 were 0.5 and 0.2 mm, respectively. Conclusions: A large |TMD| and |aRM| increased the differences in TLE between each n; however, the difference in 3D {sup MRA}TLEs was, at most, 0.6 mm. Thus, the authors conclude that it is acceptable to continue fiducial marker-based radiotherapy as long as |TMD| is maintained at ≤58.7 mm for a 3D |aRM| ≥ 10 mm.

60 APPLIED LIFE SCIENCES↗

Contaminant point source localization error estimates as functions of data quantity and model quality

We develop empirically-grounded error envelopes for localization of a point contamination release event in the saturated zone of a previously uncharacterized heterogeneous aquifer into which a number of plume-intercepting wells have been drilled. We assume that flow direction in the aquifer is known exactly and velocity is known to within a factor of two of our best guess from well observations prior to source identification. Other aquifer and source parameters must be estimated by interpretation of well breakthrough data via the advection-dispersion equation. We employ high performance computing to generate numerous random realizations of aquifer parameters and well locations, simulate well breakthrough data, and then employ unsupervised machine optimization techniques to estimate the most likely spatial (or space-time) location of the source. Tabulating the accuracy of these estimates from the multiple realizations, we relate the size of 90% and 95% confidence envelopes to the data quantity (number of wells) and model quality (fidelity of ADE interpretation model to actual concentrations in a heterogeneous aquifer with channelized flow). We find that for purely spatial localization of the contaminant source, increased data quantities can make up for reduced model quality. For space-time localization, we find similar qualitative behavior, but significantly degraded spatial localization reliability and less improvement from extra data collection. Since the space-time source localization problem is much more challenging, we also tried a multiple-initial-guess optimization strategy. Furthermore, this greatly enhanced performance, but gains from additional data collection remained limited.

54 ENVIRONMENTAL SCIENCES↗

Simulation of Local Error Correction of the Surface Shape by a Low-Dimensional Ion Beam

We propose an algorithm for solving the problem of local error correction of the surface shape by a low-dimensional ion beam. The algorithm presumes successive sampling running over protrusions relative to the average height aimed at searching for the optimal etching point satisfying the criterion for the reduction of the sum of derivative moduli on the etching spot. It is shown that the new approach makes it possible to considerably extend the range of spatial frequencies accessible to the action for a given dimension of an ion beam.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Error localization in RHIC by fitting difference orbits

The presence of realistic errors in an accelerator or in the model used to describe the accelerator are such that a measurement of the beam trajectory may deviate from prediction. Comparison of measurements to model can be used to detect such errors. To do so the initial conditions (phase space parameters at any point) must be determined which can be achieved by fitting the difference orbit compared to model prediction using only a few beam position measurements. Using these initial conditions, the fitted orbit can be propagated along the beam line based on the optics model. Measurement and model will agree up to the point of an error. The error source can be better localized by additionally fitting the difference orbit using downstream BPMs and back-propagating the solution. If one dominating error source exist in the machine, the fitted orbit will deviate from the difference orbit at the same point.

43 PARTICLE ACCELERATORS↗

Enhancing detection of topological order by local error correction

The exploration of topologically-ordered states of matter is a long-standing goal at the interface of several subfields of the physical sciences. Such states feature intriguing physical properties such as long-range entanglement, emergent gauge fields and non-local correlations, and can aid in realization of scalable fault-tolerant quantum computation. However, these same features also make creation, detection, and characterization of topologically-ordered states particularly challenging. Motivated by recent experimental demonstrations, we introduce a paradigm for quantifying topological states—locally error-corrected decoration (LED)—by combining methods of error correction with ideas of renormalization-group flow. Our approach allows for efficient and robust identification of topological order, and is applicable in the presence of incoherent noise sources, making it particularly suitable for realistic experiments. We demonstrate the power of LED using numerical simulations of the toric code under a variety of perturbations. We subsequently apply it to an experimental realization, providing new insights into a quantum spin liquid created on a Rydberg-atom simulator. Finally, we extend LED to generic topological phases, including those with non-abelian order.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automated Patient Identification and Localization Error Detection Using 2-Dimensional to 3-Dimensional Registration of Kilovoltage X-Ray Setup Images

Purpose: To determine whether kilovoltage x-ray projection radiation therapy setup images could be used to perform patient identification and detect gross errors in patient setup using a computer algorithm. Methods and Materials: Three patient cohorts treated using a commercially available image guided radiation therapy (IGRT) system that uses 2-dimensional to 3-dimensional (2D-3D) image registration were retrospectively analyzed: a group of 100 cranial radiation therapy patients, a group of 100 prostate cancer patients, and a group of 83 patients treated for spinal lesions. The setup images were acquired using fixed in-room kilovoltage imaging systems. In the prostate and cranial patient groups, localizations using image registration were performed between computed tomography (CT) simulation images from radiation therapy planning and setup x-ray images corresponding both to the same patient and to different patients. For the spinal patients, localizations were performed to the correct vertebral body, and to an adjacent vertebral body, using planning CTs and setup x-ray images from the same patient. An image similarity measure used by the IGRT system image registration algorithm was extracted from the IGRT system log files and evaluated as a discriminant for error detection. Results: A threshold value of the similarity measure could be chosen to separate correct and incorrect patient matches and correct and incorrect vertebral body localizations with excellent accuracy for these patient cohorts. A 10-fold cross-validation using linear discriminant analysis yielded misclassification probabilities of 0.000, 0.0045, and 0.014 for the cranial, prostate, and spinal cases, respectively. Conclusions: An automated measure of the image similarity between x-ray setup images and corresponding planning CT images could be used to perform automated patient identification and detection of localization errors in radiation therapy treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Error Analysis and Comparison of the Swept- and Intersection-Based Remapping Methods

Abstract In this paper, the numerical error of two widely used methods for remapping of discrete quantities from one computational mesh to another is investigated. We compare the intuitive, but resource intensive method utilizing intersections of computational cells with the faster and simpler swept-region-based method. Both algorithms are formally second order accurate, however, they are known to produce slightly different quantity profiles in practical applications. The second-order estimate of the error formula is constructed algebraically for both algorithms so that their local accuracy can be evaluated. This general estimate is then used to assess the dependence of the performance of both methods on parameters such as the second derivatives of the remapped distribution, mesh geometry or mesh movement. Due to the complexity of such analysis, it is performed on a set of simplified elementary mesh patterns such as cell corner expansion, rotation or shear. On selected numerical tests it is demonstrated that the swept-based method can distort a symmetric quantity distribution more substantially than the intersection-based approach when the computational mesh moves in an unsuitable direction.

Klima, Matej↗

An orbit fit program for localizing errors in RHIC

Many errors in an accelerator are evidenced as transverse kicks to the beam which distort the beam trajectory. Therefore, the information of the errors are imprinted in the distorted orbits, which are different from what would be predicted by the optics model. In this note, we introduce an algorithm for fitting the orbit based on an on-line optics model. By comparing the measured and fitted orbits, we first present results validating the algorithm. We then apply the algorithm and localize the location of the elusive source of vertical diurnal variations observed in RHIC. The difference of two trajectories (linear accelerator) or closed orbits (storage ring) should match exactly a betatron oscillation, which is predictable by the optics model, in an ideal machine. However, in the presence of errors, the measured trajectory deviates from prediction since the model is imperfect. Comparison of measurement to model can be used to detect such errors. To do so the initial conditions (phase space parameters at any point) must be determined which can be done by comparing the difference orbit to prediction using only a few beam position monitors (BPMs). The fitted orbit can be propagated along the beam line based on the optics model. Measurement and model will agree up to the point of an error. The error source can be better localized by additionally fitting the difference orbit using downstream BPMs and back-propagating the solution. If one dominating error source exist in the machine, the fitted orbit will deviate from the difference orbit at the same point.

43 PARTICLE ACCELERATORS↗

Tuning the Interpolation Basis in a Multigrid Decomposition for Local Error Control

In the compression of scientific data, error-controlled compressors enable to considerably decrease the size of the dataset while maintaining adequate levels of accuracy. In this paper, we note that multi-level refactoring scheme such as MGARD i) rely on an approximation of the data based on the interpolation of coefficients, ii) estimate the resulting error with global metrics on the dataset. To improve on these two aspects, we propose a method that aims to divide the original dataset into blocks based on their smoothness and refactors each block separately with the most relevant interpolation order. We show the relevance of such a method on tailored datasets and the benefits and challenges when applying it to large scientific data.

Vidal, Nicolas [ORNL]↗