A novel transient infrared imaging method for non-intrusive, low-cost, fast, and accurate air leakage detection in building envelopes

Air leakage through the building envelope in the U.S. accounts for about four quads of energy annually, costing approximately $40 billion per year. However, a high-fidelity and non-intrusive method to detect air leakage has not been demonstrated to date. Here, in this paper, we propose a novel non-intrusive and low-cost method called Transient Infrared (IR) Imaging (TIRI) that can rapidly and accurately identify air leakage locations and relative rates on building envelopes. When the interior and exterior temperatures are different, and a small internal pressure pulse is created by HVAC, the temperature at locations with air leakages will change rapidly, while the areas without a leakage do not change. Based on a heat transfer model, we have derived the temperature change as a function of time after the HVAC is turned on. By tracking the temperature change, which depends on leakage rate and size, we have obtained the air leakage map in the case studies. Using an exterior door as an example, we took transient IR images in different seasons and different times of the day, and successfully obtained the leakage map in all the scenarios. Successfully obtained the air leakage map even when the indoor-outdoor air temperature difference is as small as 2 °C. We have also realized a detection speed of 10s and demonstrated that this method also worked for windows, which have mirror-like IR reflections. Our TIRI method will accelerate the improvement of airtightness in buildings, save building energy, and help reduce greenhouse gas emissions.

42 ENGINEERING↗

What does it take to “see” air leakage through a building envelope?

Unwanted air leakage in buildings can cause health and comfort issues for the building occupants and contribute to rot and mold growth in building materials. Leakage also contributes to unnecessary energy consumption ~4 quads (1172 TWh) per year in the buildings sector in the United States. Finding and repairing leaks through the building envelope can improve the energy efficiency, comfort, air-quality, and moisture durability of the building stock. Typical methods of locating air leakage, such as infrared imaging or smoke tracing, rely on concurrent blower door operation which also measures the total leakage rate of the building. These methods can be disruptive to occupants and can’t measure the contribution of individual leaks to prioritize sealing efforts. ORNL is working on a refraction-based fluid flow imaging technique that can measure the leakage rate of individual leaks from the outside of the building. The working principle of this device is based on the refraction of light caused by the exfiltration because there is a small difference in density between the exfiltration and ambient air. We will discuss the operation of the air leak detector and key variables that affect its performance. We will also present preliminary results showing the visualization capability of this new air leak detector under different conditions. Experiments were completed with different claddings, air temperatures, and lighting conditions.

Boudreaux, Philip↗

Component-Level Analysis of Heating and Cooling Loads in the U.S. Residential Building Stock

The residential building sector accounts for a substantial portion of total energy consumption in the United States and offers a significant opportunity for energy reduction and decarbonization through improvements in energy efficiency. Heating and air conditioning are the primary contributors to residential energy usage and electricity system peak demand. However, due to the diversity of the housing stock and the complexity of factors affecting heating and cooling demand, identifying the relative contributions to heating and cooling loads poses challenges. To address this, we applied the ResStock analysis tool to simulate 550,000 building energy models, providing statistical representation of residential buildings in the contiguous United States. We introduced outputs that quantified the heating and cooling influence of different components of a home, such as air leakage, envelope components (ceilings, walls, windows, foundations), internal heat gains from people, lighting, plug loads, and duct losses and gains. Leveraging the granularity of ResStock, we present a dataset to enable deeper understanding of the contributors to heating and cooling loads as a function of housing characteristics such as location, envelope efficiency, and building type. This work aims to support prioritization of research and development and informed decision-making for residential building decarbonization.

building simulation↗

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of novel techniques for non-invasive air leakage and moisture detection in building envelopes

Unwanted air leakage and moisture in building envelopes can cause high energy consumption, detrimental indoor air quality, poor occupant comfort, and reduction in building material durability. High moisture can cause rot and mold, leading to costly and time-consuming repairs that add to the carbon burden of the building envelope. Novel detection techniques for locating and measuring air leakage flow and areas of high moisture in building envelopes will be presented. The techniques are easy, fast, and non-destructive which can enable quick building envelope assessment, foster retrofits, and lead to energy savings and carbon emission reduction.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)↗

Simulation-Based Analysis of Impacts of Reduced Envelope and Duct Air Leakage on Indoor Air Pollutant Concentrations in Occupied Manufactured Homes

This report presents a simulation-based analysis that estimates the magnitude of indoor air pollutant concentration changes that could result from the proposed energy conservation standards. The analysis was conducted for a 1568 ft 2 , double-wide MH with variations in heating and cooling equipment (either furnace + air conditioner or heat pump) and various types of whole-house mechanical ventilation (continuous exhaust fan or central fan integrated supply), in three locations with varying climate conditions: Chicago IL, Fresno, CA; and Houston TX. The simulations tracked four air pollutants that can reach levels exceeding established safe target levels in homes: acrolein, formaldehyde, fine particulate matter (PM 2.5 ), and nitrogen dioxide (NO 2 ). The simulations considered acrolein and formaldehyde emitted from continuous indoor sources; acrolein, NO 2 and PM 2.5 from cooking; PM 2.5 from dispersed occupant activities; and NO 2 and PM 2.5 from outdoors, using historical data to identify typical levels. The impacts in homes operating or not operating whole-house mechanical ventilation equipment, kitchen and bath exhaust fans, and window opening as ventilation approaches were examined.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lactoferricins impair the cytosolic membrane of Escherichia coli within a few seconds and accumulate inside the cell

We report the real-time response of Escherichia coli to lactoferricin-derived antimicrobial peptides (AMPs) on length scales bridging microscopic cell sizes to nanoscopic lipid packing using millisecond time-resolved synchrotron small-angle X-ray scattering. Coupling a multiscale scattering data analysis to biophysical assays for peptide partitioning revealed that the AMPs rapidly permeabilize the cytosolic membrane within less than 3 s—much faster than previously considered. Final intracellular AMP concentrations of ~80–100 mM suggest an efficient obstruction of physiologically important processes as the primary cause of bacterial killing. On the other hand, damage of the cell envelope and leakage occurred also at sublethal peptide concentrations, thus emerging as a collateral effect of AMP activity that does not kill the bacteria. This implies that the impairment of the membrane barrier is a necessary but not sufficient condition for microbial killing by lactoferricins. The most efficient AMP studied exceeds others in both speed of permeabilizing membranes and lowest intracellular peptide concentration needed to inhibit bacterial growth.

59 BASIC BIOLOGICAL SCIENCES↗

Smartphone application for visualizing building air leakage

Annually, unwanted air leakage through building envelopes accounts for 4 quads of energy consumption in the United States, which translates to about 10% of total building energy consumption. Locating and sealing leakage sites is crucial fordecreasing building energy consumption. Smartphones are ubiquitous and contain sophisticated cameras and highperformance processors that could be employed to visualize air leakage using the background-oriented schlieren imaging technique, making leak detection cheaper and easier. This technique requires a textured and high-contrast background such as a brick or concrete masonry unit wall, a building air leak that has a temperature difference compared with the ambient air, and an imaging system. This work focuses on using smartphones as the imaging system to visualize air leakages. The paper discusses application development and the results of testing to determine leakage visualization performance as a function of leak temperature. The results show that leaks with a temperature difference greater than 16°C compared with the ambient air temperature were visualized using existing smartphones.

Boudreaux, Philip [ORNL] (ORCID:0000000229564665)↗

Application of reference-free natural background–oriented schlieren photography for visualizing leakage sites in building walls

Air leakage in buildings can cause health and comfort concerns for occupants and can contribute to mold growth on building materials, or in extreme conditions, rot of building materials. Unwanted air leakage through the building envelope also contributes to approximately 4 quadrillion Btu (1172 TWh) of energy consumption per year in the building sector in the United States. Locating and sealing leakage sites can improve the energy efficiency, comfort, air quality, and moisture durability of the building stock. Typical methods of finding leakage sites, such as infrared imaging and smoke tracing, rely on concurrent blower door operation, which can also measure the total leakage rate of the building. Smoke tracing can be disruptive to occupants, and infrared imaging and smoke tracing cannot measure the contribution of individual leaks to prioritize sealing efforts. Here, an optical fluid flow imaging technique, reference-free natural background–oriented schlieren imaging, was adapted to visualize air exfiltration. This is the first step in developing a method to noninvasively locate and measure exfiltration or infiltration sites so that sealing efforts can be prioritized. Experimental results of this technique are presented, demonstrating the method's applicability to visualizing exfiltration through three common building claddings in an outdoor environment. Key variables impacting the performance of this technique when applied to building leakage are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Online Calculator to Evaluate the Impact of Airtightness on Residential Building Energy Consumption and Moisture Transfer

Energy consumption in residential buildings is primarily driven by space conditioning applications. Space heating and cooling, on average, consume approximately 50% of the energy in the residential buildings in the U.S. The primary energy use due to infiltration is more than 2.8 Quads, which is 29% of primary energy consumption attributable to fenestration and building envelope components in residential buildings in US in 2010. There are advanced air barrier technologies and construction practices to reduce air leakage in buildings, which are currently available in the market. However, the lack of adequate information on their impact on energy consumption and the durability of buildings has caused the slow adoption of these technologies and methods. In the past, the authors developed an online calculator that estimates the potential energy and cost savings in major U.S., Canadian and Chinese cities from improvement in airtightness in commercial buildings. In 2018–2019, the calculator was expanded to add moisture transfer calculations, given that air leakage through the building envelope can have a significant impact on moisture transfer. The calculator is again being expanded by adding residential and additional commercial building data. In this paper, we present the impact of airtightness in residential buildings on energy consumption and moisture transfer. The study includes the analysis of airtightness in 52 major cities in the U.S. and five cities in Canada on a residential building that includes a crawlspace and has a gas furnace.

Kunwar, Niraj↗

Experimental and data-driven characterization of window-induced air leakage in residential buildings

Windows contributes up to 40% of envelope heat losses and around 9% of total building energy consumption due to air leakage. In the U.S., 48 million homes still use single-pane windows. Although the U.S. has an estimated 1.4 billion windows in its building stock and about 24 million windows are installed annually, only around 29 million individual window replacements (∼2%) occur each year. To address this gap, this study generates empirical evidence by (1) evaluating the contribution of windows to whole-building air leakage in 20 residential buildings using blower door tests before and after window replacement and (2) assessing whether building and window characteristics influence the measured change. Most simulation studies assume that replacing windows not only lowers the U-factor but also reduces air leakage by 10–20%. However, this assumption lacks empirical validation, highlighting the need for experimental analysis of air leakage specifically associated with windows. Using blower door tests in accordance with ASTM E779–19, the results indicated an average reduction in air infiltration of 6.1% within the range of 0.5–19.30% across all buildings and no significant correlations were found between air leakage improvements and any building/window characteristics. This research aims to help homeowners, and energy modelers to provide empirical data on importance of upgrading to more energy-efficient windows, supporting energy-efficient building standards.

Air leakage↗

Pennsylvania and Delaware Energy Code Field Studies (Final Technical Report (FTR)

Led by Northeast Energy Efficiency Partnerships (NEEP) in partnership with Performance Systems Development (PSD), the project aimed to conduct energy code compliance field studies for single-family residential buildings in Pennsylvania and Delaware, as well as multifamily and commercial buildings in Pennsylvania. Using U.S. Department of Energy (DOE) approved methodologies, trained field teams conducted on-site observations and testing to document compliance with key energy efficiency measures, including building envelope insulation, air sealing, duct leakage, windows, and mechanical systems. Data from these studies would then be analyzed to identify construction trends and compliance gaps. The goals included published baseline data for each study, and a training roadmap tailored to each state’s needs. This roadmap would have guided outreach and training for builders, code officials, and other stakeholders on the specific code requirements that offered the greatest opportunity for improvement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Do Flashing and Sealant Materials Need to be Exposed to Extreme Cycling?

In the U.S., over 50% of homes were built before 1980, when minimal building codes existed. The aging of building envelopes can significantly contribute to the air leakage, moisture intrusion, and durability of buildings leading to higher energy demands. Although the durability of building materials and envelope systems has been studied extensively, the durability of specific components like window-wall flashing and sealants remains underexplored. Current standards such as ASTM, NIST, and AAMA primarily focus on durability testing considering the high temperatures only and require sealant testing on anodized aluminum panels, leaving questions about performance in cold or fluctuating temperatures unanswered. Current ASTM and AAMA standards provide guidelines for durability testing but predominantly focus on exposure to higher temperature conditions. It remains unclear how exposure to cold temperatures, or cycles of both hot and cold conditions, affect the durability of these materials. Furthermore, AAMA standards mandate that flashing materials be tested on anodized aluminum panels, which may not reflect real-world applications. Therefore, this initial study aims to explore this concern through testing by constructing two window-wall interface prototypes and applying five different flashing and sealant materials to their joints. These samples were subjected to extreme temperatures, ranging from −34 ℃ (−30 °F) to 50 ℃ (122 °F), over a 28-day period (fourteen cycles of 24 hours), with daily visual inspections to document any signs of deterioration such as wrinkling, distortion, or warping. The study has two main objectives: (1) to determine whether flashing and sealant materials lose their durability and strength when exposed to varying climate conditions, specifically cold climates, and (2) to assess whether the interaction of these materials with different substrates (e.g., lumber, PVC, insulation) affects their durability and strength under varying climate conditions. The findings demonstrate how aging impacts the durability of window-wall systems interfaces, justifying future research that potentially could lead to the development of new testing protocols if significant defects are identified.

Palani, Hevar [ORNL] (ORCID:0000000220211994)↗

Multifamily Air Leakage Evaluation: A Modular Case Study

The purpose of this case study is to compare the air leakage rates of modular and site-built multifamily dwelling units. The methods, materials, and equipment were observed to be very similar in the modular and site-constructed units in this case study. The installation quality of building envelope measures such as insulation and air barrier appeared to be better for modular construction, because they were installed in a controlled, factory setting. Through field observations, we identified cosmetic damage to the envelope of modular units following transport to the building site, but with no resulting significant air leakage pathways. However, we did see air leakage pathways resulting from field modifications to the envelope of modular units to accommodate structural and mechanical connections. We found that the extensive use of through-wall HVAC systems, combined with the transport, placement, and rework of modular units may compromise the high-quality envelope installation and airtightness observed in the factory without careful planning and/or design. Opportunities for improvement identified from the tested modular dwelling units include minimizing and optimally locating penetrations, pre-cutting and detailing penetrations at the factory where possible, properly sealing field modifications, and using split HVAC systems in place of through-wall packaged systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extending the Air and Moisture Leakage Calculator to add Residential Buildings and Additional Commercial Buildings

The DOE Windows and Building Envelope Research and Development Roadmap for Emerging Technologies shows that in 2010, infiltration was responsible for 4 quads of space conditioning primary energy use in the residential and commercial sectors. The relative contribution of air leakage in building heating and cooling load is increasing with improvement in the thermal resistance of building envelopes. Advanced air barrier technologies and construction practices have been developed to reduce air leakage in buildings. However, limited information on the impact of air barrier technologies on energy consumption and the durability of buildings has hindered their adoption. In the past Oak Ridge National Laboratory (ORNL), the National Institute of Standards and Technology (NIST), Air Barrier Association of America (ABBA), and U.S.-China Clean Energy Research Center for Building Energy Efficiency (CERC-BEE) collaborated to develop an online calculator that estimates the potential energy and cost savings in major U.S., Canadian and Chinese cities from improvement in air tightness in commercial buildings. In 2018–2019, the calculator was expanded to add moisture transfer calculations given that air leakage through the building envelope can have a significant impact on moisture transfer and associated impacts. In this study, the calculator is expanded further by adding data for two additional commercial buildings (strip mall and primary school) and a residential building. The team investigated the impact of airtightness on energy consumption and moisture transfer of the added buildings. The study includes the analysis of air tightness in 52 major cities in the U.S. and 5 cities in Canada.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

Aerosol Envelope Sealing of Existing Residences

This report explores the best methods for aerosol envelope sealing of unoccupied, existing residences and documents typical leakage reductions. The project consisted of three distinct efforts: (1) scaled field demonstrations of the sealing process, tracking from setup to sealing and cleanup, (2) laboratory testing of new sealants that dry clear, making them more appropriate for retrofit applications, and (3) BEopt™ (Building Energy Optimization Tool) modeling of the energy implications of the measured reductions in leakage. Overall, aerosol sealing performance in existing homes was effective, with an average leakage reduction of 47% across all 34 sites. Conventional approaches typically only produce leakage reductions of 25%–30%. The aerosol sealing technology could provide a process for existing homes and multifamily units to gain the benefits of a well-sealed home at a reasonable cost with minimal disruption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electric Drive Technologies Consortium (EDTC)/ Cost competitive, high-Performance, highly Reliable (CPR) Power Devices on 4H-SiC (Final Report)

4H-Silicon carbide (4H-SiC) is a wide bandgap semiconductor that offers superior material properties over silicon, including higher critical electric field, thermal conductivity, and electron saturation velocity. These advantages make 4H-SiC highly attractive for high-voltage, high-efficiency power electronics. However, realizing the full potential of SiC requires device technologies that are not only high-performing but also manufacturable and reliable under real-world operating conditions. This report summarizes the outcomes of a five-year R&D effort funded by the U.S. Department of Energy (DOE) under the Electric Drive Technologies Consortium (EDTC), focused on developing cost-competitive, high-performance, and highly reliable (CPR) power devices on 4H-SiC substrates. The program targeted scalable and manufacturable 1.2 kV-class SiC MOSFETs optimized for next-generation electric vehicles, renewable energy systems, and industrial power conversion. The project delivered transformative advancements in SiC power device performance and ruggedness. Particularly, Specific on-resistance (R on,sp ) was reduced by up to 37%, from ~4.0 m$\Omega \cdot$cm 2 in earlier designs to an industry-leading 2.40 m$\Omega \cdot$cm 2 , driven by optimized doping, refined JFET widths, and layout engineering. Breakdown voltages (BV) exceeded 1600 V, marking improvement over legacy baselines, and demonstrating the robustness of newly implemented junction profiles and edge terminations. Short-circuit withstand time (SCWT) saw a remarkable 4$\times$ increase, from ~2 $\mu$s to over 8 $\mu$s, achieved through the successful deployment of deep P-well structures (~1.8–2.0 $\mu$m) via channeling implantation. This innovative process breakthrough enabled precise junction formation without MeV-class implantation tools, reduced leakage under high field stress, and allowed even the shortest-channel devices (down to 0.3 $\mu$m) to achieve both high BV and excellent ruggedness—breaking the traditional trade-off between conduction efficiency and blocking capability. Several novel architectures pushed the performance envelope further. JBSFETs—featuring embedded Schottky portions—eliminated bipolar degradation and drastically reduced third-quadrant leakage, while Ladder MOSFETs introduced a clever orthogonal conduction path that achieved a 15.4% reduction in R on,sp over standard linear designs. Switching performance reached new benchmarks: short-channel devices showed a 31% reduction in total switching energy compared to 0.5 $\mu$m counterparts, while maintaining manageable gate drive requirements. Layout-optimized structures not only improved transconductance but also accelerated switching transitions, pointing to real-world benefits in converter-level efficiency. The devices also passed rigorous reliability validation. Stress-tested across TDDB, HTGB, HTRB, HVP, and burn-in, the devices screened under 30 V/10 hr and 43 V/1 s protocols consistently exhibited tighter lifetime distributions and long-term oxide robustness. These screening techniques proved effective in identifying latent defects and ensuring deployment-grade reliability. Meanwhile, advanced 3D TCAD simulations revealed and resolved electric field hotspots—particularly in HEXFET corners—where fields exceeding 4.8 MV/cm were mitigated through geometry-aware layout corrections. Overall, the results of this project demonstrate a manufacturable and scalable SiC power device platform that addresses key DOE performance targets for efficient, robust, and reliable 1.2kV 4H-SiC Power Devices. The developed technologies represent a meaningful step forward in the commercial readiness of high-voltage SiC solutions and provide a strong foundation for continued advancement in wide bandgap power electronics.

42 ENGINEERING↗