Operationalizing Synchrophasors for Enhanced Grid Reliability and Asset Utilization

The report discusses the development of production-grade synchrophasor software applications. The objective is to improve system reliability and asset utilization for offline as well as real-time considerations, as per the Department of Energy (DOE) guidelines specified by Funding Opportunity Announcement (FOA) DE-FOA-0001492. On the one hand, we have developed grid management applications on how to transform synchrophasor-based monitoring into operator guidance, and commercial grade tools addressing industry needs such as NERC Reliability Standards (MOD 26, MOD 27 and MOD 33). On the other hand, with the wide industrial adoption in mind, the developed applications have been fully discussed with utility partners and installed in the utility partners site including 6 field tests. The Model Validation and Calibration software module has been integrated into GE’s PhasorAnalyticsTM. The first commercial contract has been signed even before the close date of this project. The Angle-based Grid Management (AGM), Fast Voltage Security Assessment (FastVSA), Enhanced Islanding Monitoring(EIM) and Enhanced Disturbance Management (EDM) have been integrated into GE’s Grid Stability Assessment line of applications in e-terra Suite of EMS product.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interconnection of Three Single-Phase Feeders in North America Distribution Systems

This paper proposes a solution for maintaining power balance within all three phases at residential level during islanded mode of operation. Grid abnormalities can lead to isolating the residential microgrid from the main grid, and as a result, distributed generation (DG) units take the full responsibility of supplying local loads. However, in such condition, some phases might face the challenge of meeting local load demand due to the lack of enough power generation, resulting in voltage drop and frequency variation across household loads. In order to resolve this issue, the proposed method in this paper seamlessly interconnects all three single-phase feeders during islanded mode and forms a unified single-phase residential microgrid. Consequently, the load demands in all three phases are met, leading to enhanced voltage and frequency profiles. For this purpose, a seamless transition algorithm is defined which monitors the system condition in real time, and coordinates the operation of all inverter-based DG units in residential microgrid accordingly during transitions. Case study results are provided to verify the validity of proposed method.

Pilehvar, Mohsen S.↗

Mitigating urban heat island and enhancing indoor thermal comfort using terrace garden

The United Nations advocates for sustainable urban planning and design, emphasizing green infrastructure initiatives to mitigate urban heat island effects and enhance the resilience and livability of cities globally. To address urban heat challenges, a study was conducted in Chennai, India, from April to June 2023. The study focused on assessing temperature dynamics on a building's terrace by comparing a well-maintained garden area with an exposed region. Temperature and humidity sensors were deployed in both the garden and exposed areas of the terrace, as well as within rooms beneath it, to monitor hourly temperature fluctuations. The findings indicate a significant reduction in internal room temperatures in areas with rooftop gardens, ranging from 4 to 11 °C, depending on the time of year and sun's position, compared to rooms with fully exposed roof configurations. Additionally, simulation studies were performed to validate these findings, suggesting that optimizing the distribution of soil beds and plant density across the roof could yield an additional temperature reduction of 3–4 °C, resulting in an overall difference of up to 14–15 °C. The study highlights the efficacy of rooftop gardens in providing cooling effects during daylight hours and maintaining temperature parity post-sunset. Through analysis of sensor data, the research elucidates the intricate relationship between green infrastructure and thermal comfort, offering insights for energy-efficient building design and resilient urban planning. The findings underscore the potential of rooftop gardens in fostering a more comfortable, energy-efficient, and sustainable urban living environment.

54 ENVIRONMENTAL SCIENCES↗

Heavy metal imprints in Antarctic snow from research and tourism

Antarctica, long regarded as one of the last pristine environments on Earth, is increasingly affected by human activity. As tourism surges and scientific operations expand, air pollution from local emissions is raising new environmental concerns. Here, in this study, we analyze surface snow samples collected along a ~2,000 km transect, from the South Shetland Islands (62°S) to the Ellsworth Mountains (79°S), to map the geochemical fingerprints of aerosol deposition. We identify distinct spatial patterns shaped by crustal, marine, biogenic, and anthropogenic sources. Notably, we detect heavy metal imprints in the snow chemistry of the northern Antarctic Peninsula, where major research stations are concentrated and marine tourism traffic is most intense. Our findings shed light on the extent of the impacts from energy-intensive local activities in Antarctica, underscoring the need for enhanced environmental monitoring and sustainable management strategies in this fragile region.

Cordero, Raúl R. [Univ. of Groningen, Leeuwarden (↗

Photovoltaic Analysis and Response Support (PARS) Platform for Solar Situational Awareness and Resiliency Services

The project's primary objective is to develop a digital-twin based Photovoltaic (PV) Analysis and Response Support (PARS) platform, which aims to provide real-time situational awareness and optimal response plans. This platform is designed to enhance the performance of hybrid PV systems, making them competitive with or even superior to conventional generation resources. The PARS platform enabled the project team to develop and evaluate an extensive suite of grid support functionalities for the hybrid PV systems to enhance grid performance, across key areas including visibility, dispatchability, security, resilience, and reliability. Given the global push toward achieving 100% clean energy by 2035, there is a significant increase in the integration of inverter-based resources (IBRs) throughout the energy grid. Effectively managing the inherent variability and uncertainty associated with IBRs is crucial for ensuring cost-effectiveness, reliability, and security in both the main grid and islanded microgrids. Constrained to a limited array of IEEE test systems or standard feeder models, traditional IBR modeling struggles to assimilate new field data, accurately reflect system dynamics, and adapt to the evolving energy landscape. In our project, we embraced a Digital Twin (DT) strategy for crafting the PARS platform. A digital twin acts as a precise virtual counterpart of a physical system, built on historical data and continuously honed with real-time insights. This enables the high-fidelity DT to accurately mirror current system operations and forecast future scenarios. Consequently, the PARS platform becomes an ideal environment for testing and refining monitoring, control, power, and energy management algorithms designed to boost hybrid PV system performance. The defining feature of the PARS platform, distinguishing it from other advanced simulation tools, is its exceptional adaptability. This is achieved by employing actual network topologies and utilizing real-time field data for fine-tuning and calibration, ensuring a close emulation of real-world conditions. The project deliverables include: 1) High-fidelity IBR models and tools for real-time parameterization, utilizing real-time field measurements to refine IBR models for enhanced accuracy and performance; 2) Grid-forming and Grid-following capabilities to deliver resilience services, including blackstart, voltage and frequency support, cold-load pick-up, power reserves, and three-phase load balancing across grid-connected and microgrid settings; 3) Machine learning-based forecasting tools and methods for generating synthetic data and topologies, creating diverse and realistic simulation environments for evaluating varied operational scenarios; 4) Advanced microgrid power and energy management algorithms for optimizing the integration and operation of PV, storage, and demand response resources within both feeder and community scales. The power grid data sets are provided by four utility companies in North Carolina and the New York Power Administration. Acting as industry advisors, our industry partners communicated stakeholder needs and regulatory standards to the research teams, aiding technology transfer by incorporating the developed methodologies into their daily operations. This collaboration ensures that the PARS platform, functioning as a power system digital twin, enhances our understanding of IBR dynamic behaviors and enables the development and evaluation of IBR control functions that match or exceed the capabilities of conventional synchronous generators.

14 SOLAR ENERGY↗

Aridity and forest age mediate landscape scale patterns of tropical forest resistance to cyclonic storms

Abstract Cyclonic storms, or hurricanes, are expected to intensify as ocean heat energy rises due to climate change. Ecological theory suggests that tropical forest resistance to hurricanes should increase with forest age and wood density. However, most data on hurricane effects on tropical forests come from a limited number of well‐studied long‐term monitoring sites, restricting our capacity to evaluate the resistance of tropical forests to hurricanes across broad environmental gradients. In this study, we assessed whether forest age and aridity mediate the effects of hurricanes Irma and Maria in Puerto Rico, Vieques and Culebra islands. We leveraged functional trait data for 410 tree species, remotely sensed measurements of canopy height and cover, along with data on forest stand characteristics of 180 of 338 forest monitoring plots, each covering an area of 0.067 ha. The plots represent a broad mean annual precipitation (MAP) gradient from 701 to 4598 mm and a complex mosaic of forest age from 5 to around 85 years since deforestation. Hurricanes resulted in a 25% increase in basal area mortality rates, a 45% decrease in canopy height and a 21% reduction in canopy cover. These effects intensified with forest age, even after considering proximity to the hurricane path. The links between forest age and hurricane disturbances were likely due the prevalence of tall canopies. Tall forest canopies were strongly linked with low community‐weighted wood density (WD). These characteristics were on average more common in moist and wet forests (MAP >1250 mm). Conversely, dry forests were dominated by short species with high wood density (WD > 0.6 g cm −3 ) and did not show significant increases in basal area mortality rates after the hurricanes. Synthesis . Our findings show that selection towards drought‐tolerant traits across aridity gradients, such as short stature and dense wood, enhances resistance to hurricanes. However, forest age modulated responses to hurricanes, with older forests being less resistant across the islands. This evidence highlights the importance of considering the intricate links between ecological succession and plant function when forecasting tropical forests’ responses to increasingly strong hurricanes.

Vargas G., German↗

Application of Atmospheric Gases and Particulate Matter to the Assessment of Urban Heat Island

Background: Urban heat island (UHI), where built areas are warmer compared to non-urban regions, increases human related diseases and mortality. A key challenge in UHI analysis is the designation of sites as urban or suburban/rural; however, the growing complexity of green spaces in urban areas and the predominance of the transportation sector in nonurban areas creates a dilemma for distinct delineation. Objectives: This study aims to utilize the variability of atmospheric components such as particulate matter (PM), inorganic gases, and volatile organic compounds (VOCs) as direct tracers of the degree of urbanization for ground-based measurements to fully comprehend UHI in convoluted regions with indistinct delineation of urban and nonurban environments. Methods: Atmospheric gases and aerosols were used as direct tracers of urbanization for UHI analysis. Inorganic gases and particulate matter were monitored in two sites in a southeastern US city with varying degrees of urbanization. VOCs were analyzed using a proton transfer reaction time-of-flight mass spectrometer. Results: The more-urbanized site exhibited warmer night conditions and elevated total oxidant levels, leading to the formation of nanometer-sized particles. Machine learning analysis revealed similar atmospheric pollutant profiles for both sites, suggesting comparable sources and variability. Biogenic VOCs were enhanced at the less-urbanized site; however, levels of anthropogenic aromatic VOCs were comparable for both sites. A comprehensive mass spectra analysis revealed distinct molecular backbones per site that further affirmed the applicability of VOCs as indicators of urbanization. Conclusion: This study concludes that VOCs provide more direct and accurate information than typical inorganic gases and PM parameters for characterizing the degree of urbanization. Further exploration of VOCs can enhance our understanding of UHI dynamics and its interaction with vegetation in urban green spaces.

Air quality sensor↗

Evaluating the feasibility of using downwind methods to quantify point source oil and gas emissions using continuously monitoring fence-line sensors

The dependable reporting of methane (CH 4 ) emissions from point sources, such as fugitive leaks from oil and gas infrastructure, is important for profit maximization (retaining more hydrocarbons), evaluating climate impacts, assessing CH 4 fees for regulatory programs, and validating CH 4 intensity in differentiated gas programs. Currently, there are disagreements between emissions reported by different quantification techniques for the same sources. It has been suggested that downwind CH 4 quantification methods using CH 4 measurements on the fence line of production facilities could be used to generate emission estimates from oil and gas operations at the site level, but it is currently unclear how accurate the quantified emissions are. To investigate the accuracy of downwind methods, this study uses fence-line simulated data collected during controlled-release experiments as input for a non-standard closed-path eddy covariance (EC), the Gaussian plume inverse model (GPIM), and the backward Lagrangian stochastic (bLs) model in a range of atmospheric conditions. This study's EC attempt was unsuccessful due to data collection and instrumentation issues, resulting in invalid results characterized by underestimated emissions, large negative fluxes, and cospectra/ogives that deviated from their ideal shapes. Consequently, the EC results could not be compared with the GPIM and bLS model. The bLs model demonstrated the highest accuracy for single-release single-point emissions, though it exhibited greater uncertainty than GPIM under multi-release conditions. Across the GPIM and bLs model, the most reliable quantification was achieved with 15 min averaging and a narrow 5° wind sector range. Although EC was limited in this context, future studies should consider employing a standard EC system and further optimizing GPIM and bLs approaches – particularly for complex multi-source scenarios – to enhance quantification accuracy and reduce uncertainty.

03 NATURAL GAS↗

Estimation of intensity, footprint, and capacity of surface urban heat islands using a direction-enhanced adaptive synchronous extraction (DEASE) method

Here, the surface urban heat island (SUHI) effect, assessed through remotely sensed land surface temperature (LST), remains a focal point in urban climate research. Conventional indicators like SUHI intensity (SUHII) and footprint (SUHIF) capture peak values and spatial extent but fail to account for the cumulative thermal load—a critical dimension reflecting the total heat exposure imposed by spatially continuous warming, which directly limits a holistic assessment of ecological and societal impacts of the SUHI effect. Therefore, this study introduces an indicator termed SUHI capacity (SUHIC), designed to quantify the aggregated SUHI effect by integrating the magnitude of the warming signal across all affected areas, thereby enabling a more comprehensive evaluation of urban thermal environments. Furthermore, a direction-enhanced adaptive synchronous extraction (DEASE) method is proposed for the quantification of SUHIC. This method can dynamically identify the optimal background reference area based on the urban-rural LST gradients in various directions within the city, without relying on predefined mathematical models as previously. The results from 102 European cities first confirm that the directional variations in urban-rural LST gradients, and the DEASE method can effectively capture these distinctions for the simultaneous estimation of SUHII, SUHIF, and SUHIC. Secondly, the spatial patterns of absolute SUHIC values show strong associations with those of SUHIF (R2>0.86), while its relative values (normalized by the area of urban) align more closely with SUHII (R2 > 0.64). More importantly, SUHIC can serve as a crucial reference for assessing the urban thermal signal when SUHII and SUHIF diverge. The proposed method and framework contribute to standardizing the quantification of the SUHI effect.

Indicator↗