Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy conversion/systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Analytical Study to Use the Excess Digester Gas of Wastewater Treatment Plants

This study presents an analytical method that can be used to enhance the power production rate and the energy-saving at wastewater treatment plants. The digester used at wastewater treatment plants produces digester gas by anaerobic digestion, with which biofuel production can be achieved. Biofuels can be used to meet some of the energy requirements of the wastewater treatment facility through combined heat and power (CHP) gas engines (cogeneration). Using micro gas turbine (MGT), a CHP technology can be introduced in wastewater treatment plants (WWTPs). The combination of MGTs and absorption chillers is a promising technology as it produces electricity, heating, and cooling simultaneously. The study demonstrated how the waste heat of MGTs could be used to drive absorption chillers. In this analytical study, a detailed technical and economic analysis is provided on the trigeneration system, i.e., the integration of MGTs and absorption chillers driven by waste digester gas of the wastewater treatment plants. It can meet the heating and cooling demands of the plants, which promote the reduction of utility costs. The technology presented is also useful for other thermal energy users.

09 BIOMASS FUELS↗

Performance of an Isobaric Hybrid Compressed Air Energy Storage System at Minimum Entropy Generation

Efficient, large-scale, and cost-effective energy storage systems provide a means of managing the inherent intermittency of renewable energy sources and drastically increasing their utilization. Compressed air energy storage (CAES) and its derivative architectures have received much attention as a viable solution; however, optimization objectives for these systems have not been thoroughly investigated in the literature. In this work, a hybrid thermal and compressed air energy storage (HT-CAES) system is investigated that mitigates the shortcomings of the otherwise attractive conventional CAES systems and its derivatives—shortcomings such as strict geological locations, low energy densities, and the production of greenhouse gas emissions. The HT-CAES system allows a portion of the available energy to operate a compressor and the remainder to be converted and stored in the form of heat through joule/resistive heating in a high-temperature, sensible, thermal energy storage medium. Internally reversible and irreversible HT-CAES system assumptions were investigated, in addition to regenerative and non-regenerative design configurations. Several system optimization criteria were examined—including maximum energy efficiency, maximum exergy efficiency, maximum work output, and minimum entropy generation—with a focus on whether the latter may lead to conclusive design guidelines in a real system. It is shown that an HT-CAES system designed based on a minimum entropy generation objective may operate at a lower energy and exergy efficiency as well as lower output power than otherwise achievable. Furthermore, optimization objective equivalence is shown to be limited to certain design conditions.

25 ENERGY STORAGE↗

Process Failure Detection via Recurrence Quantification Analysis in a Slot-Rectangular Spouted Bed

A study was conducted to explore the applicability of recurrence and recurrence quantification analysis (RQA) to the detection of process failures in spouted bed reactor systems. Here, three different potential failure modes were examined in a transparent, cold flow slot-rectangular spouted bed. These being, a simulated air leak from a side wall of the reactor, a simulated gas leak from the top wall of the reactor, and simulated agglomeration of solids via introduction of larger “klinker” particles. Bed pressure drop time history data were collected and analyzed via generation of recurrence plots (RPs) and RQA parameters. In general, the simulated agglomeration case was quite easily detected via ever RQA Parameter examined, whereas the simulated air leaks were detected by only a single RQA parameter.

30 DIRECT ENERGY CONVERSION↗

Measurement of Convective Heat Transfer Coefficients With Supercritical CO 2 Using the Wilson-Plot Technique

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO 2 flowing in a smooth tube and compares the results with published correlations for validation. The paper also describes the Heat Exchange and Experimental Testing (HEET) rig recently designed and built at the U.S. Department of Energy’s (DoE’s) National Energy Technology Laboratory (NETL) in Morgantown, WV. Here, the Wilson-plot technique used for measuring the heat transfer coefficients is described along with the data reduction process. The Wilson-plot technique was chosen as the basis for the design of NETL’s HEET rig. Advantages of the Wilson-plot technique include the (1) ability to measure high convective heat transfer coefficients accurately, (2) ability to measure average heat transfer coefficient for complicated heat exchange geometries like those produced using additive manufacturing, (3) ability to measure heat transfer coefficients on both sides of a heat exchanger independently, and (4) simplicity of experimental setup. Capabilities of the HEET rig include pressure to 24 MPa (3500 psig), temperature to 538 °C (1000 °F), mass flow rate to 1.5 kg/s (3 lb/s), and Re to 500,000. The rig is designed to operate with pure CO 2 or a mixture of CO 2 and up to 10% N2 by volume to study the impact of gas mixtures typical of direct-fired sCO 2 power cycles on the convective heat transfer and pressure drop. Preliminary tests in the HEET rig were performed with smooth stainless-steel tube and pure CO 2 , and the results were compared with published correlations for Nusselt number (Nu) and friction factor. Over a Reynolds number (Re) range from 58,000 to 228,000, measured Nu was compared to predictions using the Dittus and Boelter equation (Kreith and Bohn, 1993, “Principles of Heat Transfer, West Publishing Company”) within 5% and measured friction factors were compared to predictions using the McAdams correlation (“McAdams, 1954, “Heat Transmission,” 3rd ed., McGraw Hill, New York)” for smooth tube to be within 5%.

42 ENGINEERING↗

Study of Energy Saving Analysis for Different Industries

This study analyzes the energy consumption and saving performance in the industries in the U.S.A. All energy assessments implemented were for facilities whose annual energy consumptions were less than 9,000,000 kWh (small- and medium-sized industries) that belong to the manufacturing industries with Standard Industrial Classification (SIC) codes ranging from 2000 to 3999 in addition to SIC codes starting with 49. In this study, assessments are classified based on the SIC codes with recommendations analysis for each classification to get a better idea of what recommendations were suggested in each major industrial sector, knowing that 68 assessments were made, and their SIC ranged from 14 to 49. In addition, this study could be considered as a guide for energy engineers and other personnel involved in the energy assessment process. The information investigated can give a better prediction for composing better energy-demanding industries and minimizing energy consumption. More than 61 energy assessments were conducted for manufacturing facilities and analyzing the data gathered and processed. Through the research, the Fabricated Metal industry achieved the highest average kWh savings and cost savings within the industries studied in this study. According to the average gigajoule (GJ) savings, the fabricated metal industry ranked second within the studied industries. Conversely, Food and Kindred Products achieved the highest GJ energy savings within the studied industries. Overall, lighting, motors, compressors, and heating, ventilation, and air conditioning (HVAC) were the most contributing industries in a total of 547 recommendations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Revisiting Theoretical Limits for One Degree-of-Freedom Wave Energy Converters

This work revisits the theoretical limits of one degree-of-freedom wave energy converters (WECs). This work considers the floating sphere used in the OES Task 10 WEC modeling and verification effort for analysis. Analytical equations are derived to determine bounds on displacement amplitude, time-averaged power (TAP), and power-take-off (PTO) force. A unique result found shows that the TAP absorbed by a WEC can be defined solely by the inertial properties and radiation hydrodynamic coefficients. In addition, a unique expression for the PTO force was derived that provides lower and upper bounds when resistive control is used to maximize power generation. For complex conjugate control, this same expression only provides a lower bound, as there is theoretically no upper bound. These bounds assist in comparing the performance of the floating sphere if it were to extract energy using surge or heave motion. The analysis shows because of differences in hydrodynamic coefficients for each oscillating mode, there are different frequency ranges that provide better power capture efficiency. The influence of a motion constraint on TAP while utilizing a nonideal power take-off is examined and found to reduce the losses associated with bidirectional energy flow. The expression to calculate TAP with a nonideal PTO is modified by the electrical conversion efficiency and the ratio of the PTO spring and damping coefficients. Furthermore, the PTO spring and damping coefficients were separated in the expression, allowing for limits to be set on the PTO coefficients to ensure net power generation.

16 TIDAL AND WAVE POWER↗

Isothermal Versus Sensible Cold Storage: A Model-Based Performance Comparison for Pumped Thermal Electricity Storage

Pumped-thermal energy storage (PTES) systems consume and produce electrical energy using thermal storage media as an intermediate stage. PTES lends itself to long-duration energy storage to facilitate high penetration of intermittent electricity generation. This study presents a model-based comparison of two thermal storage types within a PTES system: a conventional, single-phase, stratified water-glycol sensible storage system (SGS), and an ideal isothermal, two-phase heat exchanger that freezes a water reservoir (isothermal heat exchanger (IHEX)). The SGS thermal storage capacity is based on the liquid’s sensible heat change with temperature, whereas the capacity of the IHEX is based on the latent heat of isothermally freezing and melting water. The idealized IHEX modeled here undergoes steady-state melting and freezing (in contrast to transient rates, as observed with ice-on-coil storage). A computational model of a complete PTES system is presented and used to evaluate the PTES system-level performance with each type of cold storage. Compared to SGS-based PTES, under nominal operating conditions, the IHEX-based PTES increased electrical round-trip efficiency from 61% to 82% and increased energy density from 1.13 to 8.09 kWh/m 3 In conclusion, the performance of the PTES configured with IHEX storage was also analyzed under varying operating parameters.

25 ENERGY STORAGE↗

Performance of Hybrid Renewable Energy Power System for a Residential Building

Using fossil fuels as the primary way to generate electricity causes a significant effect on the environment. In 2019, more than 64% of the electricity in the United States of America was generated using fossil-fuel resources, while renewable energy (RE) resources contributed to only 17% of the U.S. electricity generation for the same year. Additionally, due to the complex terrain distribution of many states in the U.S., a massive opportunity of utilizing RE resources in rural and remote areas can reduce the cost of electrical grid installation for such areas. In this study, a typical residential building with an average energy utilization of 30.25 kWh/day with a demand peak of 5.34 kW was considered a case study in each state to optimize a hybrid RE system and find the best alternative electrical grid system. This study presents the best configuration between solar and wind energy with different types of energy storage. It was discovered the photovoltaic (PV) solar panels—diesel generators with battery best services in all states. The daily radiation and diesel prices substantially affect the levelized cost of energy (COE) values in each state.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Physics-Informed Deep Learning-Based Proof-of-Concept Study of a Novel Elastohydrodynamic Seal for Supercritical CO 2 Turbomachinery

Supercritical carbon dioxide (sCO 2 ) power cycles show promising potential of higher plant efficiencies and power densities for a wide range of power generation applications such as fossil fuel power plants, nuclear power production, solar power, and geothermal power generation. sCO 2 leakage through the turbomachinery has been one of the main concerns in such applications. To offer a potential solution, we propose an elastohydrodynamic (EHD) seal that can work at elevated pressures and temperatures with low leakage and minimal wear. The EHD seal has a very simple, sleeve-like structure, wrapping on the rotor with minimal initial clearance at micron levels. Here, in this work, a proof-of-concept study for the proposed EHD seal was presented by using the simplified Reynolds equation and Lame’s formula for the fluid flow in the clearance and for seal deformation, respectively. The set of nonlinear equations was solved by using both the conventional Prediction–Correction (PC) method and modern Physics-Informed Neural Network (PINN). It was shown that the physics-informed deep learning method provided good computational efficiency in resolving the steep pressure gradient in the clearance with good accuracy. The results showed that the leakage rates increased quadratically with working pressures and reached a steady-state at high-pressure values of 15~20 MPa, where Q = 300 g/s at 20 MPa for an initial seal clearance of 255 μm. This indicates that the EHD seal could be tailored to become a potential solution to minimize the sCO 2 discharge in power plants.

30 DIRECT ENERGY CONVERSION↗

Near-Critical CO 2 -Assisted Liquefaction-Extraction of Biomass and Wastes to Fuels and Value-Added Products

With the growing need for sustainable carbon-neutral liquid fuels, low-grade feedstocks, such as lignocellulosic biomass, and municipal solid wastes offer sufficient potential via thermochemical conversion. But the existing thermochemical means are limited in feed flexibility and scalability and require significant processing (energy and costs) of the intermediates. Bio-oil/biocrude intermediate from fast pyrolysis and hydrothermal techniques is impeded by issues of stability and oxygen content, along with hydrotreating viability. To address these issues, we investigated a novel pathway of near-critical CO 2 -assisted integrated liquefaction-extraction (NILE) technology in conceptual aspects for conversion of various biomass and municipal solid wastes into high-quality biocrude with high compatibility for co-hydrotreating with traditional fossil crude for liquid fuel needs in power and transportation sectors. Using supercritical CO 2 for dewatering wet feedstocks, for liquefaction, and extraction for lighter biocrude has produced biocrude with lower oxygen content by 50%, lowered metal content by 90%, stable viscosity, low acidity, and good aging stability compared to that produced from hydrothermal liquefaction along with higher hydrotreating and co-hydrotreating compatibility. Hydrotreating of the biocrude extract from supercritical CO 2 extraction also was feasible with no detected coke deposition, an oxygen content of 1%, and catalyst deactivation. Here, the validation and capabilities of the NILE concept urge for its further development to obtain sustainable liquid fuels with lower greenhouse gas emissions and costs.

09 BIOMASS FUELS↗

Film Cooling Performance Prediction for Air and Supercritical CO 2

The current study explores the possibility of cooling the vanes and blades of a direct-fired sCO 2 turbine using film cooling. The operating conditions of a direct-fired sCO 2 cycle and thermophysical properties of the fluid at those conditions can alter the flow field characteristics of the coolant jet and its mixing with the mainstream. Very little information is present in the literature regarding the performance of film cooling geometries employing supercritical CO 2 . The objective of this study is to estimate the resulting film cooling effectiveness while also capturing the effects of the crossflow-to-mainstream velocity ratio on the coolant jet. Herein, a computational fluid dynamic model is used to study the coolant jet exiting a cylindrical hole located on a flat plate, with the coolant fed by an internal channel. Steady-state Reynolds-averaged Navier–Stokes equations were solved along with the (shear-stress transport) SST k–ω model to provide the turbulence closure. The operating conditions for the direct-fired sCO 2 turbine are obtained using an in-house Cooled Turbine Model. Numerical predictions revealed that the crossflow effects and jet lift-off were more pronounced in the case of sCO 2 when compared to air. Spatial distribution of flow field and cooling effectiveness are presented at different operating conditions.

30 DIRECT ENERGY CONVERSION↗

Design of a 1 MWth Supercritical Carbon Dioxide Primary Heat Exchanger Test System

A new generation of Concentrating Solar Power (CSP) technologies is under development to provide dispatchable renewable power generation and reduce the levelized cost of electricity (LCOE) to 6 cents/kWh by leveraging heat transfer fluids (HTF) capable of operation at higher temperatures and coupling with higher efficiency power conversion cycles. The U.S. Department of Energy (DOE) has funded three pathways for Generation 3 CSP (Gen3CSP) technology development to leverage solid, liquid, and gaseous HTFs to transfer heat to a supercritical carbon dioxide (sCO 2 ) Brayton cycle. Here we present the design and off-design capabilities of a 1 MWth sCO 2 test system that can provide sCO 2 coolant to the primary heat exchangers (PHX) coupling the high-temperature HTFs to the sCO 2 working fluid of the power cycle. This system will demonstrate design, performance, lifetime, and operability at a scale relevant to commercial CSP. A dense-phase high pressure canned motor pump is used to supply up to 5.3 kg/s of sCO 2 flow to the primary heat exchanger at pressures up to 250 bar and temperatures up to 715 °C with ambient air as the ultimate heat sink. Key component requirements for this system are presented in this paper.

14 SOLAR ENERGY↗

Power Take-Off Design Study for a Small-Scale Oscillating Surge Wave Energy Converter for Powering the Blue Economy Applications

The power take-off (PTO) is an integral part of wave energy conversion, and the design process is nontrivial. Better PTOs, and better processes for selecting and designing PTO architectures for various applications, would benefit devices that assist in powering the blue economy by decreasing time and money spent on PTO design and increasing the overall energy capture performance of these devices. This paper chronicles the selection process of a PTO for a small-scale surge-type wave energy converter (WEC) for the purpose of informing future PTO selection processes. Three PTO architectures are evaluated in WEC-Sim: a hydraulic check valve PTO, a hydraulic active valving PTO, and a directly electrified PTO. Simple models of each PTO are constructed. Because a model for the small-scale device was initially unavailable, the PTOs are simulated on a large-scale device. The results are scaled down using Froude scaling and compared to results from directly simulating a small-scale model. Strong assumptions are made because this work is early in the design stages, and a coarse look at PTO options was desired. Specifically, the effectiveness of controls is investigated, along with the efficiency of energy conversion. However, energy capture is only part of the consideration; there are also logistic concerns to be considered when selecting a PTO. For example, components for large-scale WECs are so large and expensive that it may make sense to custom-build PTO components, but small-scale WECs would benefit from off-the-shelf availability because the cost of customization would be a significant portion of the total capital cost of deployment at a small scale. Submersible, off-the-shelf components are much easier to source for hydraulic PTOs. Because of highly effective controls, efficient energy conversion, and availability of marine-grade components, an active valving hydraulic PTO is selected for this small-scale surge-type WEC.

energy conversion/systems↗

Power Take-Off Design Study for a Small-Scale Oscillating Surge Wave Energy Converter for Powering the Blue Economy Applications: Preprint

The power take-off (PTO) is an integral part of wave energy conversion, and the design process is nontrivial. Better PTOs, and better processes for selecting and designing PTO architectures for various applications, would benefit devices that assist in powering the blue economy by decreasing time and money spent on PTO design and increasing the overall energy capture performance of these devices. This paper chronicles the selection process of a PTO for a small-scale surge-type wave energy converter (WEC) for the purpose of informing future PTO selection processes. Three PTO architectures are evaluated in WEC-Sim: a hydraulic check valve PTO, a hydraulic active valving PTO, and a directly electrified PTO. Simple models of each PTO are constructed. Because a model for the small-scale device was initially unavailable, the PTOs are simulated on a large-scale device. The results are scaled down using Froude scaling and compared to results from directly simulating a small-scale model. Strong assumptions are made because this work is early in the design stages, and a coarse look at PTO options was desired. Specifically, the effectiveness of controls is investigated, along with the efficiency of energy conversion. However, energy capture is only part of the consideration; there are also logistic concerns to be considered when selecting a PTO. For example, components for large-scale WECs are so large and expensive that it may make sense to custom-build PTO components, but small- scale WECs would benefit from off-the-shelf availability because the cost of customization would be a significant portion of the total capital cost of deployment at a small scale. Submersible, off-the-shelf components are much easier to source for hydraulic PTOs. Because of highly effective controls, efficient energy conversion, and availability of marine-grade components, an active valving hydraulic PTO is selected for this small-scale surge-type WEC.

electric PTO↗

Using Machine Learning Tools to Predict Compressor Stall

Clean energy has become an increasingly important consideration in today’s power systems. As the push for clean energy continues, many coal-fired power plants are being decommissioned in favor of renewable power sources such as wind and solar. However, the intermittent nature of renewables means that dynamic load following traditional power systems is crucial to grid stability. With high flexibility and fast response at a wide range of operating conditions, gas turbine systems are poised to become the main load following component in the power grid. Yet, rapid changes in load can lead to fluid flow instabilities in gas turbine power systems. These instabilities often lead to compressor surge and stall, which are some of the most critical problems facing the safe and efficient operation of compressors in turbomachinery today. Although the topic of compressor surge and stall has been extensively researched, no methods for early prediction have been proven effective. This study explores the utilization of machine learning tools to predict compressor stall. The long short-term memory (LSTM) model, a form of recurrent neural network (RNN), was trained using real compressor stall datasets from a 100 kW recuperated gas turbine power system designed for hybrid configuration. Two variations of the LSTM model, classification and regression, were tested to determine optimal performance. The regression scheme was determined to be the most accurate approach, and a tool for predicting compressor stall was developed using this configuration. Overall, results show that the tool is capable of predicting stalls 5–20 ms before they occur. With a high-speed controller capable of 5 ms time-steps, mitigating action could be taken to prevent compressor stall before it occurs.

42 ENGINEERING↗

Leveraging National Laboratory Assets to Address Stability Challenges due to Declining Grid Inertia Using Geographically Distributed Electrical–Thermal Co-Emulation

Due to increased penetration of low-inertia resources into the electric grid, challenges are increasing for maintaining wide-area system stability. Grid stability assessment requires a faithful representation of the multiple-physics interaction at the system level, and timescales of interaction varying in orders of magnitude, from microseconds to seconds to several minutes. Along with the simulation-based techniques, hardware-in-the-loop (HIL), controller HIL, and power HIL techniques have been developed to better understand the emergent behavior of the system with emerging technologies. US National Laboratories have played a vital role in research and development to understand the behavior of individual technologies and devices integrated to the electric grid. Each national laboratory forwards a technological and strategic initiative tied core and enabling capabilities. Due to strategic, efficiency, and economic reasons, not all the labs have assets to conduct research on all technologies concomitantly, so it becomes crucial to integrate the labs across geographies to understand the interplay of different technologies together at the system level. This approach avoids duplication of the assets at different lab facilities and helps understand the integrated system behavior of various technologies representative of actual grid conditions by connecting multiple national labs. This article talks about techniques of connecting three national laboratories to enable co-emulation of electrical–mechanical–thermal characteristics of devices and systems. Such an approach can be used to understand the dynamic and transient interaction of multi-physics in a system level, at-scale emulation using real-time simulation tools and techniques.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fuel Stratification Influence on NO x Emission in a Premixed Axial Reacting Jet-in-Crossflow at High Pressure

Three reacting jet-in-crossflow (JiC) methane/air flames were numerically investigated in a lean axially staged combustor at a pressure of five atmospheres. A detailed chemistry Star-CCM+ computational fluid dynamics (CFD) model was used with 53 species considered and the result of turbulence-governed finite-rate modeling was validated with in-house experimental data. An optically accessible test section features three side windows, allowing local flow and flame analysis with particle image velocimetry (PIV) and CH* chemiluminescence as well as pressure, temperature, and species exit measurements. The research objective was to predict and verify NO x formation of the premixed 12.7 mm axial jet. Three headend temperature levels were investigated along with three premixed jets at lean (φ Jet = 0.75), near-stoichiometric (φ Jet = 1.07), and rich (φ Jet = 1.78) axial fuel line equivalence ratio. Based on the matching exit emission concentration, global emission benefits were investigated by adjustment of the fuel stratification. The perfectly premixed methane/air flames of this study were shown to ignite at the lee-side of the jet. For the elevated headend temperature level T = 1800 K, the flame extended beyond the windward jet trajectory and caused high axial NO production. For industry application, a firing temperature of 1920 K was achieved with a NO x optimized fuel split of 25%, combining a lean headend (φ Headend = 0.61) with a rich (φ Jet = 1.78) jet equivalence ratio. As a result, this operating point allowed minimization of the combustor residence time at temperatures above 1700 K as well as combustion in a compact flame at the jet lee-side along the counter rotating vortex pair.

03 NATURAL GAS↗

Experimental Investigation of Gaseous Mixtures of Ethane, Methane, and Carbon Dioxide as an Alternative to Conventional Fuel in Spark Ignition Engines

This study investigates the viability and performance of certain synthetic fuels in spark ignition internal combustion engine based stationary power generation wherein the fuel comprises a mixture of methane and ethane in high dilutions of carbon dioxide (CO 2 ). The fuel of concern is a byproduct of a novel method for producing ethylene from ethane. The byproduct gas mixture has a concentration of approximately 41% CO 2 , 40% ethane, and 5% methane by weight along with other minor compounds. Varying mixtures of ethane and methane combined with between 42% and 46% by weight CO 2 were used to evaluate the viability and efficiency of this fuel to operate in existing internal combustion engines as a means of reducing emissions and increasing industrial process efficiency. A 13 hp gasoline generator was repurposed as a test stand by incorporating a modified fuel induction system and instrumentation for data collection. A gas metering and mixing system was installed to precisely control the mass flow of gases induced into the engine. Various instrumentations were installed to monitor in-cylinder pressure, temperature at various locations, emissions, and fuel and airflow rates. Varying fuel mixtures and loads were tested and compared to gasoline. It was found that under a high load, the mixed gas was able to generate comparable thermal efficiency and power to gasoline. But under no load or a part load condition the indicated thermal efficiency was found to be about 21% lower than that of gasoline. Further, the mixed gas also resulted in up to 50% reduction in CO and NOx emissions when compared to gasoline.

42 ENGINEERING↗