Results for “energy analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Asymptotic modal analysis and statistical energy analysis

Statistical Energy Analysis (SEA) is defined by considering the asymptotic limit of Classical Modal Analysis, an approach called Asymptotic Modal Analysis (AMA). The general approach is described for both structural and acoustical systems. The theoretical foundation is presented for structural systems, and experimental verification is presented for a structural plate responding to a random force. Work accomplished subsequent to the grant initiation focusses on the acoustic response of an interior cavity (i.e., an aircraft or spacecraft fuselage) with a portion of the wall vibrating in a large number of structural modes. First results were presented at the ASME Winter Annual Meeting in December, 1987, and accepted for publication in the Journal of Vibration, Acoustics, Stress and Reliability in Design. It is shown that asymptotically as the number of acoustic modes excited becomes large, the pressure level in the cavity becomes uniform except at the cavity boundaries. However, the mean square pressure at the cavity corner, edge and wall is, respectively, 8, 4, and 2 times the value in the cavity interior. Also it is shown that when the portion of the wall which is vibrating is near a cavity corner or edge, the response is significantly higher.

Dowell, Earl H.

Asymptotic modal analysis and statistical energy analysis

Asymptotic Modal Analysis (AMA) is a method which is used to model linear dynamical systems with many participating modes. The AMA method was originally developed to show the relationship between statistical energy analysis (SEA) and classical modal analysis (CMA). In the limit of a large number of modes of a vibrating system, the classical modal analysis result can be shown to be equivalent to the statistical energy analysis result. As the CMA result evolves into the SEA result, a number of systematic assumptions are made. Most of these assumptions are based upon the supposition that the number of modes approaches infinity. It is for this reason that the term 'asymptotic' is used. AMA is the asymptotic result of taking the limit of CMA as the number of modes approaches infinity. AMA refers to any of the intermediate results between CMA and SEA, as well as the SEA result which is derived from CMA. The main advantage of the AMA method is that individual modal characteristics are not required in the model or computations. By contrast, CMA requires that each modal parameter be evaluated at each frequency. In the latter, contributions from each mode are computed and the final answer is obtained by summing over all the modes in the particular band of interest. AMA evaluates modal parameters only at their center frequency and does not sum the individual contributions from each mode in order to obtain a final result. The method is similar to SEA in this respect. However, SEA is only capable of obtaining spatial averages or means, as it is a statistical method. Since AMA is systematically derived from CMA, it can obtain local spatial information as well.

Dowell, Earl H.

Asymptotic modal analysis and statistical energy analysis

The sound field of a structural-acoustic enclosure was subject to experimental analysis and theoretical description in order to develop an efficient and accurate method for predicting sound pressure levels in enclosures such as aircraft fuselages. Asymptotic Modal Analysis (AMA) is the method under investigation. AMA is derived from classical modal analysis (CMA) by considering the asymptotic limit of the sound pressure level as the number of acoustic and/or structural modes approaches infinity. Using AMA, results identical to those of Statistical Energy Analysis (SEA) were obtained for the spatially-averaged sound pressure levels in the interior. AMA is systematically derived from CMA and therefore the degree of generality of the end result can be adjusted through the choice of appropriate simplifying assumptions. For example, AMA can be used to obtain local sound pressure levels at particular points inside the enclosure, or to include the effects of varying the size and/or location of the sound source. AMA theoretical results were compared with CMA theory and also with experiment for the case where the structural-acoustic enclosure is a rectangular cavity with part of one wall flexible and vibrating, while the rest of the cavity is rigid.

Dowell, Earl H.

Performance of statistical energy analysis

Statistical energy analysis (SEA) methods have been developed for high frequency modal analyses on random vibration environments. These SEA methods are evaluated by comparing analytical predictions to test results. Simple test methods are developed for establishing SEA parameter values. Techniques are presented, based on the comparison of the predictions with test values, for estimating SEA accuracy as a function of frequency for a general structure.

Davis, R. F.

Recent Advances in Statistical Energy Analysis

Statistical Energy Analysis (SEA) has traditionally been developed using modal summation and averaging approach, and has led to the need for many restrictive SEA assumptions. The assumption of 'weak coupling' is particularly unacceptable when attempts are made to apply SEA to structural coupling. It is now believed that this assumption is more a function of the modal formulation rather than a necessary formulation of SEA. The present analysis ignores this restriction and describes a wave approach to the calculation of plate-plate coupling loss factors. Predictions based on this method are compared with results obtained from experiments using point excitation on one side of an irregular six-sided box structure. Conclusions show that the use and calculation of infinite transmission coefficients is the way forward for the development of a purely predictive SEA code.

K H Heron

Asymptotic modal analysis and statistical energy analysis of an acoustic cavity

A basic asymptotic theory for structural wall/acoustic cavity interaction is presented, and the analysis is illustrated with examples of the acoustic cavity response to a prescribed wall motion. Although, when spatially averaged, the classical modal analysis (CMA) response approaches the asymptotic modal analysis (AMA) response more rapidly as the number of modes increases, it is shown that information about local response intensification is lost in the averaging process. A larger bandwidth at a given center frequency is found to contain more excited modes than a smaller bandwidth; however, the AMA is slightly more accurate in the smaller bandwidth. All AMA asymptotes were shown to be approached from below by a CMA with fixed bandwidth and increasing center frequency.

Kubota, Y.

Statistical energy analysis computer program, user's guide

A high frequency random vibration analysis, (statistical energy analysis (SEA) method) is examined. The SEA method accomplishes high frequency prediction of arbitrary structural configurations. A general SEA computer program is described. A summary of SEA theory, example problems of SEA program application, and complete program listing are presented.

Trudell, R. W.

Statistical Energy Analysis Program

Statistical Energy Analysis (SEA) is powerful tool for estimating highfrequency vibration spectra of complex structural systems and incorporated into computer program. Basic SEA analysis procedure divided into three steps: Idealization, parameter generation, and problem solution. SEA computer program written in FORTRAN V for batch execution.

Ferebee, R. C.

Treated cabin acoustic prediction using statistical energy analysis

The application of statistical energy analysis (SEA) to the modeling and design of helicopter cabin interior noise control treatment is demonstrated. The information presented here is obtained from work sponsored at NASA Langley for the development of analytic modeling techniques and the basic understanding of cabin noise. Utility and executive interior models are developed directly from existing S-76 aircraft designs. The relative importance of panel transmission loss (TL), acoustic leakage, and absorption to the control of cabin noise is shown using the SEA modeling parameters. It is shown that the major cabin noise improvement below 1000 Hz comes from increased panel TL, while above 1000 Hz it comes from reduced acoustic leakage and increased absorption in the cabin and overhead cavities.

Yoerkie, Charles A.

Heat-Energy Analysis for Solar Receivers

Heat-energy analysis program (HEAP) solves general heat-transfer problems, with some specific features that are "custom made" for analyzing solar receivers. Can be utilized not only to predict receiver performance under varying solar flux, ambient temperature and local heat-transfer rates but also to detect locations of hotspots and metallurgical difficulties and to predict performance sensitivity of neighboring component parameters.

Lansing, F. L.

Prediction and measurement of the proportionality constant in statistical energy analysis of structures.

The fundamental equation of statistical energy analysis (SEA) states that the average power flow between two coupled vibrating systems is proportional to the difference in their average modal energies. Under certain circumstances it is possible to estimate the proportionality constant by modifying system boundary conditions on the separated systems and calculating or measuring changes in the systems. Newland's estimate, based upon blocking part of the system, is reexamined, and limitations are discussed. Three alternative methods which circumvent blocking are presented. These were applied to predict power flow in experiments on coupled beams and on coupled plates wherein power flow through the coupling was measured directly as a product of force times velocity. The measurements support the fundamental SEA relation, including the null power point where the average modal energies are equal.

Lotz, R.

A mechanical energy analysis of gait initiation

The analysis of gait initiation (the transient state between standing and walking) is an important diagnostic tool to study pathologic gait and to evaluate prosthetic devices. While past studies have quantified mechanical energy of the body during steady-state gait, to date no one has computed the mechanical energy of the body during gait initiation. In this study, gait initiation in seven normal male subjects was studied using a mechanical energy analysis to compute total body energy. The data showed three separate states: quiet standing, gait initiation, and steady-state gait. During gait initiation, the trends in the energy data for the individual segments were similar to those seen during steady-state gait (and in Winter DA, Quanbury AO, Reimer GD. Analysis of instantaneous energy of normal gait. J Biochem 1976;9:253-257), but diminished in amplitude. However, these amplitudes increased to those seen in steady-state during the gait initiation event (GIE), with the greatest increase occurring in the second step due to the push-off of the foundation leg. The baseline level of mechanical energy was due to the potential energy of the individual segments, while the cyclic nature of the data was indicative of the kinetic energy of the particular leg in swing phase during that step. The data presented showed differences in energy trends during gait initiation from those of steady state, thereby demonstrating the importance of this event in the study of locomotion.

Leg/physiology

Power flow as a complement to statistical energy analysis and finite element analysis

Present methods of analysis of the structural response and the structure-borne transmission of vibrational energy use either finite element (FE) techniques or statistical energy analysis (SEA) methods. The FE methods are a very useful tool at low frequencies where the number of resonances involved in the analysis is rather small. On the other hand SEA methods can predict with acceptable accuracy the response and energy transmission between coupled structures at relatively high frequencies where the structural modal density is high and a statistical approach is the appropriate solution. In the mid-frequency range, a relatively large number of resonances exist which make finite element method too costly. On the other hand SEA methods can only predict an average level form. In this mid-frequency range a possible alternative is to use power flow techniques, where the input and flow of vibrational energy to excited and coupled structural components can be expressed in terms of input and transfer mobilities. This power flow technique can be extended from low to high frequencies and this can be integrated with established FE models at low frequencies and SEA models at high frequencies to form a verification of the method. This method of structural analysis using power flo and mobility methods, and its integration with SEA and FE analysis is applied to the case of two thin beams joined together at right angles.

Cuschieri, J. M.

Vibration transmission through rolling element bearings. IV - Statistical energy analysis

A theoretical broadband coupling-loss factor is developed analytically for use in the statistical energy analysis (SEA) of a shaft-bearing-plate system. The procedure is based on the solution of the boundary-value problem at the plate-bearing interface and incorporates a bearing-stiffness matrix developed by the authors. Three examples are utilized to illustrate the SEA incorporating the coupling-loss factor including: (1) a shaft-bearing-plate system; (2) a plate-cantilevered beam; and (3) a circular-shaft-bearing plate. The coupling-loss factor in the case of the thin plate-cantilevered beam is found to be more accurate than that developed by Lyon and Eichler (1964). The coupling-loss factor is described for the bearing system and extended to describe the mean-square vibratory response of a rectangular plate. The proposed techniques are of interest to the study of vibration and noise in rotating machinery such as gearboxes.

Lim, T. C.

Statistical energy analysis of a geared rotor system

The vibroacoustic response of a generic geared rotor system is analyzed on an order of magnitude basis utilizing an approximate statistical energy analysis method. This model includes a theoretical coupling loss factor for a generic bearing component, which properly accounts for the vibration transmission through rolling element bearing. A simplified model of a NASA test stand that assumes vibratory energy flow from the gear mesh source to the casing through shafts and bearings is given as an example. Effects of dissipation loss factor and gearbox radiation efficiency models are studied by comparing predictions with NASA test results.

Lim, Teik C.

Prediction of interior noise due to random acoustic or turbulent boundary layer excitation using statistical energy analysis

The feasibility of predicting interior noise due to random acoustic or turbulent boundary layer excitation was investigated in experiments in which a statistical energy analysis model (VAPEPS) was used to analyze measurements of the acceleration response and sound transmission of flat aluminum, lucite, and graphite/epoxy plates exposed to random acoustic or turbulent boundary layer excitation. The noise reduction of the plate, when backed by a shallow cavity and excited by a turbulent boundary layer, was predicted using a simplified theory based on the assumption of adiabatic compression of the fluid in the cavity. The predicted plate acceleration response was used as input in the noise reduction prediction. Reasonable agreement was found between the predictions and the measured noise reduction in the frequency range 315-1000 Hz.

Grosveld, Ferdinand W.

HVAC modifications and computerized energy analysis for the Operations Support Building at the Mars Deep Space Station at Goldstone

The key heating, ventilation, and air-conditioning (HVAC) modifications implemented at the Mars Deep Space Station's Operation Support Building at Jet Propulsion Laboratories (JPL) in order to reduce energy consumption and decrease operating costs are described. An energy analysis comparison between the computer simulated model for the building and the actual meter data was presented. The measurement performance data showed that the cumulative energy savings was about 21% for the period 1979 to 1981. The deviation from simulated data to measurement performance data was only about 3%.

Halperin, A.