Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrothermal simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Experimentation in the low-density plume of a simulated electrothermal thruster for computer code validation

Pressures and flow angles are measured in the plume of a 20 deg half-angle, conical nozzle in vacuum with Pitot tubes and conical probes. The area of measurement in the plume ranges from the nozzle exit plane to 480 mm axially downstream and from the plume centerline to 60 mm radially. The nozzle has an exit-to-throat area ratio of 100:1 and a throat diameter of 3.2 mm. The nozzle flow exhausts to a vacuum of order 10(exp -2) Pa to simulate a resistojet (an electrothermal rocket of less than 1 N of thrust) operating in space. Experimental data are given for flows of nitrogen at 55 and 68 mg/s, stagnation temperatures between 695 and 921 K, and stagnation pressures ranging from 5600 to 7100 Pa. Data are also given for argon at a rate of 68 mg/s, a stagnation temperature of 648 K, and stagnation pressures of 4500, 4750, and 4770 Pa. Measurements in the nitrogen plume are compared with computational results from a direct-simulation Monte Carlo method.

Meissner, Dana L.↗

Numerical simulation of electrothermal de-icing systems

Transient simulations of de-icing of composite aircraft components by electrothermal heating have been computed for both one and two-dimensional rectangular geometries. The implicit Crank-Nicolson formulation is used to insure stability of the finite-differenced heat conduction equations and the phase change in the ice layer is simulated using the Enthalpy method. Numerical solutions illustrating de-icer performance for various composite aircraft blades and environmental conditions are presented. Comparisons are made with previous studies and with available experimental data. Initial results using a coordinate mapping technique to describe the actual blade geometry are discussed.

De Witt, K. J.↗

Numerical simulation of an electrothermal deicer pad

A numerical simulation is developed to investigate the removal of ice from composite aircraft blades by means of electrothermal deicing. The model considers one dimensional, unsteady state heat transfer in the composite blade-ice body. The heat conduction equations are approximated by using the Crank-Nicolson finite difference scheme, and the phase change in the ice layer is handled using the Enthalpy method. To solve the system of equations which result, Gauss-Seidel iteration is used. The simulation computes the temperature profile in the composite blade-ice body, as well as the movement of the ice-water interface, as a function of time. This information can be used to evaluate deicer performance. The simulation can also be used to solve a variety of other heat conduction problems involving composite bodies.

Marano, J. J.↗

Validation of NASA Thermal Ice Protection Computer Codes: Program Overview - Part 1

The Icing Technology Branch at NASA Lewis has been involved in an effort to validate two thermal ice protection codes developed at the NASA Lewis Research Center. LEWICE/Thermal (electrothermal deicing & anti-icing), and ANTICE (hot-gas & electrothermal anti-icing). The Thermal Code Validation effort was designated as a priority during a 1994 'peer review' of the NASA Lewis Icing program, and was implemented as a cooperative effort with industry. During April 1996, the first of a series of experimental validation tests was conducted in the NASA Lewis Icing Research Tunnel(IRT). The purpose of the April 96 test was to validate the electrothermal predictive capabilities of both LEWICE/Thermal, and ANTICE. A heavily instrumented test article was designed and fabricated for this test, with the capability of simulating electrothermal de-icing and anti-icing modes of operation. Thermal measurements were then obtained over a range of test conditions, for comparison with analytical predictions. This paper will present an overview of the test, including a detailed description of: (1) the validation process; (2) test article design; (3) test matrix development; and (4) test procedures. Selected experimental results will be presented for de-icing and anti-icing modes of operation. Finally, the status of the validation effort at this point will be summarized. Detailed comparisons between analytical predictions and experimental results are contained in the following two papers: 'Validation of NASA Thermal Ice Protection Computer Codes: Part 2- The Validation of LEWICE/Thermal' and 'Validation of NASA Thermal Ice Protection Computer Codes: Part 3-The Validation of ANTICE'

Miller, Dean↗

Efficient numerical simulation of an electrothermal de-icer pad

In this paper, a new approach to calculate the transient thermal behavior of an iced electrothermal de-icer pad was developed. The method of splines was used to obtain the temperature distribution within the layered pad. Splines were used in order to create a tridiagonal system of equations that could be directly solved by Gauss elimination. The Stefan problem was solved using the enthalpy method along with a recent implicit technique. Only one to three iterations were needed to locate the melt front during any time step. Computational times were shown to be greatly reduced over those of an existing one dimensional procedure without any reduction in accuracy; the curent technique was more than 10 times faster.

Roelke, R. J.↗

Validation of NASA Thermal Ice Protection Computer Codes: The Validation of Antice - Part 3

An experimental program was generated by the Icing Technology Branch at NASA Glenn Research Center to validate two ice protection simulation codes: (1) LEWICE/Thermal for transient electrothermal de-icing and anti-icing simulations, and (2) ANTICE for steady state hot gas and electrothermal anti-icing simulations. An electrothermal ice protection system was designed and constructed integral to a 36 inch chord NACA0012 airfoil. The model was fully instrumented with thermo-couples, RTD'S, and heat flux gages. Tests were conducted at several icing environmental conditions during a two week period at the NASA Glenn Icing Research Tunnel. Experimental results of running-wet and evaporative cases were compared to the ANTICE computer code predictions and are presented in this paper.

Al-Khalil, Kamel M.↗

Predicted electrothermal deicing of aircraft blades

A finite difference method is presented for the transient two-dimensional simulation of an electrothermal de-icer pad of an aircraft wing or blade. The irregular geometry of the composite ice laden blade is handled by use of a body fitted coordinate transformation. By this approach the various blade layers are mapped into a set of stacked rectangular strips in which the numerical solution takes place. Several heat conduction examples are presented in order to demonstrate the accuracy of the numerical procedure. Ice melting time predictions are made and compared to earlier predictions where possible. Finally, a new graphical presentation of thermal results is shown.

Keith, T. G., Jr.↗

A comparison of numerical methods for the prediction of two-dimensional heat transfer in an electrothermal deicer pad

Transient, numerical simulations of the deicing of composite aircraft components by electrothermal heating have been performed in a 2-D rectangular geometry. Seven numerical schemes and four solution methods were used to find the most efficient numerical procedure for this problem. The phase change in the ice was simulated using the Enthalpy method along with the Method for Assumed States. Numerical solutions illustrating deicer performance for various conditions are presented. Comparisons are made with previous numerical models and with experimental data. The simulation can also be used to solve a variety of other heat conduction problems involving composite bodies.

Deicer↗

A numerical simulation of the full two-dimensional electrothermal de-icer pad

The ability to predict the time-temperature history of electrothermal de-icer pads is important in the subsequent design of improved and more efficient versions. These de-icer pads are installed near the surface of aircraft components, for the specific purpose of removing accreted ice. The proposed numerical model can incorporate the full 2-D geometry through a section of a region (i.e., section of an airfoil), that current 1-D numerical codes are unable to do. Thus, the effects of irregular layers, curvature, etc., can now be accounted for in the thermal transients. Each layer in the actual geometry is mapped via a body-fitted coordinate transformation into uniform, rectangular computational grids. The relevant heat transfer equations are transformed and discretized. To model the phase change that might occur in any accreted ice, in an enthalpy formulation the phase change equations are likewise transformed and discretized. The code developed was tested against numerous classical numerical solutions, as well as against experimental de-icing data on a UH1H rotor blade obtained from the NASA Lewis Research Center. The excellent comparisons obtained show that this code can be a useful tool in predicting the performance of current de-icer models, as well as in the designing of future models.

Masiulaniec, Konstanty C.↗

Analytical and Experimental Characterization of a Linear-Array Thermopile Scanning Radiometer for Geo-Synchronous Earth Radiation Budget Applications

The Thermal Radiation Group, a laboratory in the department of Mechanical Engineering at Virginia Polytechnic Institute and State University, is currently working towards the development of a new technology for cavity-based radiometers. The radiometer consists of a 256-element linear-array thermopile detector mounted on the wall of a mirrored wedgeshaped cavity. The objective of this research is to provide analytical and experimental characterization of the proposed radiometer. A dynamic end-to-end opto-electrothermal model is developed to simulate the performance of the radiometer. Experimental results for prototype thermopile detectors are included. Also presented is the concept of the discrete Green's function to characterize the optical scattering of radiant energy in the cavity, along with a data-processing algorithm to correct for the scattering. Finally, a parametric study of the sensitivity of the discrete Green's function to uncertainties in the surface properties of the cavity is presented.

Sorensen, Ira J.↗

A numerical and experimental investigation of electrochemical aircraft deicing

This study was composed of three parts. The first part involved the extension of an existing transient two dimensional numerical code for an electrothermal deicer so that it would simulate the situation where a variable thickness ice layer existed at the outer surface. The Enthalpy Method was used to simulate the phase change, and Gauss-Seidel iteration was used to solve the resulting system of finite difference equations. A set of criteria were developed for determining when a variable thickness ice layer had an effect on deicer performance. The second part was the acquisition and analysis of experimental data. The test model was a section of a Bell UH-1H helicopter blade equipped with an electrothermal deicer. A total of fifty-two thermocouples were utilized to document the thermal response of the blade and decier assembly. In the deicing runs, the experimental temperature response data clearly showed when melting, shedding or refreezing occurred. The tests illustrated that the criterion for shedding in the three cases where it did occur was that the abrasion shield interface temperature was 32 to 34 F. The third part concerned the validation of a one dimensional transient thermal model of an electrothermal deicer by comparison of the predictions with the experimental data. The Enthalpy Method was found to effectively model the phase change which occurred, and the ice shedding algorithm employed in the simulation was also evaluated.

Leffel, K. L.↗

Evaluation of candidate working fluid formulations for the electrothermal-chemical wind tunnel

A new hypersonic test facility which can simulate conditions typical of atmospheric flight at Mach numbers up to 20 is currently under study at the NASA/LaRC Hypersonic Propulsion Branch. In the proposed research, it was suggested that a combustion augmented electrothermal wind tunnel concept may be applied to the planned hypersonic testing facility. The purpose of the current investigation is to evaluate some candidate working fluid formulations which may be used in the chemical-electrothermal wind. The efforts in the initial phase of this research were concentrated on acquiring the code used by GASL to model the electrothermal wind tunnel and testing it using the conditions of GASL simulation. The early version of the general chemical kinetics code (GCKP84) was obtained from NASA and the latest updated version of the code (LSENS) was obtained from the author Dr. Bittker. Both codes are installed on a personal computer with a 486 25 MHz processor and 16 Mbyte RAM. Since the available memory was not sufficient to debug LSENS, for the current work GCKP84 was used.

Akyurtlu, Jale F.↗

A numerical and experimental investigation of electrothermal aircraft deicing

Experimental data were obtained for the deicing characteristics of a stationary UH-1H helicopter blade which had been fitted with an electrothermal deicer assembly. The tests were run in the NASA Lewis Icing Research Tunnel, and yielded transient temperature responses for the substrate, heater and abrasion shield at selected positions around the blade. The data at the abrasion shield-ice interface clearly documented when melting, shedding or refreezing occurred. Comparisons were made between the experimental data and a one-dimensional numerical model. The agreement was generally very good, with the simulations being shown to be capable of predicting the transient temperature responses along with phase change and ice shedding. At many blade positions, the model was capable of accurately simulating the thermal response of the electrothermal deicer assembly.

Leffel, K.↗

Analysis of Aluminum-Nitride SOI for High-Temperature Electronics

We use numerical simulation to investigate the high-temperature (up to 500K) operation of SOI MOSFETs with Aluminum-Nitride (AIN) buried insulators, rather than the conventional silicon-dioxide (SiO2). Because the thermal conductivity of AIN is about 100 times that of SiO2, AIN SOI should greatly reduce the often severe self-heating problem of conventional SOI, making SOI potentially suitable for high-temperature applications. A detailed electrothermal transport model is used in the simulations, and solved with a PDE solver called PROPHET In this work, we compare the performance of AIN-based SOI with that of SiO2-based SOI and conventional MOSFETs. We find that AIN SOI does indeed remove the self-heating penalty of SOL However, several device design trade-offs remain, which our simulations highlight.

Biegel, Bryan A.↗

Overview of numerical codes developed for predicted electrothermal deicing of aircraft blades

An overview of the deicing computer codes that have been developed at the University of Toledo under sponsorship of the NASA-Lewis Research Center is presented. These codes simulate the transient heat conduction and phase change occurring in an electrothermal deicier pad that has an arbitrary accreted ice shape on its surface. The codes are one-dimensional rectangular, two-dimensional rectangular, and two-dimensional with a coordinate transformation to model the true blade geometry. All modifications relating to the thermal physics of the deicing problem that have been incorporated into the codes will be discussed. Recent results of reformulating the codes using different numerical methods to increase program efficiency are described. In particular, this reformulation has enabled a more comprehensive two-dimensional code to run in much less CPU time than the original version. The code predictions are compared with experimental data obtained in the NASA-Lewis Icing Research Tunnel with a UH1H blade fitted with a B. F. Goodrich electrothermal deicer pad. Both continuous and cyclic heater firing cases are considered. The major objective in this comparison is to illustrate which codes give acceptable results in different regions of the airfoil for different heater firing sequences.

Keith, Theo G.↗