Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrostatic analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Experimental tests of a toroidal electrostatic analyzer

A toroidal electrostatic analyzer of a design suitable for space plasma instrumentation has been constructed and tested. Experimental results are compared with second-order ion optical theory and are in good agreement. Verifying the ion optics of the toroid was simplified by use of a position-sensing microchannel-plate detector mounted on a positioning system with three translational degrees of freedom located at the toroid exit. The toroidal analyzer described here is the first optical element in a fully toroidal mass spectrograph intended for analysis of kilovolt magnetospheric plasmas.

Young, D. T.↗

A rocket-borne electrostatic analyzer for measurement of energetic particle flux

A rocket-borne electrostatic analyzer experiment is described. It is used to measure energetic particle flux (0.9 to 14 keV) in the nighttime midlatitude E region. Energetic particle precipitation is believed to be a significant nighttime ionization source, particularly during times of high geomagnetic activity. The experiment was designed for use in the payload of a Nike Apache sounding rocket. The electrostatic analyzer employs two cylindrical parallel plates subtending a central angle of 90 deg. The voltage waveform supplied to the plates is a series of steps synchronized to the spin of the payload during flight. Both positive and negative voltages are provided, extending the detection capabilities of the instrument to both electrons and protons (and positive ions). The development, construction and operation of the instrument is described together with a preliminary evaluation of its performance in a rocket flight.

Pozzi, M. A.↗

The integrated miniaturized electrostatic analyzer: A space plasma environment sensor

The integrated Miniaturized Electrostatic Analyzer (iMESA) was a satellite-based ionospheric sensor that operated on NASA’s Space Test Program Satellite (STPSat-3) from December 2013 to July 2019. The instrument’s scientific objective was to (1) measure the plasma density in low Earth orbit, (2) measure the plasma temperature in low Earth orbit, and (3) quantify the spacecraft potential with respect to the ambient plasma potential in the ionosphere. iMESA sampled the ionosphere every 10 s by measuring the ion current density through the ESA as a result of the motion of the spacecraft through the plasma. Current density spectra were transmitted to the ground where they were post-processed into ion density spectra and then analyzed numerically to determine the ion density, ion temperature, and spacecraft potential. This article discusses the instrument design and simulation, the determination of a geometric factor, and data processing procedures and evaluates the final data product with regard to the mission success criteria. Here, the ion density and ion temperature captured by the iMESA instrument are on the same order and range as the values predicted in the literature. The spacecraft potential was also quantified. The conclusion after the evaluation of the instrument’s data product is that the scientific mission is successful on all three points.

47 OTHER INSTRUMENTATION↗

Holistic Numerical Calibration of the iMESA Electrostatic Analyzer

A drifted Maxwellian velocity distribution is the most common model used to interpret the data from low-energy charged-particle instruments onboard spacecraft that are used to investigate the ambient plasma environment in the low Earth orbit (LEO). An original method is presented for determining the flow parameters (density, temperature, and flow energy) of such a distribution from the output of the integrated miniaturized electrostatic analyzer, which has been successfully flown on several LEO missions. Rather than attempting to deconvolve from the on-orbit data the analyzer’s response to an ideal, monoenergetic input, numerical simulation is used to predict and parameterize the response of the device to an input distribution that includes an isotropic, non-zero temperature, yielding a straightforward method for extracting the flow parameters from the spacecraft data. The method is computationally simple enough to be incorporated into a robust algorithm suitable for rapid batch processing or real-time analysis of data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The geometric factor of a cylindrical plate electrostatic analyzer

A method for calculating the geometric factor of cylindrical plate electrostatic energy analyzers with various detector geometries is described. The effects of the fringe-field are estimated. For a special simple case an exact geometric factor is calculated enabling an estimate of the inaccuracies of the approximations used in other cases. The results of some calculations are presented and a simple approximate expression for the geometric factor is deduced.

Johnstone, A. D.↗

The geometric factor of a cylindrical plate electrostatic analyzer.

A method for calculating the geometric factor of cylindrical plate electrostatic energy analyzers with various detector geometries is described. The effects of the fringe field are estimated. For a special simple case an exact geometric factor is calculated, enabling an estimate to be made of the inaccuracies of the approximations used in other cases. The results of some calculations are presented, and a simple approximate expression for the geometric factor is deduced.

Johnstone, A. D.↗

Primary electron spectrometer, 18:63 UE: Electrostatic analyzer description and energy spectrum determination

The primary electron spectrometer used to detect auroral electrons on sounding rocket 18:63 UE is described. The spectrometer used exponentially decaying positive and negative voltages applied to spherical deflection plates for energy analysis. A method for determining the analyzer response which does not require the assumptions that the ratio of plate separation to mean radius, the entrance or the exit apertures are small is described. By comparison with experiment it is shown that the effect of neither entrance nor exit collimation can be ignored. The experimental and calculated values of the limiting orbits agree well. A non-iterative technique of unfolding the electron differential energy spectrum is described. This method does not require the usual assumption of a flat or histogram-type energy spectrum. The unfolded spectra using both this technique and one which assumes a flat spectrum are compared to actual input spectra. This technique is especially useful in analyzing peaked auroral electron energy spectra.

Pongratz, M. B.↗

Electron energy analyzer

Electrostatic deflection analyzer with three spherically concentric grids allows production of electrons within a small volume at the center of the inner sphere. By applying a retarding potential between the middle and inner spheres, the energies of the electrons can be measured.

Samson, J. A. R.↗

Compact wide-aperture hyperbolic analyzers

Compact electrostatic analyzers that employ a new geometry are described. They accept collimated beams of ions through relatively wide (non-slit-like) inlet apertures and focus them at various locations, depending on the ion energy per charge, along rectangular position-sensing detectors. Each analyzer has a dynamic range of 10 or more for a fixed deflection voltage. The focal line width at a given energy is a small fraction of the inlet aperture width, and the focal lines are approximately coplanar.

Curtis, C. C.↗

The Geometric Factor of Electrostatic Plasma Analyzers: A Case Study from the Fast Plasma Investigation for the Magnetospheric Multiscale mission

We report our findings comparing the geometric factor (GF) as determined from simulations and laboratory measurements of the new Dual Electron Spectrometer (DES) being developed at NASA Goddard Space Flight Center as part of the Fast Plasma Investigation on NASA's Magnetospheric Multiscale mission. Particle simulations are increasingly playing an essential role in the design and calibration of electrostatic analyzers, facilitating the identification and mitigation of the many sources of systematic error present in laboratory calibration. While equations for laboratory measurement of the Geometric Factpr (GF) have been described in the literature, these are not directly applicable to simulation since the two are carried out under substantially different assumptions and conditions, making direct comparison very challenging. Starting from first principles, we derive generalized expressions for the determination of the GF in simulation and laboratory, and discuss how we have estimated errors in both cases. Finally, we apply these equations to the new DES instrument and show that the results agree within errors. Thus we show that the techniques presented here will produce consistent results between laboratory and simulation, and present the first description of the performance of the new DES instrument in the literature.

Magnetospheric Multiscale Mission↗

Combined Velocity/Charge-To-Mass-Ratio Analyzer

Instrument analyzes ions according to velocity and ratio of mass to electric charge. State-of-the-art combination of two instruments: time-of-flight analyzer and electrostatic analyzer functioning as mass spectrometer. Features include compactness, light weight, and low power. Terrestrial versions useful in chemical analysis, chromatography, and analysis of plasmas.

Chutjian, Ara↗