Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic filters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Spectral emission properties of a nitrogen-doped diamond (001) photocathode: Hot electron transport and transverse momentum filtering

The electron emission properties of a single-crystal nitrogen-doped diamond(001) photocathode inserted in a 10 kV DC photoelectron gun are determined using a tunable (235–410 nm) ultraviolet laser radiation source for photoemission from both the back nitrogen-doped substrate face and the front homoepitaxially grown and undoped diamond crystal face. Here, the measured spectral trends of the mean transverse energy and quantum efficiency of the emitted electrons are both anomalous and nonmonotonic, but are shown to be consistent with (i) the known physics of electron photoexcitation from the nitrogen substitution states into the conduction bands of diamond, (ii) the energy position and dispersion characteristics of the conduction bands of diamond in the (001) emission direction, (iii) the effective electron affinity of the crystal faces, (iv) the strong electron-(optical)phonon coupling in diamond, and (v) the associated hot electron transport dynamics under energy equipartition with the optical phonons. Notably, the observed hot electron emission is shown to be restricted parallel to the photocathode surface by the low transverse effective masses of the emitting band states—a transverse momentum filtering effect.

36 MATERIALS SCIENCE↗

Sub-1K Cold-Electron Quantum Well Switching at Room Temperature

Quantum states can provide means to systematically manipulate the transport of electrons. Here, in this study, we present electron transport across quasi-bound states of two heterogeneous quantum wells (QWs), where the transport of thermally excited electrons is blocked or enabled depending on the relative positions of the two quasi-bound states, with an abrupt current onset occurring when the two QW states align. The QW switch comprises a source (Cr), QW1 (Cr 2 O 3 ), QW2 (SnO x , x < 2), a tunneling barrier (SiO 2 ), and a drain (Si), where the effective electron mass of QW1 (m* QW1 ) is selected to be larger than QW2 (m* QW2 ). The current-voltage (I-V) measurements of the fabricated devices show abrupt current onsets, with the current transition occurring within 0.25 mV, corresponding to an effective electron temperature of 0.8 K at room temperature. Since transistor power consumption is fundamentally tied to effective electron temperature, this sub-1K cold-electron QW switching holds promise for highly energy-efficient computing.

Fermi−Dirac thermal smearing↗

Improved noise performance from the next-generation buried-channel p-MOSFET SiSeROs

The Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. In our earlier work, we characterized a number of first prototype SiSeROs with the MOSFET transistor channels at the surface layer. An equivalent noise charge (ENC) of around 15 electrons root mean square (RMS) was obtained. In this work, we examine the first buried-channel SiSeRO. Here we have achieved substantially improved noise performance of around 4.5 electrons root mean square (RMS) and a full width half maximum (FWHM) energy resolution of 132 eV at 5.9 keV, for a readout speed of 625 kpixel/s. We also discuss how digital filtering techniques can be used to further improve the SiSeRO noise performance. Additional measurements and device simulations will be essential to further mature the SiSeRO technology. This new device class presents an exciting new technology for the next-generation astronomical X-ray telescopes requiring fast, low-noise, radiation-hard megapixel imagers with moderate spectroscopic resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Reconstruction of 2D line-integrated electron density using angular filter refractometry and a fast marching Eikonal solver

Refraction of an optical probe beam by a plasma can be measured with angular filter refractometry (AFR), which produces an image of the beam’s 2D spatial profile that contains intensity contours corresponding to curves of constant refraction angle. Further analysis is required to reconstruct the underlying line-integrated electron density. Most prior efforts to calculate density from AFR data have been limited to 1D analysis or forward-fitting techniques. Here, in this paper, we detail the use of a fast-marching Eikonal solver to directly invert AFR data and obtain the full 2D line-integrated electron density. The analysis method is first verified with synthetic data and then applied to experimental measurements of single and colliding plasma plumes collected at the OMEGA EP Laser Facility. The calculated densities agree with 1D results and are shown to be consistent with the original AFR measurements via forward modeling. We also discuss ways to improve the precision of this technique.

McCluskey, B. [Princeton Univ., NJ (United States)↗

Liquid Interfacial Electron Microscopy Identifies Nanogalvanic Corrosion in Pearlitic Steel

The nanoscale mechanisms of localized corrosion in low carbon steels have remained elusive due to the complexity of studying the degradative material behavior at nanoscale solid-liquid interfaces. We identified various steps in the nanogalvanic corrosion processes using in-situ liquid-cell scanning transmission electron microscopy (STEM) using a microfluidic holder by Hummingbird Scientific. Initial work, performed at low magnification, identified the initiation point on a 1018 low-carbon steel surface. This initiation point was determined to be a triple junction of two ferrite grains bridging a cementite grain in contact with a baseline electrolyte of 6 uM CO2 dissolved in a buffered (2.78 uM Na2SO4) aqueous solution, pH 6.1. The pre-etched low-carbon steel surface was prepared using focused ion beam lift-out procedures to extract a cross-section of the low-carbon steel surface, which then was thinned to about 150 nm and transferred to a SiN membrane microfluidic window. The transfer was made using a lift-out needle to attach the low-carbon steel lamella to the corner of the SiN window, and then Pt/C deposition held the lamella in contact with the window while it was released from the lift out needle. To identify the triple point on the low carbon steel lamella, prior to attachment on the SiN window, the sample was characterized for compositional variations with energy dispersive x-ray spectroscopy mapping, grain orientation and phase mapping with precession electron diffraction, and thickness mapping with energy filtered transmission electron microscopy. This pre-characterization prior to the in-situ experiment provided a map of the multiphase and multigrain structure, where the in-situ liquid cell imaging provided a clear understanding of the initiation point on the sample. These data were cross-correlated to paint a holistic picture of the triple junction site, enabling low electron-fluence in-situ snapshot imaging to avoid dominating the native corrosion reactions with effects from the incident electron beam. This initial result identified that localized, nanogalvanic corrosion at the phase interface was the dominant corrosion process in the low-carbon steel, so we next targeted the observation of an array of these nanogalvanic features phase boundaries in a pearlite grain. Near-surface ferrite/cementite phase interfaces that typify pearlitic low-carbon steel were extracted, pre-characterized, and imaged for the in-situ corrosion processes. The sample was a cross-section from a pearlite grain, with alternating ferrite and cementite grains that extended microns down from the pre-etched low-carbon steel pipe surface. After contact with a buffered aqueous solution, the phase boundaries between the ferrite and cementite began to dissolve, with observable material loss and thickness changes in the dark-field and bright-field STEM images. Within minutes, the corrosion front proceeded deeper into the material, claiming a thin layer of ferrite around all exposed phase boundaries before progressing laterally into the ferrite matrix, converting the ferrite to corrosion product normal to each buried cementite grain. Formation of the corrosion product causes a volumetric expansion, creating a lateral wedging force that mechanically ejects the cementite grains from their grooves and leaves behind percolation channels into the steel substructure. Rapid and deleterious, this nanogalvanic corrosion pathway represents an important target for understanding and preventing run-away degradation in this common building material. Observation of this corrosion mechanism was enabled by the combination of pre-characterization using standard structural, grain, and compositional analysis in the TEM, which provides maps for understanding the reaction propagation captured in low-dose, in-situ, liquid-cell STEM.

corrosion↗

Structural, Electrical, and Optical Properties of Single-Walled Carbon Nanotubes Synthesized through Floating Catalyst Chemical Vapor Deposition

Single-walled carbon nanotube (SWCNT) thin films were synthesized by using a floating catalyst chemical vapor deposition (FCCVD) method with a low flow rate (200 sccm) of mixed gases (Ar and H 2 ). SWCNT thin films with different thicknesses can be prepared by controlling the collection time of the SWCNTs on membrane filters. Transmission electron microscopy (TEM) showed that the SWCNTs formed bundles and that they had an average diameter of 1.46 nm. The Raman spectra of the SWCNT films suggested that the synthesized SWCNTs were very well crystallized. Although the electrical properties of SWCNTs have been widely studied so far, the Hall effect of SWCNTs has not been fully studied to explore the electrical characteristics of SWCNT thin films. In this research, Hall effect measurements have been performed to investigate the important electrical characteristics of SWCNTs, such as their carrier mobility, carrier density, Hall coefficient, conductivity, and sheet resistance. The samples with transmittance between 95 and 43% showed a high carrier density of 10 21– 10 23 cm –3 . The SWCNTs were also treated using Brønsted acids (HCl, HNO 3 , H 2 SO 4 ) to enhance their electrical properties. After the acid treatments, the samples maintained their p-type nature. The carrier mobility and conductivity increased, and the sheet resistance decreased for all treated samples. The highest mobility of 1.5 cm 2 /Vs was obtained with the sulfuric acid treatment at 80 °C, while the highest conductivity (30,720 S/m) and lowest sheet resistance (43 ohm/square) were achieved with the nitric acid treatment at room temperature. Different functional groups were identified in our synthesized SWCNTs before and after the acid treatments using Fourier-Transform Infrared Spectroscopy (FTIR).

36 MATERIALS SCIENCE↗

Nanoscale defect evaluation framework combining real-time transmission electron microscopy and integrated machine learning-particle filter estimation

Observation of dynamic processes by transmission electron microscopy (TEM) is an attractive technique to experimentally analyze materials’ nanoscale phenomena and understand the microstructure-properties relationships in nanoscale. Even if spatial and temporal resolutions of real-time TEM increase significantly, it is still difficult to say that the researchers quantitatively evaluate the dynamic behavior of defects. Images in TEM video are a two-dimensional projection of three-dimensional space phenomena, thus missing information must be existed that makes image’s uniquely accurate interpretation challenging. Therefore, even though they are still a clustering high-dimensional data and can be compressed to two-dimensional, conventional statistical methods for analyzing images may not be powerful enough to track nanoscale behavior by removing various artifacts associated with experiment; and automated and unbiased processing tools for such big-data are becoming mission-critical to discover knowledge about unforeseen behavior. We have developed a method to quantitative image analysis framework to resolve these problems, in which machine learning and particle filter estimation are uniquely combined. The quantitative and automated measurement of the dislocation velocity in an Fe-31Mn-3Al-3Si autunitic steel subjected to the tensile deformation was performed to validate the framework, and an intermittent motion of the dislocations was quantitatively analyzed. The framework is successfully classifying, identifying and tracking nanoscale objects; these are not able to be accurately implemented by the conventional mean-path based analysis.

36 MATERIALS SCIENCE↗

Prototype acoustic positioning system for the Pacific Ocean Neutrino Experiment

We present the design and initial performance characterization of the prototype acoustic positioning system intended for the Pacific Ocean Neutrino Experiment. It comprises novel piezo-acoustic receivers with dedicated filtering- and amplification electronics installed in P-ONE instruments and is complemented by a commercial system comprised of cabled and autonomous acoustic pingers for sub-sea installation manufactured by Sonardyne Ltd. We performed an in-depth characterization of the acoustic receiver electronics and their acoustic sensitivity when integrated into P-ONE pressure housings. These show absolute sensitivities of up to -125 dB re V2/μPa2 in a frequency range of 10–40 kHz. We furthermore conducted a positioning measurement campaign in the ocean by deploying three autonomous acoustic pingers on the seafloor, as well as a cabled acoustic interrogator and a P-ONE prototype module deployed from a ship. Using a simple peak-finding detection algorithm, we observe high accuracy in the tracking of relative ranging times at approximately 230–280 μs at distances of up to 1600 m, which is sufficient for positioning detectors in a cubic-kilometer detector and which can be further improved with more involved detection algorithms. The tracking accuracy is further confirmed by independent ranging of the Sonardyne system and closely follows the ship's drift in the wind measured by GPS. The absolute positioning shows the same tracking accuracy with its absolute precision only limited by the large uncertainties of the deployed pinger positions on the seafloor.

Data analysis↗

On-Sensor Data Filtering using Neuromorphic Computing for High Energy Physics Experiments

This work describes the investigation of neuromorphic computing-based spiking neural network (SNN) models used to filter data from sensor electronics in high energy physics experiments conducted at the High Luminosity Large Hadron Collider. We present our approach for developing a compact neuromorphic model that filters out the sensor data based on the particle's transverse momentum with the goal of reducing the amount of data being sent to the downstream electronics. The incoming charge waveforms are converted to streams of binary-valued events, which are then processed by the SNN. We present our insights on the various system design choices - from data encoding to optimal hyperparameters of the training algorithm - for an accurate and compact SNN optimized for hardware deployment. Our results show that an SNN trained with an evolutionary algorithm and an optimized set of hyperparameters obtains a signal efficiency of about 91% with nearly half as many parameters as a deep neural network.

R. Kulkarni, Shruti↗

Structural, chemical, and electronic control in Co–SiNx granular metals for high-pass filter applications

Granular metals, consisting of nanoscale conducting and insulating regions, have been studied for more than 50 years for fundamental and applied research. Granular metals exhibit non-linear conductivity vs frequency behavior, consistent with the universal power law response, and have recently been suggested for high-pass filter applications. Here, we report that cobalt–silicon nitride (Co–SiNx) granular metals with optimized sputter conditions and post-growth annealing exhibit an exceptional 109 increase in conductivity at 1 MHz compared to the DC conductivity. The improved frequency response is correlated with structural and chemical improvements examined via scanning transmission electron microscopy and x-ray photoemission spectroscopy. While we focus on improvements for high-pass filter applications, the structural, chemical, and electronic control demonstrated here will benefit a variety of granular metal and nanoparticle applications.

Annealing↗

Epoxy-based infrared filter assembly and associated fabrication devices and method

Epoxy-based inline infrared (IR) filter assembly, and manufacture and use of the same. Co-axial infrared filter assemblies comprise a substantially cylindrical filter body forming a central cavity characterized by opposing holes at each end. The filter body forms an outer conductor, and SMA connectors coupled to the opposing holes at each end of the body are electrically coupled to form an inner conductor positioned along a long axis of the filter body. An infrared absorbing material (such as castable epoxy resin) fills the central cavity of the filter body. Methods for producing the co-axial infrared filter include pressing SMA connectors into the respective ends of the filter body, electrically coupling the SMA connectors, and filling the filter body with epoxy. Electronic systems for operating a dark matter detector include a feedline comprising a coaxial filter configured to advantageously block infrared noise.

Spahn, Gabriel↗

Thomson scattering on the large plasma device

We have developed a non-collective Thomson scattering diagnostic for measurements of electron density and temperature on the Large Plasma Device. A triple grating spectrometer with a tunable notch filter is used to discriminate the faint scattering signal from the stray light. In this paper, we describe the diagnostic and its calibration via Raman scattering and present the first measurements performed with the fully commissioned system. Depending on the discharge conditions, the measured densities and temperatures range from 4.0 × 10 12 to 2.8 × 10 13 cm -3 and from 1.2 to 6.8 eV, respectively. The variation of the measurement error with plasma parameters and discharges averaged is also discussed.

47 OTHER INSTRUMENTATION↗

A 100-Mrad (Si) JFET-based Sensing and Communications System for Extreme Nuclear Instrumentation Environments

Dry cask storage is one of two storage methods approved by the U.S. Nuclear Regulatory Commission for spent fuel after removal from reactor cores. Dry casks consist of a stainless steel canister enclosed in a concrete overpack to contain the hazardous radioactive spent fuel rods and provide radiation shielding. Monitoring spent fuel storage casks is desired to ensure the safe containment of the enclosed spent fuel, but is very difficult due to the related harsh temperature and radiation environment. The sensors and associated electronics to monitor temperature, pressure, and/or radiation need to survive high temperatures and radiation doses for extended time periods. For this reason, there is a severe need for radiation-hardened electrical systems that survive well beyond the existing capabilities of commercially available radiation-rated electronic components, which have primarily been developed for space applications. Junction-gate field-effect transistor (JFET) devices are inherently radiation hardened [exceeding 100 Mrad (Si)]. Additionally, when JFETs are used as building blocks for sensing and communication electronics (i.e., oscillators, amplifiers, filters, and mixers), inherently radiation-hardened circuits can be achieved. To this end, JFET-based radiation-hardened electronics interfacing with cask-embedded sensors capable of driving modulated sensor signals through a stainless steel barrier were designed and tested at a dose rate of approximately 500 krad/h (Si) to beyond a 200-Mrad (Si) total ionizing dose. After 200 Mrad (Si), the sensor and communication circuit signals were correctly decoded at the receiver despite oscillator drift. The results from this experiment demonstrate the potential for creating more complex radiation-hardened JFET-based electrical systems for nuclear environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep learning-based noise filtering toward millisecond order imaging by using scanning transmission electron microscopy

Application of scanning transmission electron microscopy (STEM) to in situ observation will be essential in the current and emerging data-driven materials science by taking STEM’s high affinity with various analytical options into account. As is well known, STEM’s image acquisition time needs to be further shortened to capture a targeted phenomenon in real-time as STEM’s current temporal resolution is far below the conventional TEM’s. However, rapid image acquisition in the millisecond per frame or faster generally causes image distortion, poor electron signals, and unidirectional blurring, which are obstacles for realizing video-rate STEM observation. Here we show an image correction framework integrating deep learning (DL)-based denoising and image distortion correction schemes optimized for STEM rapid image acquisition. By comparing a series of distortion corrected rapid scan images with corresponding regular scan speed images, the trained DL network is shown to remove not only the statistical noise but also the unidirectional blurring. This result demonstrates that rapid as well as high-quality image acquisition by STEM without hardware modification can be established by the DL. The DL-based noise filter could be applied to in-situ observation, such as dislocation activities under external stimuli, with high spatio-temporal resolution.

47 OTHER INSTRUMENTATION↗

Implementation and optimization of the PTOLEMY transverse drift electromagnetic filter

The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium β-decay endpoint. Here, we detail the implementation and optimization methods for successful operation of the filter for electrons with a known pitch angle. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the setting of filter electrode voltages are detailed. The challenges of low-energy electron transport in cases of low field are discussed, such as the growth of the cyclotron radius with decreasing magnetic field, which puts a ceiling on filter performance relative to fixed filter dimensions. Additionally, low pitch angle trajectories are dominated by motion parallel to the magnetic field lines and introduce non-adiabatic conditions and curvature drift. To minimize these effects and maximize electron acceptance into the filter, we present a three-potential-well design to simultaneously drain the parallel and transverse kinetic energies throughout the length of the filter. These optimizations are shown, in simulation, to achieve low-energy electron transport from a 1 T iron core (or 3 T superconducting) starting field with initial kinetic energy of 18.6 keV drained to < 10 eV (< 1 eV) in about 80 cm. This result for low field operation paves the way for the first demonstrator of the PTOLEMY spectrometer for measurement of electrons near the tritium endpoint to be constructed at the Gran Sasso National Laboratory (LNGS) in Italy.

47 OTHER INSTRUMENTATION↗

Probing two-path electron quantum interference in strong-field ionization with time-correlation filtering

We report attosecond dynamics in strong-field tunnel ionization are encoded in intricate holographic patterns in the photoelectron momentum distributions. These patterns show the interference between two or more superposed quantum electron trajectories, which are defined by their ionization times and subsequent evolution in the laser field. We determine the ionization time separation between interfering pairs of electron orbits by performing a differential Fourier analysis on the measured momentum spectrum. We identify electron holograms formed by trajectory pairs whose ionization times are separated by less than a single quarter cycle, between a quarter cycle and half cycle, between a half cycle and three fourths of a cycle, and a full cycle apart. We compare our experimental results to the predictions of the Coulomb quantum orbit strong-field approximation (CQSFA) with significant success. We also time-filter the CQSFA trajectory calculations to demonstrate the validity of the technique on spectra with known time correlations. As a general analysis technique, the filter can be applied to all energy- and angularly resolved data sets to recover time correlations between interfering electron pathways, providing an important tool to analyze any strong-field ionization spectra. Moreover, it is independent of theory and can be applied directly to experiments, without the need of a direct comparison with orbit-based theoretical methods.

74 ATOMIC AND MOLECULAR PHYSICS↗

Portable diagnostic package for Thomson scattering and optical emission spectroscopy on Princeton field-reversed configuration 2 (PFRC 2)

An Advanced Research Projects Agency-Energy funded diagnostic system has been deployed to the Princeton field-reversed configuration 2 (PFRC-2) device, located at Princeton Plasma Physics Laboratory. The Portable Diagnostic Package (PDP), designed at Oak Ridge National Laboratory, allows for the measurement of Thomson Scattering (TS) for electron density and temperature and Optical Emission Spectroscopy (OES) for ion temperature, impurity density, and ion velocity. A tunable spectrometer on the PDP with three gratings provides the flexibility to measure low (1 eV) and high (1000 eV) electron temperature ranges from TS. Additionally, using a second spectrometer, the OES diagnostic can survey light emission from various ion excitation levels for wide wavelength ranges. The electron density (<2 × 10 19 m –3 ) of plasmas generated in PFRC-2 has been below the PDP TS discrimination threshold, which has made TS signal detection challenging against a high-background of laser stray light. The laser stray light was iteratively reduced by making modifications to the entrance and exit geometry on PFRC-2. Rayleigh scattering experiments on PFRC have yielded the TS discrimination sensitivity to be >1 × 10 20 m –3 for the PDP. A recently implemented narrow-band notch spectral filter that masks the second harmonic 532 nm Nd:YAG laser wavelength has increased the system’s TS light discrimination sensitivity 65 times compared to the instance when the notch filter was not implemented. The hardware implementation including design changes to the flight tubes and Brewster windows will be discussed, along with results from Rayleigh and rotational Raman scattering sensitivity analyses, which were used to establish a quantitative figure of merit on the system performance. Further, the Raman scattering calibration with the notch filter has improved the PDP electron density threshold to 1 ± 0.5 × 10 18 m –3 .

47 OTHER INSTRUMENTATION↗