Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron streaking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A THz driven split-ring resonator based ultrafast relativistic electron streak camera

The use of sub-wavelength metal structures to locally enhance high frequency electromagnetic fields, generally known as plasmonics, enables breakthrough opportunities across diverse fields of research such as nonlinear optics, biosensing, photovoltaics and others. Here we study the application of sub-wavelength metallic resonators tuned in the THz frequency range for manipulation and diagnostics of relativistic electron beams. In this work, we report on the use of a double-sided split-ring structure driven by a near single cycle THz field generated by optical rectification to impart a time-dependent angular deviation (streak) on a 4.5 MeV electron beam. Electrons passing through the small gap reveal field enhancement factors larger than 10, in good agreement with finite difference time domain simulations. This work paves the way for further application of high frequency metallic structures in compact particle accelerators such as for THz-based relativistic electron streaking at fs and sub-fs temporal resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Attosecond Electron Correlation Dynamics in Double Ionization of Benzene Probed with Two-Electron Angular Streaking

With a novel three-dimensional electron-electron coincidence imaging technique and two-electron angular streaking method, we show that the emission time delay between two electrons can be measured from tens of attoseconds to more than 1 fs. Surprisingly, in benzene, the double ionization rate decays as the time delay between the first and second electron emission increases during the first 500 as. This is further supported by the decay of the Coulomb repulsion in the direction perpendicular to the laser polarization. This result reveals that laser-induced electron correlation plays a major role in strong field double ionization of benzene driven by a nearly circularly polarized field.

74 ATOMIC AND MOLECULAR PHYSICS↗

Solid State Streak Camera Prototype Electronic Performance Testing and Characterization

Streak Cameras are an essential diagnostic tool used in shock physics and high energy density physics experiments. Such experiments require well calibrated temporally resolved diagnostics for studying events that occur in the nanosecond to microsecond time scales. Although streak cameras are among the most common detectors used within the high energy density physics community, they require frequent calibration and typically lack reproducibility in the fine detail. A solid state device with similar temporal performance characteristics could provide several advantages to current streak camera systems by utilizing discrete spatial resolution set by the sensor diodes. National Security Technologies (NSTec) has built a multi-channel solid state streak camera (SSSC) prototype, in collaboration with Sandia National Laboratories, as part of an ongoing project to develop the technology to a level competitive with analog streak cameras. The device concept and results from electronic testing of our first prototypes will be discussed in this manuscript. These measurements will be used as a base for future SSSC development projects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Attoclock Ptychography

Dedicated simulations show that the application of time-domain ptychography to angular photo-electron streaking data allows shot-to-shot reconstruction of individual X-ray free electron laser pulses. Specifically, in this study, we use an extended ptychographic iterative engine to retrieve both the unknown X-ray pulse and the unknown streak field. Here, we evaluate the quality of reconstruction versus spectral resolution, signal-to-noise and sampling size of the spectrogram.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LA-43-S-CT Post Shot

LA-43-S-CT was conducted on 12/14/15to verify the performance of the HE/Armature system intended for use in a new configuration of Ranchero Flux Compression Generators (FCGs). Subsystem tests preceded this experiment, and a synopsis of the issues explored in these is presented. The system was viewed by two fast framing cameras, an array of PDV probes, and an electronic streak camera that provide very good time and space resolution for motion of the armature during expansion. The test is described in very good detail, and the result is that the armature system is adequate for use in the Ranchero 43-S system for future physics tests.

Ranchero↗

Spectroscopic measurements of the parameters of the helium plasma jets generated in the plasma focus discharge at the PF-3 facility

The spectroscopic technique used to measure the parameters of the plasma jets generated in the plasma focus discharge and those of the plasma of the immobile gas through which these jets propagate is described. The time evolution of the intensities and shapes of spectral lines in experiments carried out with helium at the PF-3 facility was studied by means of electron-optical streak cameras. The plasma electron temperature, T ≈ 4–5 eV, was determined from the intensity ratio of two spectral lines, one of which (λ{sub 1} = 5876 Å) belongs to neutral helium, while the other (λ{sub 2} = 4686 Å), to hydrogen-like helium ions. The plasma density at different time instants was determined from the Stark broadening of these lines in the electric fields of different nature. The plasma density is found to vary from 4 × 10{sup 14} to 2 × 10{sup 17} cm{sup −3}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-Shot Diagnosis of Electron Energy Evolution via Streaked Betatron X Rays in a Curved Laser Wakefield Accelerator

We report on an experimental observation of the streaking of betatron x rays in a curved laser wakefield accelerator. The streaking of the betatron x rays was realized by launching a laser pulse into a plasma with a transverse density gradient. By controlling the plasma density and the density gradient, we realized the steering of the laser driver, electron beam, and betatron x rays simultaneously. Furthermore, we observed an energy-angle correlation of the streaked betatron x rays and utilized it in diagnosing the electron acceleration process in a single-shot mode. Our work could also find applications in advanced control of laser beam and particle propagation. More importantly, the angular streaked betatron x ray has an intrinsic spatiotemporal correlation, which makes it a promising tool for single-shot pump-probe applications.

43 PARTICLE ACCELERATORS↗

Reducing streak film data via electronic cross correlator

Continuous /nonframing/ motion picture projector, two photocells, a cross-correlator, and a ground glass screen where the photocells intercept the stream image determine the time delay between successive streak images. Velocities corresponding to the streaks are determined from the delay together with the distance separating the photocells.

Dickerson, R. A.↗

Simultaneous streak and frame interferometry for electron density measurements of laser produced plasmas

A system of two collinear probe beams with different wavelengths and pulse durations was used to capture simultaneously snapshot interferograms and streaked interferograms of laser produced plasmas. The snapshots measured the two dimensional, path-integrated, electron density on a charge-coupled device while the radial temporal evolution of a one dimensional plasma slice was recorded by a streak camera. This dual-probe combination allowed us to select plasmas that were uniform and axisymmetric along the laser direction suitable for retrieving the continuous evolution of the radial electron density of homogeneous plasmas. Demonstration of this double probe system was done by measuring rapidly evolving plasmas on time scales less than 1 ns produced by the interaction of femtosecond, high intensity, laser pulses with argon gas clusters. Experiments aimed at studying homogeneous plasmas from high intensity laser-gas or laser-cluster interaction could benefit from the use of this probing scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of the quadrupole wakefields in a passive streaker

A novel method based on transverse wakefields has been recently proposed to characterize the temporal profile of a relativistic electron bunch. The electron bunch is streaked by the interaction with the transverse wakefield excited when the electrons travel off-axis in a device called the passive streaker. Furthermore, for the large transverse off-axis offsets required to effectively streak the electron bunch, higher order modes can be excited. The time-dependent quadrupole wakefield of the dielectric-lined structure can cause a significant enlargement of the transverse profile at the screen. Consequently, the measurement resolution is decreased also at the bunch tail. We report on how the temporal profile can be effectively reconstructed also including the defocusing effect for a given transverse beam distribution at the passive streaker.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Picosecond X-ray streak camera dynamic range measurement

Streak cameras are widely used to record the spatio-temporal evolution of laser-induced plasma. A prototype of picosecond X-ray streak camera has been developed and tested by Commissariat à l’Énergie Atomique et aux Énergies Alternatives to answer the Laser MegaJoule specific needs. The dynamic range of this instrument is measured with picosecond X-ray pulses generated by the interaction of a laser beam and a copper target. The required value of 100 is reached only in the configurations combining the slowest sweeping speed and optimization of the streak tube electron throughput by an appropriate choice of high voltages applied to its electrodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implosion dynamics of condensed Z-pinch at the Angara-5-1 facility

The implosion dynamics of a condensed Z-pinch at load currents of up to 3.5 MA and a current rise time of 100 ns was studied experimentally at the Angara-5-1 facility. To increase the energy density, 1- to 3-mm-diameter cylinders made of a deuterated polyethylene−agar-agar mixture or microporous deuterated polyethylene with a mass density of 0.03–0.5 g/cm{sup 3} were installed in the central region of the loads. The plasma spatiotemporal characteristics were studied using the diagnostic complex of the Angara-5-1 facility, including electron-optical streak and frame imaging, time-integrated X-ray imaging, soft X-ray (SXR) measurements, and vacuum UV spectroscopy. Most information on the plasma dynamics was obtained using a ten-frame X-ray camera (Е > 100 eV) with an exposure of 4 ns. SXR pulses were recorded using photoemissive vacuum X-ray detectors. The energy characteristics of neutron emission were measured using the time-offlight method with the help of scintillation detectors arranged along and across the pinch axis. The neutron yield was measured by activation detectors. The experimental results indicate that the plasma dynamics depends weakly on the load density. As a rule, two stages of plasma implosion were observed. The formation of hot plasma spots in the initial stage of plasma expansion from the pinch axis was accompanied by short pulses of SXR and neutron emission. The neutron yield reached (0.4–3) × 10{sup 10} neutrons/shot and was almost independent of the load density due to specific features of Z-pinch dynamics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System and method for x-ray compatible 2D streak camera for a snapshot multiframe imager

The present disclosure is directed to a snapshot multiframe imager having an aperture element having at least one aperture, an adjacently positioned random mask, an imaging element and a computer. The random mask has a plurality of micron scale apertures and receives light passing through the aperture element, which represents the spatial information from the scene being imaged, and generates a plurality of image frames encoded in a spatial domain. The imaging element may operate in a drift-scan mode receives the encoded image frames and generates a streaked pattern of electrons representing a plurality of images of the scene at a plurality of different times. The computer analyzes the streaked pattern of electrons and mathematically reconstructs the plurality of images.

Dayton, Matthew S.↗

Comparison of dislocation content measured with transmission electron microscopy and micro-Laue diffraction based streak analysis

The subsurface dislocation content in a Ti-5Al-2.5Sn (wt%) uniaxial tension sample deformed at ambient temperature was characterized by peak streak analysis of micro-Laue diffraction patterns collected non-destructively by differential aperture X-raymicroscopy, and with focused ion beam transmission electron microscopy of material in the same volume. This comparison reveals that micro-Laue diffraction streak analysis based on an edge dislocation assumption can accurately identify the dominant dislocation slip system history (Burgers vector and plane observed by TEM), despite the fact that dislocations have predominantly screw character. As a result, other dislocations identified by TEM were not convincingly discernible from the peak streak analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗