Electron Tomography and Machine Learning for Understanding the Highly Ordered Structure of Leafhopper Brochosomes

Insects known as leafhoppers (Hemiptera: Cicadellidae) produce hierarchically structured nanoparticles known as brochosomes that are exuded and applied to the insect cuticle, thereby providing camouflage and anti-wetting properties to aid insect survival. Although the physical properties of brochosomes are thought to depend on the leafhopper species, the structure–function relationships governing brochosome behavior are not fully understood. Brochosomes have complex hierarchical structures and morphological heterogeneity across species, due to which a multimodal characterization approach is required to effectively elucidate their nanoscale structure and properties. In this work, we study the structural and mechanical properties of brochosomes using a combination of atomic force microscopy (AFM), electron microscopy (EM), electron tomography, and machine learning (ML)-based quantification of large and complex scanning electron microscopy (SEM) image data sets. This suite of techniques allows for the characterization of internal and external brochosome structures, and ML-based image analysis methods of large data sets reveal correlations in the structure across several leafhopper species. Our results show that brochosomes are relatively rigid hollow spheres with characteristic dimensions and morphologies that depend on leafhopper species. Nanomechanical mapping AFM is used to determine a characteristic compression modulus for brochosomes on the order of 1–3 GPa, which is consistent with crystalline proteins. Altogether, this work provides an improved understanding of the structural and mechanical properties of leafhopper brochosomes using a new set of ML-based image classification tools that can be broadly applied to nanostructured biological materials.

Chemical structure↗

CryoTRANS: predicting high-resolution maps of rare conformations from self-supervised trajectories in cryo-EM

Cryogenic electron microscopy (cryo-EM) has revolutionized structural biology, enabling efficient determination of structures at near-atomic resolutions. However, a common challenge arises from the severe imbalance among various conformations of vitrified particles, leading to low-resolution reconstructions in rare conformations due to a lack of particle images in these quasi-stable states. We introduce CryoTRANS, a method that predicts high-resolution maps of rare conformations by constructing a self-supervised pseudo-trajectory between density maps of varying resolutions. This trajectory is represented by an ordinary differential equation parameterized by a deep neural network, ensuring retention of detailed structures from high-resolution density maps. By leveraging a single high-resolution density map, CryoTRANS significantly improves the reconstruction of rare conformations and has been validated on four real-world datasets: alpha-2-macroglobulin, actin-binding protein complexes, SARS-CoV-2 spike glycoprotein, and the 70S ribosome. CryoTRANS can also predict high-resolution structures in cryogenic electron tomography maps using a high-resolution cryo-EM map.Cryogenic electron microscopy (cryo-EM) has revolutionized structural biology, enabling efficient determination of structures at near-atomic resolutions. However, a common challenge arises from the severe imbalance among various conformations of vitrified particles, leading to low-resolution reconstructions in rare conformations due to a lack of particle images in these quasi-stable states. We introduce CryoTRANS, a method that predicts high-resolution maps of rare conformations by constructing a self-supervised pseudo-trajectory between density maps of varying resolutions. This trajectory is represented by an ordinary differential equation parameterized by a deep neural network, ensuring retention of detailed structures from high-resolution density maps. By leveraging a single high-resolution density map, CryoTRANS significantly improves the reconstruction of rare conformations and has been validated on four real-world datasets: alpha-2-macroglobulin, actin-binding protein complexes, SARS-CoV-2 spike glycoprotein, and the 70S ribosome. CryoTRANS can also predict high-resolution structures in cryogenic electron tomography maps using a high-resolution cryo-EM map.

47 OTHER INSTRUMENTATION↗

Accelerating Quantum Materials Development with Advances in Transmission Electron Microscopy

Quantum materials are driving a technology revolution in sensing, communication, and computing, while simultaneously testing many core theories of the past century. Materials such as topological insulators, complex oxides, superconductors, quantum dots, color center-hosting semiconductors, and other types of strongly correlated materials can exhibit exotic properties such as edge conductivity, multiferroicity, magnetoresistance, superconductivity, single photon emission, and optical-spin locking. These emergent properties arise and depend strongly on the material’s detailed atomic-scale structure, including atomic defects, dopants, and lattice stacking. In this review, we describe how progress in the field of electron microscopy (EM), including in situ and in operando EM, can accelerate advances in quantum materials and quantum excitations. We begin by describing fundamental EM principles and operation modes. We then discuss various EM methods such as (i) EM spectroscopies, including electron energy loss spectroscopy (EELS), cathodoluminescence (CL), and electron energy gain spectroscopy (EEGS); (ii) four-dimensional scanning transmission electron microscopy (4D-STEM); (iii) dynamic and ultrafast EM (UEM); (iv) complementary ultrafast spectroscopies (UED, XFEL); and (v) atomic electron tomography (AET). We describe how these methods could inform structure–function relations in quantum materials down to the picometer scale and femtosecond time resolution, and how they enable precision positioning of atomic defects and high-resolution manipulation of quantum materials. For each method, we also describe existing limitations to solve open quantum mechanical questions, and how they might be addressed to accelerate progress. Among numerous notable results, our review highlights how EM is enabling identification of the 3D structure of quantum defects; measuring reversible and metastable dynamics of quantum excitations; mapping exciton states and single photon emission; measuring nanoscale thermal transport and coupled excitation dynamics; and measuring the internal electric field and charge density distribution of quantum heterointerfaces- all at the quantum materials’ intrinsic atomic and near atomic-length scale. Finally, we conclude by describing open challenges for the future, including achieving stable sample holders for ultralow temperature (below 10K) atomic-scale spatial resolution, stable spectrometers that enable meV energy resolution, and high-resolution, dynamic mapping of magnetic and spin fields. With atomic manipulation and ultrafast characterization enabled by EM, quantum materials will be poised to integrate into many of the sustainable and energy-efficient technologies needed for the 21st century.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards Construction of a Novel Nanometer-Resolution MeV-STEM for Imaging Thick Frozen Biological Samples

Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300–500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 μm or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 μm to 10 μm. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is ~1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10 -4 energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10 -4 energy spread, and 0.1–1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 μm at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.

36 MATERIALS SCIENCE↗

Focused Interest Groups Propel Innovation in the Emerging Data-Driven Hardware Ecosystem

Over the past several decades, the science of electron microscopy (EM) has risen to become one of the cornerstone approaches to understanding material structure, chemistry, and defects at exceptional spatial resolution. This rise can be attributed to the hard work of researchers and companies who have pushed the bounds of instrumentation and analysis, but it is also the result of advocacy by members of professional societies. Furthermore, such advocacy is exemplified by the Aberration Corrected EM (ACEM) focused interest group (FIG) of the Microscopy Society of America (MSA), which has played an important role in facilitating new hardware developments, promoting the exchange of ideas to catalyze discovery, and building the next generation of leaders in electron microscopy. From the early 2000s to the present, aberration correction has moved from proof-of-concept instrumentation to an established technique, providing unprecedented improvements in spatial and chemical resolution for breakthroughs in chemistry, physics, and materials science.

47 OTHER INSTRUMENTATION↗

Electron Microscopy Studies of Soft Nanomaterials

This review highlights recent efforts on applying electron microscopy (EM) to soft (including biological) nanomaterials. We will show how developments of both the hardware and software of EM have enabled new insights into the formation, assembly, and functioning (e.g., energy conversion and storage, phonon/photon modulation) of these materials by providing shape, size, phase, structural, and chemical information at the nanometer or higher spatial resolution. Specifically, we first discuss standard real-space two-dimensional imaging and analytical techniques which are offered conveniently by microscopes without special holders or advanced beam technology. The discussion is then extended to recent advancements, including visualizing three-dimensional morphology of soft nanomaterials using electron tomography and its variations, identifying local structure and strain by electron diffraction, and recording motions and transformation by in situ EM. On these advancements, we cover state-of-the-art technologies designed for overcoming the technical barriers for EM to characterize soft materials as well as representative application examples. Here, the even more recent integration of machine learning and its impacts on EM are also discussed in detail. With our perspectives of future opportunities offered at the end, we expect this review to inspire and stimulate more efforts in developing and utilizing EM-based characterization methods for soft nanomaterials at the atomic to nanometer length scales in academic research and industrial applications.

Imaging↗

NanoPSD: A software for automatic detection of Nano-Particle Shape Distribution in electron microscopy images

Accurate quantification of the size and morphology of nanoparticles from electron microscopy (EM) images is essential to understand growth mechanisms, surface reactivity, and functional behavior in nanoscale materials. Manual analysis remains slow, subjective, and difficult to reproduce in large datasets. We introduce NanoPSD (Nano-Particle Shape Distribution), an open-source and fully automated framework for quantitative particle detection and morphology analysis from EM images. NanoPSD integrates adaptive contrast enhancement, polarity-agnostic scale-bar detection, Optical Character Recognition (OCR)-based calibration, and classical segmentation via Otsu thresholding with morphological refinement. Particle contours are used to extract geometric descriptors, including equivalent circular diameter, aspect ratio, circularity, and solidity, enabling automated classification into spherical, rod-like, and aggregate morphologies. The framework supports both single-image and batch processing, generating publication-quality visualizations, LaTeX-ready tables, and structured comma-separated values (CSV) datasets. As a demonstration, we applied NanoPSD to plasma-synthesized nanoparticle samples diagnosed via transmission electron microscopy (TEM). The code produced statistically robust size and morphology distributions spanning a few to tens of nanometers with minimal user supervision. The pipeline demonstrates high reproducibility and scalability, processing large image collections with consistent calibration and output formatting. Its modular design enables seamless integration of future deep-learning-based segmentation models, providing a pathway toward intelligent, data-driven electron microscopy analysis.

36 MATERIALS SCIENCE↗

Five myofibrillar lesion types in eccentrically challenged, unloaded rat adductor longus muscle--a test model

Sarcomere disruptions are observed in the adductor longus (AL) muscles following voluntary reloading of spaceflown and hindlimb suspension unloaded (HSU) rat, which resemble lesions in eccentrically challenged muscle. We devised and tested an eccentric contraction (ECCON) test system for the 14-day HSU rat AL. Six to 7 hours following ECCON, ALs were fixed to allow immunostaining and electron microscopy (EM). Toluidine blue-stained histology semithin sections were screened for lesion density (#/mm2). Serial semithin sections from the ECCON group were characterized for myosin immunointensity of lesions. Five myofibrillar lesion types were identified in histological semithin sections: focal contractions; wide A-bands; opaque areas; missing A-bands; and hyperstretched sarcomeres. Lesion density by type was greater for ECCON than NonECCON ALs (P< or =0.05; focal contractions and opaque regions). Lesion density (#-of-all-five-types/mm2) was significantly different (ECCON: 23.91+/-10.58 vs. NonECCON: 5.48+/-1.28, P< or =0.05; ECCON vs. SHAM: 0.00+/-0.00; P< or = 0.025). PostECCON optimal tension decreased (Poi-drop, 17.84+/-4.22%) and was correlated to lesion density (R2=0.596), but prestretch tension demonstrated the highest correlation with lesion density (R2=0.994). In lesions, the darkly staining A-band lost the normally organized thick filament alignment to differing degrees across the different lesion types. Ranking the five lesion types by a measure of lesion length deformation (hypercontracted to hyperstretched) at the light microscopy level, related to the severity of thick filament registry loss across the lesion types at the electron microscopic level. This ranking suggested that the five lesion types seen in semithin sections at the light level represented a lesion progression sequence and paralleled myosin immunostaining loss as the distorted A-band filaments spread across the hyperlengthening lesion types. Lesion ultrastructure indicated damage involved calcium homeostasis loss (focal contraction lesions) and "thick-filament-centering" failure of titin (wide A-band lesions) in the early stages of lesion development.

NASA Discipline Musculoskeletal↗

Targeting Mycobacterium tuberculosis Persistence through Inhibition of the Trehalose Catalytic Shift

Tuberculosis (TB), caused by Mycobacterium tuberculosis (Mtb), is the leading cause of death worldwide by infectious disease. Treatment of Mtb infection requires a six-month course of multiple antibiotics, an extremely challenging regimen necessitated by Mtb’s ability to form drug-tolerant persister cells. Mtb persister formation is dependent on the trehalose catalytic shift, a stress-responsive metabolic remodeling mechanism in which the disaccharide trehalose is liberated from cell surface glycolipids and repurposed as an internal carbon source to meet energy and redox demands. Here, using a biofilm-persister model, metabolomics, and cryo-electron microscopy (EM), we found that azidodeoxy- and aminodeoxy-d-trehalose analogues block the Mtb trehalose catalytic shift through inhibition of trehalose synthase TreS (Rv0126), which catalyzes the isomerization of trehalose to maltose. Out of a focused eight-member compound panel constructed by chemoenzymatic synthesis, the natural product 2-trehalosamine exhibited the highest potency and significantly potentiated first- and second-line TB drugs in broth culture and macrophage infection assays. We also report the first structure of TreS bound to a substrate analogue inhibitor, obtained via cryo-EM, which revealed conformational changes likely essential for catalysis and inhibitor binding that can potentially be exploited for future therapeutic development. Our results demonstrate that inhibition of the trehalose catalytic shift is a viable strategy to target Mtb persisters and advance trehalose analogues as tools and potential adjunctive therapeutics for investigating and targeting mycobacterial persistence.

60 APPLIED LIFE SCIENCES↗

Visualizing Millisecond Atomic Dynamics of Nanocrystals in Liquid

Atomic structures of nanomaterials are inherently dynamic and continuously reshaped through interactions with chemical species and external stimuli. Such dynamics are further amplified as the size and dimensionality of nanomaterials decrease. Despite advances in analytical methods, it remains challenging to capture the structural dynamics of nanomaterials in reactive environments with both atomic spatial resolution and commensurate temporal resolution. Here, in this study, we directly visualize atomic-scale dynamics of gold (Au) nanocrystals in reactive liquid environments with millisecond-speed liquid-cell electron microscopy (EM) and deep-learning denoising. We uncover reversible fluctuations in the local crystallinity of Au nanocrystals dependent on the surrounding chemical environment. These transient fluctuations, driven by interactions at nanocrystal–liquid interfaces, critically influence the dissolution kinetics and grain boundary relaxation. By overcoming the spatiotemporal limitations in conventional liquid-cell EM, our findings provide insights into how transient nanoscale structures dictate the stability and reactivity of nanomaterials.

Kang, Sungsu [University of Chicago, IL (United St↗

Exploring cryo-electron microscopy with molecular dynamics

Single particle analysis cryo-electron microscopy (EM) and molecular dynamics (MD) have been complimentary methods since cryo-EM was first applied to the field of structural biology. The relationship started by biasing structural models to fit low-resolution cryo-EM maps of large macromolecular complexes not amenable to crystallization. The connection between cryo-EM and MD evolved as cryo-EM maps improved in resolution, allowing advanced sampling algorithms to simultaneously refine backbone and sidechains. Moving beyond a single static snapshot, modern inferencing approaches integrate cryo-EM and MD to generate structural ensembles from cryo-EM map data or directly from the particle images themselves. We summarize the recent history of MD innovations in the area of cryo-EM modeling. The merits for the myriad of MD based cryo-EM modeling methods are discussed, as well as, the discoveries that were made possible by the integration of molecular modeling with cryo-EM. Lastly, current challenges and potential opportunities are reviewed.

Biochemistry & Molecular Biology↗

Architecture and functional regulation of a plant PSII-LHCII megacomplex

Photosystem II (PSII) splits water in oxygenic photosynthesis on Earth. The structure and function of the C 4 S 4 M 2 -type PSII-LHCII (light-harvesting complex II) megacomplexes from the wild-type and PsbR-deletion mutant plants are studied through electron microscopy (EM), structural mass spectrometry, and ultrafast fluorescence spectroscopy [time-resolved fluorescence (TRF)]. The cryo-EM structure of a type I C 4 S 4 M 2 megacomplex demonstrates that the three domains of PsbR bind to the stromal side of D1, D2, and CP43; associate with the single transmembrane helix of the redox active Cyt b 559 ; and stabilize the luminal extrinsic PsbP, respectively. This megacomplex, with PsbR and PsbY centered around the narrow interface between two dimeric PSII cores, provides the supramolecular structural basis that regulates the plastoquinone occupancy in Q B site, excitation energy transfer, and oxygen evolution. PSII-LHCII megacomplexes (types I and II) and LHC aggregation levels in Arabidopsis psbR mutant were also interrogated and compared to wild-type plants through EM and picosecond TRF.

Science & Technology - Other Topics↗

Structural analysis of platelet fragments and extracellular vesicles produced by apheresis platelets during storage

Platelets (PLTs) for transfusion can be stored for up to 7 days at room temperature (RT). The quality of apheresis PLTs decreases over storage time, which affects PLT hemostatic functions. Here, we characterized the membranous particles produced by PLT storage lesion (PSLPs), including degranulated PLTs, PLT ghosts, membrane fragments, and extracellular membrane vesicles (PEVs). The PSLPs generated in apheresis platelet units were analyzed on days 1, 3, 5, and 7 of RT storage. A differential centrifugation and a sucrose density gradient were used to separate PSLP populations. PSLPs were characterized using scanning and transmission electron microscopy (EM), flow cytometry (FC), and nanoparticle tracking analysis (NTA). PSLPs have different morphologies and a broad size distribution; FC and NTA showed that the concentration of small and large PSLPs increases with storage time. The density gradient separated 3 PSLP populations: (1) degranulated PLTs, PLT ghosts, and large PLT fragments; (2) PEVs originated from PLT activation and organelles released by necrotic PLTs; and (3) PEV ghosts. Most PSLPs expressed phosphatidyl serine and induced thrombin generation in the plasma. PSLPs contained extracellular mitochondria and some had the autophagosome marker LC3. PSLPs encompass degranulated PLTs, PLT ghosts, large PLT fragments, large and dense PEVs, and low-density PEV ghosts. The activation-related PSLPs are released, particularly during early stage of storage (days 1-3), and the release of apoptosis- and necrosis-related PSLPs prevails after that. No elevation of LC3- and TOM20-positive PSLPs indicates that the increase of extracellular mitochondria during later-stage storage is not associated with PLT mitophagy.

59 BASIC BIOLOGICAL SCIENCES↗

High-temperature and high-pressure NMR investigations of low viscous fluids confined in mesoporous systems

Abstract In this contribution, the relaxation and diffusional behaviors of low viscous fluids, water and methanol confined into mesoporous silica and controlled size pore glass were investigated. The engineered porous systems are relevant to geologically important subsurface energy materials. The engineered porous proxies were characterized by Brunauer–Emmett–Teller (BET) surface analyzer, nuclear magnetic resonance (NMR) spectroscopy, and electron microscopy (EM) to determine surface area, pore-wall protonation and morphology of these materials, respectively. The confined behavior of the low viscous fluids was studied by varying pore diameter, fluid-to-solid ratio, temperature, and pressure, and then compared to bulk liquid state. Both relaxation and diffusion behaviors for the confined fluids showed increasing deviation from pure bulk fluids as the fluid-to-solid ratio was decreased, and surface-to-volume ratio ( S / V ) was varied. Variable pressure deuteron NMR relaxation of confined D 2 O and confined methanol, deuterated at the hydroxyl or methyl positions, were performed to exploit the sensitivity of the deuteron quadrupole moment to molecular rotation. The methanol results demonstrated greater pressure dependence than those for water only in bulk. The deviations from bulk liquid behavior arise from different reasons such as confinement and the interactions between confined fluid and the nano-pore wall. The results of the present report give insight into the behavior of low viscosity fluid in nano-confined geometries under different state conditions.

Chemistry↗

Open Reproducible Electron Microscopy Data Analysis

Electron microscopy (EM) is a cornerstone technique in the materials and biological sciences capable of imaging structures at nano- to atomic-scale resolution. Advances in technologies mean that one acquires datasets at increasing data rates and sizes. These advancements present enormous opportunities for researchers to understand complex systems. However, processing the resulting large-scale, complex data in a reproducible and shareable way is a real challenge for researchers. The building, managing, and maintaining complex workflows in a reproducible manner requires extensive knowledge in several areas outside the researchers’ core skill sets, such as software engineering, data science, and high-performance computing (HPC). Our work demonstrates an innovative approach to solving these problems, enabling reproducible EM data analysis through container encapsulated pipelines. Using modern container technologies, we encapsulate processing elements and connect them using shared memory. We expose user-friendly, advanced algorithms and tools to allow end users to utilize without expert programming skills. The platform enables reproducible, scalable, shareable pipelines for the analysis and visualization of EM data. Focusing on interoperability, we leverage the DOE and other agencies’ existing investments to provide a powerful software platform for EM data analysis.

Harris, Christopher↗

Machine Learning Based Software Package for Reproducible Data Analysis for Electron Microscopy

Advances in hardware and computation technologies are enabling large hyperspectral imaging during Electron Microscopy (EM), resulting in datasets being produced at rapidly increasing spatial and temporal resolutions. This presents exciting opportunities for microstructure analysis, but also poses great challenges in data analysis. Under this STTR program, QuesTek Innovations LLC, a leader in the field of integrated computational materials engineering (ICME), collaborated with Lawrence Livermore National Laboratory and Argonne National Laboratory. The team developed an open-source machine learning (ML) powered tool for EM data analysis of multiple systems and data types, and collected EM data for ML model development using the cutting-edge PicoProbe equipment at Argonne National Laboratory.

Lin, Yu↗

Developing High-Flux Ion Soft Landing with Mass-Selection for Improved Cryo-Electron Microscopy

The goal of this project is to redesign and repurpose existing high-flux ion soft-landing (SL) instrumentation developed at PNNL for new structural biology applications by integrating SL, mass-selection/separation of high mass-to-charge species, native mass spectrometry (MS), and cryo-electron microscopy (EM) to generate a workflow enabling structural and functional annotation of proteins and other complex biological samples. Ultimately, this work will result in a new instrument for mass-selection and SL based cryo-EM sample preparation and potentially increase the impact of PNNL and the broader microscopy community through commercial licensing.

47 OTHER INSTRUMENTATION↗

A Novel Approach to Solving the Problem of Needle Microcrystals (A Case Study of Ribosome Crystals)

Different morphology crystals (needle, rod-tetragonal and wedge-shaped) were grown from the same solution of ribosome; furthermore, in the same drop using 10- 15% 2-methyl-2,4pentanediol as a precipitant. The crystals appeared in 5-48 hours. Observations of the kinetics of crystals appearance lead to the conclusion that higher supersaturation of ribosome solution produces needle-shaped crystals, while the tetragonal-rod and the wedge-shaped crystals grow at lower supersaturation. The ribosome packing in the crystals was characterized by electron microscopy (EM). An analysis of EM ultrathin sections indicates that the unit cells, with a high degree of probability, are the same in the crystals of different morphology. The data obtained suggests how to shift the process of crystal formation from the needles to the crystals with comparative size in all three dimensions.