Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron microscope tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Preparing Lamellae from Vitreous Biological Samples using a Dual-Beam Scanning Electron Microscope for Cryo-Electron Tomography

Presented here is a protocol for preparing cryo-lamellae from plunge-frozen grids of Plasmodium falciparum-infected human erythrocytes, which could easily be adapted for other biological samples. The basic principles for preparing samples, milling, and viewing lamellae are common to all instruments and the protocol can be followed as a general guide to on-grid cryo-lamella preparation for cryo-electron microscopy (cryoEM) and cryo-electron tomography (cryoET). Electron microscopy grids supporting the cells are plunge-frozen into liquid nitrogen-cooled liquid ethane using a manual or automated plunge freezer, then screened on a light microscope equipped with a cryo-stage. Frozen grids are transferred into a cryo-scanning electron microscope equipped with a focused ion beam (cryoFIB-SEM). Grids are routinely sputter coated prior to milling, which aids dispersal of charge build-up during milling. Alternatively, an e-beam rotary coater can be used to apply a layer of carbon-platinum to the grids, the exact thickness of which can be more precisely controlled. Once inside the cryoFIB-SEM an additional coating of an organoplatinum compound is applied to the surface of the grid via a gas injection system (GIS). This layer protects the front edge of the lamella as it is milled, the integrity of which is critical for achieving uniformly thin lamellae. Regions of interest are identified via SEM and milling is carried out in a step-wise fashion, reducing the current of the ion beam as the lamella reaches electron transparency, in order to avoid excessive heat generation. A grid with multiple lamellae is then transferred to a transmission electron microscope (TEM) under cryogenic conditions for tilt-series acquisition. A robust and contamination-free workflow for lamella preparation is an essential step for downstream techniques, including cellular cryoEM, cryoET, and sub-tomogram averaging. Development of these techniques, especially for lift-out and milling of high-pressure frozen samples, is of high-priority in the field.

59 BASIC BIOLOGICAL SCIENCES↗

A Cristae-Like Microcompartment in Desulfobacterota

Some Alphaproteobacteria contain intracytoplasmic membranes (ICMs) and proteins homologous to those responsible for the mitochondrial cristae, an observation which has given rise to the hypothesis that the Alphaproteobacteria endosymbiont had already evolved cristae-like structures and functions. However, our knowledge of microbial fine structure is still limited, leaving open the possibility of structurally homologous ICMs outside the Alphaproteobacteria. Here, we report on the detailed characterization of lamellar cristae-like ICMs in environmental sulfate-reducing Desulfobacterota that form syntrophic partnerships with anaerobic methane-oxidizing (ANME) archaea. These structures are junction-bound to the cytoplasmic membrane and resemble the form seen in the lamellar cristae of opisthokont mitochondria. Extending these observations, we also characterized similar structures in Desulfovibrio carbinolicus, a close relative of the magnetotactic D. magneticus, which does not contain magnetosomes. Despite a remarkable structural similarity, the key proteins involved in cristae formation have not yet been identified in Desulfobacterota, suggesting that an analogous, but not a homologous, protein organization system developed during the evolution of some members of Desulfobacterota.

electron microscope tomography↗

Advanced Characterization of Fuel-cladding Chemical Interaction between U-10Zr Fuel and HT9 Cladding Tested in Fast Flux Test Facility

Fuel cladding chemical interaction (FCCI) can greatly accelerate the cladding failure. However, due to the limited space in a fuel cladding assembly, it is historically challenging to gain an mechanistical understanding of the formation mechanism of FCCI and its influence on fuel and cladding performance. With the imminent need to qualify U-10Zr based metallic fuel cladded by HT-9 for advanced reactors demonstration project, it is of vital importance to use advanced characterization method to study FCCI in a unprecedent detailed manner and gain better mechanism understanding of FCCI. Mechanistic Fuel Failure (MFF) series of prototypic fuel elements irradiated in FFTF [1, 2] provides the best samples to study FCCI since the MFF-series assemblies had an axial fuel height the same as proposed length by industry partners. Jason et al. [3] has performed preliminary post-irradiation examination on a MFF fuel pin sample, which was extracted from the HT9 cladded U-10at.%Zr MFF-3 pin MFF-3 pin (#193045) at an axial location of X/L = 0.98. This sample has a peak burnup of 5.7 at.% and peak inner cladding temperature (PICT) of around 615 °C during in-core testing. Scanning electron microscope examination has identified visible FCCI region on more than half of the HT9 circumference [3]. The most striking feature are grain boundary attacking by apparently lanthanides (Lns) rich phase. However, SEM cannot provide accurate assessment of phase and concentration of grain boundary phases and prevented a better understanding of the formation mechanism of such attach. This study, by pairing transmission electron microscope (TEM) characterization and atom probe tomography (APT) techniques with in-situ micro-tensile testing in scanning electron microscope (SEM), aims at gaining in-depth understanding on the formed FCCI region. The identified FCCI region roughly consists of multilayers as illustrated in Figure 1 (c). The main findings are: (1) layer-B shows observable lanthanides (Lns) infiltration along grain boundaries and mechanical softening due to FCCI- and irradiation-induced microstructural and microchemistry changes, particularly the recovery of martensitic lath structure and dissolution of pre-existing M23C6 together with the formation of coarsened Laves phases, (Fe, Cr)2(Mo, W); (2) layer-C is Fe depleted but Lns significantly enriched, becoming very brittle; (3) layer-D is mainly composed of UFe2 and Lns; (4) three FCCI-induced intermetallic U-Fe-Zr phases, ? (Fe0.5Zr0.32U0.18), e (Fe0.3Zr0.4U0.3), ? (Fe0.06Zr0.23U0.71), were identified near layer-E; (5) the ? (Fe0.5Zr0.32U0.18) phase was characterized to be a face centered cubic (FCC) crystal structure. These results will help to better understanding the governing mechanism of FCCI and facilitating the development of theoretical model for assessing the performance of metallic fuel and cladding integrity.

36 MATERIALS SCIENCE↗

Angle between DNA linker and nucleosome core particle regulates array compaction revealed by individual-particle cryo-electron tomography

Abstract The conformational dynamics of nucleosome arrays generate a diverse spectrum of microscopic states, posing challenges to their structural determination. Leveraging cryogenic electron tomography (cryo-ET), we determine the three-dimensional (3D) structures of individual mononucleosomes and arrays comprising di-, tri-, and tetranucleosomes. By slowing the rate of condensation through a reduction in ionic strength, we probe the intra-array structural transitions that precede inter-array interactions and liquid droplet formation. Under these conditions, the arrays exhibite irregular zig-zag conformations with loose packing. Increasing the ionic strength promoted intra-array compaction, yet we do not observe the previously reported regular 30-nanometer fibers. Interestingly, the presence of H1 do not induce array compaction; instead, one-third of the arrays display nucleosomes invaded by foreign DNA, suggesting an alternative role for H1 in chromatin network construction. We also find that the crucial parameter determining the structure adopted by chromatin arrays is the angle between the entry and exit of the DNA and the corresponding tangents to the nucleosomal disc. Our results provide insights into the initial stages of intra-array compaction, a critical precursor to condensation in the regulation of chromatin organization.

59 BASIC BIOLOGICAL SCIENCES↗

High‐Resolution Electron Tomography of Ultrathin Boerdijk–Coxeter–Bernal Nanowire Enabled by Superthin Metal Surface Coating

Abstract The rapid advancement of transmission electron microscopy has resulted in revolutions in a variety of fields, including physics, chemistry, and materials science. With single‐atom resolution, 3D information of each atom in nanoparticles is revealed, while 4D electron tomography is shown to capture the atomic structural kinetics in metal nanoparticles after phase transformation. Quantitative measurements of physical and chemical properties such as chemical coordination, defects, dislocation, and local strain have been made. However, due to the incompatibility of high dose rate with other ultrathin morphologies, such as nanowires, atomic electron tomography has been primarily limited to quasi‐spherical nanoparticles. Herein, the 3D atomic structure of a complex core–shell nanowire composed of an ultrathin Boerdijk–Coxeter–Bernal (BCB) core nanowire and a noble metal thin layer shell deposited on the BCB nanowire surface is discovered. Furthermore, it is demonstrated that a new superthin noble metal layer deposition on an ultrathin BCB nanowire could mitigate electron beam damage using an in situ transmission electron microscope and atomic resolution electron tomography. The colloidal coating method developed for electron tomography can be broadly applied to protect the ultrathin nanomaterials from electron beam damage, benefiting both the advanced material characterizations and enabling fundamental in situ mechanistic studies.

Song, Xiaohui↗

Web-based Preprocessing and Visualization of 3D FIB Tomography Data for Nuclear Fuel Characterization

Three-dimensional (3D) focused ion beam (FIB) tomography enables reconstruction of internal nuclear fuel features that can't be fully evaluated through surface imaging alone. This capability supports characterization of fuel constituents and defects under thermal and irradiation conditions relevant to microreactor development. However, large tomography datasets can create data-handling, loading, and visualization challenges, especially when image-stack preparation and file conversion must be completed with separate tools. The Computational Ultraspatial Tomography Toolkit for High-Resolution Object Analysis Tools (CUTTRHOAT) is an open-source web application being developed to display FIB tomography datasets available through the Nuclear Research Data System (NRDS). The current alpha version requires prepared HDF5 datasets and has limited integrated data-preparation capabilities. This project improves CUTTHROAT by adding dataset-folder selection, automatic input detection, dataset scanning, missing-slice identification, blank-slice insertion, and image-stack-to-HDF5 conversion. Two applications will be compared: the baseline CUTTHROAT alpha workflow and the updated application containing the integrated data-handling and preprocessing functions. Evaluation will consider dataset detection accuracy, conversion success, loading time, rendering responsiveness, application stability, and user interaction. Preliminary results demonstrate successful loading of existing HDF5 files and converted image stacks, while testing also identified performance reductions caused by excessive blank-slice generation. The updated workflow reduces reliance on external preparation tools and supports more direct movement from image stacks to color-code 3D visualization. Future work includes refining missing-slice handling, integrating additional preprocessing functions, like a denoising feature, parsing TIFF metadata for automatic voxel scaling, and adding manual X, Y, and Z voxel-spacing inputs for PNG and JPEG.

36 - MATERIALS SCIENCE↗

Water-Oil Displacement in Shale: New Insights from a Comparative Study Integrating Imbibition Tests and Multiscale Imaging

Water-oil displacement is an important process that occurs in a shale matrix after hydraulic fracturing and in water-based enhanced oil recovery. Current understanding of this displacement process is limited because of the complicated pore structure and surface properties in shale. In this work, this process and its controlling factors are investigated through a comparative study of three shale samples that have different types of pore systems and wettability. Here, an integrated method of imbibition and multiscale imaging was applied, and a modified oleic tracer that can better represent oil flow was used in imbibition testing and micro-computed tomography (CT) imaging. Scanning electron microscope (SEM) pore characterization was then performed under high magnification with guidance from the micro-CT images showing the changes caused by oil or water imbibition. New insights were obtained on the importance of both wettability and pore size effect on oil recovery and the distribution of residual oil after water-oil displacement. Connectivity of pores with different wettability is also discussed based on 3D analysis and SEM pore characterization. Collectively, these new findings improve the understanding of the complicated process of water-oil displacement and the role of influencing factors. Important implications for improved oil recovery strategy in shale are discussed for different types of reservoir rocks. The integrated imaging and imbibition technique provides a new path for further investigation of improved oil recovery in shale.

04 OIL SHALES AND TAR SANDS↗

Open Source Visualization and Analysis Platform for 3D Reconstructions of Materials by Transmission Electron Microscopy

Three-dimensional characterization of materials at the nano- and meso-scale has become possible with transmission and scanning transmission electron microscopes (S/TEM). Its importance has extended to a wide class of nanomaterials such as hydrogen fuel cells, solar cells, industrial catalysts, new battery materials and semiconductor devices, as well as spanning high-tech industry, universities, and national labs. While capable instrumentation is abundant, this rapidly expanding demand for high-resolution tomography is bottlenecked by software that is instead tailored for lower-dose, biological applications and not optimized for higher-resolution materials applications. Existing tomography fails to utilize the chemical information provided by S/TEM spectrometers. To address this problem, this project delivered a scalable, fully functional, freely-distributable, open Source materials tomography package with a modern user interface that enables automated acquisition, alignment, and real-time reconstruction of raw tomography data, and provides advanced segmentation, three-dimensional chemical visualization and analysis optimized for materials applications. It has established an extendable framework capable of automation for high-throughput for the tomography of materials from data acquisition to visualization. Phase I and II delivered a full-featured, cross-platform, clean and integrated application for S/TEM materials tomography. It can read projection data from the microscope, with graphical tools for alignment of data, tomographic reconstruction, segmentation, and visualization of the reconstructed 3D volume. The entire pipeline can be saved to an XML state file, enabling fully reproducible data processing and analysis with a full Python environment for the development of custom algorithms, processing, and analysis requirements. Phase IIB extended the application to provide real-time tomographic reconstruction, "live updates" as data is processed, analysis of big data, and multi-channel tomography. Here, quantitative assessment of nanomaterials can occur as data is being recorded on a 3D visualization platform that accommodates additional information from multiple channels. We provide unmatched high-throughput tomography, where the complete tomographic pipeline from measurement to 3D visualization can occur rapidly. The project was extended to offer capabilities for micro-CT, X-ray, neutron, focused ion beam, atomic electron tomography and atom probe tomography. With over 600 transmission electron microscopes worldwide and approximately 50 coming online each year, the demand and impact of an open-source tomography tool is large. Significant opportunities exist in high-tech industry, universities, and national labs to enable or enhance three-dimensional imaging at the nanoscale and bring automated high-throughput approaches that will accelerate progress in materials characterization and metrology. The project supports a service based business model by enabling lab-specific acquisition and processing customization and integration-support and development that will be provided into Phase III and beyond.

36 MATERIALS SCIENCE↗

Microscopic analysis of copper current collectors and mechanisms of fragmentation under compressive forces

Extensive fragmentation of copper current collectors was observed after spherical indentation on prismatic and large-format pouch Li-ion cells by 3D X-ray computed tomography (XCT). Microscopic analysis including scanning electron microscopy (SEM), scanning transmission electron microscopy (STEM) and x-ray photoelectron microscopy (XPS) was carried out on copper current collectors from used commercial cells and pristine anodes. The copper-graphite cross-section images showed rough interface areas affected by reactions and diffusion in the used cell. Electron probe micro-analyzer (EPMA) element mapping showed the interface area was rich in oxygen and phosphorus. A detectable amount of phosphorus was also uniformly distributed inside the current collector. The same oxygen and phosphorus distributions were confirmed by STEM/EDS analysis. XPS depth profiles on multiple elements revealed the interface area of the aged anode was rich in Li, F, P, O and C and diffused at least 50 nm into the copper. In comparison, the pristine anode showed a very smooth C/Cu interface. No other elements were detected. For commercial cells, the reactions in the interface area and diffusion of multiple elements into the lattice and grain boundaries were responsible for the embrittlement of the copper current collectors. Finally, permanent cell capacity loss was observed in electrochemical performance of the indented cells.

36 MATERIALS SCIENCE↗

Water Imbibition and Oil Recovery in Shale: Dynamics and Mechanisms Using Integrated Centimeter-to-Nanometer-Scale Imaging

Water imbibition, and the associated oil displacement, is an important process in shale oil reservoirs after hydraulic fracturing and in water-based enhanced oil recovery (EOR). Current techniques for water imbibition measurement are mostly “black-box”-type methods. A more explicit understanding of the water imbibition/oil recovery dynamics and geological controls is in demand. In this paper, a multiscale imaging technique that covers centimeter to nanometer scale (i.e., core to pore scale), integrating neutron radiography, microcomputed tomography (micro-CT), and scanning electron microscope (SEM) is applied to investigate the water imbibition depth and rate and the cause of heterogeneity of imbibition in shale samples. The dynamic processes of water imbibition in the 1-in. (25.4-mm) core sample were explicitly demonstrated, and the imbibition along the matrix and imbibition through microfractures are distinguished through neutron radiography image analysis. The causes of observed imbibition heterogeneity were further investigated through micro-CT and SEM image analysis for 1.5-mm diameter miniplug samples from different laminas of the 1-in. core samples. Imbibition depth and rate were calculated on the basis of image analysis as well. Estimation of oil recovery through water imbibition in shale matrix was performed for an example shale field. Here this innovative and integrated multiscale imaging technique provides a “white/gray-box” method to understand water imbibition and water-oil displacement in shale. The wide span of the length scale (from centimeter to nanometer) of this technique enables a more comprehensive, accurate, and specific understanding of both the core-scale dynamics and pore-scale mechanisms of water imbibition, oil recovery, and matrix-fracture interaction.

04 OIL SHALES AND TAR SANDS↗

Measuring Multicomponent Adsorption of Tracer Gases on Natural Zeolites

A natural clinoptilolite sample near the Nevada National Security Site was obtained to study adsorption and retardation on gas transport. Of interest is understanding the competition for adsorption sites that may reduce tracer gas adsorption relative to single-component measurements, which may be affected by the multi-scale pore structure of clinoptilolite. Clinoptilolite has three distinct domains of pore size distributions ranging from nanometers to micrometers: micropores with 0.4–0.7 nm diameters, measured on powders by CO2 adsorption at 273 K, representing the zeolite cages; mesopores with 4–200 nm diameters, observed using liquid nitrogen adsorption at 77 K; and macropores with 300–1000 nm diameters, measured by mercury injection on rock chips (~ 100 mesh), likely representing the microfractures. These pore size distributions are consistent with X-ray computed tomography (CT) and focused ion beam scanning electron microscope (FIB-SEM) images, which are used to construct the three-dimensional (3D) pore network to be used in future gas transport modeling. To quantify tracer gas adsorption in this multi-scale pore structure and multicomponent gas species environment, natural zeolite samples initially in equilibrium in air were exposed to a mixture of tracer gases. As the tracer gases diffuse and adsorb in the sample, the remaining tracer gases outside the sample fractionate. Using a quadrupole mass spectrometer to quantify this fractionation, the degree of adsorption of tracer gases in the multicomponent gas environment and multi-scale pore structure is assessed. The major finding is that Kr reaches equilibrium much faster than Xe in the presence of ambient air, which leads to more Kr uptake than Xe over limited exposure periods. When the clinoptilolite chips were exposed to humid air, the adsorption capability decreases significantly for both Xe and Kr with relative humidity (RH) as low as 3%. Both Xe and Kr reaches equilibrium faster at higher RH. The different, unexpected, adsorption behavior for Xe and Kr is due to their kinetic diameters similar to the micropores in clinoptilolite which makes it harder for Xe to access compared to Kr.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale Three-Dimensional Imaging of Integrated Circuits Using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO 2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.

47 OTHER INSTRUMENTATION↗

A Review of Advanced Characterization Methods and Techniques for Amorphous and Poorly Crystalline Materials Applicable to Cementitious Waste Forms

This review covers advanced characterization methods of cementitious materials. The particular focus is to understand cementitious compositions with amorphous content because conventional techniques such as X-ray diffraction are more applicable to materials with long range order. Also of interest is advanced characterization that provides deeper insights into properties such as porosity. There are five groups of characterization methods discussed in this review which are: electron beam/microscopy, X-ray, neutron diffraction and scattering, nuclear magnetic resonance, and optical techniques. The techniques can be further grouped by the categories of nanoscale structural understanding (transmission electron microscopy and pair distribution function), microscale structural understanding (focused ion beam and x-ray tomography), microscopic elemental distributions (energy dispersive spectroscopy and X-ray fluorescence), and chemical binding information (electron energy loss spectroscopy, x-ray absorption spectroscopy, nuclear magnetic resonance, Raman spectroscopy, and infrared spectroscopy), with advantages and disadvantages of each method discussed. The recommendation for further research is to begin with techniques that are easier to prepare samples for, measure, and analyze, such as the optical techniques of Raman and infrared spectroscopy. If more information is needed, pursue collaborations, other techniques, or proposals for beam time at the synchrotron sources.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rapid assessment of structural and compositional changes during early stages of zirconium alloy oxidation

A multimodal chemical imaging approach has been developed and applied to detail the dynamic, atomic-scale changes associated with oxidation of a zirconium alloy (Zircaloy-4). Scanning transmission electron microscopy, a gas-phase reactor chamber attached to an atom probe tomography instrument, and synchrotron-based X-ray absorption near-edge spectroscopy were employed to reveal morphology, composition, crystal, and electronic structure changes that occur during initial stages of oxidation at 300 °C. Oxidation was carried out in 10 mbar O 2 gas for short exposure times of 1 and 5 min. A multilayered oxide film with a cubic ZrO adjacent to the oxide/metal interface, a nanoscopic transition region with a graded composition of ZrO 2-x (where 0 < x < 1), and tetragonal ZrO 2 in the outermost oxide were formed. Partitioning of the major alloying element (tin) to the oxide/metal interface and heterogeneously within the oxide accompanied the development of the layered oxide. Our work provides a rapid, high-throughput approach for detailed characterisation of initial stages of zirconium alloy oxidation at an accelerated time scale, with implications for several other alloy systems.

36 MATERIALS SCIENCE↗

Energy-Dispersive X-ray Spectroscopy and Atom-probe Tomography Data Quantifying Component-Ratios of Multicomponent Nano-Precipitates in Ion-Irradiated Ceria

Samples of ~1 µm films of CeO2 doped with 2 wt% Mo, 1.5 wt% Ru, 0.75 wt% Pd, 0.5 wt% Re and 0.25 wt% Rh grown with pulsed laser deposition were irradiated with I2+ ions (610°C and 730°C, 1016 and 5×1016 I2+/cm2). For selected samples post-irradiation heat treatment was conducted (900°C, 1100°C). The specimens were sectioned with focussed ion beam milling and characterized in a transmission electron microscope with energy dispesive x-ray spectroscopy, and with atom-probe tomography. Energy dispersive x-ray spectroscopy was used to obtain elemental maps showing the distribution of dopants in the specimen after exposure. Some of these maps are discussed in detail in our companion article “Formation of multicomponent alloy particles in doped ceria under I2+ ion irradiation and thermal annealing” in the Journal of Nuclear Materials [REF]. Advanced computational analysis could be used to more accurately quantify local compositions. Data is provided for additional regions of interest and one additional irradiation condition. The doped Ceria film that was heat treated at 1100 °C delaminated from the substrate in most places. Samples were extracted from the underside of a delaminated piece and analyzed with atom-probe tomography. The resulting data show Ceria and a Mo-rich particle and demonstrate that this approach is feasable in principle to study local compositions in a sample exposed to such extreme conditions.

multicomponent alloys, epsilon phase, EDS, atom pr↗

Real-time 3D analysis during electron tomography using tomviz

The demand for high-throughput electron tomography is rapidly increasing in biological and material sciences. However, this 3D imaging technique is computationally bottlenecked by alignment and reconstruction which runs from hours to days. We demonstrate real-time tomography with dynamic 3D tomographic visualization to enable rapid interpretation of specimen structure immediately as data is collected on an electron microscope. Using geometrically complex chiral nanoparticles, we show volumetric interpretation can begin in less than 10 minutes and a high-quality tomogram is available within 30 minutes. Real-time tomography is integrated into tomviz, an open-source and cross-platform 3D data analysis tool that contains intuitive graphical user interfaces (GUI), to enable any scientist to characterize biological and material structure in 3D.

36 MATERIALS SCIENCE↗

Advanced Interactive 3D Visualization Tool for Customizable Analyses of Tomography Datasets in Material Science

Current methods for visualizing and analyzing 3D tomography datasets in materials science often lack the interactivity and depth required for detailed structural insights. This limitation restricts a researchers' ability to accurately interpret complex data, which is critical for advancing material innovations and understanding structural properties. To address this issue, we have developed a novel, web-based interactive 3D visualization and analysis tool from the Trame framework that offers customizable features to enhance data interpretability. The tool allows users to adjust parameters such as visible range, slice planes, data rotation, and layering, providing a more detailed and dynamic view of complex structures. Its user-friendly web interface increases the accessibility and ease of use for both novice and experienced researchers, to visualize large volumetric datasets. The tool supports a diverse range of data formats, making it versatile for various research applications. Unique capabilities include real-time data manipulation, automated feature detection, context-sensitive feedback, and real-time volume calculations and distributions per sliced region or layer, alongside the ability to quickly generate high-quality screenshots and videos for presentations and reports. These advancements offer a comprehensive solution for enhanced 3D data exploration, significantly improving the analysis process and communication of results in materials science.

36 - MATERIALS SCIENCE↗

Phase stability, mechanical properties, and ion irradiation effects in face-centered cubic CrFeMnNi compositionally complex solid-solution alloys at high temperatures

We report two CrFeMnNi face-centered cubic complex concentrated solid-solution alloys (CSA) have been evaluated for phase stability, mechanical properties, and radiation damage effects from heavy ions. Cr 18 Fe 27 Mn 27 Ni 28 and Cr 15 Fe 35 Mn 15 Ni 35 were predicted by thermodynamic calculations to phase separate and maintain a single phase at 700 °C, respectively. Aging experiments at this temperature confirmed varying degrees of precipitation of a body-centered cubic phase in both Cr 18 Fe 27 Mn 27 Ni 28 and Cr 15 Fe 35 Mn 15 Ni 35 . The alloys showed promising strength in tensile deformation at room temperature, with yield strengths of 155 MPa and 151 MPa for Cr 18 Fe 27 Mn 27 Ni 28 and Cr 15 Fe3 5 Mn 15 Ni 35 , respectively. At 500 °C, the yield strength of Cr 18 Fe 27 Mn 27 Ni 28 fell to 93 MPa, and to 100 MPa in Cr 15 Fe3 5 Mn 15 Ni 35 . Unlike Cr 18 Fe 27 Mn 27 Ni 28 , Cr 15 Fe 35 Mn 15 Ni 35 gained some ductility at 500 °C compared to room temperature. The two CSAs were irradiated to 75 dpa at 500 °C in the plateau region of the displacement curve using 3.7 MeV Ni 2+ ions, alongside model alloy 709 as a reference. Irradiation results produced similar densities and sizes of dislocations loops in the two CSAs compared to the reference. However, while large voids form in the plateau region of Cr 18 Fe 27 Mn 27 Ni 28 , small voids form just beyond the displacement peak of Cr 15 Fe 35 Mn 15 Ni 35 . Atom probe tomography and energy dispersive X-ray spectroscopy-equipped scanning transmission electron microscopes were used to characterize the alloys for changes in chemical distribution.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗