Engineering PapersSearch

SEARCH · Engineering Papers

Results for “electron counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Electrons and cosmic ray produced protons in Saturn's inner magnetosphere

The Cerenkov detector on Pioneer 11 previously observed Crand protons above 600 MeV in Saturn's inner magnetosphere, mixed with a poorly understood background of energetic electrons. The electron count is separated from the proton counts and the first-order angular distributions are established for each species. To do this the theoretical relationships among the harmonic coefficients of the count rate is used as a function of spacecraft roll angle. The majority of the counts were electrons with energy above several MeV; i.e., with drift periods shorter than the satellite orbital resonance. The electrons have isotropic pitch angle distributions, and the protons pancake over most of the region between Mimas and the rings, although there is a small region of dumbbell proton distributions in the vicinity of Janus and epimetheus.

Northrop, T. G.

Electrons and Cosmic Ray Produced Protons in Saturn's Inner Magnetosphere

The Cerenkov detector on Pioneer 11 previously observed Crand protons above 600 MeV in Saturn's inner magnetosphere, mixed with a poorly understood background of energetic electrons. The electron count is separated from the proton counts and the first-order angular distributions are established for each species. To do this the theoretical relationships among the harmonic coefficients of the count rate is used as a function of spacecraft roll angle. The majority of the counts were electrons with energy above several MeV; i.e., with drift periods shorter than the satellite orbital resonance. The electrons have isotropic pitch angle distributions, and the protons pancake over most of the region between Nimas and the rings, although there is a small region of dumbbell proton distributions in the vicinity of Janus and Epimetheus.

Northrop, T. G.

Electrons and cosmic ray produced protons in Saturn's inner magnetosphere

The Cerenkov detector on Pioneer 11 previously observed Crand protons above 600 MeV in Saturn's inner magnetosphere, mixed with a poorly understood background of energetic electrons. The electron count is separated from the proton counts and the first-order angular distributions are established for each species. To do this the theoretical relationships among the harmonic coefficients of the count rate is used as a function of spacecraft roll angle. The majority of the counts were electrons with energy above several MeV; i.e., with drift periods shorter than the satellite orbital resonance. The electrons have isotropic pitch angle distributions, and the protons pancake over most of the region between Nimas and the rings, although there is a small region of dumbbell proton distributions in the vicinity of Janus and Epimetheus.

Northrop, T. G.

Active experiments in modifying spacecraft potential: Results from ATS-5 and ATS-6

Instruments on ATS-5 and ATS-6 were operated to study the phenomena of spacecraft charging. The ion engine neutralizers were operated in attempts to modify the spacecraft potentials. The neutralizer on ATS-5 is a hot filament emitting electrons, while the neutralizer on ATS-6 is a low energy plasma bridge. The diagnostics used were particle detectors, counting electrons and protons as a function of energy. Operations were conducted in daylight and eclipse. This report describes the processing data from these and other operations. Only preliminary analysis of some of this data has been carried out, with the following results: (1) electron emission does not perturb the status of a low potential satellite by more than 50 volts, (2) emission of a low energy plasma does not change low potentials by more than a few volts, (3) when ATS-6 enters eclipse in the presence of a high energy plasma, the neutralizer suppresses any rise in (within a few volts resolution), (4) when the electron emitter on ATS-5 is operated, it serves to discharge negative potentials from thousands to hundreds of volts.

Olsen, R.

A general study of techniques for ultraviolet astrophysical studies on space vehicles

Recent accomplishments in three areas of UV instrumentation for space astronomy are discussed. These areas include reliable UV photometry, sensitive photon-detection techniques, and precise telescope pointing. Calibration facilities for spectrometers designed to operate in the spectral regions above 1200 A and down to 400 A are described which employ a series of diodes calibrated against electron synchrotron radiation as well as other radiometric standards. Improvements in photon-detection sensitivity achieved with the aid of pulse-counting electronics and multispectral detectors are reported, and the technique of precise subarcsecond telescope pointing is briefly noted. Some observational results are presented which demonstrate the advantages and precision of the instruments and techniques considered.

Moos, H. W.

Precipitating relativistic electrons - Their long-term effect on stratospheric odd nitrogen levels

Using electron count rate data at geostationary orbit, daily energy spectra, extending from 30 keV to 15 MeV, have been developed for trapped relativistic electrons at 6.6 earth radii. These spectra have been used to model the flux of these electrons into the atmosphere at 120 km. Energy deposition calculations permit daily sources of HO(x) and NO(y) to be calculated at auroral and subauroral latitudes due to relativistic electron precipitation (REP) for the period June 13, 1979, through June 4, 1988. Both short-term and long-term source variations are quite large over the period considered. The results suggest that a significant contribution to the anomalously large and unexplained global O3 declines between 1979 and 1985 has been made by the catalytic destruction of O3 by odd nitrogen in the lower stratosphere at mid to high latitudes. The results also provide evidence for a clear and strong linkage between solar variability, the state of the magnetosphere, and the chemical climatological state of the middle and lower atmosphere.

Callis, Linwood B.

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Detector systems based on the high gain microchannel plate (MCP) electron multiplier were used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse counting electronic readout systems provide zero readout noise, spatial resolutions (FWHM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can be developed to produce detectors with active areas of 100 nm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies at wavelengths between about 100 and 1A (approximately 0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described and the prospects for future developments are discussed.

Timothy, J. G.

Microchannel plates and image detection at soft X-ray wavelengths

Detector systems based on the high-gain microchannel plate (MCP) electron multiplier have been used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse-counting electronic readout systems provide zero readout-noise, spatial resolutions (FWM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can br developed to produce detectors with active areas of 100 mm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies to wavelengths between about 100 and 1A (0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described, and the prospects for future developments are discussed.

Timothy, J. G.

Energetic charged particles in the Uranian magnetosphere

The cosmic ray instrument on Voyager 2 obtained detailed charged particle data on the path the spacecraft followed through the newly-discovered Uranian magnetosphere. Notably, the electron counts did not rise above background until the spacecraft was deep in the magnetosphere. The data further indicated that the satellites Miranda, Ubriel and Ariel impose a sweep effect on MeV electrons, which move radially inward from some source in the outer magnetosphere or the magnetotail. The energetic particle data also supported a firm pitch angle dependence for proton energy spectra in the 1-8 MeV range. Finally, the particle density data were commensurate with a dipole magnetic field tilted 60.1 deg in relation to the planet and rotating every 17.4 hr, close to estimates from other instruments.

Stone, E. C.

Measurements of electron detection efficiencies in solid state detectors.

Detailed laboratory measurement of the electron response of solid state detectors as a function of incident electron energy, detector depletion depth, and energy-loss discriminator threshold. These response functions were determined by exposing totally depleted silicon surface barrier detectors with depletion depths between 50 and 1000 microns to the beam from a magnetic beta-ray spectrometer. The data were extended to 5000 microns depletion depth using the results of previously published Monte Carlo electron calculations. When the electron counting efficiency of a given detector is plotted as a function of energy-loss threshold for various incident energies, the efficiency curves are bounded by a smooth envelope which represents the upper limit to the detection efficiency. These upper limit curves, which scale in a simple way, make it possible to easily estimate the electron sensitivity of solid-state detector systems.

Lupton, J. E.

Effect of Electronic Shot Noise on Dynamic Measurements using Optical Techniques: Examples from Rayleigh Scattering and Unsteady PSP

Electronic shot noise is an unavoidable reality in all optical techniques that depend on measuring light intensity. For steady-state, time-averaged measurements the impact of shot noise can be easily reduced by increasing the exposure time, or by averaging over multiple-exposures. That is not the case for unsteady measurements, where time histories of light intensity variations need to be created either by high-speed photography (unsteady PSP) or via photoelectron counting (spectrally resolved Rayleigh scattering) over short time durations using a photo-multiplier tube (PMT) and photon counting electronics. Electronic shot noise introduces a fixed amount of random error, which can overwhelm the light intensity variation caused by turbulent fluctuations. Spectrum computed from such time series shows a fixed noise floor that is independent of the number of data points in the time series. For a fixed optical system, where the collected power of the luminescent light (uPSP), or the scattered light (Rayleigh) is fixed, one needs to resort to special techniques to obtain enough signal-to noise ratio (SNR). For the uPSP application it is shown that averaging of the adjacent pixels improves SNR; although this may lead to a sacrifice of spatial resolution. A second means is to increase the exposure time, which leads to a lowering of the frequency range. For the Rayleigh application, improvements of SNR can be achieved via two different cross-correlation based approaches. The first involves measuring the light intensity using two PMTs using short, contiguous gates; thereby, creating two time-series of data. The second one involves collecting one long time-series of data using one set of measurement device, followed by an odd-even splitting into two time series. When the two time-series are cross-correlated, and a power spectrum is calculated, a significant reduction in the shot noise floor can be achieved. Examples from measurements of density and velocity fluctuations spectra from two different Rayleigh setup are presented to demonstrate the process.

uPSP

A digital multichannel photometer

Semiconductor diode image tube system as digital multichannel photometer, noting cost, weight and size advantages over photomultiplier tube array with pulse counting electronics

Beaver, E. A.

Absolute calibration of ultraviolet filter photometry

The essential features of the calibration procedure can be divided into three parts. First, the shape of the bandpass of each photometer was determined by measuring the transmissions of the individual optical components and also by measuring the response of the photometer as a whole. Secondly, each photometer was placed in the essentially-collimated synchrotron radiation bundle maintained at a constant intensity level, and the output signal was determined from about 100 points on the objective. Finally, two or three points on the objective were illuminated by synchrotron radiation at several different intensity levels covering the dynamic range of the photometers. The output signals were placed on an absolute basis by the electron counting technique described earlier.

Bless, R. C.

Titan photometric parameters

Measurements of the irradiance of Titan from 0.05 to 1.08 micrometer were carried out by 60-inch reflector, spectrometer, and pulse counting electronics. An approximate contour of the geometric albedo assumes methane is the principal absorber. The albedo of Titan reaches a maximum value of 0.37 at 0.68, 0.753, and 0.83 micrometers, while in the center of the strongest absorption features, at 0.89 and 1.0. micrometer, it falls to 0.10. Comparison with the methane bands of Jupiter and Saturn indicates that the maxima clearly do not represent the continuum and that the lower values may well be depressed by wings of methane bands adjacent to them.

Younkin, R. L.

Preliminary interpretation of plasma electron observations at the third encounter of Mariner 10 with Mercury

Plasma electron count observations made during the first and third encounters of Mariner 10 with Mercury (i.e., during Mercury I and III) are reported. They provide detailed information on the magnetosphere of Mercury, especially those from Mercury III. A low-flux region was observed about closest approach (CA) of Mercury III, whereas no such region was detected by the lower-latitude Mercury I; a hot plasma sheet was measured on the outgoing (and near-equator) trajectory of Mercury I, while only cool plasma sheets were observed in the magnetosphere by Mercury III. Findings are similar, on a reduced scale, to models of the earth's magnetosphere and magnetosheath.

Hartle, R. E.