Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron beam stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

ON LANDAU DAMPING RESTORATION WITH ELECTRON LENSES IN SPACE-CHARGE DOMINATED BEAMS

It is shown that the Lorentz forces of a low-energy, magnetically stabilized electron beam, or “electron lens”, can introduce transverse nonlinear focusing sufficient for Landau damping of transverse beam instabilities in accelerators. Unlike other nonlinear elements, the electron lens can provide the frequency spread mainly at the desirable range of particle amplitudes, thus permitting to avoid the beam lifetime degradation.

43 PARTICLE ACCELERATORS↗

Pushing the limits of high-resolution polymer microscopy using antioxidants

High-resolution transmission electron microscopy (HRTEM) has been transformative to the field of polymer science, enabling the direct imaging of molecular structures. Although some materials have remarkable stability under electron beams, most HRTEM studies are limited by the electron dose the sample can handle. Beam damage of conjugated polymers is not yet fully understood, but it has been suggested that the diffusion of secondary reacting species may play a role. As such, we examine the effect of the addition of antioxidants to a series of solution-processable conjugated polymers as an approach to mitigating beam damage. Characterizing the effects of beam damage by calculating critical dose D c values from the decay of electron diffraction peaks shows that beam damage of conjugated polymers in the TEM can be minimized by using antioxidants at room temperature, even if the antioxidant does not alter or incorporate into polymer crystals. As a consequence, the addition of antioxidants pushes the resolution limit of polymer microscopy, enabling imaging of a 3.6Å lattice spacing in poly[(5,6-difluoro-2,1,3-benzothiadiazol-4,7-diyl)-alt-(3,3"-di(2-octyldodecyl)-2,2';5',2";5",2"-quaterthiophene-5,5"-diyl)] (PffBT4T-2OD).

36 MATERIALS SCIENCE↗

Megavolt bremsstrahlung measurements from linear induction accelerators demonstrate possible use as a FLASH radiotherapy source to reduce acute toxicity

Abstract Recent studies indicate better efficacy and healthy tissue sparing with high dose-rate FLASH radiotherapy (FLASH-RT) cancer treatment. This technique delivers a prompt high radiation dose rather than fractional doses over time. While some suggest thresholds of > 40 Gy s −1 with a maximal effect at > 100 Gy s −1 , accumulated evidence shows that instantaneous dose-rate and irradiation time are critical. Mechanisms are still debated, but toxicity is minimized while inducing apoptosis in malignant tissue. Delivery technologies to date show that a capability gap exists with clinic scale, broad area, deep penetrating, high dose rate systems. Based on these trends, if FLASH-RT is adopted, it may become a dominant approach except in the least technologically advanced countries. The linear induction accelerator (LIA) developed for high instantaneous and high average dose-rate, species independent charged particle acceleration, has yet to be considered for this application. We review the status of LIA technology, explore the physics of bremsstrahlung-converter-target interactions and our work on stabilizing the electron beam. While the gradient of the LIA is low, we present our preliminary work to improve the gradient by an order of magnitude, presenting a point design for a multibeam FLASH-RT system using a single accelerator for application to conformal FLASH-RT.

42 ENGINEERING↗

Beam Breakup Simulations for the Scorpius Flash-Radiography Accelerator

Beam breakup (BBU) in linear induction accelerators (LIAs) used for flash radiography is problematic because the high-frequency beam motion can blur the source spot, thereby degrading resolution. Amplification of BBU depends directly on details of cell design and is suppressed in operation by the solenoidal magnetic field focusing on the electron beam. Therefore, much effort has gone into design of the cells and magnetic focusing for the new Scorpius radiography LIA. Here, in this article, we use computer simulations to demonstrate that BBU in Scorpius should be no more than in present radiography LIAs at the Los Alamos National Laboratory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Searching for the Most Harmful Field Errors in the HSR IR Superconducting Magnets

In this project, we improve beam stability for the Electron-Ion Collider. Magnetic field errors can reduce beam stability, making it essential to identify the field errors that have the greatest impact on accelerator performance. However, this is particularly challenging because beam stability depends on the complex interactions of many magnetic field errors, resulting in a high-dimensional and nonlinear optimization problem. We determine which field errors are the most influential for the large physical aperture superconducting magnet B2PF, a critical magnet in the Interaction Region (IR) in the Hadron Storage Ring (HSR). We complete and analyze nearly 30,000 simulations on the Brookhaven National Laboratory Linux Cluster by varying 18 nonlinear magnetic field errors. We evaluate beam stability using the dynamic aperture and the tune diffusion. We identify the field errors that most strongly influence beam stability and establish quantitative field error tolerances that improve accelerator performance.

43 PARTICLE ACCELERATORS↗

Development of electron source feedback for enhanced X-ray beam stability at NSLS-II

Future synchrotron light sources are being designed to deliver significantly higher brightness and coherence, enabling faster scanning and more advanced imaging techniques. However, realizing these capabilities requires improved X-ray beam stability, as vibrations directly limit measurement accuracy and image quality. At the NSLS-II Hard X-ray Nanoprobe (HXN), a local mechanical feedback system mitigates low-frequency motion but provides only limited suppression of dominant vibrations at 27 Hz and 120 Hz. To address this limitation, this work explores the use of the electron beam itself as the actuator for feedback by integrating X-ray beam position monitor signals into the fast orbit feedback system through a dedicated electrometer. Experimental results show that this approach effectively suppresses the dominant vibration peaks and enhances stability at the focusing point. Benchmark ptychography measurements further confirm that electron-beam-based feedback reduces background fluctuations and mitigates vibration-induced artifacts under fast-scanning conditions. These results establish the feasibility of using the electron beam as a feedback actuator for next-generation synchrotron applications and provide an experimental assessment of its potential and limitations.

36 MATERIALS SCIENCE↗

Landau Damping with Electron Lenses in Space-Charge Dominated Beams

Further progress of fundamental physics requires accelerated beams of high intensity. The intensities, however, are limited by many factors, including coherent beam instabilities. Usual methods to control the instabilities, such as octupole magnets, beam feedback dampers and employment of chromatic effects, may be ineffective or insufficient. In this study, electron lenses were proposed as a means to provide stabilizing spread in the beam betatron frequencies. It was shown that electron lenses are uniquely effective for Landau damping of transverse beam instabilities in high energy particle accelerators, and that their employment does not compromise incoherent (single particle) stability, dynamic aperture and the beam lifetime. Here we consider effectiveness of the Landau damping with electron lenses when the space charge tune shift cannot be neglected. We demonstrate that the desired stability can be assured with proper choice of the electron beam parameters and current distributions.

43 PARTICLE ACCELERATORS↗

Atomic-scale modeling of C/N kinetic stability descriptors for PGM-free electrocatalysts at finite temperatures

The durability of platinum group metal-free (PGM-free) electrocatalysts is a major barrier to their usage in polymer electrolyte fuel cell cathodes. C and N removal from active sites may play an important role in the catalyst’s ability to maintain high activity. While C degradation mechanisms are kinetically controlled, previous studies have focused on thermodynamic descriptors. In this work, we develop a temperature-dependent kinetic descriptor of C and N stability using an electron beam-damage model. Our approach considers the electron beam energy threshold (EBET) describing the knock-on displacement of C and N atoms as a stability descriptor for atomic structures. The stability of different sites is calculated to be different showing this approach can discriminate between similar sites with varied configurations. Additionally, we provide important insight regarding TEM beam damage of proposed active sites. We calculate 60 keV electrons can damage some proposed active site structures even at room temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stable electron beam propagation in a plasma column

The stability of plasma-based accelerators against transverse misalignments and asymmetries of the drive beam is crucial for their applicability. Without stabilizing mechanisms, even small initial offsets of the drive beam centroid can couple coherently to the plasma wake, grow, and ultimately lead to emittance degradation or beam loss for a trailing witness beam. In this work, we demonstrate the intrinsic stability of a beam propagating in a plasma column. This result is relevant in the context of plasma-based positron acceleration, where a wakefield suitable for the transport and acceleration of a positron witness beam is generated in a plasma column by means of an electron drive beam. The stable propagation of the drive beam is a necessary condition for the experimental implementation of this scheme. The differences and similarities of stabilizing mechanisms in a plasma column compared to a homogeneous plasma are identified via theory and particle-in-cell simulations. Experimental tolerances are given, demonstrating the experimental feasibility of the scheme.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solving the auroral-arc-generator question by using an electron beam to unambiguously connect critical magnetospheric measurements to auroral images

Here, an active mapping mission is described that unambiguously connects measurements in the Earth's magnetosphere to visible aurora in the atmosphere. The core of the mission is an electron-beam source operated on a spacecraft in the equatorial magnetosphere, with the electron beam traveling along the Earth's magnetic-field lines to the atmosphere, depositing its energy to create an optical beam-spot in the atmosphere at the footpoint of the spacecraft's magnetic-field line. This optical spot can be imaged by ground-based cameras, putting the location of the spacecraft's magnetic footpoint into the context of the optical aurora. Scientific instruments carried on the spacecraft make critical measurements of the properties of the magnetosphere at the locations where the magnetosphere powers the aurora, allowing the determination of the plasma-physics mechanisms by which the magnetosphere drives the aurora, in particular answering the outstanding question of how the magnetosphere drives low-latitude auroral arcs. Long-standing questions in magnetosphere-ionosphere coupling that have not been answered because we could not unambiguously connect locations in the magnetosphere with their image in the ionosphere will finally be addressed. In this paper the properties of a “standard” growth-phase auroral arc are collected, theories of the magnetospheric generation of auroral arcs are reviewed, and critical magnetospheric measurements to discern the mechanisms that drive auroral arcs are determined. Further, the plasma physics of the experiment is investigated, including spacecraft-charging mitigation, beam stability, beam scattering, and electron orbit theory. Tradeoffs (keV versus MeV) concerning the energy of the electron beam are enumerated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A MHz-repetition-rate hard X-ray free-electron laser driven by a superconducting linear accelerator

The European XFEL is a hard X-ray free-electron laser (FEL) based on a high-electron-energy superconducting linear accelerator. The superconducting technology allows for the acceleration of many electron bunches within one radio-frequency pulse of the accelerating voltage and, in turn, for the generation of a large number of hard X-ray pulses. In this paper, we report on the performance of the European XFEL accelerator with up to 5,000 electron bunches per second and demonstrating a full energy of 17.5 GeV. Feedback mechanisms enable stabilization of the electron beam delivery at the FEL undulator in space and time. The measured FEL gain curve at 9.3 keV is in good agreement with predictions for saturated FEL radiation. Hard X-ray lasing was achieved between 7 keV and 14 keV with pulse energies of up to 2.0 mJ. Using the high repetition rate, an FEL beam with 6 W average power was created.

43 PARTICLE ACCELERATORS↗

Controlled Injection of Electrons for Improved Performance of Laser-Wakefield Acceleration

Our lab performed a series of experiments on controlled injection of LWFA with two extreme laser pulses: one laser pulse was used to drive LWFA. In contrast, the other precisely controls the injection of electrons into the wakefield plasma wave. We have demonstrated an efficient reduction of electron beam emittance by optical injection and novel spatio-temporal manipulation of the electron beam by the extreme laser-plasma waves. Moreover, the optical injection process involves unprecedented new physics, which will benefit studies in astrophysics, inertial confinement fusion, laser-driven x-ray light sources, and ultrafast science. We further improved the performance of LWFA by a better understanding and control of the extreme laser-plasma wave dynamics for optical injection. Three novel mechanisms were identified in the optical injection process: (1) collision of two laser pulses, (2) collision of a laser pulse with a wakefield plasma wave, and (3) collision of two laser wakefields. All three methods improved electron-beam energy spread, emittance, stability, and reproducibility. First, we identified, compared, and independently controlled these different injection mechanisms by controlling the polarization of the injector laser pulse. Second, we manipulated the spatiotemporal splitting of LWFA electron beams to reduce their emittance. Third, we applied the same laser-plasma-wave dynamics and the same experimental setup for improved performance of ion acceleration, which has also been predicted by the recent simulations.

43 PARTICLE ACCELERATORS↗

Electron Cloud Simulations In The Fermilab Recycler

We present a simulation study to characterize the stability region of the Fermilab (FNAL) Recycler in the context of secondary emission yield (SEY). Interactions between electrons and beam pipe material can produce electron clouds that jeopardize beam stability in certain focusing configurations. Such an instability was documented in the Recycler, and the work presented here reflects improvements to better understand that finding. We incorporated the Furman-Pivi Model into a PyECLOUD analysis, and we determined the instability threshold given various bunch lengths, intensities, SEY magnitudes, and model parameters.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Femtosecond Compression Dynamics and Timing Jitter Suppression in a THz-driven Electron Bunch Compressor

Herein we present the first demonstration of THz driven bunch compression and timing stabilization of a relativistic electron beam. Quasi-single-cycle strong field THz radiation is used in a shorted parallel-plate structure to compress a few-fC beam with 2.5 MeV kinetic energy by a factor of 2.7, producing a 39 fs rms bunch length and a reduction in timing jitter by more than a factor of 2 to 31 fs rms. This THz driven technique offers a significant improvement to beam performance for applications like ultrafast electron diffraction, providing a critical step towards unprecedented timing resolution in ultrafast sciences, and other accelerator applications using femtosecond-scale electron beams.

43 PARTICLE ACCELERATORS↗

Wehnelt photoemission in an ultrafast electron microscope: Stability and usability

We tested and compared the stability and usability of three different cathode materials and configurations in a thermionic-based ultrafast electron microscope: (1) on-axis thermionic and photoemission from a custom 100 μm diameter LaB 6 source with a graphite guard ring, (2) off-axis photoemission from the Ni aperture surface of the Wehnelt electrode, and (3) on-axis thermionic and photoemission from a custom 200 μm diameter polycrystalline Ta source. For each cathode type and configuration, including the Ni Wehnelt aperture, we illustrate how the photoelectron beam-current stability is deleteriously impacted by simultaneous cooling of the source following thermionic heating. Furthermore, we demonstrate usability via collection of parallel- and convergent-beam electron diffraction patterns and by formation of the optimum probe size. We find that usability of the off-axis Ni Wehnelt-aperture photoemission is at least comparable to on-axis LaB 6 thermionic emission, as well as to on-axis photoemission [the heretofore conventional approach to ultrafast electron microscopy (UEM) in thermionic-based instruments]. However, the stability and achievable beam currents for off-axis photoemission from the Wehnelt aperture were superior to that of the other cathode types and configurations, regardless of the electron-emission mechanism. Beam-current stability for this configuration was found to be ±1% (one standard deviation from the mean) for 70 min (longest duration tested), and steady-state beam current was reached within the sampling-time resolution used here (~1 s) for 15 pA beam currents (i.e., 460 electrons per packet for a 200 kHz repetition rate). Repeatability and robustness of the steady-state condition were also found to be within ±1% of the mean. We discuss the implications of these findings for UEM imaging and diffraction experiments, for pulsed-beam damage measurements, and for practical switching between optimum conventional TEM and UEM operation within the same instrument.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beam physics research with the IOTA electron lens

The electron lens in the Fermilab Integrable Optics Test Accelerator (IOTA) will enable new research in nonlinear integrable optics, space-charge compensation, electron cooling, and the stability of intense beams. This research addresses scientific questions on high-brightness beams and operational challenges of high-power accelerators for nuclear and particle physics. We review the roles that electron lenses play in this field and the physical principles behind their applications. The design criteria and specifications for the IOTA storage ring and electron lens are then discussed. We conclude with a description of the components of the apparatus.

43 PARTICLE ACCELERATORS↗