Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electromyography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Dry electrodes with a printed cellulose–graphene ink for low-profile strain sensors in electromyography

Dihydrolevoglucosenone, commonly known as Cyrene, is a renewable and fully biodegradable cellulose-waste derived, environmentally friendly solvent, presenting a non-toxic alternative to N-methyl-2-pyrrolidone (NMP). Currently, solution-based processing of graphene and other similar van der Waals solids favor toxic solvents such as NMP, limiting their use for biosensing. However, with the use of Cyrene, bio-compatible printable devices are possible, and studies have already demonstrated its use in temperature and other biosensing methods through screen-printing. Screen-printing unfortunately often requires masks that constrain the minimum acquirable feature size to be above hundreds of centimeters and wastes material, adding to process complexity and cost. Conversely, inkjet-printing is an attractive alternative for the maskless patterning of hierarchically assembled structures, with micron length scales attainable. Graphene's high conductivity positions it ideally for long-wear sensors such as dry electrodes or respiration monitors. Here, we demonstrate the potential of Cyrene-based graphene inks through few-layer inkjet printing on flexible substrates for the first time, to produce non-toxic conductors toward a strain-mediated mechanism for biosensing, used to detect bodily motion for wearable electronics. The challenges overcome in this study include engineering ink chemistry and printing parameters such that Cyrene's relatively high viscosity compared to typical inkjet solvents, still allows for droplet ejection in a conventional material printer, yielding well-resolved clean line-edges in contrast to other solvents that exhibit diffuse line-edges possibly from stray droplets and ink-splashing. Temperature-dependent transport measurements on the inkjet-printed Cyrene-based graphene films showed the conductivity to be largely temperature-invariant but at lower temperatures below 100 K, conductivity decreased, likely as a result of increased inter-membrane separation arising from thermal contraction. Additionally, temperature-dependent Raman spectroscopy showed the red-shift in the G-band, 2D-band and D-band peaks, as temperature increased. As a result, by validating flexion motion detection of the proximal interphalangeal joint demonstrated in this study, our work is the first of its kind to successfully additively manufacture inkjet-printed Cyrene-based graphene strain sensors on flexible substrates for bio-sensing and wearables.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterisation of motor cortex organisation in patients with different presentations of persistent low back pain

Abstract Persistence of low back pain is thought to be associated with different underlying pain mechanisms, including ongoing nociceptive input and central sensitisation. We hypothesised that primary motor cortex (M1) representations of back muscles (a measure of motor system adaptation) would differ between pain mechanisms, with more consistent observations in individuals presumed to have an ongoing contribution of nociceptive input consistently related to movement/posture. We tested 28 participants with low back pain sub‐grouped by the presumed underlying pain mechanisms: nociceptive pain, nociplastic pain and a mixed group with features consistent with both. Transcranial magnetic stimulation was used to study M1 organisation of back muscles. M1 maps of multifidus (deep and superficial) and longissimus erector spinae were recorded with fine‐wire electromyography and thoracic erector spinae with surface electromyography. The nociplastic pain group had greater variability in M1 map location (centre of gravity) than other groups ( p < .01), which may suggest less consistency, and perhaps relevance, of motor cortex adaptation for that group. The mixed group had greater overlap of M1 representations between deep/superficial muscles than nociceptive pain (deep multifidus/longissimus: p = .001, deep multifidus/thoracic erector spinae: p = .008) and nociplastic pain (deep multifidus/longissimus: p = .02, deep multifidus/thoracic erector spinae: p = .02) groups. This study provides preliminary evidence of differences in M1 organisation in subgroups of low back pain classified by likely underlying pain mechanisms. Despite the sample size, differences in cortical re‐organisation between subgroups were detected. Differences in M1 organisation in subgroups of low back pain supports tailoring of treatment based on pain mechanism and motor adaptation.

Elgueta‐Cancino, Edith↗

Topological supramolecular network enabled high-conductivity, stretchable organic bioelectronics

Intrinsically stretchable bioelectronic devices based on soft and conducting organic materials have been regarded as the ideal interface for seamless and biocompatible integration with the human body. A remaining challenge is to combine high mechanical robustness with good electrical conduction, especially when patterned at small feature sizes. We develop a molecular engineering strategy based on a topological supramolecular network, which allows for the decoupling of competing effects from multiple molecular building blocks to meet complex requirements. We obtained simultaneously high conductivity and crack-onset strain in a physiological environment, with direct photopatternability down to the cellular scale. We further collected stable electromyography signals on soft and malleable octopus and performed localized neuromodulation down to single-nucleus precision for controlling organ-specific activities through the delicate brainstem.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring the Interaction Between Head-Supported Mass, Posture, and Visual Stress on Neck Muscle Activation

Objective Assess neck muscle activity for varying interactions between helmet, posture, and visual stress in a simulated “helo-hunch” posture. Background Military aviators frequently report neck pain (NP). Risk factors for NP include head-supported mass, awkward postures, and mental workload. Interactions between these factors could induce constant low-level muscle activation during helicopter flight and better explain instances of NP. Method Interactions between physical loading (helmet doffed/donned), posture (symmetric/asymmetric), and visual stress (low/high contrast) were studied through neck muscle electromyography (EMG), head kinematics, subjective discomfort, perceived workload, and task performance. Subjects ( n = 16) performed eight 30-min test conditions (varied physical loading, posture, and visual stress) while performing a simple task in a simulated “helo-hunch” seating environment. Results Conditions with a helmet donned had fewer EMG median frequency cycles (which infer motor unit rotation for rest/recovery, where more cycles are better) in the left cervical extensor and left sternocleidomastoid. Asymmetric posture (to the right) resulted in higher normalized EMG activity in the right cervical extensor and left sternocleidomastoid and resulted in less lateral bending compared with neutral across all conditions. Conditions with high visual stress also resulted in fewer EMG cycles in the right cervical extensor. Conclusion A complex interaction exists between the physical load of the helmet, postural stress from awkward postures, and visual stress within a simulated “helo-hunch” seating environment. Application These results provide insight into how visual factors influence biomechanical loading. Such insights may assist future studies in designing short-term administrative controls and long-term engineering controls.

Behavioral Sciences↗