Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Heart Rate Monitors

Under a NASA grant, Dr. Robert M. Davis and Dr. William M. Portnoy came up with a new type of electrocardiographic electrode that would enable long term use on astronauts. Their invention was an insulated capacitive electrode constructed of a thin dielectric film. NASA subsequently licensed the electrode technology to Richard Charnitski, inventor of the VersaClimber, who founded Heart Rate, Inc., to further develop and manufacture personal heart monitors and to produce exercise machines using the technology for the physical fitness, medical and home markets. Same technology is on both the Home and Institutional Model VersaClimbers. On the Home Model an infrared heart beat transmitter is worn under exercise clothing. Transmitted heart rate is used to control the work intensity on the VersaClimber using the heart rate as the speedometer of the exercise. This offers advantages to a full range of users from the cardiac rehab patient to the high level physical conditioning of elite athletes. The company manufactures and markets five models of the 1*2*3 HEART RATE monitors that are used wherever people exercise to accurately monitor their heart rate. Company is developing a talking heart rate monitor that works with portable headset radios. A version of the heart beat transmitter will be available to the manufacturers of other aerobic exercise machines.

Source record↗

Key Experimental Considerations When Evaluating Functional Ionic Liquids for Combined Capture and Electrochemical Conversion of CO 2

Ionic liquids (ILs) are considered functional electrolytes for the electrocatalytic reduction of CO 2 (ECO 2 R) due to their role in the double-layer structure formation and increased CO 2 availability at the electrode surface, which reduces the voltage requirement. However, not all ILs are the same, considering the purity and degree of the functionality of the IL. Further, there are critical experimental factors that impact the evaluation of ILs for ECO 2 R including the reference electrode, working electrode construction, cosolvent selection, cell geometry, and whether the electrochemical cell is a single compartment or a divided cell. Here, we describe improved synthesis methods of imidazolium cyanopyrrolide IL for electrochemical studies in consideration of precursor composition and reaction time. We explored how IL with cosolvents (i.e. acetonitrile, dimethylformamide, dimethyl sulfoxide, propylene carbonate, and n-methyl-2-pyrrolidone) affects conductivity, CO 2 mass transport, and ECO 2 R activation overpotential together with the effects of electrode materials (Sn, Ag, Au, and glassy carbon). Acetonitrile was found to be the best solvent for lowering the onset potential and increasing the catalytic current density for the production of CO owing to the enhanced ion mobility in combination with the silver electrode. Further, the ECO 2 R activity of molecular catalysts Ni(cyclam)Cl 2 and iron tetraphenylsulfonato porphyrin (FeTPPS) on the carbon cloth electrode maintained high Faradaic efficiencies for CO in the presence of the IL. This study presents best practices for examining nontraditional multifunctional electrolytes amenable to integrated CO 2 capture and conversion technologies for homogeneous and heterogeneous ECO 2 R.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Internally folded expanded metal electrode for battery construction

A battery system is disclosed which includes folded grids of expanded metal inserted through non-conductive substrates and pasted with electrochemically active materials. In the most preferred embodiment, a frame is provided with a plastic insert, and slots are provided in the latter to receive the expanded metal grid. After suitable coinage of the grid and insertion through the plastic film, the grid is sealed and pasted on opposite sides with positive and negative active material. A battery is assembled using one or a plurality of the resulting electrode elements, with separators, to produce a high-power, lead-acid battery. The folded grid provides many of the design benefits of standard bipolar construction.

Korinek, Paul D.↗

SiO 2 Is Wasted Space in Single-Nanometer-Scale Silicon Nanoparticle-Based Composite Anodes for Li-Ion Electrochemical Energy Storage

The electrode processing conditions of silicon-based composite anodes play a pivotal role in the resulting interfacial chemical speciation and, thus, the electrochemical cycling behavior of the electrode. Systematically investigating how small chemical changes to the surface of the silicon nanoparticle (NP) affect larger, electrode-level properties is a strategy that will inform design principles to maximize electrode energy density and extend electrode lifetime. Here, we incorporate silicon nanoparticles (NPs) with an average diameter of 5.5 nm synthesized from the gas phase through a nonthermal plasma method into composite anode half-cell coin cells. We perform chemistry to functionalize the native hydride-terminated silicon NP surface with N-methylpyrrolidone (NMP) to improve slurry properties and reduce the silicon reactivity prior to composite electrode fabrication. We construct composite electrodes from these silicon NPs and observe an 86% capacity retention over 100 cycles at a rate of C/5, with an initial silicon specific capacity of 2600 mAh/g. We expose the same Si NPs to water that completely oxidizes these small-diameter NPs to SiO 2 and find that the SiO 2 NPs in the same electrode configuration exhibit no obvious lithium alloying capacity in the electrochemical potential range of lithium silicide alloy formation. As this result stands in contrast to existing literature, we provide a discussion on the origin of the discrepancies.

25 ENERGY STORAGE↗

Effect of crystallite geometries on electrochemical performance of porous intercalation electrodes by multiscale operando investigation

Lithium-ion batteries are yet to realize their full promise because of challenges in the design and construction of electrode architectures that allow for their entire interior volumes to be reversibly accessible for ion storage. Electrodes constructed from the same material and with the same specifications, which differ only in terms of dimensions and geometries of the constituent particles, can show surprising differences in polarization, stress accumulation and capacity fade. Here, using operando synchrotron X-ray diffraction and energy dispersive X-ray diffraction (EDXRD), we probe the mechanistic origins of the remarkable particle geometry-dependent modification of lithiation-induced phase transformations in V2O5 as a model phase-transforming cathode. A pronounced modulation of phase coexistence regimes is observed as a function of particle geometry. Specifically, a metastable phase is stabilized for nanometre-sized spherical V2O5 particles, to circumvent the formation of large misfit strains. Spatially resolved EDXRD measurements demonstrate that particle geometries strongly modify the tortuosity of the porous cathode architecture. Greater ion-transport limitations in electrode architectures comprising micrometre-sized platelets result in considerable lithiation heterogeneities across the thickness of the electrode. These insights establish particle geometry-dependent modification of metastable phase regimes and electrode tortuosity as key design principles for realizing the promise of intercalation cathodes. Designing electrode architectures for Li-ion batteries that can be reversibly accessible for ion storage can be challenging. Using operando techniques the mechanistic origin of lithiation-induced phase transformations in a V2O5 model cathode is now clarified.

Luo, Yuting↗

Method and Apparatus for Automated Isolation of Nucleic Acids from Small Cell Samples

RNA isolation is a ubiquitous need, driven by current emphasis on microarrays and miniaturization. With commercial systems requiring 100,000 to 1,000,000 cells for successful isolation, there is a growing need for a small-footprint, easy-to-use device that can harvest nucleic acids from much smaller cell samples (1,000 to 10,000 cells). The process of extraction of RNA from cell cultures is a complex, multi-step one, and requires timed, asynchronous operations with multiple reagents/buffers. An added complexity is the fragility of RNA (subject to degradation) and its reactivity to surface. A novel, microfluidics-based, integrated cartridge has been developed that can fully automate the complex process of RNA isolation (lyse, capture, and elute RNA) from small cell culture samples. On-cartridge cell lysis is achieved using either reagents or high-strength electric fields made possible by the miniaturized format. Traditionally, silica-based, porous-membrane formats have been used for RNA capture, requiring slow perfusion for effective capture. In this design, high efficiency capture/elution are achieved using a microsphere-based "microfluidized" format. Electrokinetic phenomena are harnessed to actively mix microspheres with the cell lysate and capture/elution buffer, providing important advantages in extraction efficiency, processing time, and operational flexibility. Successful RNA isolation was demonstrated using both suspension (HL-60) and adherent (BHK-21) cells. Novel features associated with this development are twofold. First, novel designs that execute needed processes with improved speed and efficiency were developed. These primarily encompass electric-field-driven lysis of cells. The configurations include electrode-containing constructs, or an "electrode-less" chip design, which is easy to fabricate and mitigates fouling at the electrode surface; and the "fluidized" extraction format based on electrokinetically assisted mixing and contacting of microbeads in a shape-optimized chamber. A secondary proprietary feature is in the particular layout integrating these components to perform the desired operation of RNA isolation. Apart from a novel functional capability, advantages of the innovation include reduced or eliminated use of toxic reagents, and operator-independent extraction of RNA.

Sundaram, Shivshankar↗

Fabrication of nano-gap electrode arrays by the construction and selective chemical etching of nano-crosswire stacks

Methods of fabricating nano-gap electrode structures in array configurations, and the structures so produced. The fabrication method involves depositing first and second pluralities of electrodes comprising nanowires using processes such as lithography, deposition of metals, lift-off processes, and chemical etching that can be performed using conventional processing tools applicable to electronic materials processing. The gap spacing in the nano-gap electrode array is defined by the thickness of a sacrificial spacer layer that is deposited between the first and second pluralities of electrodes. The sacrificial spacer layer is removed by etching, thereby leaving a structure in which the distance between pairs of electrodes is substantially equal to the thickness of the sacrificial spacer layer. Electrode arrays with gaps measured in units of nanometers are produced. In one embodiment, the first and second pluralities of electrodes are aligned in mutually orthogonal orientations.

Son, Kyung-Ah↗

Acoustic Gaussian Far-Field Pattern

Gaussian profile achieved by using annular electrodes. Transducer constructed by deposting circularly symmetric metallic multielectrode array on 12.7 mm diameter X-cut quartz disk. Each electrode independently connected to impedance network optimized to produce Gaussian distribution with less than 2 percent error. Ultrasonic transducer produces far field beam with Gaussian spatial profile for materials evaluation applications.

Claus, R. O.↗

Implantable electrode for recording nerve signals in awake animals

An implantable electrode assembly consisting of collagen and metallic electrodes was constructed to measure simultaneously neural signals from the intact nerve and bioelectrical noises in awake animals. Mechanical artifacts, due to bodily movement, were negligibly small. The impedance of the collagen electrodes, measured in awake cats 6-7 days after implantation surgery, ranged from 39.8-11.5 k ohms at a frequency range of 20-5 kHz. Aortic nerve activity and renal nerve activity, measured in awake conditions using the collagen electrode, showed grouped activity synchronous with the cardiac cycle. Results indicate that most of the renal nerve activity was from postganglionic sympathetic fibers and was inhibited by the baroceptor reflex in the same cardiac cycle.

Ninomiya, I.↗

Further development and application of polycrystalline metal whiskers

High strength metal whiskers have a larger versatile field of application than monocrystalline whiskers. Although polycrystalline metal whiskers can be used for composites, preferably by extrusion in thermoplastics or by infiltration of resins or metals into whisker networks, the chief application at present may be the production and various use of whisker networks. Such networks can be produced up to high degrees of porosity and besides high mechanical strength, they have high inside surfaces and high electric conductivity. There are for instance, applications concerning construction of electrodes for batteries and fuel cells, catalysts and also new heat-exchanger material, capable of preparing fuel oil and gasoline in order to assist a high-efficiency combustion. The technical application of polycrystalline metal whiskers require their modification as well as the construction of a pilot production unit.

Schladitz, H. J.↗

Challenges and Prospects of All-Solid-State Electrodes for Solid-State Lithium Batteries

In the development of all-solid-state lithium batteries (ASSLB), progress is made with solid-state electrolytes; however, challenges regarding compatibility and stability still exist with solid electrodes. These issues result in a low battery capacity and short cycle life, which limit the commercial application of ASSLBs. Here, this review summarizes the recent research progress on solid-state electrodes in ASSLBs including the solid–solid interface phenomena such as the interface between electrode materials and electrolytes. The mechanical stability problems in solid electrodes, including fracture, brittleness, and deformation of electrode materials, are also discussed, and corresponding methods to measure the solid electrode stress are provided. In addition, strategies for mitigating stress-related issues are examined. Finally, the fabrication process of solid electrodes is introduced and their future developments, including the exploration of new electrode materials and the design of more intelligent electrode structures, are proposed.

25 ENERGY STORAGE↗

Heart Rate Monitor

In the mid 70's, NASA saw a need for a long term electrocardiographic electrode suitable for use on astronauts. Heart Rate Inc.'s insulated capacitive electrode is constructed of thin dielectric film applied to stainless steel surface, originally developed under a grant by Texas Technical University. HRI, Inc. was awarded NASA license and continued development of heart rate monitor for use on exercise machines for physical fitness and medical markets.

Source record↗

Development of a Robust Reference Electrode in Aggressive Chemical and Radiation Environments in the Hanford Waste Tanks

The Hanford site stores more than 200 million liters of radioactive and chemically hazardous wastes from the production of weapons materials. The wastes are stored in 177 underground carbon-steel storage tanks, separated between 149 single shell tanks (SSTs) and 28 double shell tanks (DSTs). The DSTs provide critical retrieval and interim storage before the waste is vitrified in the Waste Treatment and Isolation Plant (WTP). The tanks will need to remain in-service far beyond the initial 40-year design life, and effective corrosion control practices must remain in force to extend the tanks’ lifespans. This effort includes direct measurements of corrosion rate (e.g., ultrasonic measurements and corrosion coupons) and electrochemical processes (e.g., linear polarization measurements and open circuit potential measurements). The Hanford site began monitoring the corrosion potential in select DSTs in 2008. Of the 45 reference electrodes that have been installed, 29 have failed and 6 others provided unreliable results. DOE-EM is supporting a 3-year program to develop a chemical and radiation resistant reference electrode for application in the Hanford tanks. The first year of the program focused on understanding the failure mechanism for the reference electrodes and identification of candidate construction materials that would mitigate degradation of the electrodes in the waste environment. During the second year of the program, the objectives were to: 1) test candidate materials under simulated waste conditions, 2) design components that will extend the service life of the electrode, 3) fabricate materials for prototype reference electrodes, and 4) assemble prototype reference electrodes for accelerated testing. The reference electrode is constructed of four principal parts: 1) junction, 2) casing, 3) inner chamber backfill materials, and 4) the sensing wire. Principally, improvements of the junction, casing, and inner chamber backfill materials are being pursued. The junction material at the interface between the waste and the inner chamber of the reference electrode was identified as a critical component in the failure of the reference electrodes. Nine candidate replacement junction materials were tested under simulated waste conditions to evaluate permeation rate. These materials included a variety of polymeric and ceramic materials, some of which were 3-D printed. Thus far, porous polyvinylidene fluoride materials have performed satisfactorily and are being considered for prototype development. The commercial electrode casing materials in general have performed well. Additionally, 3-D printing of chemically and mechanically stable materials is being investigated as a means for further improvement in fabrication consistency. SRNL has also investigated altering the reference electrode design to extend the service life. The new design of the interior of the reference electrode casing creates a longer, more tortuous path between the junction material and the electrode sensing wire. A finite element model was used to optimize the design without adversely impacting the circuit resistance of the electrode during the measurements, thus preserving the measurement accuracy while enhancing the service life. The inner chamber back fill materials are also critical to the performance of the reference electrode. Materials that are resistant to intruding tank waste and provide a conductive path to the sensing wire were investigated. Gel and powder materials that are interspersed with a conductive chloride bearing material were tested for their influence on diffusion and electrode resistance. All the investigated materials and components will be assembled, with collaboration from commercial vendors, to fabricate the initial prototypes. Accelerated testing of the prototypes will be initiated in Year 2 of the program and will be completed in Year 3. A recommendation on the materials of construction and the design of the new robust reference electrode will be presented to the Hanford tank farm facility.

Sykes, Kiana [Savannah River National Laboratory (↗

Ultrasonic transducer with a two-dimensional Gaussian field profile

A transducer is described which generates a two-dimensional Gaussian field by controlling both the position of multiple circular electrodes and the voltage applied to each electrode. The transducer is constructed by depositing concentric rings electrodes onto one flat surface of a circular piezoelectric crystal disk and attaching the rings to an impedance matching network which acts as a voltage divider. Geometrical inter-ring separations and electrical inter-ring impedances are designed to minimize the error between the generated acoustic field, modeled as a piecewise linear function, and the desired Gaussian distribution. Total mean squared error between the averaged far-field data and a Gaussian shape is less than two percent.

Claus, R. O.↗

A three-dimensional pore-scale model for redox flow battery electrode design analysis

A three-dimensional (3-D) pore-scale model has been developed to construct multiscale fibrous electrodes for redox flow batteries (RFB). New designs, such as biporous electrodes modify electrode structures by creating secondary pores on single carbon fiber to reduce internal battery resistance. Existing pore-scale models only resolve electrodes to the single carbon fiber scale and cannot incorporate recent multiscale electrode designs into numerical models. Our new model aims to bridge this gap and provide a tool to rapidly screen new electrode configurations. Two multiscale electrodes, laser-perforated and biporous electrodes, were investigated at varying operation conditions with the proposed 3-D pore-scale models. The laser-perforated electrode exhibits a reduced pressure drop, but follows the same permeability correlation compared to the corresponding pristine electrode. For the biporous electrode, the added specific surface area and faster reaction kinetics from the secondary pores are the most influential factors leading to improved battery efficiency. However, operating the biporous electrode in limiting current density conditions should be avoided due to the decreased mass transfer efficiency and a more significant voltage loss. Finally, we believe that our 3-D pore-scale model can accelerate the flow battery electrode design process and provide new insights into electrode geometry optimizations.

25 ENERGY STORAGE↗