Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrochemical printing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Printed Electrochemical Sensor for Quantifying Bone Density Loss in Microgravity

Printed electrochemical biosensors have been developed for astronaut point-of-care testing. Our fabrication approach is complimentary with in-space manufacturing for an on-demand and hands-free fabrication process. These sensors are developed using a combination of thin film materials printing and 3D printing and are comprised of carbon nanotube, gold nanoparticle, silver nanoparticle and dielectric inks to make traditional electrochemical sensor devices. Initial prototyped printed electrochemical sensors demonstrate good electrochemical performance while also displaying low batch to batch variability. Here we report the development of a printed sensor to monitor bone turnover. The absence of load bearing forces experienced in microgravity causes a reduction of overall bone mass and results in the development of space osteopenia/osteoporosis.(1,2) Our approach to identify space osteopenia/osteoporosis is to monitor the change in bone mass indirectly through an excreted biomarker of bone remodeling, amino-terminal collagen crosslinks (NTX). Antibodies specific to NTX are added to the sensor’s electrode ink and applied during the manufacturing process. NTX is measured from a urine sample by changes in voltammetry and electrochemical impedance as it binds to the antibody modified electrode surface. The measurement is rapid, quantitative and requires only small handheld electronics to perform the measurement. By this process, ground and flight physicians will receive frequent and real-time insight into the development of space osteopenia/osteoporosis to guide appropriate countermeasures. REFERENCES [1] Nabavi, N. et al (2011) Bone 49, 965-974. [2] Tamma, R. et al (2009) FASEB J 23, 2549-2554.

in-space manufacturing↗

Autonomous Measurement of Electrochemical Redox Couples for In-Situ Characterization of Enceladus Plume Samples

A 3D-printed microfluidic electrochemical cell with integrated electrodes was developed to demonstrate autonomous in-situ electrochemical characterization of terrestrial seawater samples. The system is designed to extend the capabilities of the 2008 Phoenix Lander’s Wet Chemistry Laboratory (WCL) that analyzed the soluble chemistry of the Martian soil, by miniaturizing its fluidic architecture for analysis of µL-volume samples as expected from an Enceladus fly-by mission. The microfluidic device has a total fluid volume of 48 µL and includes dual channels each populated with 7 electrodes. Measurement of pH was measured using an iridium oxide electrode. Cyclic voltammetry with Au, Pt, and glassy carbon working electrodes was used to measure redox couples in synthetic seawater that contained inorganic and bio-organic molecules. Glassy carbon was found to have minimal risk of interference from constituents of synthetic seawater when measuring molecular organic redox species; however, care must be used to prevent interference due to potential oxidation or dissolution in the case of Au working electrodes. A completely autonomous end-to-end run including sample delivery was performed, to demonstrate the feasibility of microfluidic-based cyclic voltammetry measurements for in-situ characterization of redox couples in Ocean World samples.

Planetary Instruments↗

Metabolic Vessel for Impedance Spectroscopy and Electrochemistry (MVISE): The Ground Mapping Unit for the Lunar Explorer Instrument for Space Biology Applications (LEIA)​

The BioSensor payload on the upcoming LEIA platform aboard a CLPS lander will carry yeast to the moon to study response to radiation and lunar gravity. The LEIA BioSensor is designed to monitor metabolic activity using absorbance in conjunction with alamarBlue for measuring colorimetric changes as proxy measurement for redox potential. The science data returned from small spacecraft mission modules like LEIA is limited as it relies solely on optical measurements, necessitating a corresponding ground mapping unit that is equipped with multiple electrochemical sensors for accurate mapping of the optical data and operates fully automatically. This technology development work discusses the extensive design and optimization efforts put into the ground mapping unit, MVISE. MVISE is a custom designed, 3D-printed vessel with an agitation system, with six different electrochemical sensor probes, and ports for sample collection and a pressure release valve. The sensors provide real-time data, with dry absorbance measurements aligning with LEIA flight hardware and wet measurements demonstrating invasive sensor design enabling a comparison between the two setups. The 3D printer resin was tested for mechanical robustness, biocompatibility, and resistance to autoclave sterilization. The inner walls were coated with food-grade epoxy, ensuring a smooth finish to prevent microbial lodging and dye staining. The MVISE has successfully passed a week-long leak test and is now undergoing active biology tests. The MVISE prototype will be prepared for radiation tests, with three identical units being tested for varying radiation levels and culture compositions at the NASA Space Radiation Laboratory in November 2024. The integrated sensor approach proposed in this work will enable the accurate mapping of the BioSentinel/LEIA optical flight data to six sensor parameters on the ground unit for better science data return and will enable the first effort to evaluate classical biochemical sensor measurements by comparing and contrasting their responses.

Chinmayee Govinda Raj↗

3D Printed TiO 2 Negative Electrodes for Sodium-Ion and Lithium-ion Batteries using Vat Photopolymerization

Additive manufacturing, also called 3D printing, represents a unique approach to develop three dimensional shape-conformable batteries with enhanced electrodes, specific surface area, improved ion diffusion, and power. For the first time, the formulation of a composite photocurable resin loaded with battery electrochemically active components was designed to feed a vat photopolymerization (VPP) 3D printer. In direct alignment with NASA’s Artemis mission goals to develop sustainable lunar energy storage infrastructure necessary to support long-term human operations, TiO 2 was here selected as an active material for the negative electrode for sodium-ion and lithium-ion batteries due to its abundance on the lunar surface. The TiO 2 loading in the composite photocurable resin and in the resulting VPP-printed negative electrode was increased as high as possible to enhance the electrochemical performance, while simultaneously ensuring the printability and acceptable mechanical strength for sample handling. The effect of thermal post-processing on the electrical, electrochemical and mechanical performance is reported. Finally, a configurational study is implemented to identify the impact of two different electrode designs (cubic and gyroid lattice unit cells) on the electrochemical performance. This work addresses the difficulties related to the introduction of solid particles within a VPP photocurable resin and the need for a compromise between the electrochemical performances and printability to obtain fully functional VPP-printed electrodes.

sodium-ion battery↗

SIBatt-3D: In-Space/On-Surface 3D Printing of Sodium Ion Batteries from ISRU Materials

Constructed more than 20 years ago, the International Space Station’s primary power system originally used nickel-hydrogen batteries with a lifetime of 6.5 years, until NASA began the process of replacing them in 2016 with lithium-ion batteries with a lifetime of 10 years. The demanding and costly process was accomplished after four flights of the Japanese H-II Transfer Vehicle cargo spacecraft (with a cost of about $10,000 per pound of payload), and 13 different astronauts conducting 14 spacewalks. Besides utilization in the ISS, rechargeable batteries are present in many space applications: they are installed in exploration robots, life support systems and in portable communication devices, to mention some. In this context, this project is focused on the in-space manufacturing of shape-conformable batteries using in-situ resources, and aims to address the NASA’s gaps related to the development of next generation of energy storage devices (TX03), as well as in-space manufacturing and in-situ resource utilization (TX07). The proposed work also tackles the HEOMD’s objectives targeting the in-space additive manufacturing (AM) from Lunar/Martian materials (regolith as AM feedstock) to reinvigorate America’s Human Space Exploration Program (SPD-1). This project is in direct alignment with the STMD’s objectives to demonstrate in-space autonomous manufacturing and assembly of complete systems by 2030, and to enable humans to live and explore in space and on planetary surfaces by 2040 thanks to in-space habitation, infrastructure development and in-situ resource utilization (ST1 and ST5). Manufacturing of shape conformable batteries directly in-space and using in-situ resources would also contribute to reducing the payload weight and volume (TX12) for future missions, thus reducing risk for long term Mars missions where rapid resupply is logistically infeasible. Nowadays, commercial batteries consist of stacked two-dimensional (2D) sheets, which are only manufactured in restricted geometries (cylindrical and coin cell). Evolving from conventional 2D, complex 3D battery architectures have been proven to increase the electrochemical active surface area and ion diffusion path, leading to improved areal energy density and power performance. This tendency was illustrated in our recent in-depth modeling studies by simulating a classical Ragone plot exhibiting the energy-power relationship. Our team demonstrated through modeling that a complex gyroidal 3D printed battery architecture exhibits significantly improved power performances (>150% at the current density of 6C; full discharge in 10 minutes) in comparison to a traditional 3D printed planar geometry. Motivated by these results and as the fabrication of intricate 3D battery design is only possible experimentally thanks to the geometric freedom offered by additive manufacturing (AM), our team has already initiated leveraging thermoplastic material extrusion at the laboratory scale. While 3D printing of batteries is relatively recent (2013), it has witnessed a growing interest during the last recent years, as next-generation shape-conformable 3D batteries can be co-designed with the system. Consequently, dead-volume and mass brought from Earth are minimized, in addition to improved battery performance, in alignment with the aforementioned NASA’s objectives. Further, while this project is specifically dedicated to batteries, it lends itself towards the maturation of in-space manufacturing via 3D printing using in-situ resources, stated in HEOMD and STMD goals.

In-Space Manufacturing↗

Carbon Nanostructures in Biological Sensors for Space and Terrestrial Applications

Biosensing devices comprised of carbon nanotubes and nanofibers have been developed for astronaut crew point-of-care. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using carbon nanotube and carbon nanofiber electrodes for biomedical applications. First, a 3x3 electrode device, with each electrode containing 40,000 carbon nanofiber nanoelectrodes was fabricated on silicon using traditional microfabrication processing. The device was demonstrated as a multiplexed immunosensor for simultaneous, label-free detection of cardiac troponin-I, C-reactive protein and myoglobin. Antibodies specific to cardiac troponin-I, C-reactive protein and myoglobin were covalently bound to the CNF surface and were characterized using electrochemical impedance spectroscopy and differential pulse voltammetry. Each step of the modification process resulted in changes in resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific cardiac protein. The real-time label free detection of the three cardiac markers from pure components and mixtures was demonstrated with high sensitivity, down to 0.2 ng/mL, and good selectivity. Detection in human blood serum did not present false positives from non-specific protein adsorption. More recently, this detection scheme has been applied to inkjet printed carbon nanotube electrodes on Kapton and paper. Printed devices have several unique advantages including simple and inexpensive fabrication. The results demonstrate that these sensors can serve a miniaturized, low cost device for detection of proteins in complex mixtures making this platform a good candidate for early stage diagnosis of myocardial infarction. Future inkjet printed devices can be fabricated have the added advantage in their suitability to be manufactured in an in-space, microgravity environment.

carbon nanotubes↗

Carbon Nanomaterials for Biosensing Applications

Biosensing devices comprised of carbon nanotubes and nanofibers have been developed for astronaut crew point-of-care. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using carbon nanotube and carbon nanofiber electrodes for biomedical applications. First, a 3x3 electrode device, with each electrode containing 40,000 carbon nanofiber nanoelectrodes was fabricated on silicon using traditional microfabrication processing. The device was demonstrated as a multiplexed immunosensor for simultaneous, label-free detection of cardiac troponin-I, C-reactive protein and myoglobin. Antibodies specific to cardiac troponin-I, C-reactive protein and myoglobin were covalently bound to the CNF surface and were characterized using electrochemical impedance spectroscopy and differential pulse voltammetry. Each step of the modification process resulted in changes in resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific cardiac protein. The real-time label free detection of the three cardiac markers from pure components and mixtures was demonstrated with high sensitivity, down to 0.2 ng/mL, and good selectivity. Detection in human blood serum did not present false positives from non-specific protein adsorption. More recently, this detection scheme has been applied to inkjet printed carbon nanotube electrodes on Kapton and paper. Printed devices have several unique advantages including simple and inexpensive fabrication. The results demonstrate that these sensors can serve a miniaturized, low cost device for detection of proteins in complex mixtures making this platform a good candidate for early stage diagnosis of myocardial infarction. Future inkjet printed devices can be fabricated have the added advantage in their suitability to be manufactured in an in-space, microgravity environment.

carbon nanotubes↗