Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical test and measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Qualification tests and electrical measurements: Practice and problems

As part of the Flat-Plate Solar Array Project, 138 different module designs were subjected to qualification tests. Electrical measurements were subjected on well over a thousand modules representing more than 150 designs. From this experience, conclusions are drawn regarding results and problems, with discussion of the need for change or improvement. The qualification test sequence incuded application of environmental and electrical stresses to the module. With few exceptions, the tests have revealed defects necessitation of environmental and electrical stresses to the module. With few exceptions, the tests have revealed defects necessitating module design or process changes. However, the continued need for these tests may be questioned on the basis of technical and logistical factors. Technically, the current test sequence does not cover all design characteristics, does not include all field conditions and is not known to represent the desired 30-year module life. Logistically, the tests are time-consuming and costly, and there is a lack of, fully qualified independent test organizations. Alternatives to the current test program include simplification based on design specification and site environment, and/or the use of warranties or other commercial practices.

Smokler, M. I.↗

Qualification testing and electrical measurement experience: A manufacturer's view

ARCO Solar's experiences as a participant in an industry-utility-government environmental qualification team examining photovoltaic devices are discussed. Included is an assessment of the applicability, completeness and appropriateness of the testing procedures and of the acceptance criteria for megawatt-sized procurements for utilities. Like the stand-alone users, the utility industry is interested in obtaining low costs, but additional concerns exist related to reliability and durability, safety, grounding and overall system criteria including performance prediction (related to output power acceptance testing), power quality and dispatchability. For purposes of this first major purchase of photovoltaic modules and panels by the utility industry, there was a carry-over of the JPL specifications. The need exists for futher development, assessement, and selection of qualification and testing standards and evaluation criteria specifically addressing these additional concerns for utility-connected PV power-plant applications.

Arnett, J. C.↗

A Step Towards Electric Propulsion Testing Standards: Pressure Measurements and Effective Pumping Speeds

The electric propulsion community has been implored to establish and implement a set of universally applicable test standards during the research, development, and qualification of electric propulsion systems. Existing practices are fallible and result in testing variations which leads to suspicious results, large margins in application, or aversion to mission infusion. Performance measurements and life testing under appropriate conditions can be costly and lengthy. Measurement practices must be consistent, accurate, and repeatable. Additionally, the measurements must be universally transportable across facilities throughout the development, qualification, spacecraft integration and on-orbit performance. A preliminary step to progress towards universally applicable testing standards is outlined for facility pressure measurements and effective pumping speed calculations. The standard has been applied to multiple facilities at the NASA Glenn Research Center. Test results and analyses of universality of measurements are presented herein.

Dankanich, John W.↗

Electrical Characterization of Hughes HCMP 1852D and RCA CDP1852D 8-bit, CMOS, I/O Ports

Twenty-five Hughes HCMP 1852D and 25 RCA CDP1852D 8-bit, CMOS, I/O port microcircuits underwent electrical characterization tests. All electrical measurements were performed on a Tektronix S-3260 Test System. Before electrical testing, the devices were subjected to a 168-hour burn-in at 125 C with the inputs biased at 10V. Four of the Hughes parts became inoperable during testing. They exhibited functional failures and out-of-range parametric measurements after a few runs of the test program.

Stokes, R. L.↗

Note: Inhibiting bottleneck corrosion in electrical calcium tests for ultra-barrier measurements

A major failure mechanism is identified in electrical calcium corrosion tests for quality assessment of high-end application moisture barriers. Accelerated calcium corrosion is found at the calcium/electrode junction, leading to an electrical bottleneck. This causes test failure not related to overall calcium loss. The likely cause is a difference in electrochemical potential between the aluminum electrodes and the calcium sensor, resulting in a corrosion element. As a solution, a thin, full-area copper layer is introduced below the calcium, shifting the corrosion element to the calcium/copper junction and inhibiting bottleneck degradation. Using the copper layer improves the level of sensitivity for the water vapor transmission rate (WVTR) by over one order of magnitude. Thin-film encapsulated samples with 20 nm of atomic layer deposited alumina barriers this way exhibit WVTRs of 6 × 10{sup −5} g(H{sub 2}O)/m{sup 2}/d at 38 °C, 90% relative humidity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A test technique for measuring lightning-induced voltages on aircraft electrical circuits

The development of a test technique used for the measurement of lightning-induced voltages in the electrical circuits of a complete aircraft is described. The resultant technique utilizes a portable device known as a transient analyzer capable of generating unidirectional current impulses similar to lightning current surges, but at a lower current level. A linear relationship between the magnitude of lightning current and the magnitude of induced voltage permitted the scaling up of measured induced values to full threat levels. The test technique was found to be practical when used on a complete aircraft.

Walko, L. C.↗

Investigation of reliability attributes and accelerated stress factors on terrestrial solar cells

The results of accelerated stress testing of four different types of silicon terrestrial solar cells are discussed. The accelerated stress tests used included bias-temperature tests, bias-temperature-humidity tests, thermal cycle and thermal shock tests, and power cycle tests. Characterization of the cells was performed before stress testing and at periodic down-times, using electrical measurement, visual inspection, and metal adherence pull tests. Electrical parameters measured included short-circuit current, open circuit voltage, and output power, voltage, and current at the maximum power point. Incorporated in the report are the distributions of the prestress electrical data for all cell types. Data were also obtained on cell series and shunt resistance.

Prince, J. L.↗

Mechanical behavior and electrical conductivity of La1-xCaxCoO3 (x = 0, 0.2, 0.4, 0.55) perovskites

This paper compares the important mechanical properties and the electrical conductivities from room temperature to 800oC of four LaCoO3 based cobaltite compositions with 0, 20, 40 and 55% Ca2+ ions substituted on the A site of the perovskite structure respectively. Ca2+ doped lanthanum cobaltite materials are strong candidates for use as cathodes in lower temperature solid oxide fuel cells operating at or below 800oC. Among these four cobaltite compositions, two (LaCoO3 and La0.8Ca0.2CoO3) were found to be phase pure materials, whereas the remaining two compositions (La0.6Ca0.4CoO3 and La0.45Ca0.55CoO3) contained precipitation of secondary phases such as CaO and Co3O4. The mechanical properties of the four compositions, in terms of Young s modulus, four-point bending strength and fracture toughness measurements, were measured at both room temperature and 800oC. At room temperature, doping with Ca2+ was found to substantially increase the mechanical properties of the cobaltites, whereas at 800oC the pure LaCoO3 composition exhibited higher modulus and strength values than La0.8Ca0.2CoO3. All of the four compositions exhibited ferroelastic behavior, as shown by the hysteresis loops generated during uniaxial load-unload compression tests. Electrical conductivity measurements showed the La0.8Ca0.2CoO3 composition to have the highest conductivity among the four compositions.

30 DIRECT ENERGY CONVERSION↗

The Effects of Electrostatic Discharge Phenomena on Detonator Response: A Framework for Evaluating Parameters Relevant to Quantification of Margins and Uncertainties

Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and Pantex are collaborating on a Nuclear Safety Research & Development (NSR&D) project to develop a common Quantification of Margins and Uncertainties (QMU) framework for explosive safety analysis. An analysis of electrostatic discharge (ESD) data serves as an initial test case for methodology development. This analysis examines measurements of electrical characteristics of production environments, tests designed to measure ESD response of detonators, and information on interactions between variables drawn from expert knowledge and physics models.

42 ENGINEERING↗

Development of a spectroscopic diagnostic tool for electric field measurements in IShTAR (Ion cyclotron Sheath Test ARrangement)

IShTAR, Ion cyclotron Sheath Test ARrangement, is a linear device dedicated to the investigation of the edge plasma–ICRF (Ion Cyclotron Range of Frequencies) antenna interactions in tokamak edge-like conditions and serves as a platform for a diagnostic development for measuring the electric fields in the vicinity of ICRF antennas. We present here our progress in the development of an optical emission spectroscopy method for measuring the electric fields which concentrates on the changes in the helium spectral line profiles introduced by the external electrical field, i.e., the Stark effect. To be able to fully control the operating parameters, at the first stage of the study, the measurements are conducted on a planar electrode installed in the centre of the plasma column in IShTAR’s helicon plasma source. At the second stage, the measurements are performed in the vicinity of IShTAR’s ICRF antenna.

Kostic, Ana↗

Dc pin-to-pin testing of integrated circuits

External pin-to-pin nondestructive testing procedure measures the electrical characteristics of each element in an integrated circuit. The procedure involves choosing specific pairs of pins and applying appropriate test voltages to them.

Thomas, E. F.↗

Characterization testing of MEASAT GaAs/Ge solar cell assemblies

The first commercial communications satellite with gallium-arsenide on germanium (GaAs/Ge) solar arrays is scheduled for launch in December 1995. The spacecraft, named MEASAT, was built by hughes Space and Telecommunications company for Binariang Satellite Systems of Malaysia. The solar cell assemblies consisted of large area GaAs/Ge cells supplied by Spectrolab Inc. with infrared reflecting (IRR) coverglass supplied by Pilkington Space Technology. A comprehensive characterization program was performed on the GaAs/Ge solar cell assemblies used on the MEASAT array. This program served two functions; first to establish the database needed to accurately predict on-orbit performance under a variety of conditions; and second, to demonstrate the ability of the solar cell assemblies to withstand all mission environments while still providing the required power at end-of-life. characterization testing included measurement of electrical performance parameters as a function of radiation exposure, temperature, and angle of incident light; reverse bias stability; optical and thermal properties; mechanical strength tests, panel fabrication, humidity and thermal cycling environmental tests. The results provided a complete database enabling the design of the MEASAT solar array, and demonstrated that the GaAs/Ge cells meet the spacecraft requirements at end-of-life.

Brown, Mike R.↗

Characterization testing of MEASAT GaAs/Ge solar cell assemblies

The first commercial communications satellite with gallium-arsenide on germanium (GaAs/Ge) solar arrays is scheduled for launch in December 1995. The spacecraft, named MEASAT, was built by Hughes Space and Communications Company. The solar cell assemblies consisted of large area GaAs/Ge cells supplied by Spectrolab Inc. with infrared reflecting (IRR) coverglass supplied by Pilkington Space Technology. A comprehensive characterization program was performed on the GaAs/Ge solar cell assemblies used on the MEASAT array. This program served two functions; first to establish the database needed to accurately predict on-orbit performance under a variety of conditions; and second, to demonstrate the ability of the solar cell assemblies to withstand all mission environments while still providing the required power at end-of-life. Characterization testing included measurement of electrical performance parameters as a function of radiation exposure, temperature, and angle of incident light; reverse bias stability; optical and thermal properties; mechanical strength tests, panel fabrication, humidity and thermal cycling environmental tests. The results provided a complete database enabling the design of the MEASAT solar array, and demonstrated that the GaAs/Ge cells meet the spacecraft requirements at end-of-life.

Brown, Mike R.↗

Detection of gas leakage

A method of detecting leaks and measuring volumes as well as an apparatus, the Power-free Pump Module (PPM), that is a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement, where the invention is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr), perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.

47 OTHER INSTRUMENTATION↗

Detection of gas leakage

A method of detecting leaks and measuring volumes as well as a device, the Power-free Pump Module (PPM), provides a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement. The PPM is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr) using a venturi pump, perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.

47 OTHER INSTRUMENTATION↗

High Strength, Utilizable Ductility and Electrical Conductivity in Cold Rolled Sheets of Cu-Cr-Zr-Ti Alloy

The microstructure and properties of Cu-0.5Cr-0.03Zr-0.04Ti (wt.%) alloy subjected to cold rolling and aging were investigated using hardness and electrical conductivity measurement, tensile testing, and transmission electron microscopy. Plates subjected to 85% reduction in thickness showed significant improvement in the strength compared to solution treated and aged condition. By proper selection of aging temperature, ductility could be significantly improved without reduction in the strength. Aging of the cold rolled sheet at 420 °C for 1 h yielded an ultimate tensile strength and yield strength of 540 and 460 MPa, respectively. On the other hand, total and uniform elongation was 16 and 12%, respectively, with an electrical conductivity of 65 %IACS. The combination of properties achieved after cold rolling and aging is attributed to the higher dislocation density, ultrafine grains and nano-sized chromium precipitates.

36 MATERIALS SCIENCE↗