Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Frequency dependent electrical measurements of amorphous GeSbSe chalcogenide thin films

A commercial bulk chalcogenide glass (Ge28Sb12Se60) was used as a source to fabricate amorphous thin films via thermal evaporation technique. At low frequencies (1 MHz) impedance spectroscopy was performed to measure electrical properties. To measure ac conductivity at microwave frequencies, a split resonance cavity technique was applied for which a model based on parallel arrangement of substrate and film capacitors was developed. This model was used to extract tan8 and ac conductivity of the films. Microwave ac conductivity was correlated with the extrapolated low frequency conductivity data confirming applicability of the universal law commonly observed in amorphous semiconductors.

36 MATERIALS SCIENCE↗

Rheo-electric measurements of carbon black suspensions containing polyvinylidene difluoride in N -methyl-2-pyrrolidone

Lithium-ion battery cathode slurries have a microstructure that depends sensitively on how they are processed due to carbon black's (CB) evolving structure when subjected coating flows. While polyvinylidene difluoride (PVDF), one of the main components of the cathode slurry, plays an important role in modifying the structure and rheology of CB, a quantitative understanding is lacking. In this work, we explore the role of PVDF in determining the structural evolution of Super C65 CB in N-methyl-2-pyrrolidinone (NMP) with rheo-electric measurements. We find that PVDF enhances the viscosity of NMP resulting in a more extensive structural erosion of CB agglomerates with increasing polymer concentration and molecular weight. We also show that the relative viscosity of all suspensions can be collapsed by the fluid Mason number (Mnf), which compares the hydrodynamic forces imposed by the medium to cohesive forces holding CB agglomerates together. Using simultaneous rheo-electric measurements, we find at high Mnf, the dielectric strength (Δε) scales with Mnf, and the power-law scaling can be quantitatively predicted by considering the self-similar break up of CB agglomerates. The collapse of the relative viscosity and scaling of Δε both suggest that PVDF increases the hydrodynamic force of the suspending medium without directly changing the CB agglomerate structure. These findings are valuable for optimizing the rheology of lithium ion battery cathode slurries. We also anticipate that these findings can be extended to understand the microstructure of similar systems under flow.

Mechanics↗

Sub-Kelvin magnetic and electrical measurements in a diamond anvil cell with in-situ tunability

We discuss techniques for performing continuous measurements across a wide range of pressure-field-temperature phase space, combining the milli-Kelvin temperatures of a helium dilution refrigerator with that of the giga-Pascal pressures of a diamond anvil cell and the Tesla magnetic fields of a superconducting magnet. With a view towards minimizing remnant magnetic fields and background magnetic susceptibility, we then characterize high-strength superalloy materials for the pressure cell assembly, which allows high fidelity measurements of low-field phenomena such as superconductivity below 100 mK at pressures above 10 GPa. In situ tunability and measurement of the pressure permit experiments over a wide range of pressure, while at the same time making possible precise steps across abrupt phase transitions such as that from insulator to metal.

36 MATERIALS SCIENCE↗

Towards nanoscale electrical measurements in liquid by advanced KPFM techniques: a review

Fundamental mechanisms of energy storage, corrosion, sensing, and multiple biological functionalities are directly coupled to electrical processes and ionic dynamics at solid–liquid interfaces. In many cases, these processes are spatially inhomogeneous taking place at grain boundaries, step edges, point defects, ion channels, etc and possess complex time and voltage dependent dynamics. This necessitates time-resolved and real-space probing of these phenomena. In this review, we discuss the applications of force-sensitive voltage modulated scanning probe microscopy (SPM) for probing electrical phenomena at solid–liquid interfaces. We first describe the working principles behind electrostatic and Kelvin probe force microscopies (EFM & KPFM) at the gas–solid interface, review the state of the art in advanced KPFM methods and developments to (i) overcome limitations of classical KPFM, (ii) expand the information accessible from KPFM, and (iii) extend KPFM operation to liquid environments. We briefly discuss the theoretical framework of electrical double layer (EDL) forces and dynamics, the implications and breakdown of classical EDL models for highly charged interfaces or under high ion concentrations, and describe recent modifications of the classical EDL theory relevant for understanding nanoscale electrical measurements at the solid–liquid interface. We further review the latest achievements in mapping surface charge, dielectric constants, and electrodynamic and electrochemical processes in liquids. Lastly, we outline the key challenges and opportunities that exist in the field of nanoscale electrical measurements in liquid as well as providing a roadmap for the future development of liquid KPFM.

36 MATERIALS SCIENCE↗

Electric field induced Lyman-α emission of a hydrogen beam for electric field measurements

Electric field induced Lyman-α emission is a new way of measuring weak electric fields in vacuum and in a plasma. It is based on the emission of Lyman-α radiation (121.6 nm) by a low-energy metastable H atom beam due to Stark-quenching of the 2s level induced by the field. In this paper, we describe the technique in detail. Test measurements have been performed in vacuum between two plates polarized at a controlled voltage. The intensity of emitted radiation, proportional to the square of the field modulus, has been recorded by a lock-in technique, which gives an excellent signal to noise ratio. These measurements provide an in situ calibration that can be used to obtain the absolute value of the electric field. A diagnostic of this type can help to address a long standing challenge in plasma physics, namely, the problem of measuring electric fields without disturbing the equilibrium of the system that is being studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contact-independent electrical conductance measurement

Electrical conductance measurement system including a one-dimensional semiconducting channel, with electrical conductance sensitive to electrostatic fluctuations, in a circuit for measuring channel electrical current. An electrically-conductive element is disposed at a location at which the element is capacitively coupled to the channel; a midpoint of the element aligned with about a midpoint of the channel, and connected to first and second electrically-conductive contact pads that are together in a circuit connected to apply a changing voltage across the element. The electrically-conductive contact pads are laterally spaced from the midpoint of the element by a distance of at least about three times a screening length of the element, given in SI units as (K.di-elect cons..sub.0/e.sup.2D(E.sub.F)).sup.1/2, where K is the static dielectric constant, .di-elect cons..sub.0 is the permittivity of free space, e is electron charge, and D(E.sub.F) is the density of states at the Fermi energy for the element.

42 ENGINEERING↗

Note: Novel diamond anvil cell for electrical measurements using boron-doped metallic diamond electrodes

A novel diamond anvil cell suitable for electrical transport measurements under high pressure has been developed. A boron-doped metallic diamond film was deposited as an electrode on a nano-polycrystalline diamond anvil using a microwave plasma-assisted chemical vapor deposition technique combined with electron beam lithography. The maximum pressure that can be achieved by this assembly is above 30 GPa. We report electrical transport measurements of Pb up to 8 GPa. The boron-doped metallic diamond electrodes showed no signs of degradation after repeated compression.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inversion of downhole electrical measurements for proppant mapping using very fast simulated annealing

Proppant mapping is critical for optimizing fracture treatment design and improving wells’ productivity. An electrode-based resistivity tool concept was developed earlier for proppant mapping in cased-hole wells. An array of insulating gaps is installed and cemented in place as a permanent part of the casing string. The electrical measurements are performed by imposing a voltage across each insulating gap, one at a time, before and after hydraulic fracture operations. The voltages across other insulating gaps near the transmitter gap are recorded. The method relies on direct excitation of the casing, which is expected to overcome the severe limitations of induction tools in cased-hole wells. A forward model based on a finite volume method has been developed to simulate the tool’s response to one or multiple fractures. To enable the implementation of such a practical system in multistage fractured horizontal wells, a fast and robust inversion approach is required. To that end, we have developed a divide-and-conquer approach based on a global optimization algorithm very fast simulated annealing (VFSA). Specifically, the original inverse problem is divided into subproblems and each subproblem can be solved separately using VFSA. The results indicate that our approach can invert the data and output widths and radii of multiple fractures without requiring a large number of forward simulations. The robustness of the inverse solver is also tested by adding Gaussian noise to the synthetic data. We tested example cases that demonstrate that when up to 5% noise is introduced, VFSA still provides very accurate inversion results with moderate uncertainties. Inversion results with some more realistic conditions, e.g., tilted fractures, complex fractures, and so on, are also presented.

Geochemistry & Geophysics↗

Amorphous to fcc-polycrystal transition in Ge{sub 2}Sb{sub 2}Te{sub 5} thin films studied by electrical measurements: Data analysis and comparison with direct microscopy observations

We experimentally investigate the isothermal amorphous-to-fcc polycrystalline phase transition process in amorphous Ge{sub 2}Sb{sub 2}Te{sub 5} thin films prepared by sputtering. The amorphous layers were either as deposited or formed by Ar{sup +} ion implantation after crystallization at 300 deg. C. The kinetics of the amorphous-to-polycrystal transition are analyzed through electrical measurements, in which the Johnson-Mehl-Avrami-Kolmogorov theory is employed. The procedure to extract the kinetics of the phase transition from conductivity versus time data is carefully discussed and compared to data of cross-sectional transmission electron microscopy images versus anneal time. By following this proposed procedure, the nucleation and growth parameters, and the activation energies have been determined. Results indicate that the process of isothermal crystallization in Ge{sub 2}Sb{sub 2}Te{sub 5} takes place in two stages, in which the Avrami exponent changes in the range from 3 to 1. These results are understood in terms of modifications in the kinetics of the phase transition.

36 MATERIALS SCIENCE↗

Lyman-{alpha} radiation of a metastable hydrogen beam to measure electric fields

The interaction between a metastable H(2s) atomic hydrogen beam and an external electric field leads to the emission of the Lyman-{alpha} line. It originates in the Stark mixing of the near-degenerate 2s{sub 1/2} and 2p{sub 1/2} levels separated by the Lamb shift. The quenched radiation proportional to the square of the electric field amplitude is recovered in vacuum by using such an atomic probe beam. We observe the strong enhancement of the signal when the field is oscillating at the Lamb shift frequency. This technique is applied in a plasma, offering an alternative way to measure weak electric fields by direct and non-intrusive means.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lyman-α radiation of a probing metastable hydrogen beam to measure electric fields in diluted fluids and plasmas

The interaction between a metastable H(2s) atomic hydrogen beam and an external electric field leads to the emission of the Lyman-α line. It originates in the Stark mixing of the near-degenerate 2s{sub 1/2} and 2p{sub 1/2} levels separated by the Lamb shift. The quenched radiation proportional to the square of the electric field amplitude is recovered in vacuum by using such an atomic probe beam. For larger electric field, saturation is observed and related to the beam finite transit time. We also observe the strong enhancement of the signal when the field is oscillating at the Lamb shift frequency. This technique is applied in a plasma, offering an alternative way to measure weak electric fields by direct and non-intrusive means.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analyzing degradation effects of organic light-emitting diodes via transient optical and electrical measurements

Although the long-term stability of organic light-emitting diodes (OLEDs) under electrical operation made significant progress in recent years, the fundamental underlying mechanisms of the efficiency decrease during operation are not well understood. Hence, we present a comprehensive degradation study of an OLED structure comprising the well-known green phosphorescent emitter Ir(ppy){sub 3}. We use transient methods to analyze both electrical and optical changes during an accelerated aging protocol. Combining the results of displacement current measurements with time-resolved investigation of the excited states lifetimes of the emitter allows for a correlation of electrical (e.g., increase of the driving voltage due to trap formation) and optical (e.g., decrease of light-output) changes induced by degradation. Therewith, it is possible to identify two mechanisms resulting in the drop of the luminance: a decrease of the radiative quantum efficiency of the emitting system due to triplet-polaron-quenching at trapped charge carriers and a modified charge carrier injection and transport, as well as trap-assisted non-radiative recombination resulting in a deterioration of the charge carrier balance of the device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrical Measurement and Verification of Energy in DC Buildings

Today's selection of DC buildings features a diverse set of electrical topologies and turnkey solutions, and each has specific design trade-offs and optimizations. Designers desperately need standardized metrics and procedures for measurement and verification (M&V) to analyze and compare the advantages of each DC solution to traditional AC building networks. This work develops the Measurement-Informed Modeling (MIM) method, which can be used to determine full-building efficiency and energy savings. The MIM M&V procedure develops a building model, and refines the model with metered data. This work demonstrates the MIM method by measuring the full-building efficiency of two DC buildings operated by the Institute of Building Research in Shenzhen, China. The MIM procedure can ultimately be used to compare and improve the efficiency of various DC topologies.

buildings↗

Theory and Methods of Photovoltaic Material Characterization: Optical and Electrical Measurement Techniques

This book provides an extensive review of the theory of transport and recombination properties in semiconductors. The emphasis is placed on electrical and optical techniques. There is a presentation of the latest experimental and theoretical techniques used to analyze minority-carrier lifetime. The relevant hardware and instrumentation are described. The newest techniques of lifetime mapping are presented. The issues are discussed relating to effects that mask carrier lifetime in certain device structures. The discrepancy between photoconductive and photoluminescence measurement results are analyzed.

14 SOLAR ENERGY↗