Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “effusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Symptomatic Pericardial Effusion After Chemoradiation Therapy in Esophageal Cancer Patients

Purpose: We investigated clinical and treatment-related factors as predictors of symptomatic pericardial effusion in esophageal cancer patients after concurrent chemoradiation therapy. Methods and Materials: We reviewed 214 consecutive primary esophageal cancer patients treated with concurrent chemoradiation therapy between 2001 and 2010 in our institute. Pericardial effusion was detected on follow-up computed tomography. Symptomatic effusion was defined as effusion ≥grade 3 according to Common Terminology Criteria for Adverse Events v4.0 criteria. Percent volume irradiated with 5 to 65 Gy (V5-V65) and mean dose to the pericardium were evaluated employing dose-volume histograms. To evaluate dosimetry for patients treated with two-dimensional planning in the earlier period (2001-2005), computed tomography data at diagnosis were transferred to a treatment planning system to reconstruct three-dimensional plans without modification. Optimal dosimetric thresholds for symptomatic pericardial effusion were calculated by receiver operating characteristic curves. Associating clinical and treatment-related risk factors for symptomatic pericardial effusion were detected by univariate and multivariate analyses. Results: The median follow-up was 29 (range, 6-121) months for eligible 167 patients. Symptomatic pericardial effusion was observed in 14 (8.4%) patients. Dosimetric analyses revealed average values of V30 to V45 for the pericardium and mean pericardial doses were significantly higher in patients with symptomatic pericardial effusion than in those with asymptomatic pericardial effusion (P<.05). Pericardial V5 to V55 and mean pericardial doses were significantly higher in patients with symptomatic pericardial effusion than in those without pericardial effusion (P<.001). Mean pericardial doses of 36.5 Gy and V45 of 58% were selected as optimal cutoff values for predicting symptomatic pericardial effusion. Multivariate analysis identified mean pericardial dose as the strongest risk factor for symptomatic pericardial effusion. Conclusions: Dose-volume thresholds for the pericardium facilitate predicting symptomatic pericardial effusion. Mean pericardial dose was selected based not only on the optimal dose-volume threshold but also on the most significant risk factor for symptomatic pericardial effusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effusion rate, length, and area relationships for some lava flows on Hawaii and Mount Etna with planetary implications

A model for the radiative cooling of thermally well mixed lava flows is presented and the relationship between effusion rate and length and area is analyzed. If radiative cooling is the prime mode of heat loss for a lava flow, one should expect to see a stronger correlation between the effusion rate and the plan area of the flow, than between effusion rate and just flow length. Different flows on a single volcano with differing initial temperatures, volatile content, and gross compositions should yield different areas for a given effusion rate. Likewise, a range of slopes for the relationship between effusion rate and flow area should result from comparisons between different volcanoes. As a test of these ideas, available data on the effusion rates, lengths, and areas of Hawaiian and Etnean flow is studied. It was found that: (1) the effusion rate/area correlation was statistically more significant than the correlation between effusion rate and length for four out of the five eruption episodes which met the necessary criteria of more than three individual flows with area, length, and effusion rate independently measured; (2) that there exists a minimum length and area for a given effusion rate, reflecting competition between overall characteristic proportionality between effusion rate and flow length, width, and area.

Pieri, D.↗

Dose-Volume Histogram Parameters and Clinical Factors Associated With Pleural Effusion After Chemoradiotherapy in Esophageal Cancer Patients

Purpose: To investigate the dose-volume histogram parameters and clinical factors as predictors of pleural effusion in esophageal cancer patients treated with concurrent chemoradiotherapy (CRT). Methods and Materials: Forty-three esophageal cancer patients treated with definitive CRT from January 2001 to March 2007 were reviewed retrospectively on the basis of the following criteria: pathologically confirmed esophageal cancer, available computed tomography scan for treatment planning, 6-month follow-up after CRT, and radiation dose {>=}50 Gy. Exclusion criteria were lung metastasis, malignant pleural effusion, and surgery. Mean heart dose, mean total lung dose, and percentages of heart or total lung volume receiving {>=}10-60 Gy (Heart-V{sub 10} to V{sub 60} and Lung-V{sub 10} to V{sub 60}, respectively) were analyzed in relation to pleural effusion. Results: The median follow-up time was 26.9 months (range, 6.7-70.2) after CRT. Of the 43 patients, 15 (35%) developed pleural effusion. By univariate analysis, mean heart dose, Heart-V{sub 10} to V{sub 60}, and Lung-V{sub 50} to V{sub 60} were significantly associated with pleural effusion. Poor performance status, primary tumor of the distal esophagus, and age {>=}65 years were significantly related with pleural effusion. Multivariate analysis identified Heart-V{sub 50} as the strongest predictive factor for pleural effusion (p = 0.01). Patients with Heart-V{sub 50} <20%, 20%{<=} Heart-V{sub 50} <40%, and Heart-V{sub 50} {>=}40% had 6%, 44%, and 64% of pleural effusion, respectively (p < 0.01). Conclusion: Heart-V{sub 50} is a useful parameter for assessing the risk of pleural effusion and should be reduced to avoid pleural effusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermal Effusivity Tomography from Pulsed Thermal Imaging

The software program generates 3D volume distribution of thermal effusivity within a test material from one—sided pulsed thermal imaging data. Thsi is the first software capable of accurate, fast and automated thermal tomographic imaging of inhomogeneoirs materials to produce 3D images similar to those obtained from 3D X—ray CT (all previous thepnal—imaging software can only produce 20 results) . Because thermal effusivity is an Intrisic material property that is related to material constituent, density, conductivity, etc., quantitative imaging of eftusivity allowed direct visualization of material’s internal constituent/structure and damage distributions, thereby potentially leading to quantitative prediction of other material properties such as strength. I can be therefre be used for 3D imaging of material structure in fundamental material studies, nondestructive characterization of defects/flaws in structural engineering components, health monitoring of material damage and degradation during service, and medical imaging and diagnostics. This technology is one—sided, non contact and sensitive to material’s thermal property and discontinuity. One major advantage of this tomographic technology over x-ray CT and ultrasounds is its natural efficiency for 3D imaging of the volume under a large surface area. This software is implemented with a method for thermal computed tomography of thermal effusivity from one—sided pulsed thermal imaging (or thermography) data. The method is based on several solutions of the governing heat transfer equation under pulsed thermography test condition. In particular, it consists of three components. 1) It utilized the thermal effusivity as the imaging parameter to construct the 3D image. 2) It established a relationship between the space (depth) and the time, because thermography data are in the time domain. 3) It incorporated a deconvolution algorithm to solve the depth porfile of the material thermal effusivity from the measured (temporal) surface temperature data. The predicted effusivity is a direct function of depth, not an average or convolved parameter, so it is an accurate (and more sensitive) representation of local property along depth.

Sun, Jiangang↗

HGP component with effusion cooling element having coolant swirling chamber

An effusion cooling element for the surface of a hot gas path (HGP) component is disclosed. The effusion cooling element includes a coolant swirling chamber embedded within the body of the HGP component. A coolant delivery passage is in the body and configured to deliver a coolant to the coolant swirling chamber. The coolant swirling chamber imparts a centrifugal force to the coolant. An effusion opening is in the HGP surface and in fluid communication with the coolant swirling chamber, the effusion opening having a smaller width than the coolant swirling chamber. The coolant exits the effusion opening over substantially all of 360° about the effusion opening, creating a coolant film on the HGP surface.

Berry, Jonathan Dwight↗

Vaporization behavior of Ir 4 (CO) 12 and Re 2 (CO) 10 measured by torsion effusion gravimetric method

Metal carbonyls are of great importance in chemical vapor deposition (CVD), composite materials fabrication, and other near-net shape technologies. Carbonyl CVD is used for deposition of high-purity metallic and alloy coatings for which vapor pressure data is essential. In this study, we report vapor pressures of solid Ir 4 (CO) 12 and Re 2 (CO) 10 carbonyls measured by using the Knudsen Cell methodology using a torsion effusion thermogravimetric system. The vapor pressure of the Ir 4 (CO) 12 exhibited incongruent vaporization, as the molecular weight (MW) of the effusing species was determined as 128 g/mol as compared to the theoretical MW of 1105 g/mol. It is proposed that the Ir 4 (CO) 12 (s) partially decomposed (~66%) to Ir 4 (CO) 12 (g), Ir(s), and CO(g). The Re 2 (CO) 10 on the other hand, showed congruent behavior with Re 2 (CO) 10 (s) vaporizing to Re 2 (CO) 10 (g) in the measured temperature range. The raw data for vapor pressures was measured using two sets of Knudsen cells with different orifice sizes, and the equilibrium vapor pressures were calculated using Whitman-Motzfeldt methodology. The equilibrium vapor pressures of these carbonyls, partial pressures of gaseous species in case of decomposition, average molecular weights of the effusing gasses were determined. The vapor pressures and Gibbs energies of vaporization reactions of the two above mentioned carbonyls, as well as comparison of vaporization thermodynamics these two carbonyls with other carbonyls from Group VIB to VIIIB are presented in this work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An adaptable dual species effusive source and Zeeman slower design demonstrated with Rb and Li

We present a dual-species effusive source and Zeeman slower designed to produce slow atomic beams of two elements with a large mass difference and with very different oven temperature requirements. We demonstrate this design for the case of {sup 6}Li and {sup 85}Rb and achieve magneto-optical trap (MOT) loading rates equivalent to that reported in prior work on dual species (Rb+Li) Zeeman slowers operating at the same oven temperatures. Key design choices, including thermally separating the effusive sources and using a segmented coil design to enable computer control of the magnetic field profile, ensure that the apparatus can be easily modified to slow other atomic species. By performing the final slowing using the quadrupole magnetic field of the MOT, we are able to shorten our Zeeman slower length making for a more compact system without compromising performance. We outline the construction and analyze the emission properties of our effusive sources. We also verify the performance of the source and slower, and we observe sequential loading rates of 12 × 10{sup 8} atoms/s for a Rb oven temperature of 140 °C and 1.1 × 10{sup 8} atoms/s for a Li reservoir at 460 °C, corresponding to reservoir lifetimes for continuous operation of 10 and 4 years, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pleural homocysteine for malignant pleural effusion: A prospective and double‐blind diagnostic test accuracy study

Abstract Objective To assess the accuracy of pleural fluid homocysteine for discriminating malignant pleural effusion (MPE) and benign pleural effusion (BPE). Methods A total of 194 patients from two cohorts (Hohhot and Changshu) with undiagnosed pleural effusion were prospectively enrolled. Their pleural homocysteine was measured, and its diagnostic accuracy and net benefit for MPE were analyzed by receiver operating characteristic (ROC) curve analysis and decision curve analysis, respectively. Results In the Hohhot cohort ( n = 136) and the Changshu cohort ( n = 58), MPE patients had significantly higher homocysteine levels than BPE patients. The areas under the ROC curves of homocysteine for the diagnosis of MPE were 0.61 ( p = 0.027) and 0.59 ( p = 0.247), respectively. The decision curves of homocysteine were close to the reference line in both the Hohhot cohort and the Changshu cohort. Conclusion The diagnostic accuracy of pleural fluid homocysteine for MPE was low.

Cao, Xi‐Shan↗

GeSn alloys with ∼21% Sn grown by effusion cell molecular beam epitaxy

We report the epitaxial growth of high quality GeSn alloys with Sn compositions up to 21.25 ± 1% by effusion-cell molecular beam epitaxy (MBE). Achieving such a high Sn content with effusion cells is particularly significant, since these sources typically impose stronger radiative heating on the substrate, which is a factor long considered a major obstacle to high-Sn GeSn epitaxy. Contrary to the prevailing assumption that high growth rates are good for suppressing Sn segregation, we demonstrate that carefully controlled low fluxes, combined with stable ultra-low substrate temperatures, enable significant Sn incorporation even under effusion-cell conditions. Structural analyses by high-resolution x-ray diffraction, reciprocal space mapping, atomic force microscopy, and transmission electron microscopy confirm sharp interfaces, high crystallinity, and smooth surfaces at high Sn contents. Furthermore, these findings establish the feasibility of MBE-grown high-Sn GeSn even under diffusion cells, thereby broadening opportunities for Si-compatible photonic and quantum devices.

Alloys↗

Monte Carlo Simulation of a Knudsen Effusion Mass Spectrometer Sampling System

Knudsen flow is easily simulated with a Monte Carlo method. In this study we develop a Visual Basic for Excel (VBA) code to simulate the molecular beam from a vaporizing solid. The system at NASA Glenn uses the restricted collimation method of Chatillon and colleagues, which consists of two apertures between the effusion cell and the ionizer. The diameter of the first aperture is smaller than the diameter of the effusion cell orifice, so the ionizer effectively only sees inside the effusion cell. The code is able to calculate the transmission coefficient through the cell orifice, through the cell orifice and the first aperture, and through the cell orifice and first and second aperatures. Calculated transmission coefficients through the cell orifice are compared to tabulated values to validate the code. Then transmission coefficients are calculated through the cell orifice and both apertures to the ionizer. This allows the geometry (aperture spacing and diameters) of the sampling system the sampling system to be optimized. Calculated transmission factors are also compared to literature values calculated via an analytic method.

Radke, Michael J.↗

Effusion plate using additive manufacturing methods

Additive manufacturing techniques may be utilized to construct effusion plates. Such additive manufacturing techniques may include defining a configuration for an effusion plate having one or more internal cooling channels. The manufacturing techniques may further include depositing a powder into a chamber, applying an energy source to the deposited powder, and consolidating the powder into a cross-sectional shape corresponding to the defined configuration. Such methods may be implemented to construct an effusion plate having one or more channels with a curved cross-sectional geometry.

33 ADVANCED PROPULSION SYSTEMS↗

A Fast-Valve System for Characterizing Effusive-Flow Properties of Vapor-Transport Systems: RIB Applications

Decay losses, associated with the times required for particles to diffuse from ISOL production targets and to effusively-flow to an ion source, must be reduced to as low as practically achievable levels in order to deliver useful beam intensities of short-lived isotopes for research at ISOL based Radioactive Ion Beam (RIB) facilities. We have developed a fast-valve system and complementary 3-D Monte-Carlo code which can be used separately or in combination to assess the effusive-flow properties of vapor-transport systems, independent of size, geometry and chemical properties of the transport species. In this report, we describe the fast valve and present time spectra and characteristic time data for noble gases flowing through serial- and parallel-coupled vapor-transport systems similar in geometry but longer than those used for RIB generation at the HRIBF with and without target coating matrices.

43 PARTICLE ACCELERATORS↗

Cascaded two-photon spectroscopy of Yb atoms with a transportable effusive atomic beam apparatus

We present a transportable effusive atomic beam apparatus for cascaded two-photon spectroscopy of the dipole-forbidden transition (6s{sup 2} {sup 1}S{sub 0}{r_reversible} 6s7s {sup 1}S{sub 0}) of Yb atoms. An ohmic-heating effusive oven is designed to have a reservoir volume of 1.6 cm{sup 3} and a high degree of atomic beam collimation angle of 30 mrad. The new atomic beam apparatus allows us to detect the spontaneously cascaded two-photons from the 6s7s{sup 1}S{sub 0} state via the intercombination 6s6p{sup 3}P{sub 1} state with a high signal-to-noise ratio even at the temperature of 340 Degree-Sign C. This is made possible in our apparatus because of the enhanced atomic beam flux and superior detection solid angle.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: Design principles of a linear array multi-channel effusive metal-vapor atom source

Atomic beams can easily be produced by allowing atoms to effuse through a channel. In an earlier investigation [A. Majumder et al., Vacuum 83, 989 (2009)], we had designed, fabricated, and characterized an effusive metal-vapor source using collinear-array of multi-channel. In this note, we describe the theoretical basis of designing the source. Atom density in atomic beam has been estimated using a set of analytical expressions for long-channel operated in transparent mode. Parametric studies on aspect ratio of channel, inter-channel separation, beam width, and vertical distance from the source are carried out. They are useful in providing physical picture and optimizing design parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low pressure gas flow analysis through an effusive inlet using mass spectrometry

A mass spectrometric method for analyzing flow past and through an effusive inlet designed for use on the tethered satellite and other entering vehicles is discussed. Source stream concentrations of species in a gaseous mixture are determined using a calibration of measured mass spectral intensities versus source stream pressure for standard gas mixtures and pure gases. Concentrations are shown to be accurate within experimental error. Theoretical explanations for observed mass discrimination effects as they relate to the various flow situations in the effusive inlet and the experimental apparatus are discussed.

Brown, David R.↗

Increasing the yield of Ar((sup 3)P(sub 2, 0)) and Ne((sub 3)P(sub 2, 0)) effusing from a glow discharge by using a longitudinal magnetic field

It is demonstrated that a longitudinal magnetic field applied to a low-pressure, low-voltage, hot cathode glow discharge will substantially increase the intensity of metastable atoms effusing from a central anode slit. For an argon discharge there is a fourfold increase in the effusing Ar((sup 3)P(sub 2, 0)) atom intensity and for neon there is a 14-fold increase in Ne((sup 3)P(sub 2, 0)) intensity.

Barrios, A.↗

Effusive silicic volcanism in the Central Andes: The Chao dacite and other young lavas of the Altiplano-Puna Volcanic Complex

The largest known Quaternary silicic lava body in the world is Cerro Chao in north Chile, a 14-km-long coulee with a volume of at least 26 cu km. It is the largest of a group of several closely similar dacitic lavas erupted during a recent (less than 100,000 year old) magmatic episode in the Altiplano-Puna Volcanic Complex (APVC; 21-24 deg S) of the Centra; Andean Volcanic Zone. The eruption of Chao proceeded in three phases. Phase 1 was explosive and produced approximately 1 cu km of coarse, nonwelded dacitic pumice deposits and later block and ash flows that form an apron in front of the main lava body. Phase 2 was dominantly effusive and erupted approximately 22.5 cu km of magma in the form of a composite coulee covering approximately 53 sq km with a 400-m-high flow front and a small cone of poorly expanded pumice around the vent. The lava is homogeneous with rare flow banding and vesicular tops and selvages. Ogives (flow ridges) reaching heights of 30 m form prominent features on its surface. Phase 3 produced a 6-km-long, 3-km-wide flow that emanated from a collapsed dome. Ogives are subdued, and the lava is glassier than that produced in previous phases. All the Chao products are crystal-rich high-K dacites and rhyodacites with phenocrysts of plagioclase, quartz, hornblende, biotite, sphene, rare snidine, and oxides. Phenocryst contents reach 40-60 vol % (vesicle free) in the main phase 2 lavas but are lower in the phase 1 (20-25%) and phase 3 (approximately 40%) lavas. Ovoid andesitic inclusions with vesicular interiors and chilled margins up to 10 cm are found in the later stages of phase 2 and compose up to 5% of the phase 3 lava. There is little evidence for preeruptive zonation of the magma body in composition, temperature (approximately 840 C), fO2 (19(exp -11), or water content, so we propose that eruption of the Chao complex was driven by intrusion of fresh, hot andesitic magma into a crystallizing and largely homogeneous body of dacitic magma. Morphological measurements suggest that the Chao lavas had internal plastic viscosities of 10(exp 10) to 10(exp 12) Pa s, apparent viscosities of 10(exp 9) Pa s, surface viscosities of 10(exp 15) to 10(exp 24) Pa s, and a yield strength of 8 x 10(exp 5) Pa. These estimates indicate that Chao would have exhibited largely similar rheological properties to other silicic lava extrusions, notwithstanding its high phenocryst content. We suggest that Chao's anomalous size is a function of both the relatively steep local slope (20 deg to 3 deg) and the available volume of magma. The eruption duration for Chao's emplacement is thought to have been about 100 to 150 years, with maximum effusion rates of about 25 cu m/s for short periods. Four other lavas in the vicinity with volumes of approximately 5 cu km closely resemble Chao and are probably comagnetic. The suite as a whole shares a petrologic and chemical similarity with the voluminous regional Tertiary to Pleistocene ignimbrites of the APVC and may be derived from a zone of silicic magmatism that is thought to have been active since the late Tertiary. Chao and the other young lavas may represent either the waning of this system or a new episode fueled by intrusions of mafic magma.

De Silva, S. L.↗

Measuring Thermodynamic Properties of Metals and Alloys With Knudsen Effusion Mass Spectrometry

This report reviews Knudsen effusion mass spectrometry (KEMS) as it relates to thermodynamic measurements of metals and alloys. First, general aspects are reviewed, with emphasis on the Knudsen-cell vapor source and molecular beam formation, and mass spectrometry issues germane to this type of instrument are discussed briefly. The relationship between the vapor pressure inside the effusion cell and the measured ion intensity is the key to KEMS and is derived in detail. Then common methods used to determine thermodynamic quantities with KEMS are discussed. Enthalpies of vaporization, the fundamental measurement, are determined from the variation of relative partial pressure with temperature using the second-law method or by calculating a free energy of formation and subtracting the entropy contribution using the third-law method. For single-cell KEMS instruments, measurements can be used to determine the partial Gibbs free energy if the sensitivity factor remains constant over multiple experiments. The ion-current ratio method and dimer-monomer method are also viable in some systems. For a multiple-cell KEMS instrument, activities are obtained by direct comparison with a suitable component reference state or a secondary standard. Internal checks for correct instrument operation and general procedural guidelines also are discussed. Finally, general comments are made about future directions in measuring alloy thermodynamics with KEMS.

Copland, Evan H.↗