Engineering PapersSearch

SEARCH · Engineering Papers

Results for “effective heat capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of a BISON validation case for the TRISO transient irradiations in NSRR using effective heat capacity methods

The current tristructural isotropic (TRISO) fuel assessment and validation database in BISON primarily covers steady- state irradiation and high-temperature furnace testing. Transient assessment cases are potentially needed to support U.S. industry efforts in designing and deploying commercial reactors using TRISO fuels. Historical transient tests in- volving TRISO fuels used highly conservative conditions compared to the typical high-temperature gas-cooled reactor accident scenarios. Despite this, modeling historical transient tests is fundamental for evaluating BISON’s predictive capabilities, adapting material properties for high-temperature and high-particle-power regimes, and developing a sys- tematic validation approach for TRISO transient applications. This work developed a 1D model of transient experiments carried out at the Nuclear Safety Research Reactor using BISON. BISON’s predictions of energy deposition, UO 2 melting onset, and molten volume fractions are compared against experimental measurements. Melting was modeled using an effective specific heat capacity model for UO 2 . We found that BISON’s predictions are in reasonable agreement with experimental data for low-energy-deposition cases, and that BISON overpredicts melting at higher energy depositions. We also discuss the potential causes of discrepancies between the simulated and measured results and propose ways to further develop the model. Although these simulations used conservative conditions compared to those expected for actual TRISO-fueled reactors, they extended the range of conditions reflected in the data in the existing BISON database for TRISO fuels.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Development of a TRISO assessment case for BISON based on transient experiments in the NSRR

The tristructural isotropic (TRISO) fuel assessment and validation database currently available in BISON is based mainly on steady-state irradiation and high-temperature furnace testing. Transient assessment cases are needed to support ongoing U.S. industry efforts to design and deploy commercial reactors that utilize TRISO fuels. Most available historical transient tests involving TRISO fuels were characterized by power densities, temperatures, and energy depositions that were highly conservative with respect to typical high-temperature gas-cooled reactor (HTGR) accident conditions. Nonetheless, assessment of BISON's predictive capabilities, adaptation of material properties toward high-temperature and high-particle-power regimes, and development of a systematic approach to validating BISON for TRISO transient applications now motivate the modeling of historical transient tests. This work describes the development of 1-D thermal models of transient experiments conducted at the Nuclear Safety Research Reactor (NSRR) in Japan, with BISON predictions of energy deposition, UO2 melting onset, and molten volume fractions being compared against experimental measurements. Melting is accounted for by defining an effective specific heat capacity for UO2—one that leverages the material's heat of melting. BISON's predictions of energy deposition and molten volume fraction are in good agreement with the experimental data from the low-energy-deposition tests; however, BISON tends to overpredict melting at higher energy depositions. Though overly conservative compared to the operating conditions expected for near-term TRISO-fueled reactor applications, these simulations effectively exercise BISON TRISO models over a wider range of conditions than those encompassed by the existing assessment database. Potential contributors to the observed discrepancies are noted and additional future developments proposed.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Hot season gets hotter due to rainfall delay over tropical land in a warming climate

Tropical land generally experiences the hottest period (spring) in a year just before the onset of wet season. Previous studies suggested that in a warming climate, the wet season would come later, but its origin is debated and its impact on temperature remains unknown. Here, we find that the warming of hot season would be amplified under global warming, and refer to it as “hot-season-gets-hotter” phenomenon. The amplified hot season warming is closely tied to the amplified warming of hot temperature percentiles. The hot-season-gets-hotter phenomenon is mainly due to the rainfall delay and most evident in the Amazon, where spring is warming by almost 1?K more than the annual mean and the 99th percentile temperatures are warming ~30% more than the mean by the end of 21st century in a high emission scenario. Comparing experiments with and without land-atmosphere coupling, it is further found that the rainfall delay is initially driven by the enhanced effective atmospheric heat capacity and then substantially amplified by positive soil moisture-atmosphere feedback. In the satellite period, observations consistently show that the hot-season-gets-hotter phenomenon has already emerged along with the rainfall delay in the Amazon. Intensified hot and dry spring climate can enhance risks of drought, heatwaves and wildfires, threatening the Amazon forest and habitats in the tropics.

54 ENVIRONMENTAL SCIENCES

Quantifying Uncertainties in Heat Capacity Measurements of Molten Salts Determined Using Differential Scanning Calorimetry

Uncertainty in specific heat capacity values of a molten salt determined by using differential scanning calorimetry (DSC) was assessed based on the precision of replicate measurements of heat flows used in the calculation and effects of corrections that are commonly made to heat flow measurements. The ratio method of determining heat capacity was applied using the results of replicate heat flow measurements made with two empty cells, a sapphire reference material, and three samples of a doped NaCl-UCl 3 salt mixture. Replicate measurements with empty cells were used to quantify the effects of system instabilities and sensitivities on the measured heat flows of sapphire and salt. The combined effects of uncertainties in individual heat flow measurements made with blank cells using this system were quantified to be 2.6 μV based on isothermal holds before and after the scan, with cell placement adding the greatest uncertainty. This value was used as the tolerance for accepting background-corrected heat flows measured with sapphire and salt to calculate the specific heat capacity. The acceptable heat flows measured for sapphire and salt over the temperature range of 540 to 725 °C resulted in calculated specific heat capacity values ranging from 0.53 to 0.91 J g −1 K −1 with an overall average value of 0.70 J g −1 K −1 and an uncertainty of 0.22 J g −1 K −1 at the 99 % confidence level. The combined uncertainty in the specific heat capacity masked detection of any effect of temperature or salt composition that occurred.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Smaller and faster: a review of conventional and nanocalorimetry techniques for determining thermophysical properties of nuclear materials

Thermal analysis of nuclear materials is critical for the advancement of nuclear technology. The heat effects associated with heat capacity, phase transformation, and radiation damage can be measured with conventional calorimeters. However, conventional calorimetric techniques are often restricted in terms of heating rate and sample mass, especially when studying the limited amounts of materials subject to extreme conditions. In this review, we summarize conventional calorimetric studies of critical thermophysical and thermochemical properties of pure actinide metals (U, Np, Am, Pu), fast reactor metallic fuel alloy systems (U–Zr, U–Pu–Zr, Pu–U, Pu–Zr), and actinide oxides that are primary constituents or transmutation products in light water reactor fuel rods (U–O, Np–O, Am–O, Pu–O, Pu–U–O). Adiabatic and drop calorimetry have been the primary techniques used for these studies, however the development of fast scanning calorimetry using micro-electro-mechanical-based systems allows determination of thermodynamic properties from smaller sample masses. We report recent investigations that leverage the fast heating rates of nanocalorimetry by itself or combined with other characterization techniques. Furthermore, we then discuss opportunities for nanocalorimetry to provide solutions to some of the technical challenges inherent in thermal analysis of nuclear materials, namely a reduction in sample activity, emulating heating transients, investigation of phase evolution in irradiated samples, and characterization of radiation damage evolution. Nanocalorimetry has the potential to significantly advance the understanding of thermophysical properties in nuclear materials and thus accelerate the development of nuclear technology.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Quantum Oscillations in the Heat Capacity of Kondo Insulator YbB 12

Here, we observe magnetic quantum oscillations in the heat capacity of the Kondo insulator YbB 12 . The frequency of these oscillations, 𝐹 = 700 T, agrees with that from magnetoresistance and torque magnetometry experiments for 𝜇 0 ⁢𝐻 >35 T in the Kondo insulating phase. Remarkably, the quantum-oscillation amplitudes in the heat capacity are substantial, with Δ⁢$\tilde{C}/T$ ≈ 0.5 mJ mol −1 K −2 at 0.8 K, accounting for 13% of the known linear heat-capacity coefficient 𝛾. Double-peak structures of quantum-oscillation amplitudes due to the distribution function of fermions were identified and used to determine the value of the effective mass from the heat capacity, which agrees well with that from torque magnetometry. These observations support bulk charge-neutral fermions contributing to the quantum oscillations in YbB 12 .

36 MATERIALS SCIENCE

Modular Hydronic Room Conditioning System (CRADA NFE-24-10120 Final Report)

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin-tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Modular Hydronic Room Conditioning System

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Physical properties investigation of tetragonal Ba T 2 P 2 (T = Ru, Pd)

The structural, thermal, electrical transport, and magnetic properties of ternary compounds BaT 2 P 2 (T = Ru, Pd) are reported together with electronic structure calculations. Our results show that BaRu 2 P 2 crystallises in the layered tetragonal ThCr 2 Si 2 -type structure (space group I4/mmm) whereas BaPd 2 P 2 adopts the primitive tetragonal CeMg 2 Si 2 -type structure (space group P4/mmm). The combined experimental results and electronic structure calculations suggest metallic and diamagnetic ground states for both materials. Electrical transport measurements further indicate non-Fermi liquid behaviour at low temperatures. Notably, BaRu 2 P 2 exhibits an anomalous feature in the magnetic susceptibility at T ~ 260 K, similar to that observed in BaRu 2 As 2 . A comparison between the bare density of states obtained from electronic structure calculations and the experimentally estimated values suggests the presence of strong correlation effects in the material. Furthermore, the heat capacity of BaPd 2 P 2 , calculated using the full phonon dispersion relation, is in good agreement with the experimental data, particularly at low temperatures, highlighting the significant contribution of optical phonon branches to C P in this temperature range.

flat bands

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)

Heat load measurements for the PIP-II pHB650 cryomodule

This study presents a brief overview of the 1st and 2nd phases and an in-depth analysis of the 3rd phase heat load testing performed on the pHB650 (prototype High Beta 650 MHz) cryomodule at PIP2IT (PIP-II Injector Test Facility), with a focus on both the results and the methodological advancements that have improved testing efficiency and accuracy. A key challenge identified in the testing campaign is the higher-than-expected heat loads observed in the first PIP-II (Proton Improvement Plan II) prototype cryomodules (pSSR1 and pHB650) tested at PIP2IT. Elevated heat loads are concerning given the fixed capacity of the PIP-II cryoplant that is currently being installed at Fermilab. However, understanding the sources of these elevated heat loads offers a critical opportunity to implement effective heat load mitigations on upcoming PIP-II cryomodules to stay within the available capacity of the PIP-II cryoplant. The study includes a summary of test results, descriptions of measurement procedures, and key observations on parameters directly and indirectly related to heat load measurements. Direct observations include measured heat loads and the effectiveness of JT heat exchanger under varying conditions, while indirect observation analyze factors such as the temperature distribution on the two-phase pipe and relief piping under varying conditions. Thermal acoustic oscillations (TAO) were identified during testing, which was mitigated by replacing the original G10 stem with a stainless steel stem equipped with wipers for the cryomodule cooldown valve. A major innovation during pHB650 Phase 3 testing was the development of an automated Python script to streamline data acquisition, analysis, and reporting of heat load results. This script automatically retrieved data from ACNET (Accelerator Control Network), performed heat load calculations, and generated detailed reports featuring plots and tables. This advancement significantly reduced manual labor and enhanced the thoroughness of data analysis compared to earlier campaigns. The heat load test reports were promptly uploaded to the electronic logbook shortly after each test, enabling rapid feedback and collaboration between the SRF and cryogenic teams. The heat load measurements included various components: HTTS (high-temperature thermal shield), LTTS (low-temperature thermal shield), 2K isothermal and non-isothermal heat loads. Results were recorded both within the cryomodule and between the bayonet can supply and return. Measurements were conducted under different operating conditions such as "standard", "linac", and "simulated dynamic". Additionally, HTTS and LTTS heat loads were calculated in real time, allowing for the tracking of thermal stability and identification of changes during testing, both in steady-state and transient conditions. The results of this testing campaign not only provide valuable insights into the performance of the pHB650 cryomodule but also highlight best practices and lessons learned that will inform future cryomodule testing at PIP2IT. These include adopting automated tools for data analysis, refining real-time measurement capabilities, and emphasizing detailed pre-test planning. The framework established in this campaign aims to set an improved standard for cryomodule testing and heat load reporting in future cryomodule test campaigns.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]

Effects of Heat Treatment on Microstructure, Thermal Transport and Stability in SRF Niobium

Efficient heat transfer and thermal stability are critical for preventing thermal quench and ensuring the high performance and reliability of superconducting radiofrequency (SRF) cavities, especially under high RF fields. In this article, we investigate thermal conductivity and heat capacity of high-purity cold-worked niobium used in SRF applications, with a particular focus on the effects of high-temperature heat treatments. Our measurements reveal a pronounced sensitivity of thermal transport and thermodynamic properties to the underlying microstructure such as grain size and dislocation density. The results show the critical role of controlled heat treatment processes in optimizing the thermal performance of SRF niobium, providing valuable insights for improving cavity fabrication and processing.

36 MATERIALS SCIENCE

Consumer safety-oriented scheduling of rotating power outages during heat waves

Extreme heat events have widespread effects on power systems, reducing available generation capacity, limiting transmission capabilities, and causing unusual demand patterns on the consumer side. As these combined effects expose bulk transmission systems to potential large-scale blackouts, utilities may be required to schedule and apply rotating outages, by temporarily and alternately disconnecting distribution substations to reduce overload. However, utilities lack mechanisms to inform these events, exacerbating the negative effects of heat waves on affected communities. This paper introduces a novel framework for scheduling rotating outages during heat waves while considering impacts on consumers’ safety. Instead of random sequential load shedding, we propose a methodology to rotate power outages considering a metric that quantifies the indoor overheating risk of groups of consumers during a power outage. The overheating risk is derived from a detailed building simulation using CityBES, where the buildings are modeled based on available data—use type, year built, floor area, number of stories, location—while presence of air conditioning and occupancy are calibrated from smart meter data. Based on the metric, an algorithm to schedule the rotating outages is applied to prioritize feeders for disconnection at each hour according to their overheating risk to meet a utility load reduction target. Applied to two substations and seven feeders in the Portland General Electric territory, the results show that this approach effectively leads to the lowest overheating risk during the resulting outage schedules, with an average 10.1% lower overheating compared to uninformed schedules.

Building thermal simulation

Estimation of intensity, footprint, and capacity of surface urban heat islands using a direction-enhanced adaptive synchronous extraction (DEASE) method

Here, the surface urban heat island (SUHI) effect, assessed through remotely sensed land surface temperature (LST), remains a focal point in urban climate research. Conventional indicators like SUHI intensity (SUHII) and footprint (SUHIF) capture peak values and spatial extent but fail to account for the cumulative thermal load—a critical dimension reflecting the total heat exposure imposed by spatially continuous warming, which directly limits a holistic assessment of ecological and societal impacts of the SUHI effect. Therefore, this study introduces an indicator termed SUHI capacity (SUHIC), designed to quantify the aggregated SUHI effect by integrating the magnitude of the warming signal across all affected areas, thereby enabling a more comprehensive evaluation of urban thermal environments. Furthermore, a direction-enhanced adaptive synchronous extraction (DEASE) method is proposed for the quantification of SUHIC. This method can dynamically identify the optimal background reference area based on the urban-rural LST gradients in various directions within the city, without relying on predefined mathematical models as previously. The results from 102 European cities first confirm that the directional variations in urban-rural LST gradients, and the DEASE method can effectively capture these distinctions for the simultaneous estimation of SUHII, SUHIF, and SUHIC. Secondly, the spatial patterns of absolute SUHIC values show strong associations with those of SUHIF (R2>0.86), while its relative values (normalized by the area of urban) align more closely with SUHII (R2 > 0.64). More importantly, SUHIC can serve as a crucial reference for assessing the urban thermal signal when SUHII and SUHIF diverge. The proposed method and framework contribute to standardizing the quantification of the SUHI effect.

Indicator

Quantum critical point followed by Kondo-like behavior due to Cu substitution in the itinerant antiferromagnet La 2 ⁢(Cu 𝑥 ⁢Ni 1−𝑥 ) 7

La 2 ⁢Ni 7 is an itinerant magnetic system with a small ordered moment of ∼ 0.1⁢µ 𝐵 /Ni and a series of antiferromagnetic (AFM) transitions at 𝑇 1 = 61.0K, 𝑇 2 = 56.5K, and 𝑇 3 = 42.2K. 𝑀 ⁡(𝐻), and 𝜌 ⁡(𝐻) isotherms as well as constant field 𝑀⁡ (𝑇) and 𝜌 ⁡(𝑇) measurements on single-crystalline samples manifest a complex, anisotropic 𝐻−𝑇 phase diagram with multiple phase lines. Here, in this study, we present the growth and characterization of single crystals of the La 2 ⁢(Cu 𝑥 ⁢Ni 1−𝑥 ) 7 series for 0 ≤ 𝑥 ≤ 0.181. We measured powder x-ray diffraction and composition, as well as anisotropic temperature- and field-dependent resistivity, temperature- and field-dependent magnetization, and temperature-dependent heat capacity on these single crystals. Using the measured data we infer a transition temperature-composition (𝑇−𝑥) phase diagram for this system to study the evolution of the AFM ordering upon Cu substitution. For 0 ≤ 𝑥 ≤ 0.097, the system remains magnetically ordered at base temperature with 𝑥 ≤ 0.012, showing signs of multiple AFM ordering temperatures. For the higher substitution levels 0.125 ≤ 𝑥 ≤ 0.181, there are no signatures of magnetic ordering, but anomalous features in resistance and heat capacity data are observed which are consistent with the Kondo effect in this system. The intermediate 𝑥 = 0.105 sample lies between the magnetic ordered and the Kondo regime and is in the vicinity of the AFM quantum critical point (QCP). Thus, La 2⁢ (Cu 𝑥 ⁢Ni 1−𝑥 ) 7 is an example of a small moment system that can be tuned through a QCP. Given these data combined with the fact that the La 2⁢ Ni 7 structure has kagomelike, Ni sublattices running perpendicular to the crystallographic 𝑐 axis, and a predicted 3⁢𝑑-electron flat band that contributes to the density of states near the Fermi energy, La 2 ⁢(Cu 𝑥 ⁢Ni 1−𝑥 ) 7 becomes a promising system to host and study exotic physics.

Das, Atreyee [Ames Laboratory, and Iowa State Univ

Property Measurements of LiF-NaF-KF Molten Salts Doped with Corrosion Products and Oxygen

Measurements of thermophysical properties of molten salts are needed for modeling and simulation activities that support the development of molten salt reactor (MSR) technologies. Properties of interest including transition temperatures, phase behavior, heat capacity, density, volumetric thermal expansion, surface tension, viscosity, thermal diffusivity, thermal conductivity, and vapor pressure are being performed at Argonne. Results of these property measurements are suitable for use in evaluating reactor performance during startup and the early operating life of the reactor. Ingressions of oxygen and moisture into the fuel salt are expected to occur at different times during the operating life of the reactor due to system leaks, maintenance, and refueling activities. The presence of these environmental contaminants induces corrosion of structural materials. The introduction of corrosion-derived species, oxygen and moisture is expected to affect the physical and chemical properties of the salt and operation of the reactor. Previous work performed at Argonne evaluated the effects of fission product dopants on the thermal properties of eutectic LiF-NaF-KF (FLiNaK). Properties of FLiNaK are commonly used to represent those of fluoride-bearing fuel salts. Metallic corrosion products such as chromium and nickel ions together with dissolved oxygen are expected to affect system redox differently than the accumulation of fission products. Work summarized in this report was performed to measure the effects of corrosion products and dissolved oxygen on the phase transitions, and specific heat capacity of FLiNaK. Thermophysical property measurements were made using four salts that were prepared by doping aliquots of a eutectic mixture of FLiNaK with surrogate corrosion products. Controlled additions of CrF 3 and NiF 2 were used as surrogates for corrosion product contamination anticipated during extended reactor operations in which fuel salt is in contact with steel reactor components. Controlled additions of UF 4 from two sources containing known amounts of UO 2 at different concentrations were used to represent oxygen contamination. The phase transitions and specific heat capacities of the four salts were measured by using differential scanning calorimetry. Measurements were made at temperatures spanning the range of 500−900 °C, which is the expected operating range of MSRs. Measured property values were compared to values measured previously with eutectic FLiNaK without dopants. Differences between property values measured for the doped and non-doped salts were compared with the uncertainties of the measurements to determine the significance of the effect of corrosion products and oxygen on salt properties.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Magnetic dilution in the triangular lattice antiferromagnet NaYb 1−𝑥 ⁢Lu 𝑥 ⁢O 2

The delafossitelike compound NaYbO 2 hosts a triangular lattice of Yb 3+ moments and is a promising candidate for the realization of a quantum spin liquid ground state—an exotic, quantum-disordered magnetic phase featuring long-range entanglement of spins. Tuning this system away from this quantum-disordered regime toward classical order or spin freezing is a powerful approach to shed light on the nature of the parent ground state. Here we leverage the substitution of nonmagnetic Lu 3+ onto the Yb 3+ sites to study the effects of magnetic disorder in NaYbO 2 using low-temperature ac susceptibility, heat capacity, and muon spin relaxation (𝜇⁢SR) measurements. Here, our 𝜇⁢SR measurements reveal resilient, correlated magnetic fluctuations that persist to at least 15% dilution, precluding conventional spin freezing and magnetic inhomogeneity. Heat capacity and magnetic susceptibility resolve a rapid suppression of the field-induced “up-up-down” magnetic order upon dilution and a crossover in the power-law behavior of the low-temperature magnetic excitations associated with the zero-field quantum disordered ground state. Taken together, these results support the notion of a robust network of entangled moments in NaYbO 2 and provide experimental validation of several models of a Heisenberg triangular lattice antiferromagnet in the presence of disorder.

Muon spin relaxation & rotation

Cyclic moisture reactivation of calcium sorbents for long duration thermochemical energy storage

The transition to a flexible and reliable energy infrastructure, using electro-thermal energy generation technologies such as geothermal, concentrated solar power, and nuclear, usually demands simultaneous advancement of thermal energy storage (TES) to support on-demand electricity generation and industrial applications while mitigating the inherent intermittency of renewable energy sources and power outages from direct energy generation. Among TES technologies, thermochemical energy storage (TCES) based on calcium looping emerges as a compelling high-power energy storage candidate due to its high reaction enthalpy, compatibility with elevated operating temperatures, and abundance of low-cost materials. However, the long-term durability of calcium-based sorbents for TCES is hindered by surface sintering and particle aggregation, leading to performance degradation over repeated thermal cycles. This study explores a moisture hydration-based strategy to regenerate a degraded calcium sorbent and mitigate performance degradation for long duration TCES. The addition of moisture transforms calcium oxide into calcium hydroxide and produces intercalation water layers, associated with a regenerated surface area and reduced calcium oxide crystallite size. Both these effects are beneficial in restoring the sorbents' reactivity for carbonization. Additionally, an optimized hydration-assisted reactivation protocol balances the recovered energy storage capacity with heating penalty required for moisture removal from hydrated samples, resulting in an enhanced energy storage capacity up to 176% compared to benchmark sorbents that undergo cycling without reactivation after 60 cycles. In conclusion, these results highlight the potential of hydration-assisted reactivation to enhance the long-term performance of TCES, providing an effective pathway to advancing electro-thermal storage technologies.

36 MATERIALS SCIENCE