Dynamic measurement of impurity ion transport in runaway electron plateaus in DIII-D
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
This study presents magnetic resonance velocimetry (MRV) Reynolds Stress measurements in a periodic hill channel with a hill Reynolds number of Re = 29,500. The velocity encoding scheme is based on the ICOSA6 method with six icosahedral encoding directions and multiple encoding values are measured to increase the dynamic range. The full Reynolds stress tensor is obtained from a voxel-wise three-dimensional Gaussian fit using the magnitude data of all acquisitions. The MRV results are compared to a wall-resolved large eddy simulation and laser Doppler velocimetry measurements conducted in the same channel. It is shown that the MRV Reynolds stress data have excellent precision and agree qualitatively with the reference data. However, there are apparent systematic deviations. One of the most prominent error contributions is the signal attenuation caused by higher orders of motion, which leads to an overestimation of the turbulence level. Another fundamental error is identified in the assumption that the turbulence is Gaussian distributed. With the presented reconstruction technique, the MRV data are fitted to a statistical model, and depending on the examined flow setup, the Gaussian model can lead to considerable errors. Possible ways of how to reduce all identified errors are presented. In summary, this technique enables Reynolds stress tensor measurements in complex internal flows with high dynamic range and excellent precision. However, several issues need to be resolved to make the turbulence quantification more accurate.
4th quarter presentation for FY20 Annual SDRD meeting to be held Sept. 23-24 on WebEx. An embedded movie is also attached. Dynamic Measurements of the Structural Evolution of Material Defects at the Mesoscale, NLV-001-19, Year 2
Optical fiber-based sensors are commonly used for industrial monitoring and control processes due to their small size, resistance to electromagnetic interference, and ability to perform a wide variety of high-precision measurements. However, implementing optical fiber sensors in harsh environments is challenging because they are small and fragile. Proper packaging of fiber-optic sensors could extend their use to harsh environments, including at high temperature and under high radiation. Furthermore, conventional fiber optic-based measurement systems often use computationally expensive signal processing algorithms which hinder their use in high-frequency dynamic applications. This work reports on the design of an optical fiber-pressure sensor system based on low-coherence interferometry that uses a metal-embedded optical fiber to provide a robust sensor package. Additionally, a novel phase demodulation scheme is proposed to extract length changes from the deformation of a thin diaphragm within a Fabry–Pérot cavity to measure pressure. The sensor has been tested to ±100 kPa, has a theoretical linear response over a 270 kPa dynamic range (24 dB maximum signal-to-noise ratio), and can resolve pressure transients up to 3910 kPa/s. Sampling at 100 kHz, the present sensor can resolve 2 kPa dynamic pressures at frequencies up to 2 kHz. Faster transients on the order of tens to hundreds of kHz can theoretically be resolved at the expense of decreasing the maximum resolvable amplitude. A methodology for designing a LCI pressure sensor for a given application is outlined based on the limitations imposed by the Nyquist criterion, the diaphragm's resonant frequency, the LCI optoelectronics, and the phase demodulation scheme. The sensor is the first to implement a low-coherence light source and a Fabry–Pérot interferometer designed to provide real-time high-fidelity pressure measurements using a metal-embedded optical fiber. The demonstrated sensor provides a platform for sensing in harsh conditions such as in nuclear and energy applications.
We investigate the segmental dynamics and ion transport in two chemically distinct polymer electrolytes, poly(2-cyanoethyl acrylate) (PCEA) and poly(ethylene oxide) (PEO), and their mixtures with lithium bis(trifluoromethane)sulfonimide (LiTFSI) salt. Quasi-elastic neutron scattering experiments reveal slow dynamics in PCEA/LiTFSI relative to that in PEO/LiTFSI, translating to monomeric friction coefficients that are orders of magnitude different. In spite of the enhanced salt dissociation in PCEA due to the presence of polar groups, ion transport is largely dominated by the effect of increased monomeric friction in the pure polymer. Conductivity in these systems is quantified through a simple expression combining salt dissociation, the monomeric friction in the pure polymer, and the effect of added salt on the monomeric friction.
Reducing protein adhesion is a critical strategy in fouling-resistant material innovation, with broad applications spanning biomedical and healthcare devices, biosensors, industrial and environmental systems, and other important technological domains. Here, in this study, we elucidated protein adhesion behavior on polystyrene-based thin films by neutron reflectometry (NR) and quartz crystal microbalance with dissipation (QCM-D), using both lysozyme and bovine serum albumin (BSA) as model proteins. To this end, semifluorinated polystyrene thin films with gradient wettability and surface energy were fabricated through dry processing using plasma oxidation and gas-phase deposition. Although it is believed that a fully fluorinated alkyl chain offers extremely low surface energy, thus rejecting foulants, and has been used in many fouling-resistant surface designs, enhanced protein–surface interactions were observed consistently in NR and QCM-D results, due to the combined effects of surface morphology and chemistry. On the contrary, depositing shorter fluorinated silane onto a hydrophilic PS surface contributed to a more homogeneous nanoscale fluorine coating, resulting in less initial protein adsorption and improved surface recovery. Comparative analysis of proteins with different sizes on the nanopatterned semifluorinated surface revealed the influence of molecular characteristics on surface interactions. Lysozyme, being smaller and more compact, showed faster adsorption kinetics and higher surface coverage but largely reversible binding, whereas BSA, with its larger and more flexible structure, formed broader and more stable interfacial layers. This study fills the gap in understanding protein adhesion within the range of hydrophobicity (water contact angle ∼90°), as current strategies often associate with extreme hydrophilic and superhydrophobic surfaces due to hydration or low-surface-energy rejection mechanisms, respectively. It also provides in-depth insights into current combinatorial fouling-resistant surface design.
We present results from a new experiment, fielded on the MAGPIE pulsed power generator, producing a rotating, boundary-free plasma with no pre-imposed magnetic field. Angular momentum is introduced to the rotating system by the oblique collision of multiple plasma flows, which are driven by x-ray ablation of solid targets using the soft x-rays emitted from the implosion of wire array z-pinches. This produces a hydrodynamically stable plasma which undergoes ~2-3 rotations over the duration of the experiment, significantly more than previous pulsed-power platforms. Estimating the angular frequency from the electron density profile in the inner part of the rotating plasma shows that it has a quasi-Keplerian rotation profile. The system also allows for the addition of a controllable magnetic field. This, combined with the sufficiently large Reynolds (~10 5 ) and magnetic Reynolds (~10) numbers, will enable investigation of the effect of magnetic field on the structure and stability of the rotating plasma.
Local early-type galaxies (ETGs) with directly measured black hole masses, M bh , have been reported to represent a biased sample relative to the ETG population at large. Such galaxies with Spitzer Space Telescope imaging have been purported to possess velocity dispersions, σ, at least ∼0.1 dex larger for a given galaxy stellar mass, M * , gal , than is typically observed among thousands of ETGs imaged by the Sloan Digital Sky Survey (SDSS). This apparent offset led Shankar et al. to reduce the normalisation of the observed M bh ∝ σ 5 relation by at least ∼0.5 dex to give their ‘intrinsic relations’, including σ-based modifications to the observed M bh –M * , gal relation. These modifications were based on the untested assumption that the stellar masses had been derived consistently between the two samples. Here, we provide the necessary check using galaxies common to the Spitzer Survey of Stellar Structure in Galaxies (S 4 G) and the SDSS. We find that the stellar masses of galaxies with and without directly measured black hole masses had appeared offset from each other due to the use of inconsistent stellar mass-to-light ratios, Υ * , for the optical and infrared data. We briefly discuss the ‘intrinsic relations’ and why some of these will at times appear to have had partial success when applied to data based on similarly inconsistent values ofΥ * . Finally, we reiterate the importance of the υ (lower-case Υ) term, which we previously introduced into the M bh –M * relations to help avoid Υ * -related mismatches.
One of the most promising advantages of nonlinear integrable optics is strong amplitude dependent tune shift without degrading the dynamic aperture. The integrable optics test accelerator (IOTA) at Fermilab is constructed around nonlinear lattice elements of the elliptical type as described by Danilov and Nagaitsev. Detuning and dynamic aperture scans in IOTA were performed using a fast dipole kicker and a low emittance electron beam. The evolution of the dynamic aperture and detuning for different configurations of the integrable optics lattice are presented.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
One of the most promising advantages of nonlinear integrable optics is strong amplitude dependent tune shift without degrading the dynamic aperture. The integrable optics test accelerator (IOTA) at Fermilab is constructed around nonlinear lattice elements of the elliptical type as described by Danilov and Nagaitsev. Detuning and dynamic aperture scans in IOTA were performed using a fast dipole kicker and a low emittance electron beam. The evolution of the dynamic aperture and detuning for different configurations of the integrable optics lattice are presented.
SpinQuest is a cutting-edge, high-luminosity Drell-Yan experiment utilizing polarized hy- drogen and deuterium targets to measure the Sivers asymmetry for the light sea quarks in the nucleon. Detecting a nonzero Sivers asymmetry would provide clear evidence for nonzero or- bital angular momentum of sea quarks. The Sivers asymmetry presents itself as an azimuthal asymmetry in the production of virtual photons via the Drell-Yan process, and SpinQuest will be able to measure this asymmetry using the existing SeaQuest dimuon spectrometer. In addi- tion to making measurements sensitive to the sea quark Sivers function, we will also measure the azimuthal asymmetry in the production of J/ψ particles, which is sensitive to the gluon Sivers function. Additionally, observing a sign change in the Sivers asymmetry between this measurement and future measurements at the Electron-Ion Collider would be a test of a funda- mental prediction of Quantum Chromodynamics. In this poster we will review the physics and technology underpinning the experiment.
Explore the source record for details and available documents.
Presentation to be presented during the Site-Directed Research and Development (SDRD) program FY 2021 review meeting (Webex), September 22–23, 2021.
Abstract not provided.
This is a technical report to be published as part of the FY2021 annual overview package. We have designed experiments and developed analytical methods using images from x-ray and electron microscopy in order to quantify the behavior of crystal dislocation defects at their native nanometer-length and micro-length scales. The results of these analyses are used to directly inform theoretical physics models and guide interpretation of dark field x-ray microscopy (DFXM) images that offer spatial resolution surpassing the resolution of beamline optics. Additionally, we developed new analytical methods to automate the alignment of optics hardware used in both synchrotron and x-ray free electron laser beamline facilities. The tools and workflows developed for this project are now being deployed as proof-of-concept in reaction history analysis (RHA) for future programmatic integration.
There are currently few viable diagnostic techniques for in situ measurement of plasma facing component erosion. Digital holography is intended to fill this gap. Progress on the development of single and dual CO 2 laser digital holography diagnostics for in situ plasma facing component erosion is discussed. The dual laser mode’s synthetic wavelength allows the measurable range to be expanded by a factor of ~400 compared to single laser digital holography. This allows the diagnostic to measure surface height changes of up to 4.5 μm in single laser mode and up to 2 mm in dual laser mode. Results include ex situ measurements of plasma eroded targets and also dynamic measurements of nm and μm scale motion of a target mounted on a precision translation stage. Dynamic measurements have successfully been made with the system operating in both single and dual laser modes, from ~50 nm to ~4 μm in single laser mode and up to ~400 μm in dual laser mode (limited only by the stage speed and camera acquisition duration). These results demonstrate the feasibility of using digital holography to characterize plasma facing component erosion dynamically, i.e., during plasma exposure. Results of proof-of-principle in situ digital holographic measurements of targets exposed to an electrothermal arc plasma source are presented.