Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic compression”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Microstructural Changes to Thermally Sprayed Materials Subjected to Dynamic Compression

Dynamic compression of materials can induce a variety of microstructural changes. As thermally-sprayed materials have highly complex microstructures, the expected pressure at which changes occur cannot be predicted a priori. In addition, typical in-situ measurements such as velocimetry are unable to adequately diagnose microstructural changes such as failure or pore collapse. Quasi-isentropic compression experiments with sample recovery were conducted to examine microstructural changes in thermally sprayed tantalum and tantalum-niobium blends up to 8 GPa pressure. Spall fracture was observed in all tests, and post-shot pore volume decreased relative to the initial state. The blended material exhibited larger spall planes with fracture occurring at interphase boundaries. An estimate of the pressure at which pore collapse is complete was determined to be ~26 GPa for pure tantalum and ~19 GPa for the tantalumniobium blend under these loading conditions.

36 MATERIALS SCIENCE↗

DCS - A high flux beamline for time resolved dynamic compression science – Design highlights

The Dynamic Compression Sector (DCS) beamline, a national user facility for time resolved dynamic compression science supported by the National Nuclear Security Administration (NNSA) of the Department of Energy (DOE), has recently completed construction and is being commissioned at Sector 35 of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The beamline consists of a First Optics Enclosure (FOE) and four experimental enclosures. A Kirkpatrick–Baez focusing mirror system with 2.2 mrad incident angles in the FOE delivers pink beam to the experimental stations. A refocusing Kirkpatrick–Baez mirror system is situated in each of the two most downstream enclosures. Experiments can be conducted in either white, monochromatic, pink or monochromatic-reflected beam mode in any of the experimental stations by changing the position of two interlocked components in the FOE. The beamline Radiation Safety System (RSS) components have been designed to handle the continuous beam provided by two in-line revolver undulators with periods of 27 and 30 mm, at closed gap, 150 mA beam current, and passing through a power limiting aperture of 1.5 x 1.0 mm{sup 2}. A novel pink beam end station stop [1] is used to stop the continuous and focused pink beam which can achieve a peak heat flux of 105 kW/mm{sup 2}. A new millisecond shutter design [2] is used to deliver a quick pulse of beam to the sample, synchronized with the dynamic event, the microsecond shutter, and the storage ring clock.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-100 ps laser-driven dynamic compression of solid deuterium with a ∼40 μJ laser pulse

We dynamically compress solid deuterium over <100 ps from initial pressures of 22 GPa to 55 GPa, to final pressures as high as 71 GPa, with <40 μJ of pulse energy. At 25 GPa initial pressure, we measure compression wave speeds consistent with quasi-isentropic compression and a 24% increase in density. The laser drive energy per unit density change is 10{sup 9} times smaller than it is for recent longer (∼30 ns) time scale compression experiments. This suggests that, for a given final density, dynamic compression of hydrogen might be achieved using orders of magnitude lower laser energy than currently used.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Towards in-situ high precision local material velocity measurements in lattice materials under dynamic compression

The study of dynamic compression of materials requires high precision spatial and temporal resolution to infer the material state at any given time. In ultra-fast imaging experiments such as those performed at the Dynamic Compression Sector at the Advanced Photon Source, the current CCD frame rate is less than the X-ray pulse rate necessitating that 4 CCDs be used to image a single scintillator screen to obtain the same projection of transmitted or diffracted beam at time intervals synchronized with the X-ray beam. The use of multiple-camera setups is often employed for a variety of reasons including enhancing the temporal resolution through interleaving frames or increasing the number of viewpoints, for example. Physical corrections are made to have each CCD approximately viewing the same field of view, however we present corrections that can be made after the data collection to further refine and be able to compare movements and changes in the sample between independent CCDs. These software corrections enable higher precision and higher fidelity comparison of position changes due to sample deformation. Furthermore, we present a method to correct images (or frames) as a demonstration toward high fidelity displacement measurements in these types of ultra-fast multi-camera setup experiments.

36 MATERIALS SCIENCE↗

The laser shock station in the dynamic compression sector. I

The Laser Shock Station in the Dynamic Compression Sector [Advanced Photon Source (APS), Argonne National Laboratory] links a laser-driven shock compression platform with high energy x-ray pulses from the APS to achieve in-situ, time-resolved x-ray measurements (diffraction and imaging) in materials subjected to well-characterized, high stress, short duration planar shock waves. Additionally, the combination of this station and the other DCS experimental stations provides a unique and versatile experimental facility to study condensed state phenomena by undertaking real-time, multi-scale measurements in materials subjected to a wide range of shock amplitudes (to above ~350 GPa) and time-durations (~10 ns to 1 μs). The Laser Shock Station uses a 100 joule, 5-17 ns, 351 nm frequency tripled Nd:glass laser with programmable pulse shaping and focal profile smoothing for maximum precision. The laser is capable of a shot every 30 minutes. The interaction chamber contains multiple ports for simultaneous diagnostics, a sample holder that allows sequential exposure for 14 samples without breaking vacuum, the capability to vary the angle between the x-ray beam and laser beam by 135°, and the ability to translate to select one of two types of x-ray beams. X-ray data can be taken with a temporal resolution of ~90 psec. Highly reproducible, planar shocks can be propagated in samples to undertake precise and well-characterized experiments. In a series of ten shots, the absolute variation in the time the shock breaks out at the back of the sample is less than 500ps and the variation in peak particle velocity at the sample/window interface is 4.3%. Lastly, this paper describes the entire DCS Laser Shock Station, including sample fabrication and diagnostics, as well as representative experimental results from shock compressed tantalum to demonstrate the excellent quality of x-ray diffraction data in solid tantalum and to establish the stress for tantalum melting.

47 OTHER INSTRUMENTATION↗

Probing the Hydrogen Melting Line at High Pressures by Dynamic Compression

We investigate the capabilities of dynamic compression by intense heavy ion beams to yield information about the high pressure phases of hydrogen. Employing ab initio simulations and experimental data, a new wide range equation of state for hydrogen is constructed. The results show that the melting line up to its maximum as well as the transition from molecular fluids to fully ionized plasmas can be tested with the beam parameters soon to be available. We demonstrate that x-ray scattering can distinguish between phases and dissociation states.

43 PARTICLE ACCELERATORS↗

Probing the lattice structure of dynamically compressed and released single crystal iron through the alpha to epsilon phase transition

In this work, experiments using broadband Laue x-ray diffraction (XRD) were used to examine the lattice structure of dynamically compressed [100]-oriented single crystal iron samples at the Dynamic Compression Sector at the Advanced Photon Source. These experiments used 1 μm thick iron single crystal samples sandwiched between a polyimide ablator and a polycarbonate window. A 100 J, 10 ns duration laser pulse incident on the polyimide ablator was used to shock compress the iron samples to initial stresses greater than 25 GPa, exceeding the ~13 GPa alpha (body-centered-cubic or bcc structure) to epsilon (hexagonal-close-packed or hcp structure) phase transition stress. XRD measurements were performed at various times relative to the shock wave entering the iron sample: early times, <~150 ps while the initial shock waves propagated through the iron; intermediate times, after the iron equilibrated with the ablator and window reaching a plateau stress state (12 or 17 GPa) lasting several nanoseconds; and late times, during uniaxial strain release. The early time measurements show that in <~150 ps, the high-pressure hcp phase is relaxed with a c/a ratio of 1.61, contrary to previous laser shock experiments where a c/a ratio of 1.7 was inferred. In the plateau stress state and partially released states, XRD measurements showed that the hcp structure retained a c/a ratio of 1.61 with no observable changes in the microstructure. Upon stress release at ~1 GPa/ns release rate, the reverse phase transition (hcp to bcc) to the original single crystal orientation (implying a transformation memory effect) was observed to reach completion somewhere between 13 and 11 GPa, indicating little stress hysteresis under rapid uniaxial strain release. A similar memory effect for the reverse hcp to bcc transformation has been previously observed under hydrostatic compression. However, the bcc/hcp orientation relationships differ somewhat between dynamic and static compression experiments, implying that the transformation pathway under uniaxial dynamic strain differs from the Burgers mechanism.

36 MATERIALS SCIENCE↗

Simultaneous broadband laser ranging and photonic Doppler velocimetry for dynamic compression experiments

A diagnostic was developed to simultaneously measure both the distance and velocity of rapidly moving surfaces in dynamic compression experiments, specifically non-planar experiments where integrating the velocity in one direction does not always give the material position accurately. The diagnostic is constructed mainly from fiber-optic telecommunications components. The distance measurement is based on a technique described by Xia and Zhang [Opt. Express 18, 4118 (2010)], which determines the target distance every 20 ns and is independent of the target speed. We have extended the full range of the diagnostic to several centimeters to allow its use in dynamic experiments, and we multiplexed it with a photonic Doppler velocimetry (PDV) system so that distance and velocity histories can be measured simultaneously using one fiber-optic probe. The diagnostic was demonstrated on a spinning square cylinder to show how integrating a PDV record can give an incorrect surface position and how the ranging diagnostic described here obtains it directly. The diagnostic was also tested on an explosive experiment where copper fragments and surface ejecta were identified in both the distance and velocity signals. We show how the distance measurements complement the velocity data. Potential applications are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inference of strength and phase transition kinetics in dynamically-compressed tin

Dynamic compression experiments in condensed matter are of interest in part because they provide opportunities to examine material response under extreme conditions; however, the inference of material behavior from dynamic experiments is challenging in the presence of phase transitions exhibiting kinetic processes. Demonstrating an approach to quantitative interpretation of such dynamic experiments, here we present a Bayesian model calibration of strength and phase transformation parameters to data drawn from pulsed power and gas gun shot experiments. The posterior predictions of the Bayesian model capture the experimental measurements and account for the various uncertainties in the experimental configurations. This holistic approach to model calibration utilizing multiple types of experimental data identifies important cross correlations among kinetics, strength, and the phase boundary. Improved insight into potential sources of current model form error is provided by comparing the differences between calibrations against different subsets of the experimental data.

42 ENGINEERING↗

A platform for x-ray absorption fine structure study of dynamically compressed materials above 1 Mbar [A platform for XAFS study of dynamically compressed materials above 1 Mbar]

Here, a platform consisting of a multi-shock drive and an implosion backlighter has been developed for x-ray absorption fine structure (XAFS) measurements on materials compressed to multi-Mbar pressures. The experimental setup, target design, and backlighter characteristics are presented. Extended XAFS (EXAFS) measurements for various materials have been demonstrated. A quintuple-crystal design is described to enhance the efficiency of the x-ray spectrometer, enabling observation of very weak EXAFS signals in a single shot.

47 OTHER INSTRUMENTATION↗