Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dwell time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Factors affecting dwell times on digital displaying

A series of exploratory tests were conducted to investigate the effects of advanced display formats and display media on pilot scanning behavior using Langley's oculometer, a desktop flight simulator, a conventional electro-mechanical meter, and various digital displays. The primary task was for the test subject to maintain level flight, on a specific course heading, during moderate turbulence. A secondary task of manually controlling the readout of a display was used to examine the effects of the display format on a subject's scan behavior. Secondary task scan parameters that were evaluated were average dwell time, dwell time histograms, and number of dwells per meter change. The round dial meter demonstrated shorter dwell times and fewer dwells per meter change than the digital displays. The following factors affected digital display scanning behavior: (1) the number of digits; (2) the update rate of the digits; (3) the display media; and (4) the character font. The size of the digits used in these tests (0.28 to 0.50 inches) did not affect scan behavior measures.

Williams, A. J.↗

Modeling of switching regulator power stages with and without zero-inductor-current dwell time

State space techniques are employed to derive accurate models for buck, boost, and buck/boost converter power stages operating with and without zero-inductor-current dwell time. A generalized procedure is developed which treats the continuous-inductor-current mode without the dwell time as a special case of the discontinuous-current mode, when the dwell time vanishes. An abrupt change of system behavior including a reduction of the system order when the dwell time appears is shown both analytically and experimentally.

Lee, F. C.↗

Variance of the Quantum Dwell Time for a Nonrelativistic Particle

Munoz, Seidel, and Muga [Phys. Rev. A 79, 012108 (2009)], following an earlier proposal by Pollak and Miller [Phys. Rev. Lett. 53, 115 (1984)] in the context of a theory of a collinear chemical reaction, showed that suitable moments of a two-flux correlation function could be manipulated to yield expressions for the mean quantum dwell time and mean square quantum dwell time for a structureless particle scattering from a time-independent potential energy field between two parallel lines in a two-dimensional spacetime. The present work proposes a generalization to a charged, nonrelativistic particle scattering from a transient, spatially confined electromagnetic vector potential in four-dimensional spacetime. The geometry of the spacetime domain is that of the slab between a pair of parallel planes, in particular those defined by constant values of the third (z) spatial coordinate. The mean Nth power, N = 1, 2, 3, . . ., of the quantum dwell time in the slab is given by an expression involving an N-flux-correlation function. All these means are shown to be nonnegative. The N = 1 formula reduces to an S-matrix result published previously [G. E. Hahne, J. Phys. A 36, 7149 (2003)]; an explicit formula for N = 2, and of the variance of the dwell time in terms of the S-matrix, is worked out. A formula representing an incommensurability principle between variances of the output-minus-input flux of a pair of dynamical variables (such as the particle s time flux and others) is derived.

Hahne, Gerhard↗

Modeling of switching regulator power stages with and without zero-inductor-current dwell time

State-space techniques are employed to derive accurate models for the three basic switching converter power stages: buck, boost, and buck/boost operating with and without zero-inductor-current dwell time. A generalized procedure is developed which treats the continuous-inductor-current mode without dwell time as a special case of the discontinuous-current mode when the dwell time vanishes. Abrupt changes of system behavior, including a reduction of the system order when the dwell time appears, are shown both analytically and experimentally. Merits resulting from the present modeling technique in comparison with existing modeling techniques are illustrated.

Lee, F. C. Y.↗

A Factorial Data Rate and Dwell Time Experiment in the National Transonic Facility

This report is an introductory tutorial on the application of formal experiment design methods to wind tunnel testing, for the benefit of aeronautical engineers with little formal experiment design training. It also describes the results of a Study to determine whether increases in the sample rate and dwell time of the National Transonic Facility data system Would result in significant changes in force and moment data. Increases in sample rate from 10 samples per second to 50 samples per second were examined, as were changes in dwell time from one second per data point to two seconds. These changes were examined for a representative aircraft model in a range of tunnel operating conditions defined by angles of attack from 0 deg to 3.8 degrees, total pressure from 15.0 psi to 24.1 psi, and Mach numbers from 0.52 to 0.82. No statistically significant effect was associated with the change in sample rate. The change in dwell time from one second to two seconds affected axial force measurements, and to a lesser degree normal force measurements. This dwell effect comprises a "rectification error" caused by incomplete cancellation of the positive and negative elements of certain low frequency dynamic components that are not rejected by the one-Hz low-pass filters of the data system. These low frequency effects may be due to tunnel circuit phenomena and other sources. The magnitude of the dwell effect depends on dynamic pressure, with angle of attack and Mach number influencing the strength of this dependence. An analysis is presented which suggests that the magnitude of the rectification error depends on the ratio of measurement dwell time to the period of the low-frequency dynamics, as well as the amplitude of the dynamics The essential conclusion of this analysis is that extending the dwell time (or, equivalently, replicating short-dwell data points) reduces the rectification error.

DeLoach, R.↗

Cylindrical Optic Figuring and Dwell Time Optimization

Grazing incidence x-ray telescopes consist of surfaces which are nearly cylindrical in shape. The abrasive figuring of these surfaces is accomplished by moving a grinding tool along a helical path on this almost cylindrical surface. The measurement of the surface is, however, performed along "axial" scan lines which intercept this helical path. This approach to figuring and measuring permits a relatively simple scheme to be implemented for the determination of the optimal dwell times of the figuring tool. These optimal dwell times are determined by a deconvolution which approaches the problem in a linear programming context and uses the Simplex Method. The approach maximizes the amount of material removed at any point subject to inequality constraints. The effect of using these ''optimum" dwell times is to significantly improve the tools effectiveness at removing the higher spatial frequencies while staying (strictly) within the bounds and constraints imposed by the hardware. In addition, the ringing at the edges of the optic, frequently present in deconvolution problems, is completely eliminated.

Waluschka, Eugene↗

Cylindrical Optic Polishing Dwell Time Optimization

The Constellation-X x-ray telescope consists of replicated grazing incidence optics. The polishing of the "master' mandrel is accomplished by moving a polishing tool along a helical path on the surface of this almost cylindrical surface. The measurement of the surface is, however, performed along "axial" scan lines which intercept this helical path. This approach to polishing and measuring permits a relatively simple scheme to be implemented for the determination of the optimal dwell times of the polishing tool. These optimal dwell times are determined by a deconvolution which approaches the problem as a linear programming problem and uses the simplex method. This approach maximizes the amount of material removed at any point subject to inequality constraints. The effects of using these "optimum" dwell times is to significantly improve the "tools" effectiveness at removing the higher spatial frequencies while staying (strictly) within the bounds and constraints imposed by the hardware. In addition the "ringing" at the edges of the optic, frequently present in deconvolution problems, is completely eliminated.

Waluschka, Eugene↗

Comparison between variable and fixed dwell-time PN acquisition algorithms

Pseudo noise (PN) spread spectrum systems require a very accurate alignment between the PN code epochs at the transmitter and receiver. This synchronism is typically established through a two-step algorithm, including a coarse synchronization procedure and a fine synchronization procedure. A standard approach for the coarse synchronization is a sequential search over all code phases. The measurement of the power in the filtered signal is used to either accept or reject the code phase under test as the phase of the received PN code. This acquisition strategy, called a single dwell-time system, has been analyzed by Holmes and Chen (1977). A synopsis of the field of sequential analysis as it applies to the PN acquisition problem is provided. From this, the implementation of the variable dwell time algorithm as a sequential probability ratio test is developed. The performance of this algorithm is compared to the optimum detection algorithm and to the fixed dwell-time system.

Braun, W. R.↗

Dwell Time and Surface Parameter Effects on Removal of Silicone Oil From D6ac Steel Using TCA

This study was conducted to evaluate the impact of dwell time, surface roughness, and the surface activation state on 1,1,1-trichloroethane's (TCA's) effectiveness for removing silicone oil from D6ac steel. Silicone-contaminated test articles were washed with TCA solvent, and then the surfaces were analyzed for residue, using Fourier transform infrared spectroscopy. The predominant factor affecting the ability to remove the silicone oil was surface roughness.

Boothe, R. E.↗

Effects of equivalence ratio and dwell time on exhaust emissions from an experimental premixing prevaporizing burner

A flame-tube study was performed to determine the effects of equivalence ratio and residence time on exhaust emissions with premixed, prevaporized propane fuel. Nitrogen oxides emissions as low as .3 g NO2/kg fuel were measured with greater than 99% combustion efficiency at 800 K inlet temperature and an equivalence ratio of .4. For a constant combustion efficiency, lower nitrogen oxides emissions were obtained by burning very lean with relatively long residence times than by using somewhat higher equivalence ratios with shorter times.

Anderson, D.↗

Effects of equivalence ratio and dwell time on exhaust emissions from an experimental premixing prevaporizing burner

A flame-tube study was performed to determine the effects of equivalence ratio and residence time on exhaust emissions with premixed, prevaporized propane fuel. Nitrogen oxides emissions as low as 0.3 g NO2/kg fuel were measured with greater than 99 percent combustion efficiency at 800 K inlet temperature and an equivalence ratio of 0.4. For a constant combustion efficiency, lower nitrogen oxides emissions were obtained by burning very lean with relatively long residence times than by using somewhat higher equivalence ratios with shorter times.

Anderson, D.↗

Flight Deck Interval Management Avionics: Eye-Tracking Analysis

Interval Management (IM) is one NexGen method for achieving airspace efficiencies. In order to initiate IM procedures, Air Traffic Control provides an IM clearance to the IM aircraft's pilots that indicates an intended spacing from another aircraft (the target to follow - or TTF) and the point at which this should be achieved. Pilots enter the clearance in the flight deck IM (FIM) system; and once the TTF's Automatic Dependent Surveillance-Broadcast signal is available, the FIM algorithm generates target speeds to meet that IM goal. This study examined four Avionics Conditions (defined by the instrumentation and location presenting FIM information) and three Notification Methods (defined by the visual and aural alerts that notified pilots to IM-related events). Current commercial pilots flew descents into Dallas/Fort-Worth in a high-fidelity commercial flight deck simulation environment with realistic traffic and communications. All 12 crews experienced each Avionics Condition, where order was counterbalanced over crews. Each crew used only one of the three Notification Methods. This paper presents results from eye tracking data collected from both pilots, including: normalized number of samples falling within FIM displays, normalized heads-up time, noticing time, dwell time on first FIM display look after a new speed, a workload-related metric, and a measure comparing the scan paths of pilot flying and pilot monitoring; and discusses these in the context of other objective (vertical and speed profile deviations, response time to dial in commanded speeds, out-of-speed-conformance and reminder indications) and subjective measures (workload, situation awareness, usability, and operational acceptability).

Latorella, Kara↗

Closed-Loop Chopping-Mirror Controller

Motion of chopping mirror controlled very precisely by feedback circuit originally developed for mirrors in orbiting infrared telescopes. Mirror position and velocity electronically sensed and commanded. New controller enables selection of different chopping frequencies, angular amplitudes, dwell times, and dwell positions. Also reduces noise and vibration by eliminating mechanical stops and reduces energy consumption in actuator.

Lorell, Kenneth R.↗

Select Electronic Parts Operation at Extreme Low Temperature

The purpose of the study presented in this paper is to extend the test period of a selected set of electronics parts at cryogenic condition to dwell period of about 24 hours to demonstrate extreme cold operational capability of these components. The parts tested are tantalum polymer, BX and P90 type ceramic capacitors, thick film resistors, analog multiplexers, a digital inverter, and a D-flip-flop. These parts were tested to assist identifying candidate components that can be used for development of a cold capable telemetry board. There are several past investigations that have shown that COTS (commercial-off-the-shelf) capacitors and resistors tested at cryogenic temperatures and frequencies up to 10MHz did not exhibit significant changes in capacitance and resistance values. Also, there are several test results for active parts. These past tests collected measurements during a temperature sweep from room temperature down to cryogenic temperature with very short dwell time at cryogenic temperature, and back to room temperature. This study extends the operational dwell time to at least 24 hours and returning to room temperature operation without significant degradation in performance, thus, demonstrating the potential for longer dwell time in actual operation in these extreme cold temperatures and a method for identifying the cold operability.

Ashtijou, Mohammad↗

Techniques used for the analysis of oculometer eye-scanning data obtained from an air traffic control display

The methodology and techniques used to collect and analyze look-point position data from a real-time ATC display-format comparison experiment are documented. That study compared the delivery precision and controller workload of three final approach spacing aid display formats. Using an oculometer, controller lookpoint position data were collected, associated with gaze objects (e.g., moving aircraft) on the ATC display, and analyzed to determine eye-scan behavior. The equipment involved and algorithms for saving, synchronizing with the ATC simulation output, and filtering the data are described. Target (gaze object) and cross-check scanning identification algorithms are also presented. Data tables are provided of total dwell times, average dwell times, and cross-check scans. Flow charts, block diagrams, file record descriptors, and source code are included. The techniques and data presented are intended to benefit researchers in other studies that incorporate non-stationary gaze objects and oculometer equipment.

Crawford, Daniel J.↗

Analytical techniques of pilot scanning behavior and their application

The state of the art of oculometric data analysis techniques and their applications in certain research areas such as pilot workload, information transfer provided by various display formats, crew role in automated systems, and pilot training are documented. These analytical techniques produce the following data: real-time viewing of the pilot's scanning behavior, average dwell times, dwell percentages, instrument transition paths, dwell histograms, and entropy rate measures. These types of data are discussed, and overviews of the experimental setup, data analysis techniques, and software are presented. A glossary of terms frequently used in pilot scanning behavior and a bibliography of reports on related research sponsored by NASA Langley Research Center are also presented.

Harris, R. L., Sr.↗

Optical scanning system for laser velocimeter

An optical system was developed to provide fast incremental scanning of a backscattered laser velocimeter focus point over a 36-cm distance. The system is used to measure flow velocities at 16 positions along its optical axis and to scan these 16 positions up to 30 times a second. Dwell time at each location is approximately 2 milliseconds. Sample volumes typically are 0.2 mm in diameter by 1.4 cm in length. The optical scanning system consists of a wheel containing plane parallel quartz windows of various thicknesses. The laser velocimeter beams are imaged to a primary focus within the dead airspace of an optical cell. The beams emerging from the cell pass through the windows of the scanning wheel. The refraction of the beams passing through the windows causes an apparent shift of the focus within the optical cell and hence in the test zone. Light scattered from the secondary focus within the test zone is concurrently collected and reimaged through the same optical path which originally projected the primary focus. The reimaged backscattered light containing the velocity information is then collected and focused onto a photomultiplier detector system to complete the scanned laser velocimeter optical system.

Rhodes, D. B.↗