Parametric evaluation of ducted fuel injection in an optically accessible mixing-controlled compression-ignition engine with two- and four-duct assemblies

Ducted fuel injection (DFI) is a strategy to improve fuel/charge-gas mixing in direct-injection compression-ignition engines. DFI involves injecting fuel along the axis of a small tube in the combustion chamber, which promotes the formation of locally leaner mixtures in the autoignition zone relative to conventional diesel combustion. Previous work has demonstrated that DFI is effective at curtailing engine-out soot emissions across a wide range of operating conditions. This study extends previous investigations, presenting engine-out emissions and efficiency trends between ducted two-orifice and ducted four-orifice injector tip configurations. For each configuration, parameters investigated include injection pressure, injection duration, intake manifold pressure, intake manifold temperature, start of combustion timing, and intake-oxygen mole fraction. For both configurations and across all parameters, DFI reduced engine-out soot emissions compared to conventional diesel combustion, with little effect on other emissions and engine efficiency. Emissions trends for both configurations were qualitatively the same across the parameters investigated. The four-duct configuration had higher thermal efficiency and indicated-specific engine-out nitrogen oxide emissions but lower indicated-specific engine-out hydrocarbon and carbon monoxide emissions than the two-duct assembly. Both configurations achieved indicated-specific engine-out emissions for both soot and nitrogen oxides that comply with current on- and off-road heavy-duty regulations in the United States without exhaust-gas aftertreatment at an intake-oxygen mole fraction of 12%. High-speed in-cylinder imaging of natural soot luminosity shows that some conditions include a second soot-production phase late in the cycle. The probability of these late-cycle events is sensitive to both the number of ducted sprays and the operating conditions.

Yraguen, Boni Frances↗

A computational analysis of effective R-values of buried ducts – the dynamic performance of buried ducts

Here, this paper evaluates the thermal performance of ducts partially or fully buried in loose-fill attic insulation. The overall thermal resistance between the ducts and the attic is referred to as an effective R-value. This paper shows a strong dependency of assumed attic temperature on the effective R-value. Based on the results, the effective R-value can be about twice as much with an attic temperature of 130 °F [54.4 °C], compared to when the attic temperature is 80 °F [26.7 °C]. Thus, this paper provides a polynomial regression equation based on a large set of simulations to determine the effective R-value of buried ducts depending on attic temperature and whether the HVAC system runs in cooling or heating mode. Further, the work presented in this paper investigated the potential impact of convective airflow within the attic insulation, particularly around the ducts. The analysis was based on computational fluid dynamics (CFD) and indicated that convectional forces are presented around the exterior surface of the ducts, but with negligible impact on the overall heat balance between the duct and the attic space.

97 MATHEMATICS AND COMPUTING↗

Determining tolerance requirements for spray-duct alignment in ducted fuel injection

Several ducted fuel injection (DFI) studies have highlighted the importance of accuracy in aligning the duct axis with that of its corresponding spray for optimal effectiveness, as misalignment adversely impacts the method’s performance. The need for accurate alignment could lead to added manufacturing complexity via tighter tolerances. This study systematically explores cases of horizontal, vertical, and rotational misalignment, analyzing their respective effects on DFI performance. Vertical and horizontal misalignments at the duct inlet plane were varied at magnitudes of 6.25%, 12.5%, and 25.0% of the duct diameter, corresponding to 0.125, 0.25, and 0.5 mm, respectively. Rotational misalignments were set at 1°, 2°, and 4°, corresponding to 3.65%, 7.30%, and 14.6%, respectively, of the duct diameter at its inlet plane. The investigation yields spray-duct alignment tolerance limits and highlights the influence of misalignment direction on emissions due to the interactions with swirl and squish inside the combustion chamber. The results indicate that the tolerance limits for the alignment are within 4° and 0.5 mm relative to the geometrically aligned position. If the misalignment exceeds 4°of rotation or 0.5 mm in the horizontal direction, the beneficial effects on soot reduction using this method are no longer observed. The findings contribute to an understanding that can be used to optimize DFI for cleaner and more efficient combustion in compression-ignition engines.

Şener, Ramazan↗

Ducted fuel injection system alignment device

An alignment device for a ducted fuel injection system comprising a mounting block removably attachable to a duct of the ducted fuel injection system. The mounting block can include a passageway extending therethrough. The passageway can align with the duct when the mounting block is attached to the duct. The alignment device further comprises an imaging device configured to capture an image viewing through the duct toward an outlet of a fuel injector. A portion of the imaging device can extend in the passageway. The alignment device additionally comprises a centering structure configured to align a portion of the imaging device with a central axis of the duct. The image captured by the imaging device can be configured for use aligning a position of an outlet of a fuel injector with respect to a position of the duct.

Nilsen, Christopher William↗

Moisture Performance of Unvented Attics With Vapor Diffusion Ports and Buried Ducts in Hot, Humid Climates

Energy efficiency measures, such as cool roofs, radiant barriers, interior radiative control coatings, and buried ducts are increasing in popularity and are promoted by energy codes because of their energy-saving potential. However, these strategies can also pose moisture risks in attics by lowering surface temperatures and increasing condensation potential and moisture accumulation. Of particular concern in hot-humid climates is dripping condensation on cold air-conditioning ductwork in the summer - commonly referred to as duct "sweating" - which threatens the attic floor with conditions conducive to mold growth and rot. One strategy to mitigate these moisture issues is to wrap ductwork in thicker duct-wrap insulation with an integrated exterior vapor barrier, but thick duct wrap can be difficult to come by, expensive, and unwieldy to work with. This study explores an alternative strategy of reducing moisture issues while embracing energy efficiency by using unvented attics with vapor diffusion ports and buried ductwork in hot-humid climates. Vapor diffusion ports have been studied so far in a wide range of U.S. climates, mostly in the context of conditioned attics. In this study, the strategy is implemented in the novel context of hot-humid climates with ductwork sitting atop blown-in attic floor insulation in unconditioned attics. Using a combination of field experiments and hygrothermal modeling, the findings of this project indicate that an unvented attic with vapor diffusion ports and buried ducts may be a key part of a successful low-cost method for reducing the attic moisture load by venting excess moisture out of the attic, keeping duct-jacket surfaces above dew point temperature, and keeping the roof deck safe from winter moisture accumulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Differentiated mouse kidney tubuloids as a novel in vitro model to study collecting duct physiology

Kidney tubuloids are cell models that are derived from human or mouse renal epithelial cells and show high similarities with their in vivo counterparts. Tubuloids grow polarized in 3D, allow for long-term expansion, and represent multiple segments of the nephron, as shown by their gene expression pattern. In addition, human tubuloids form tight, functional barriers and have been succesfully used for drug testing. Our knowledge of mouse tubuloids, on the other hand, is only minimal. In this study, we further characterized mouse tubuloids and differentiated them towards the collecting duct, which led to a significant upregulation of collecting duct-specific mRNAs of genes and protein expression, including the water channel AQP2 and the sodium channel ENaC. Differentiation resulted in polarized expression of collecting duct water channels AQP2 and AQP3. Also, a physiological response to desmopressin and forskolin stimulation by translocation of AQP2 to the apical membrane was demonstrated. Furthermore, amiloride-sensitive ENaC-mediated sodium uptake was shown in differentiated tubuloids using radioactive tracer sodium. This study demonstrates that mouse tubuloids can be differentiated towards the collecting duct and exhibit collecting duct-specific function. This illustrates the potential use of mouse kidney tubuloids as novel in vitro models to study (patho)physiology of kidney diseases.

59 BASIC BIOLOGICAL SCIENCES↗

Aerosol-Based Sealant for Air Ducts Technology

Aerosol-based sealant can be used to seal air duct leaks. This is done by pressurizing the ducts and injecting the spray sealant. This technology can be used to seal small (up to ½-inch diameter) and inaccessible duct leaks hidden in wall, ceiling, and floor cavities (Ternes and Hwang2001). The aerosol sealant itself is a nontoxic vinyl polymer (Kallett et al. 2000). The technology is a proprietary duct-sealing method developed jointly by the U.S. government and Aeroseal, the company that holds an exclusive license to use the technology (Ternes and Hwang 2001). Specifically, Lawrence Berkeley National Laboratory developed the aerosol-spray technology with funding from the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency, and others while Aeroseal developed the current version of the equipment and software to apply the technology in practice (Ternes and Hwang 2001).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RAFT: Reconfigurable Array of High-Efficiency Ducted Turbines for Hydrokinetic Energy Harvesting

Diversifying the energy harvesting portfolio is crucial to achieving the ambitious goal of transitioning to clean energy by 2030. Marine hydrokinetic energy has garnered renewed interest due to its high harvesting potential in the U.S., and the resource's reliability and predictability—remaining relatively constant on a daily basis and available 24/7. However, there are currently few commercial devices capable of harnessing the energy from flowing water. This project aims to bridge that gap by designing and evaluating a novel hydrokinetic turbine concept that can efficiently harvest energy from both rivers and tidal streams. The RAFT (Reconfigurable Array of High-Efficiency Ducted Turbines) concept introduces a duct surrounding the turbine rotor and creates an array of small 5-kW units. The duct serves two primary purposes: (1) it enhances hydrodynamic efficiency by accelerating flow to the rotor, and (2) it functions as a structural component, facilitating the formation of modular arrays that lower costs. This project focuses on demonstrating this concept and validating these benefits through simulations and scaled prototype testing. The project team includes 8 faculty members and over 20 students from 3 universities, organized into three core areas: hydrodynamics, electrical systems, and structural analysis, with additional teams dedicated to system integration, environmental assessment and risk management, and tech-to-market strategy. The team successfully demonstrated the increased hydrodynamic efficiency of a ducted turbine compared to an unducted version using high-fidelity simulations and prototype tests. Moreover, design optimization efforts led to surpassing the SHARKS program's goal of 60% reduction of the levelized cost of energy with a significant margin.

13 HYDRO ENERGY↗

CFD-based design optimization of ducted hydrokinetic turbines

Abstract Hydrokinetic turbines extract kinetic energy from moving water to generate renewable electricity, thus contributing to sustainable energy production and reducing reliance on fossil fuels. It has been hypothesized that a duct can accelerate and condition the fluid flow passing the turbine blades, improving the overall energy extraction efficiency. However, no substantial evidence has been provided so far for hydrokinetic turbines. To investigate this problem, we perform a CFD-based optimization study with a blade-resolved Reynolds-averaged Navier–Stokes (RANS) solver to explore the design of a ducted hydrokinetic turbine that maximizes the efficiency of energy extraction. A gradient-based optimization approach is utilized to effectively deal with the high-dimensional design space of the blade and duct geometry, with gradients being calculated through the adjoint method. The final design is re-evaluated through higher-fidelity unsteady RANS (URANS) simulations. Our optimized ducted turbine achieves an efficiency of about 54% over a range of operating conditions, higher than the typical 46% efficiency of unducted turbines.

13 HYDRO ENERGY↗

Analysis of ducted fuel injection at high-pressure transcritical conditions using large-eddy simulations

Ducted fuel injection (DFI) is a proposed fuel injection concept for achieving substantial reductions in emissions. In this concept, the fuel is injected through a coannular duct, resulting in increased fuel-air mixing and minimized formation of soot and other unwanted combustion products. Apart from comprehensive experimental investigations on DFI, so far computational studies have been limited to single-point Reynolds-averaged Navier Stokes simulations. Therefore, the objective of this work is to complement these studies by performing large-eddy simulations using a diffuse-interface method to examine the physical mechanisms and combustion processes of DFI, specifically focusing on the mixing process and the effect of fuel-ducting on combustion and pollutant emissions. To this end, finite-rate chemistry simulations are performed of the DFI configuration corresponding to the Engine Combustion Network Spray A injector at transcritical conditions (n-dodecane fuel, 60 bar pressure and 1000 K temperature chamber conditions). A two-equation soot model is employed for the qualitative analysis of soot emissions. Direct comparisons of averaged and instantaneous flow field results with the Spray A configuration are performed to assess the effect of DFI on the first- and second-stage ignition and soot formation. Compared to the free-spray condition, the results show that the DFI case exhibits a combination of (i) increased mass flow rate and entrained air, (ii) larger pressure drop magnitude and flow velocity, and (iii) a closer-to-stoichiometric mixture composition (both globally and locally), each of which is conjectured to contribute toward reduced soot production.

33 ADVANCED PROPULSION SYSTEMS↗

Hydrogen Storage for Load-Following and Clean Power: Duct-firing of Hydrogen to Improve the Capacity Factor of NGCC Plants (Final Report, Phase II Pre-Front End Engineering Design Study)

GTI Energy (GTI) and team members Southern Company Services (SCS), Pacific Gas & Electric (PG&E) and the Electric Power Research Institute (EPRI) performed a Phase II Pre-Feed Study under contract DE-FE0032008 for Hydrogen Storage for Load-Following and Clean Power. The configuration of the proposed system consists of subsystems for on-site H 2 production, on-site H 2 storage (up to 54 MWth in commercial vessels) and H 2 combustion in a duct burner in a Heat Recovery Steam Generator (HRSG) integrated with an existing fossil asset. Here, the firing rate of the duct burner is varied to let the plant respond to fluctuations of electrical load and H 2 production is relatively constant by storing H 2 . The proposed system is an improvement over alternate low carbon dispatchable power options. Technoeconomic analyses show H 2 produced with GTI’s patented Compact Hydrogen Generator (CHG) with inherent carbon capture will be lower cost (Levelized Cost of Hydrogen, LCOH) relative to hydrogen produced with a Steam Methane Reformer (SMR) with an amine system for carbon capture. This lower cost hydrogen enables our integrated system to deliver electricity (Levelized Cost of Electricity, LCOE) at 17.4% lower cost relative to a SMR sourced H 2 -fired HRSG (with an amine system for carbon capture) – Steam Turbine Generator (STG). Our analysis using EPRI’s US REGEN macroeconomic model shows our system will have significant demand in the power market and therefore require significant capacity expansion (CHG plants built to deliver hydrogen) to deliver low cost, low carbon power. In Phase II, our Team has completed a detailed system definition including the development of process models, definition of battery limits, Process Flow Diagrams (PFDs), Piping and Instrumentation Drawings (P&IDs), and a plant layout. A preliminary design for the key components of the CHG was developed including component lists & specifications. An evaluation of environmental and permitting considerations was completed and included the development of an Environmental Information Volume (EIV). The duct burners, which are flexible and can burn hydrogen and/or natural gas, were defined and initial CFD analyses were completed.

03 NATURAL GAS↗

Tensile properties of the neutron irradiated HT-9 ACO-3 duct

HT-9, a ferritic-Martensitic steel, has attracted significant interest as a structural and cladding material for a variety of high dose nuclear component applications. This study examines the tensile properties of a HT-9 fuel assembly duct from the fast flux test facility, FFTF. The duct, from the Advanced Core Oxide-3 (ACO-3) irradiation test, was subjected to fast neutron irradiation exposure ranging from 3 dpa above the core top to nearly 155 dpa near the core mid-plane, spanning a temperature range from 382 °C at the lower end to 504 °C at the top. Due to the combination of thermal and neutron flux gradients along the core height. This yields a variety of irradiation damage processes which depend on core location. Tensile properties of specimens extracted at different positions along the height of the irradiated duct were measured at 25 °C, 200 °C and near their in-core irradiation temperature. The results show temperature has a greater impact than dose on post-irradiation strength and ductility. Two irradiation temperature regimes were determined, below irradiation temperatures of 420 °C irradiation hardening increases as irradiation temperature decreases, and above that temperature relatively minor changes are observed in tensile properties. These results are discussed in terms of expected microstructural changes, indicating that dislocation content is a strong contributor in these findings.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hydrogen Storage for Load-Following and Clean Power: Duct-firing of Hydrogen to Improve the Capacity Factor of NGCC Plants (Final Report, Phase I Conceptual Study)

The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and the proposed system is an improvement over alternate low carbon dispatchable power options. Our demonstration will include 54 MWh of hydrogen storage. CO 2 capture inherent to the CHG process can capture 90% of the CO 2 (with upgrades to >98%) in a commercial system (~300 MWth) for sequestration or other uses. The hydrogen will be utilized in a duct burner in a Heat Recovery Steam Generator (HRSG) integrated with the existing Southern Company fossil asset. Here, the firing rate of the duct burner is varied to let the plant respond to fluctuations of electrical load. However, H 2 production is relatively constant by storing H 2 , and revenues are improved by arbitrage between use of low-cost off-peak variable electricity generation or use of stored H 2 under peak demand. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via system requirements review with the whole team. These requirements were then incorporated into/iterated with our Heat & Mass Balance models and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Our system generates power at 17.4% lower cost than other low carbon approaches for the H 2 generation, H 2 compression and storage, carbon sequestration, and HRSG added electricity production for a large-scale duct-fired system. Our team recommends completing the Phase II Pre-FEED study for the proposed system as the next step for the project and its tasks will achieve the overall objective and be ready to launch the FEED. The Pre-FEED tasks include updating the requirements, Concept of Operations, plant scope/process description, component modeling, system modeling, performance estimates, emission estimates, block flow diagrams, fluid/process conditions (PFD), utility usage, and facility sizing/definition. The approach will be to complete these updates in a greater level of detail for the selected site. The approach for developing the EIV is to use the updated results, including model outputs, for carbon dioxide and waste streams.

03 NATURAL GAS↗

Summary of Stack Tests at TA-16-Bldg 205: Horizontal Duct on WETF Roof

In late 2023 and early 2024, testing was done at the Weapons Engineering Tritium Facility (WETF) rooftop exhaust duct to verify that the stack sample location was in compliance with the ANSI standard for stack sampling, ANSI N13.1-1999. This ANSI standard is called out by the Clean Air Act rules for airborne radionuclide emissions from DOE facilities, 40 CFR 61 Subpart H. This sample location is designated 16020504, indicating Technical Area 16, Building 0205. The rooftop duct formerly discharged to Exhaust Stack 04, but in 2007 it was re-routed to exhaust out Building 0450, Exhaust Stack 05. For continuity, we have kept the 16020504 designation to represent this duct sample location.

54 ENVIRONMENTAL SCIENCES↗

Numerical study on aerosol sampling in a nuclear facility duct with a 90-degree elbow

Due to the challenging design requirements, elbows are often unavoidable in duct configuration, and these 90-degree bends introduce swirl, velocity variations, recirculation, and secondary flow. These disturbances make it difficult for nuclear facilities to meet particle sampling standards. A series of numerical analyses are conducted to track aerosols in a nuclear facility duct having a 90-degree elbow with the assistance of computational fluid dynamics (CFD). A turbulence model, a continuity, and a momentum, a discrete phase model, and species transport equations are solved simultaneously to track aerosols in the duct. The effect of turbulence models, turbulent dispersion models, droplet drag model, aerosol amount, aerosol spray configuration, guide vanes, and mixers are investigated. Simulation results are analyzed per relevant testing codes such as DOE-HDBK-1169, ASME AG1, ISO 14644-3, ACGIH, and ANSI/HPS N13.1.

Han, Kai [Savannah River Nuclear Solutions (SRNS),↗

A computational parametric study of ducted fuel injection implementation in a heavy-duty diesel engine

Experiments have shown that ducted fuel injection (DFI) effectively reduces soot emissions from direct-injection diesel engines. Although many computational studies have evaluated DFI’s spray development and soot reduction mechanisms in constant volume chambers, only limited computational work on internal combustion engines exists. The DFI duct assembly changes the engine’s in-cylinder flow, spray, and combustion development. Therefore, current production engine designs might not be optimal for achieving the best engine performance with DFI. Here, this work conducted an extensive numerical study to evaluate how parameter changes affect DFI performance. The parameters include swirl ratio, piston geometry, compression ratio (CR), number of injector orifices, split injection strategy, and exhaust gas recirculation (EGR) in a heavy-duty diesel engine utilizing DFI. The combustion and soot emission data from the Sandia compression ignition optical research engine were used for model validation. Simulations showed that an increased swirl ratio resulted in more intense jet flame-piston interaction, slowing down the combustion heat release during the late combustion stage and leading to lower indicated thermal efficiency (ITE) due to higher exhaust losses. A piston-bowl design with a reentrant inner piston edge yielded the highest thermal efficiency, due to the reduced cylinder head heat transfer loss. Additional injector orifices led to higher efficiency owing to a more advanced combustion phasing. Nevertheless, the maximum pressure rise rate (MPRR) and oxides of nitrogen (NO x ) emissions also increased with the number of injector orifices due to more rapid heat release and higher combustion temperature. Implementation of a split injection strategy combined with a higher EGR rate effectively inhibited the excessive MPRR and NO x formation. In general, the study concluded that DFI is not sensitive to most parameter changes but will benefit from future parameter optimization.

33 ADVANCED PROPULSION SYSTEMS↗

Flow friction in a wide rectangular duct with a beveled inlet: Informal Notes of Fundamental Fluid Physics Studies

Fundamental streamwise pressure distributions were measured at Idaho State University to address a primary objective of obtaining insight into the apparent evolution of air flow regimes at moderate Reynolds numbers in thin, wide rectangular ducts with converging inlets. Ducts of 3.030 and 4.077 mm spacings s (called three and four mm), having non-dimensional lengths of (L/s) ≈ 500.8 and 372.2 and widths (W/s) ≈ 114.6 and 83.2, respectively, were compared. Flow rates ranged from Reynolds numbers based on hydraulic diameter (Re Dh ) of about 980 to 10,000 and corresponding non-dimensional downstream pressure gradient parameters (-K p ) covered the range 0.038 to 0.0061, respectively.