Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dual imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Beamline K11 DIAD: a new instrument for dual imaging and diffraction at Diamond Light Source

The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is a new dual-beam instrument for full-field imaging/tomography and powder diffraction. This instrument provides the user community with the capability to dynamically image 2D and 3D complex structures and perform phase identification and/or strain mapping using micro-diffraction. The aim is to enable in situ and in operando experiments that require spatially correlated results from both techniques, by providing measurements from the same specimen location quasi-simultaneously. Using an unusual optical layout, DIAD has two independent beams originating from one source that operate in the medium energy range (7–38 keV) and are combined at one sample position. Here, either radiography or tomography can be performed using monochromatic or pink beam, with a 1.4 mm × 1.2 mm field of view and a feature resolution of 1.2 µm. Micro-diffraction is possible with a variable beam size between 13 µm × 4 µm and 50 µm × 50 µm. One key functionality of the beamline is image-guided diffraction, a setup in which the micro-diffraction beam can be scanned over the complete area of the imaging field-of-view. This moving beam setup enables the collection of location-specific information about the phase composition and/or strains at any given position within the image/tomography field of view. The dual beam design allows fast switching between imaging and diffraction mode without the need of complicated and time-consuming mode switches. Real-time selection of areas of interest for diffraction measurements as well as the simultaneous collection of both imaging and diffraction data of (irreversible) in situ and in operando experiments are possible.

36 MATERIALS SCIENCE↗

Dual-Image Color Normalization to Enable High-Performance Concentrating Solar Optical Metrology

Concentrating Solar Power (CSP) requires precision mirrors, and these in turn require metrology systems to measure their optical slope. In this project we studied a color-based approach to the correspondence problem, which is the association of points on an optical target with their corresponding points seen in a reflection. This is a core problem in deflectometry-based metrology, and a color solution would enable important new capabilities. We modeled color as a vector in the [R,G,B] space measured by a digital camera, and explored a dual-image approach to compensate for inevitable changes in illumination color. Through a series of experiments including color target design and dual-image setups both indoors and outdoors, we collected reference/measurement image pairs for a variety of configurations and light conditions. We then analyzed the resulting image pairs by selecting example [R,G,B] pixels in the reference image, and seeking matching [R,G,B] pixels in the measurement image. Modulating a tolerance threshold enabled us to assess both match reliability and match ambiguity, and for some configurations, orthorectification enabled us to assess match accuracy. Using direct-direct imaging, we demonstrated color correspondence achieving average match accuracy values of 0.004 h, where h is the height of the color pattern. We found that wide-area two-dimensional and linear one-dimensional color targets outperformed hybrid linear/lateral gradient targets in the cases studied. Introducing a mirror degraded performance under our current techniques, and we did not have time to evaluate whether matches could be reliably achieved despite varying light conditions. Nonetheless, our results thus far are promising.

14 SOLAR ENERGY↗

Integrated Dual Imaging Detector

A new type of image detector was designed to simultaneously analyze the polarization of light at all picture elements in a scene. The integrated Dual Imaging detector (IDID) consists of a lenslet array and a polarizing beamsplitter bonded to a commercial charge coupled device (CCD). The IDID simplifies the design and operation of solar vector magnetographs and the imaging polarimeters and spectroscopic imagers used, for example, in atmosphere and solar research. When used in a solar telescope, the vector magnetic fields on the solar surface. Other applications include environmental monitoring, robot vision, and medical diagnoses (through the eye). Innovations in the IDID include (1) two interleaved imaging arrays (one for each polarization plane); (2) large dynamic range (well depth of 10(exp 5) electrons per pixel); (3) simultaneous readout and display of both images; and (4) laptop computer signal processing to produce polarization maps in field situations.

Rust, David M.↗

Anisotropic neutron response of trans-stilbene and impact on a handheld dual particle imager

Here this manuscript details measurements of the anisotropic light-output response of trans-stilbene, henceforth referred to as stilbene, along the three primary crystal planes and analyzes how this anisotropic response impacts neutron image reconstruction in a handheld dual particle imager (H2DPI). A prototype H2DPI composed of stilbene pillars (6 x 6 x 50 mm 3 ) coupled to silicon photomultipliers was built and is capable of imaging both fast neutrons and gamma rays from kilogram quantities of special nuclear material. Stilbene was chosen as the scintillating medium for the imager because of its pulse shape discrimination capability, time resolution and relatively high light output. A drawback to using stilbene, however, is the anisotropic response. A recoiling proton from a neutron elastic-scattering event in stilbene will yield different amounts of scintillation light depending on the direction of the recoiling proton with respect to the crystal lattice. This manuscript analyzes how this anisotropic response impacts neutron image reconstruction in 4π. The light output in the three primary crystal planes of stilbene were independently measured 6–7 times for proton recoil energies ranging from 0.5–5.0 MeV using a quasi-monoenergetic time-of-flight neutron source. The measured light-output data in the three crystal planes were fit with a semi-empirical function based on Birks’ formula. These fits were used to reconstruct the location of a 252 Cf source in front of the imager (0°, -0.8°), to the left of the imager (-90°, -0.8°) and directly above the imager (0°, 90°) to determine if it is necessary to apply the directionally-dependent response of stilbene to accurately reconstruct source locations. A bootstrapping technique was applied to the measured data sets to produce 1000 images composed of 2000 cone projections for each source location and each measured light-output curve. List-mode maximum likelihood expectation maximization was applied to each image; the highest pixel location and the full width at half maximum (FWHM) were then recorded. The average and standard deviations of these parameters were taken for each set of images. The maximum difference in the average azimuthal pixel location when varying between the appropriate and incorrect light-output curves for the source locations at (0°, -0.8°) and (-90°, -0.8°) were respectively found to be 1.85 ± 1.39° and 2.03 ± 1.78°. All other pixel locations and FWHMs were within a single standard deviation of uncertainty. Taken together, the anisotropic response of stilbene has negligible impact on the neutron image reconstruction capability of the H2DPI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation-V dual-Purkinje-image eyetracker

Major advances characterize the Generation-V dual-Purkinje-image eyetracker compared with the Generation-III version previously described. These advances include a large reduction in size, major improvements in frequency response and noise level, automatic alignment to a subject, and automatic adjustment for different separation between the visual and optic axes, which can vary considerably from subject to subject. In a number of applications described in the paper, the eyetracker is coupled with other highly specialized optical devices. These applications include accurately stabilizing an image on a subject's retina; accurately simulating a visually dead retinal region (i.e., a scotoma) of arbitrary shape, size, and position; and, for clinical purposes, stabilizing the position of a laser coagulator beam on a patient's retina so that the point of contact is unaffected by the patient's own eye movements.

Crane, H. D.↗

A high-speed, dual-CCD imaging photometer

The SNAPSHOT is a high-speed, dual-CCD imaging photometer, with special capability for occultation observations. It is capable of recording occultation light curves in the presence of bright, nonuniform background illumination, such as occultations of stars by Saturn's rings or by comets. Such events are difficult or impossible to observe with conventional photometers. The fundamental idea that makes high time-resolution observations possible is to reduce the data rate by digitizing only those pixels in subframes containing the objects of interest.

Dunham, E. W.↗

Dual particle imaging: Applications in security and environmental imaging

Radiation imaging detectors have been applied in a variety of fields for detection, localization and characterization of radioactive sources. In this work, we describe a handheld detection system (H2DPI) that can simultaneously image neutrons and gamma rays, and reconstruct the energy spectra of the incident particles. This system was applied to the detection and characterization of a plutonium metal source in experiments performed at the National Criticality Experiments Research Center, where the 4.5 kg plutonium source was placed approximately 60 cm from the H2DPI. Neutron and gamma-ray images were measured that show good agreement with the known location of the source. Furthermore, the H2DPI was also used to measure the neutron spectrum, which shows the expected shape of a Watt fission spectrum, and the gamma-ray energy spectrum, which shows the energies common to plutonium metal. Finally, we describe the application of the H2DPI in augmented reality, whereby real-time neutron and gamma-ray imaging data can be streamed to the Microsoft HoloLens to allow the user to visualize the source locations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual particle imaging using time-of-flight neutron classification

Fast-neutron imaging technology is well-suited for passive nuclear material monitoring, secondary inspection of flagged cargo, and wide-area search for lost neutron sources. However, imaging systems that use pulse shape discrimination for event classification require complex pulse waveform analysis. In this work, we evaluate time-of-flight (TOF) based particle classification as an alternative solution for fast-neutron imaging by classifying all events with a TOF above a maximum threshold as neutrons. We measured a Cf-252 source next to Cs-137 using a 12-bar organic-glass scintillator array. By varying the TOF thresholds for neutron identification, we demonstrate a clear trade-off between event yield and backprojection image fidelity, with stricter thresholds improving precision at the cost of statistics, TOF thresholded data generated an image that predicted the neutron source direction with 20% reduced mean central angle prediction error compared to a traditional pulse shape discrimination (PSD) method with comparable event count. Time-of-flight particle classification shows promise as an alternative to pulse shape discrimination systems for fast neutron imaging systems looking to minimize costs and size of electronics with comparable imaging quality. The sources used demonstrate that the method is effective in classifying measured neutrons in a measurement environment with 150 μCi Cs-137 and 1.6 × 10 6 n/s Cf-252 sources positioned at distances of 66 cm and 81 cm from the detector. Additionally, the method classifies low-energy neutron events that pulse shape discrimination removes, so a combination of both methods would result in a higher overall neutron event efficiency.

Heriot, William [Univ. of Michigan, Ann Arbor, MI ↗