Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dual frequency comb spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Dual-frequency-comb UV spectroscopy with one million resolved comb lines

We present high-resolution dual-comb spectroscopy across two broad UV spectral regions spanning 372–410 nm and 325–342 nm. This is achieved by generating sixth and seventh harmonics, respectively, from a low-noise 2.35 µm Cr:ZnS dual-comb laser system. The sixth harmonic band contains approximately 1,000,000 spectrally resolved comb lines, while the seventh harmonic band—around 550,000 comb lines. With the line spacing of 80 MHz, this corresponds to a resolving power of up to 10 million, offering remarkable spectral resolution.

Muraviev, Andrey↗

Dual-comb spectroscopy in the deep ultraviolet

This Letter reports dual-frequency-comb spectroscopy in the deep ultraviolet used to characterize transient laser-produced plasmas. Dual-comb spectroscopy at these wavelengths enables access to a large number of strong electronic transitions in neutral and ionized atoms and molecules. This broadband dual-frequency-comb system at 265 nm measures multiple transitions in neutral and singly ionized iron atoms in a laser-produced plasma. Analysis of absorption spectra yields time-resolved ion and neutral column densities, excitation temperatures, and electron densities, which are measured down to 10 14 cm —3 levels. The results provide insights into low-temperature plasma properties.

47 OTHER INSTRUMENTATION↗

Vertical column dual-comb spectroscopy to a TBS

Open-path dual-frequency-comb spectroscopy (DCS) is a broadband, high spectral resolution, and high precision method for measuring gas concentrations over kilometer-scale paths. It has been used for detection and quantification of emissions of pollutants, hazardous gasses, and greenhouse gasses (GHGs). DCS has been shown to measure trace-gas mixing ratios with 0.14%-0.4% agreement between instruments. To achieve high signal-to-noise ratios (SNRs) with DCS, comb light is targeted onto a retroreflector at the end of the measurement path, which returns the signal to a detector co-located with the launch signal. Installing the retroreflector on a mobile platform such as a balloon or unmanned aerial vehicle (UAV) extends the capabilities of DCS by enabling variable path lengths, greater mobility, and access to higher altitudes. Mobile-target DCS has many uses in plume and leak detection, emissions modeling, and planetary boundary layer (PBL) studies. It is a promising method for observing vertical distributions of GHGs and mixing processes in the PBL, which are difficult to measure but important for pollution and climate monitoring as well as for understanding transport of gasses through the atmosphere. Tethered balloons are an intriguing platform because they enable longer flight durations and higher altitudes than easily obtainable with a UAV and thus allow for column measurements up to and above the PBL. New measurements completed in October/November 2024 reach the highest altitudes above ground level yet achieved by mobile-target DCS. For these measurements, the retroreflector was mounted on a 7 m diameter tethered helium balloon. An actively tracking gimbal on the ground holds the DCS launch telescope and keeps the 5 cm beam pointed onto the retroreflector while the balloon is lifted, lowered, and moved by wind and turbulence.

atmosphere↗

Longwave infrared (6.6–11.4 µm) dual-comb spectroscopy with 240,000 comb-mode-resolved data points at video rate

Using sub-3-cycle pulses from mode-locked Cr:ZnS lasers at λ ≈ 2.4 µm as a driving source, we performed high-resolution dual-frequency-comb spectroscopy in the longwave infrared (LWIR) range. A duo of highly coherent broadband (6.6–11.4 µm) frequency combs were produced via intrapulse difference frequency generation in zinc germanium phosphide (ZGP) crystals. Fast (up to 0.1 s per spectrum) acquisition of 240,000 comb-mode-resolved data points, spaced by 80 MHz and referenced to a Rb clock, was demonstrated, resulting in metrology grade molecular spectra of N 2 O (nitrous oxide) and CH 3 OH (methane). The key to high-speed massive spectral data acquisition was low intensity and phase noise of the LWIR combs and high (7.5%) downconversion efficiency, resulting in a LWIR power of 300 mW for each comb.

Vasilyev, Sergey (ORCID:0000000225203547)↗

Dual-Comb Spectroscopy to Tethered Balloon System (DCS to TBS) Field Campaign Report

There is a critical need for the ability to detect, quantify, and attribute sources and sinks of greenhouse gases (GHGs) with high temporal and spatial resolution. Current methods are typically based on continuously operating near-surface point sensors or intermittent aerial/satellite observations. Dual optical frequency comb spectroscopy (“dual-comb spectroscopy”; DCS) is a laser-based technique that can bridge this sensing gap by providing high-precision, high-accuracy, and high-temporal-resolution detection and quantification of trace gases over kilometer-length scales, connecting local and regional observations. A single DCS system can also provide spatial resolution for source/sink attribution with the addition of a few minor optical elements, enabling cross-validation of other observations (e.g., Total Carbon Column Observing Network [TCCON], Orbiting Carbon Observatory [OCO-2/3], Greenhouse Gases Observing Satellite [GOSAT-1/2][).

54 ENVIRONMENTAL SCIENCES↗

Temporal Variability of Emissions Revealed by Continuous, Long-Term Monitoring of an Underground Natural Gas Storage Facility

Temporal variability contributes to uncertainty in inventories of methane emissions from the natural gas supply chain. Extrapolation of instantaneous, “snapshot-in-time” measurements, for example, can miss temporal intermittency and confound bottom-up/top-down comparisons. Importantly, no continuous long-term datasets record emission variability from underground natural gas storage facilities despite substantial contributions to sector-wide emissions. We present 11 months of continuous observations on a section of a storage site using dual-frequency comb spectroscopy (DCS observing system) and aircraft measurements. Here, we find high emission variability and a skewed distribution in which the 10% highest 3 h emission periods observed by the continuous DCS observing system comprise 41% of the total observed 3-hourly emissions. Monthly emission rates differ by >12×, and 3-hourly rates vary by 17× in 24 h. We find links to the operating phase of the facility—emission rates, including as a percentage of the total gas flow rate, are significantly higher during periods of injection compared to those of withdrawal. We find that if a high frequency of aircraft flights can occur, then the ground- and aircraft-based approaches show excellent agreement in emission distributions. A better understanding of emission variability at underground natural gas storage sites will improve inventories and models of methane emissions and clarify pathways toward mitigation.

54 ENVIRONMENTAL SCIENCES↗

Systems and methods for dual comb spectroscopy

A frequency-measurement method uses a dual frequency-comb spectrometer as an optical wavemeter to measure the frequency of a reference laser that is used to frequency-stabilize the spectrometer. The method includes measuring a walking rate of center bursts in a sequence of interferograms recorded by the spectrometer, determining a number of teeth in each of a plurality of Nyquist windows formed by the dual frequency-comb spectrometer, and determining a Nyquist number of the one Nyquist window covering the laser frequency. The reference laser frequency can then be determined from the number of teeth in each Nyquist window, the Nyquist number, and the comb spacing of either one of the two frequency combs of the dual frequency-comb spectrometer. The reference laser frequency does not need to be measured with a separate wavemeter, or calibrated with respect to a known atomic or molecular transition.

Rieker, Gregory B.↗

Frequency Comb-Based Remote Methane Observation Network (Final Scientific/Technical Report)

ARPA-E investment in long-range, frequency comb-based methane detection has resulted in the first scalable, cost-effective continuous methane emissions system. At the onset of this ARPA-E MONITOR award, the dual-frequency comb spectrometer was a sprawling, expensive, laboratory-confined device which had only recently been demonstrated capable of measuring atmospheric trace gases over open-paths. Bringing the technology to the point of being able to monitor for and characterize methane emissions at oil and natural gas production facilities seemed an almost impossible task. Over the subsequent months and years, our team transitioned the Nobel-prize-winning frequency-comb-laser spectrometer technology to a field-deployed regional methane leak detection system. The spectrometer enables highly sensitive near-infrared absorption measurements of methane along kilometer-scale laser beam paths. The measurements are coupled with an atmospheric modeling and inversion framework to triangulate the location of emission sources and quantify the emission rates.

03 NATURAL GAS↗

Abstract for CRADA between National Energy Technology Laboratory and TOPTICA Photonics, Inc.

The National Energy Technology Laboratory (NETL) and Toptica Photonics (Participant) will collaborate to demonstrate the application of a frequency-comb laser (dual-comb spectroscopy) in an optically accessible rotating detonation engine (RDE). RDEs are a next-generation energy conversion technology which are well-suited to hydrogen usage and have the potential to significantly increase the efficiency of gas turbine engine power cycles. However, critical information is needed about the high temperature and pressure detonation wave, which represents an extremely challenging diagnostic environment. Dual-comb spectroscopy can be used to characterize the pressure-broadened IR absorption features at MHz rates, providing information not possible with conventional tunable diode laser (TDL) technologies. This collaboration will, for the first time, demonstrate application of dual-comb spectroscopy within the combustion annulus of a hydrogen-air RDE. If successful, the data generated will help to accelerate commercialization of RDE technologies in support of decarbonizing our nation’s energy sector.

08 HYDROGEN↗

Waveguiding and Dispersion Properties of Interband Cascade Laser Frequency Combs

Mid-infrared semiconductor lasers have emerged as indispensable compact coherent sources for military and commercial applications. While much of the historical emphasis has been on maximizing the output power and/or spectral purity, a recent new focus has been on engineering these lasers to operate as optical frequency combs (OFCs) for broadband real-time spectroscopy. In particular, the combination of low-drive-power and broad gain bandwidth has made interband cascade laser (ICL) OFCs an attractive complement to quantum cascade laser OFCs operating at longer wavelengths. Moreover, ICL combs can potentially be incorporated into fully-integrated dual-comb spectrometers that employ fast, room-temperature IC photodetectors processed on the same chip.However, the high refractive index of the ICL’s GaSb substrate poses some challenges to the optical waveguiding. Because the modal index is considerably lower than that of the substrate, the optical field can penetrate the bottom cladding layer and leak into the GaSb, inducing wavelength-dependent interference that modifies the gain and group velocity dispersion (GVD) profiles. Even when the effect on lasing threshold is small, the comb properties can be adversely affected. Using the sub-threshold Fourier transform technique, we studied ICL combs with various ridge widths, substrate thicknesses, and center wavelengths. This allowed us to evaluate the effects of modal leakage on the GVD. We find that the resonant nature of the substrate modes induces oscillations, which affect both the spectral bandwidth and the phase-locking properties above threshold. Strategies to mitigate the GVD’s undesired and unpredictable spectral variation will be presented.

Meyer, J. R↗

Burst-mode dual-comb spectroscopy

We introduce a new modality of dual-comb spectroscopy that enables a simplified and powerful new approach for time-resolved measurements with increased acquisition rates. This "burst mode" form of dual-comb spectroscopy (BM-DCS) relies on the multiplexing of each probe pulse into a short train of pulses. With this approach we demonstrate a time-resolved series of absorption-based spectroscopic measurements of a laser-induced plasma using only a single laser ablation shot and identify 22 Nd lines not previously reported in the literature. The transmission spectra spanned 3.1 THz and were acquired at an effective acquisition rate of 25 kHz with 40 ms time-resolution. This simple modification to 100 MHz level dual-comb systems provides a flexible approach for studying transient and low duty-cycle events such as laser-induced plasmas, combustion, and explosive reactions.

(280.5395) Plasma Diagnostics, broadband laser spe↗

Multi-species temperature and number density analysis of a laser-produced plasma using dual-comb spectroscopy

Dual-comb spectroscopy (DCS) represents a novel method of using absorption spectroscopy as a diagnostic tool for multispecies analysis of excitation temperatures and column densities in laser-produced plasmas (LPPs). DCS was performed on a LPP generated by ablating a multielement alloy containing Nd, Gd, and Fe. Transitions from all three elements were observed in absorption spectra measured from 530.08 to 535.19 nm at seven time-delays from 31 to 250 μs after ablation. The spectra were fit using a nonlinear regression algorithm to determine peak areas, and excitation temperatures and column densities were determined for the three atomic species separately using Boltzmann plots. The measured excitation temperatures of Nd I and Gd I showed good agreement at all time-delays, whereas the Fe I temperature was found to be higher, and the ratios between the column densities varied with delay. The observations are understood via effects of LPP spatial averaging, elemental fractionation, and molecular formation and are compared and contextualized with previous work studying LPPs using other spectroscopic techniques. A brief discussion of the precision and accuracy of the determined excitation temperatures and column densities is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of neutral gadolinium oscillator strengths using dual-comb absorption spectroscopy in laser-produced plasmas

The oscillator strengths of 43 transitions of neutral gadolinium from 530 to 535 nm were determined based on high-resolution absorption spectra measured by probing a laser-produced plasma (LPP) using time-resolved dual-comb spectroscopy (DCS). Absorption spectra were measured at various time delays, ranging from 33 to 252 µs after the onset of the plasma formation, over which the temperature and number density varied as the ablation plume evolved. A Boltzmann analysis was used to determine the excitation temperature and column density of Gd in the ablation plume, based on measured absorption from 20 Gd I spectral lines with known oscillator strengths. Oscillator strengths were then determined for additional dipole-allowed Gd I transitions identified in the absorption spectra, 19 of which were previously unreported. Oscillator strengths of all measured transitions were compared with literature values when available and show good agreement in most cases. Time-resolved measurement of atomic absorption in the cooling plasma provides access to a range of excitation temperatures and optical densities for the atoms in the ablation plume, allowing repeated measurements under different conditions, thereby improving confidence in the results. The high spectral bandwidth and resolution capabilities of DCS make it well-suited to measuring the dense optical spectrum of Gd, and the technique is applicable to other elements, especially lanthanides and actinides.

(280.4788) Optical Sensing, (280.5395) Plasma Diag↗